• Title/Summary/Keyword: Head method

Search Result 3,052, Processing Time 0.036 seconds

Acoustic emission source location and noise cancellation for crack detection in rail head

  • Kuanga, K.S.C.;Li, D.;Koh, C.G.
    • Smart Structures and Systems
    • /
    • v.18 no.5
    • /
    • pp.1063-1085
    • /
    • 2016
  • Taking advantage of the high sensitivity and long-distance detection capability of acoustic emission (AE) technique, this paper focuses on the crack detection in rail head, which is one of the most vulnerable parts of rail track. The AE source location and noise cancellation were studied on the basis of practical rail profile, material and operational noise. In order to simulate the actual AE events of rail head cracks, field tests were carried out to acquire the AE waves induced by pencil lead break (PLB) and operational noise of the railway system. Wavelet transform (WT) was first utilized to investigate the time-frequency characteristics and dispersion phenomena of AE waves. Here, the optimal mother wavelet was selected by minimizing the Shannon entropy of wavelet coefficients. Regarding the obvious dispersion of AE waves propagating along the rail head and the high operational noise, the wavelet transform-based modal analysis location (WTMAL) method was then proposed to locate the AE sources (i.e. simulated cracks) respectively for the PLB-induced AE signals with and without operational noise. For those AE signals inundated with operational noise, the Hilbert transform (HT)-based noise cancellation method was employed to improve the signal-to-noise ratio (SNR). Finally, the experimental results demonstrated that the proposed crack detection strategy could locate PLB-simulated AE sources effectively in the rail head even at high operational noise level, highlighting its potential for field application.

Head and neck reconstruction using free flaps: a 30-year medical record review

  • Suh, Joong Min;Chung, Chul Hoon;Chang, Yong Joon
    • Archives of Craniofacial Surgery
    • /
    • v.22 no.1
    • /
    • pp.38-44
    • /
    • 2021
  • Background: The free flap surgical method is useful for the reconstruction of head and neck defects. This study retrospectively analyzed the results of head and neck reconstructions using various types of free flaps over the past 30 years. Methods: Between 1989 and 2018, a total of 866 free flap procedures were performed on 859 patients with head and neck defects, including 7 double free flaps. The causes of vascular crisis and salvage rate were analyzed, and the total flap survival rate calculated among these patients. Additionally, the survival and complication rates for each flap type were compared. Results: The 866 cases included 557 radial forearm flaps, 200 anterolateral thigh flaps, 39 fibular osteocutaneous flaps, and 70 of various other flaps. The incidence of the vascular crisis was 5.1%; its most common cause was venous thrombosis (52.3%). Salvage surgery was successful in 52.3% of patients, and the total flap survival rate was 97.6%. The success rate of the radial forearm flap was higher than of the anterolateral flap (p< 0.01), and the primary sites of malignancy were the tongue, tonsils, and hypopharynx, respectively. Conclusion: The free flap technique is the most reliable method for head and neck reconstruction; however, the radial forearm free flap showed the highest success rate (98.9%). In patients with malignancy, flap failure was more common in the anterolateral thigh (5.5%) and fibular (5.1%) flaps.

Application and Verification of Coupled Analysis of Piled Piers (교량 말뚝기초 해석기법의 적용성 분석)

  • Won Jin-Oh;Jeong Sang-Seom
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.4
    • /
    • pp.123-134
    • /
    • 2005
  • A coupled three-dimensional pile group analysis method (YSGroup) was developed considering nonlinear pile head stiffness matrices and compared with other analytical methods (elastic displacement method, Group 6.0 and FBPier 3.0). In this method, a pile cap was modelled by four-node flat shell element, a pier was modelled using 3 dimensional beam element, and individual piles were modelled as beam-column elements. Through the comparative studies on a piled pie. subjected to lateral loads in linear soil, it was found that present method (YSGroup), elastic displacement method and Group 6.0 gave similar results of lateral pile head displacement, but FBPier 3.0 was estimated to show somewhat larger displacements than those from the three methods. Displacements of superstructure (pier), including nonlinear soil behavior, could be estimated by present method (YSGroup) and FBPier 3.0 because these two methods modelled the superstructure directly by finite element techniques. It was found that pile groups in pinned pile head condition had a tendency to cause excessive rotation of the pile cap.

The Experiences of Job Stress on Head Nurses in General Hospitals (종합병원 수간호사의 직무 스트레스 경험)

  • Kang, Sung-Rye
    • Journal of Korean Academy of Nursing
    • /
    • v.37 no.4
    • /
    • pp.501-509
    • /
    • 2007
  • Purpose: The purpose of this study was to identify job stress experienced by head nurses of general hospitals. Methods: Data was collected from 10 head nurses with in-depth interviews about their actual experiences. The main questions were when, why, and from whom they get stress in the work field; how they are affected by the stressful situation; and how they cope with this stress. All the interviews were recorded and transcribed. The collected data was analyzed using a consistent comparative data analysis method. Results: Job stress of head nurse was formed by 3 axis; causes, reactions, and coping strategies in complicated situational context such as human relationship, culture of hospital, individual characteristics, social support. Conclusion: The results of this study yields very useful information for nursing mangers to identify, by stages, the demands of the head nurses in their role adaptation process. The findings of this study contributes to developing programs and supportive policies that palliates the head nurses' job stress.

Process Improvement of PCB Electric Circuit Pattern by Ink Drop Jetting Control and Characteristics Analysis of Industrial Inkjet Piezoelectric Print Head (산업용 잉크젯 압전프린트 헤드의 특성해석 및 잉크 망점제어에 의한 PCB 전기회로패턴 공정개선)

  • Youn, Shin-Yong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.65 no.1
    • /
    • pp.57-65
    • /
    • 2016
  • This paper was analyzed the characteristics of piezoelectric inkjet print head using finite element method(FEM). It showed the bending node driving of piezoelectric and relation theory principle consider piezoelectric material characteristics and ink characteristics. From such result we were had the piezoelectric head design and manufacture. It got a this head characteristics through experiment, we confirmed that proper voltage control is possible to through ink drop control experiment of piezoelectric print head. This paper was obtained the suitable ink jetting characteristics that manufacture the control circuit and piezoelectric inkjet print head. This practice product was applied to improvement of PCB electric circuit pattern by etching resist ink that PCB manufactured to complex process over traditional 6 stages can be simpled to 1 stage by inkjet printing technology.

Adaptive Distortion Correction System of Head Up Display (Head Up Display의 적응적 왜곡 보정시스템)

  • Chi, Yongseok;Kim, Youngseop;Lee, Yong-Hwan;Lee, Myoung-Seok
    • Journal of the Semiconductor & Display Technology
    • /
    • v.13 no.3
    • /
    • pp.57-60
    • /
    • 2014
  • The distortion correction system of Head up display that is installed in vehicle has been studied both experimentally and theoretically for the removal of the optical lens distortion. A new adaptive correction method is having a decisive effect on correction in the optical lens distortion of Head up display. This adaptive correction system removes various distortion that has occurred because of the design tolerances of Head up display and the assemble tolerances into vehicle. It is especially efficient in removal of a barrel distortion and pin cushion of Head up display.

An investigation on noise quality of the gear head for ac induction motor (AC Induction motor용 강력형 Gear Head의 소음 특성 연구)

  • Kim, Joo-Han;Sung, Ha-Kyeong;Im, Tae-Bin;Chung, Jung-Kee
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2390-2392
    • /
    • 2001
  • The small gear head noise is caused by gear accuracy, assembling errors, and gear backlash. This main study is an investigation on noise quality of the small gear head through the change of gear backlash. In this study included gear design parameters related the small gear head, the knowledge of rattle noise related gear backlash, and the experimentation results of the small head noise through change of gear backlash. At last, this study propose the least method of the small gear head noise that is caused by suitable existence of gear backlash.

  • PDF

Anthropometry of Surface Area (인체의 표면적 측정)

  • 이근부
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.18 no.36
    • /
    • pp.41-47
    • /
    • 1995
  • This study present a systematic and more economical anthropometric technique to acquire 3-D anthropometric data by the use of moire interferometry, image processing and computer vision techniques. An experiment was performed to measure in anthopometric variables (head and face), such as head length, head breath, length of ear to top of head, contained face areas, etc. We took fourty-five subjects with wide range of ages(18 years to 33 years old). The face area was calculated based on contour information. The results were then compared with plaster bandage methods. It turned out that the proposed method had 90.85% consistancy.

  • PDF

Accuracy Verification of Optical Tracking System for the Maxillary Displacement Estimation by Using of Triangulation (삼각측량기법을 이용한 광학추적장치의 상악골 변위 계측에 대한 정확성 검증)

  • Kyung, Kyu-Young;Kim, Soung-Min;Lee, Jong-Ho;Myoung, Hoon;Kim, Myung-Jin
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.1
    • /
    • pp.41-52
    • /
    • 2012
  • Purpose: Triangulation is the process of determining the location of a point by measuring angles to it from known points at either end of a fixed baseline. This point can be fixed as the third point of a triangle with one known side and two known angles. The aim of this study was to find a clinically adaptable method for applying an optical tracking navigation system to orthognathic surgery and to estimate its accuracy of measuring the bone displacement by use of triangulation methods. Methods: In orthognathic surgery, the head position is not fixed as in neurosurgery, so that a head tracker is needed to establish the reference point on the head surface byusing an optical tracking system. However, the operation field is interfered by its bulkiness that makes its clinical use difficult. To solve this problem, we designed a method using an Aquaplast splinting material and a mini-screw in applying a head tracker on a patient's forehead. After that, we estimated the accuracy of measuring displacements of the ball marker by an optical tracking system with a conventional head tracker (Group A) and with a newly designed head tracker (Group B). Measured values of ball markers' displacements by each optical tracking system were compared with values obtained from fusion CT images for an estimation of accuracy. Results: The accuracy of the optical tracking system with a conventional head tracker (Group A) is not suitable for clinical usage. Measured and predictable errors are larger than 10 mm. The optical tracking system with a newly designed head tracker (Group B) shows 1.59 mm, 6.34 mm, and 9.52 mm errorsin threeclinical cases. Conclusion: Most errors were brought on mainly from a lack of reproducibility of the head tracker position. The accuracy of the optical tracking system with a newly designed head tracker can be a useful method in further orthognathic navigation surgery even though the average error is higher than 2.0 mm.

Analytical Head-space Supercritical Fluid Extraction Methodology for the Determination of Organochlorine Compounds in Aqueous Matrix

  • Ryoo, Keon-Sang;Ko, Seong-Oon;Hong, Yong-Pyo;Choi, Jong-Ha;Kim, Yong-gyun;Lee, Won-Kyoung
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.5
    • /
    • pp.649-656
    • /
    • 2006
  • The proposed head-space supercritical fluid extraction (SFE) methodology as an alternative to an existing conventional procedure was explored for the determination of organochlorine compounds in aqueous matrix. In this study, polychlorinated biphenyls (PCBs) and organochlorine pesticides (OCPs) were utilized as target analytes. To enhance the recovery efficiency, the factors such as the $CO _2$ density, the extraction time, and the extraction mode were investigated. Furthermore, the analytical procedures and the results obtained were compared with those provided by the conventional method (the U.S. EPA method 8080). Under the optimized conditions, i.e., a combination of static with dynamic SFE mode at 2,000 psi and 40 ${^{\circ}C}$, the head-space SFE methodology gave equivalent or better to the conventional method in recovery efficiencies with clear advantages such as simple sample treatment and fast analysis time as well as reduced solvent and reagent consumption.