• Title/Summary/Keyword: Head leakage

Search Result 86, Processing Time 0.023 seconds

Radionuclide Cisternographic Findings in Patients with Spontaneous Intracranial Hypotension (자발성 두개내 저압 환자의 방사성 동위원소 뇌조조영술 소견)

  • Jung, Dong-Jin;Kim, Jae-Seung;Ryu, Jin-Sook;Shin, Jung-Woo;Im, Joo-Hyuk;Lee, Myoung-Chong;Jung, Sun-Joo;Moon, Dae-Hyuk;Lee, Hee-Kyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.6
    • /
    • pp.482-489
    • /
    • 1998
  • Purpose: Radionuclide cisternography may be helpful in understanding pathophysiology of postural head-ache and low CSF pressure in patients with spontaneous intracranial hypotension. The purpose of this study was to characterize radionuclide cisternographic findings of spontaneous intracranial hypotension. Materials and Methods: The study population consists of 15 patients with spontaneous intracranial hypotension. Diagnosis was based on their clinical symptoms and results of lumbar puncture. All patients underwent radionuclide cisternography following injection of 111 to 222 MBq of Tc-99m DTPA into the lumbar subarachnoid space. Sequential images were obtained between 112 hour and 24 hour after the injection of Tc-99m DTPA. Radioactivity of the bladder, soft tissue uptake, migration of radionuclide in the subarachnoid space, and extradural leakage of radionuclide were evaluated according to the scan time. Results: Radionuclide cisternogram showed delayed migration of radionuclide into the cerebral convexity (14/15), increased soft tissue uptake (11/15), and early visualization of bladder activity at 30min (6/10) and 2hr (13/13). Cisternography also demonstrated leakage site of CSF in 4 cases and 2 of these were depicted at 30min. Epidural blood patch was done in 11 patients and headache was improved in all cases. Conclusion: The characteristic findings of spontaneous intracranial hypotension were delayed migration of radionuclide and early visualization of the soft tissue and bladder activity. These scintigraphic findings suggest that CSF leakage rather than increased CSF absorption or decreased production may be the main pathophysiology of spontaneous intracranial hypotension. Early and multiple imaging including the bladder and soft tissue is required to observe the entire dynamics of radionuclide migration.

  • PDF

Pediatric Pancreatic Tumors-Clinical Experience (소아 췌장종양의 임상양상 및 치료결과 분석)

  • Park, Hyung-Woo;Kim, Dae-Yeon;Cho, Min-Jeong;Kim, Tae-Hun;Kim, Seong-Cheol;Kim, In-Ku
    • Advances in pediatric surgery
    • /
    • v.16 no.1
    • /
    • pp.11-17
    • /
    • 2010
  • Pancreatic tumors in children are relatively rare, and their prognosis differs from that in adults. The purpose of this study is to examine the clinical characteristics, treatment, and prognosis for children with pancreatic tumors. We retrospectively reviewed the medical records of children under 15 years of age with pancreatic tumors who were treated surgically at Asan Medical Center between January 1992 and November 2009. There were 16 patients, fourteen of whom were pathologically diagnosed with solid pseudopapillary tumor. The other two patients were diagnosed with pancreatoblastoma and acinar cell carcinoma, respectively. Six patients of the 16 patients (38 %) were male, and there was a male-to-female ratio of 1:1.6. The initial presentations were upper abdominal pain in eight patients (50 %), palpable abdominal mass in three, and vomiting in one. Four patients were diagnosed incidentally. Six patients' tumors were located in the pancreatic head, six in the pancreatic body, and four in the pancreatic tail, respectively. The surgical procedures performed included distal pancreatectomy (n=7, 44 %), median segmentectomy (n=3), enucleation (n=3), pancreaticoduodenectomy (n=2), and pylorus-preserving pancreaticoduodenectomy (n=1). Three patients underwent laparoscopic surgery. The median tumor size was 6.5 cm (1.8~20 cm). Early surgical complications included pancreatic fistula (n=4), bile leakage (n=1), and delayed gastric emptying (n=1). A late complication in one patient was diabetes. The median follow-up period was five years and four months, and all patients survived without recurrence. While pancreatic tumors in adults have a poor prognosis, pancreatic tumors of childhood are usually curative with complete resection and thus have a favorable prognosis.

  • PDF

Usefulness assessment of secondary shield for the lens exposure dose reduction during radiation treatment of peripheral orbit (안와 주변 방사선 치료 시 수정체 피폭선량 감소를 위한 2차 차폐의 유용성 평가)

  • Kwak, Yong Kuk;Hong, Sun Gi;Ha, Min Yong;Park, Jang Pil;Yoo, Sook Hyun;Cho, Woong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.1
    • /
    • pp.87-95
    • /
    • 2015
  • Purpose : This study presents the usefulness assessment of secondary shield for the lens exposure dose reduction during radiation treatment of peripheral orbit. Materials and Methods : We accomplished IMRT treatment plan similar with a real one through the computed treatment planning system after CT simulation using human phantom. For the secondary shield, we used Pb plate (thickness 3mm, diameter 25mm) and 3 mm tungsten eye-shield block. And we compared lens dose using OSLD between on TPS and on simulation. Also, we irradiated 200 MU(6 MV, SPD(Source to Phantom Distance)=100 cm, $F{\cdot}S\;5{\times}5cm$) on a 5cm acrylic phantom using the secondary shielding material of same condition, 3mm Pb and tungsten eye-shield block. And we carried out the same experiment using 8cm Pb block to limit effect of leakage & transmitted radiation out of irradiation field. We attached OSLD with a 1cm away from the field at the side of phantom and applied a 3mm bolus equivalent to the thickness of eyelid. Results : Using human phantom, the Lens dose on IMRT treatment plan is 315.9cGy and the real measurement value is 216.7cGy. And after secondary shield using 3mm Pb plate and tungsten eye-shield block, each lens dose is 234.3, 224.1 cGy. The result of a experiment using acrylic phantom, each value is 5.24, 5.42 and 5.39 cGy in case of no block, 3mm Pb plate and tungsten eye-shield block. Applying O.S.B out of the field, each value is 1.79, 2.00 and 2.02 cGy in case of no block, 3mm Pb plate and tungsten eye-shield block. Conclusion : When secondary shielding material is used to protect critical organ while irradiating photon, high atomic number material (like metal) that is near by critical organ can be cause of dose increase according to treatment region and beam direction because head leakage and collimator & MLC transmitted radiation are exist even if it's out of the field. The attempt of secondary shield for the decrease of exposure dose was meaningful, but untested attempt can have a reverse effect. So, a preliminary inspection through Q.A must be necessary.

  • PDF

Thoracoscopic Diaphragmatic Plication Using Three 5 mm Ports (흉강경하 횡경막 주름성형술: 작업창없이 3개의 포트를 이용한 수술법)

  • Kim, Do-Hyung;Kim, Kil-Dong;Hwang, Jung-Joo;Choi, Jin-Ho;Lee, Jun-Wan
    • Journal of Chest Surgery
    • /
    • v.43 no.5
    • /
    • pp.513-517
    • /
    • 2010
  • Background: Diaphragmatic plication through a thoracoscopic approach has been an effective modality to treat diaphragmatic enventration. However, the conventional technique for thoracoscopic plication has some disadvantages. We have developed an improved and simplified technique with utilizing the head up position, $CO_2$ insufflation and figure-of-eight sutures. Material and Method: Between October 2005 and September 2009, 9 patients with diaphragmatic paralysis underwent repair using our modified technique. The mean patient age was $38.5{\pm}53.0$ years (range: 2~76 years). Result: The mean operation time was $46.7{\pm}15.9$ min (range: 30~85 min). None of the patients died due to this procedure, but there was one case of prolonged air leakage, and a case of re-expansion pulmonary edema, which required 3 days of ventilator support after the procedure. The mean hospital stay was $6.22{\pm}2.04$ days (range: 4~11 days). The mean follow-up duration was $27.2{\pm}11.6$ months (range: 2~43 months). All the patients had their symptoms relieved and there was no recurrence of eventration except for one patient who developed more than 2 cm elevation of the diaphragm compared to the immediate post-operation status. Conclusion: With our technique, thoracoscopic diaphragmatic plication was feasible via using only three 5 mm ports and without a working window and the midterm results were favorable. Therefore, we advocate thoracoscopic diaphragmatic plication as a preferred technique to the conventional open plication technique.

The Evaluation of Radiation Dose to Embryo/Fetus and the Design of Shielding in the Treatment of Brain Tumors (임산부의 전뇌 방사선 치료에 있어서의 태아의 방사선량 측정 및 차폐 구조의 설계)

  • Cho, Woong;Huh, Soon-Nyung;Chie, Eui-Kyu;Ha, Sung-Whan;Park, Yang-Gyun;Park, Jong-Min;Park, Suk-Won
    • Journal of Radiation Protection and Research
    • /
    • v.31 no.4
    • /
    • pp.203-210
    • /
    • 2006
  • Purpose : To estimate the dose to the embryo/fetus of a pregnant patient with brain tumors, and to design an shielding device to keep the embryo/fetus dose under acceptable levels Materials and Methods : A shielding wall with the dimension of 1.55 m height, 0.9 m width, and 30 m thickness is fabricated with 4 trolleys under the wall. It is placed between a Patient and the treatment head of a linear accelerator to attenuate the leakage radiation effectively from the treatment head, and is placed 1 cm below the lower margin of the treatment field in order to minimize the dose to a patient from the treatment head. An anti-patient scattering neck supporters with 2 cm thick Cerrobend metal is designed to minimize the scattered radiation from the treatment fields, and it is divided into 2 section. They are installed around the patient neck by attach from right and left sides. A shielding bridge for anti-room scattered radiation is utilized to place 2 sheets of 3 mm lead plates above the abdomen to setup three detectors under the lead sheets. Humanoid phantom is irradiated with the same treatment parameters, and with and without shielding devices using TLD, and ionization chambers with and without a build-up cap. Results : The dose to the embryo/fetus without shielding was 3.20, 3.21, 1.44, 0.90 cGy at off-field distances of 30, 40, 50, and 60 cm. With shielding, the dose to embryo/fetus was reduced to 0.88, 0.60, 0.35, 0.25 cGy, and the ratio of the shielding effect varied from 70% to 80%. TLD results were 1.8, 1.2, 0.8, 1.2, and 0.8 cGy. The dose measured by the survey meter was 10.9 mR/h at the patient's surface of abdomen. The dose to the embryo/fetus was estimated to be about 1 cGy during the entire treatment. Conclusion : According to the AAPM Report No 50 regarding the dose limit of the embryo/fetus during the pregnancy, the dose to the embryo/fetus with little risk is less than 5 cGy. Our measurements satisfy the recommended values. Our shielding technique was proven to be acceptable.

Soil CO2 Monitoring Around Wells Discharging Methane (메탄 유출 관정 주변의 토양 CO2 모니터링)

  • Chae, Gitak;Kim, Chan Yeong;Ju, Gahyeun;Park, Kwon Gyu;Roh, Yul;Lee, Changhyun;Yum, Byoung-Woo;Kim, Gi-Bae
    • Economic and Environmental Geology
    • /
    • v.55 no.4
    • /
    • pp.407-419
    • /
    • 2022
  • Soil(vadose zone) gas compositions were measured for about 3 days to suggest a method for monitoring and interpreting soil gas data collected around wells from which methane(CH4) is outflowing. The vadose zone gas samples were collected within 1 m around two test wells(TB2 and TB3) at Pohang and analyzed for CO2, CH4, N2 and O2 concentrations in situ. CO2 flux was measured beside TB2. In addition, gas samples from well head in TB2 and atmospheric air samples were collected for comparison. Carbon isotopes of CO213CCO2) of samples collected on the last day of the study period were analyzed in the laboratory. The two test wells (TB2 and 3) were 12.7 m apart and only TB3 was cemented to the surface. According to the bio-geochemical process-based interpretation, the relationships between CO2 and O2, N2, and N2/O2 of vadose zone gas were plotted between the lines of CH4 oxidation and CO2 dissolution. In addition, the CH4 concentrations of gas samples from the wellhead of the uncemented well (TB2) were 5.2 times higher than the atmospheric CH4 concentration. High CO2 concentrations (average 1.148%) of vadose zone gas around TB2 seemed to be attributed to the oxidation of CH4. On the other hand, the vadose zone CO2 around the cemented well(TB3) showed a relatively low concentration(0.136%). This difference indicates that the vadose zone gas(including CO2) around the CH4 outflowing well were strongly affected by well completion(cementing). This study result can be used to establish strategies for environmental monitoring of soil around natural gas sites, and can be used to monitor leakage around injection and observation wells for CO2 geological storage. In addition, the method of this study is useful for soil monitoring in natural gas storage and oil-contaminated sites.