• 제목/요약/키워드: Head lamp

검색결과 46건 처리시간 0.019초

다문화 결혼이주여성의 구강건강 관련 특성에 관한 연구 : 경북 김천시를 중심으로 (Oral health characteristics of the multicultural international marriage women in Gimcheon, Gyeongbuk, Korea)

  • 이종화;남인숙;전매숙;윤현경
    • 한국치위생학회지
    • /
    • 제15권5호
    • /
    • pp.865-872
    • /
    • 2015
  • Objectives: The purpose of the study is to investigate the oral health characteristics of the multicultural international marriage women in Gimcheon, Gyeongbuk in Korea. Methods: The subjects were 73 multicultural international marriage women in Gimcheon, Gyeongbuk in Korea. The study methods consisted of direct interview with the subjects and oral examination through dental mirror and head lamp by one dentist and two dental hygienists. The questionnaire included the use of medical services, oral health education experience, subjective oral health awareness, toothbrushing, and sociodemographical characteristics of the subjects. Results: There were significant correlations between the subjective oral health awareness, oral health behavior and DMFT index. The subjective oral health awareness significantly changed after the international marriage in Korea. The recognition of subjective oral health status significantly improved after the oral health education by the dentist and the dental hygienist. Conclusions: The subjective oral health status of the international marriage women improved significantly after immigration into Korea. Therefore, Korean government should try to provide the better medical services to the international marriage women and protect their human rights as Korean immigrants on the basis of the Law.

영상기반 차량 후미등 상태 인식 알고리즘 (Video Based Tail-Lights Status Recognition Algorithm)

  • 김규영;이근후;도진규;박근수;박장식
    • 한국전자통신학회논문지
    • /
    • 제8권10호
    • /
    • pp.1443-1449
    • /
    • 2013
  • 전방 차량의 자동검출은 충돌회피, 자동운행제어 그리고 자동 헤드램프 조정 등의 고급 운전지원시스템의 통합 요소이다. 주야간 상관없이 전방 차량 자동 검출과 운행 상태를 인지하는데 있어 후미등은 중요한 역할한다. 그런데, 많은 운전자들이 차량의 후미등 상태를 알지 못하고 운행하는 경우가 많다. 따라서, 후미등에 이상이 있는 차량에 대하여 자동으로 후미등 이상 상태를 알려주는 시스템이 필요하다. 본 논문에서는 영상처리 및 인식기술을 기반으로 차량의 후미등 상태를 인식하는 방법을 제안한다. 톨게이트 등으로 진입하는 차량을 검출하기 위하여 배경추정기법, 옵티컬 플로우(optical flow) 그리고 Euclidean 척도를 이용한다. Lab 색좌표에서 집중 맵(saliency map)을 적용하여 차량에서 후미등 영역을 검출하고 상태를 판정한다. 고속도로 톨게이트 영상을 이용하여 후미등 상태인식 실험을 하고, 제안하는 방법이 운전자에게 후미등 상태 전달하는데 활용할 수 있음을 보인다.

Floating Zone법에 의한 Mn-Zn Ferrite 단결정성장에 관한 연구 (The Study on the Crystal Growing of Mn-Zn Ferrite Single Crystals by Floating Zone Method)

  • 정재우;오근호
    • 한국결정성장학회지
    • /
    • 제2권1호
    • /
    • pp.10-19
    • /
    • 1992
  • Soft Ferrites 가운데 대표적인 자성재료로써 최근에 개발된 Mn-Zn Ferrite는 높은 초기투자율과 포화자속밀도, 낮은 손실계수를 갖고 있으며 또한, 단결정으로써의 기계적 특성이 우수하며 VTR Head의 소재로 사용되는 중요한 전자부품이다. melt를 수용하는 도가니를 사용치 않아 결정으로의 불순물 침입이 없으며 halogen lamp로부터 방출된 적외선을 열원으로 하여 한 곳에 초점을 이루어 온도구배를 크게 유지하여 결정성장을 이루는 Floating Zone(FZ)법에 의해 Ar 및 $O_2$혼합가스 분위기 하에서 직경 8mm의 Mn-Zn Ferrite 단결정을 육성하였다. 성장 중 용융대에서의 최고온도는 $1650^{\circ}C$ 온도를 유지하였고 결정성장 속도는 10mm/hr, 회전속도는 20 rpm 이었으며 성장방위를 확인하기 위해 Laue 분석 및 XRD, TEM을 이용, 결정의 상등을 분석하였으며 화학적인 etching을 하여 광학현미경을 통해 etch pits 형상을 관찰하였다. 그리고 양질의 결정을 얻기 위해 원료봉 직경에 따른 결정화 속도와 적정한 melt직경과 길이에 대한 상관관계를 찾아내었고 또한 성장계면의 양상에 대해 고찰하였다.

  • PDF

전외측 대퇴부 천공지 유리피판술의 실패 원인과 합병증 (The Result and Attentiveness of Reconstructive Surgery by Anterolateral Thigh Perforator Free Flap)

  • 강경동;이재우;김경훈;오흥찬;최치원;최수종;배용찬;남수봉;김정일;추기석
    • Archives of Plastic Surgery
    • /
    • 제38권1호
    • /
    • pp.27-34
    • /
    • 2011
  • Purpose: Anterolateral thigh (ALT) perforator free flap is commonly used because of its various benefits. The author reports important factors of preoperative and perioperative ALT perforator free flap and causes of failure. Methods: 84 patients who were treated with ALT perforator free flap from December 2004 to 2008, and February 2010 to April 2010 were studied. 61 patients were male and 23 were female. The mean age of patients was 51.1. The main cause was neoplasm and the main reconstructive areas were head and neck area. The size of flap was various from $3{\times}4$ to $12{\times}18$ cm. 6 patients received split thickness skin graft at donor site. Preoperative angiography was checked to all patients. Results: Among the 84 patients, partial necrosis of flaps occurred in 4 patients because of atherosclerosis, varicose vein, or inattention of patient, etc. And total flap necrosis in 5 patients because of abnormal vessels of recipient area or delay of operation, etc. One case of serous cyst was found as the complication of donor area. Two cases of skin graft on donor site were done because of suspected muscle compartment syndrome, 4 cases of that because of large flap. Septocutaneous perforators were found in 7 cases. The author couldn't find reliable perforator in 3 cases, ipsilateral anteromedial thigh perforator and contralateral ALT perforator and latissimus dorsi musculocutaneous free flap were done instead of ALT. There was no case which needed reoperation because of the impairment of blood supply, and 3 cases were revised by leech because of the burn injury by a lamp or venous congestion. Conclusion: Although ALT perforator free flap is widely used with its various merits, many factors such as preoperative condition of donor or recipient area, morphology of defect and operating time need to consider to prevent flap necrosis. And operators should need careful technique because septocutaneous perforator is uncommon, and musculocutaneous perforator is common but difficult to dissect.

실물 재하시험을 통한 짧은말뚝의 횡방향 저항거동 평가 (Investigation of Lateral Resistance of Short Pile by Large-Scale Load Tests)

  • 이수형;최영태;이일화;유민택
    • 한국지반공학회논문집
    • /
    • 제33권8호
    • /
    • pp.5-16
    • /
    • 2017
  • 근입깊이가 직경에 비하여 상대적으로 작은 말뚝은 편심이 큰 횡방향 하중을 받는 경우 전도되어 파괴된다. 지금까지 횡방향하중을 받는 짧은말뚝의 지지거동에 대해서는 주로 모형실험을 적용한 연구가 수행되었지만, 전주, 표지판, 가로등 기초와 같이 매우 큰 모멘트를 받는 짧은말뚝의 지지거동은 아직까지 명확히 규명된 바 없다. 본 연구에서는 직경 750mm의 실물크기 말뚝에 대한 재하시험을 수행하였다. 실제 하중조건을 모사하기 위하여 기초로 부터 8m 이격된 지점에 횡방향 하중을 가하여 매우 큰 모멘트를 유발하였으며, 말뚝의 근입깊이를 2.0m, 2.5m, 3.0m로 변화시킨 3회의 시험을 수행하였다. 시험결과 큰 모멘트를 받는 짧은말뚝은 파괴 직전까지 변위나 회전각이 거의 발생하지 않다가 전도로 인해 급격한 변위가 발생하는 취성형태로 파괴 되었다. 이러한 거동은 기존의 횡방향 위주의 하중을 받는 짧은말뚝에서 나타난 연성파괴 거동과는 대조적이다. 기존에 제안된 세 종류의 지지력 예측식으로 부터 구한 짧은말뚝의 극한 횡방향지지력을 시험결과와 비교하였으며, 말뚝 근입깊이가 상대적으로 작은 경우는 말뚝선단 중심의 회전을 가정한 제안식이 적절하지만, 근입깊이가 커지면서 회전점을 중심으로 응력방향이 반전되는 토압분포를 가정한 제안식이 보다 적절한 것으로 평가되었다.

Hydroxyapatite 안구보충물삽입술 후 골신티그라피를 이용한 섬유혈관증식 평가: 평면영상과 SPECT 영상에서의 비교 (Assessment of Vascularization within Hydroxyapatite Ocular Implant by Bone Scintigraphy: Comparative Analysis of Planar and SPECT Imaging)

  • 임석태;손명희;박순아
    • 대한핵의학회지
    • /
    • 제33권6호
    • /
    • pp.475-483
    • /
    • 1999
  • 목적: 안구보충물로 사용된 hydroxyapatite 내로의 섬유혈관증식은 이물질 반응으로 인한 염증의 동반없이 의안의 운동성을 유지시키기 위한 운동성 나사못을 삽입하는데 중요한 역할을 한다. 안구보충물 삽입술 후에 섬유혈관증식의 정도를 알아보는데 Tc-99m MDP를 이용한 평면영상과 단면영상에서 정성적 평가와 정량적 평가의 비교분석을 함으로서 완전한 섬유혈관증식을 예측하는데 단면영상의 유용성을 알아보고자 하였다. 대상 및 방법: 안구 제거술후 hydroxyapatite를 이용하여 안구보충술을 시행받고 $197{\pm}81$일 후에 골신티그라피를 시행받은 17명의 환자(남:녀=12:5, 연령; $50.4{\pm}17.5$세)의 18예를 대상으로 하였다. 골신티그라피는 Tc-99m MDP 740 MBq를 정맥주사 후 4시간 경과뒤에 이중헤드 감마카메라(ECAM, Siemens, Germany)로 안면부 평면영상을 얻은 후 이어서 단면영상을 얻었다. 평면영상과 단면영상에서의 안구보충물의 방사능 섭취가 비교(nasal bridge)보다 약한 경우를 grade 1, 비슷한 경우를 grade 2, 강한 경우를 grade 3로 평가하였고, 정상안구에 대한 안구보충물의 섭취비를 정량적으로 구하여 운동성 나사못 삽입술 후 시행된 세극등 검사에서 염증반응의 동반 없이 완전한 섬유혈관증식을 보인 환자 군과 염증 반응의 동반과 함께 불완전한 섬유혈관증식을 보인 환자 군으로 나누어 비교 분석하였다. 결과: 평면영상에서 grade 1은 9예, grade 2가 1예, grade 3가 2예로 충분한 섬유혈관증식을 의미하는 grade 2와 3를 보인 경우가 9예 (50%) 이었으나 단면영상에서는 grade 1이 6예, grade 2가 4예, grade 3가 8예로 평면영상에 비하여 grade 2와 3를 보이는 경우가 12예(61%) 이었다. 정성적 평가에 의한 완전한 섬유혈관증식을 예측하는 데 있어서 평면영상은 예민도가 60% (9/15),특이도 100% (3/3), 양성예측률 100% (9/9), 음성예측률 33.3% (3/9), 정확도 66.7% (12/18) 이었고 단면영상은 예민도 80% (12/15), 특이도 100% (3/3), 양성예측률 100% (12/12), 음성예측률 50% (3/6), 정확도 83.3% (15/18) 이었다. 정량적으로 구한 안구보충물 내의 방사능 섭취비는 평면영상에서 grade 1은 $1.19{\pm}0.10$, grade 2는 $2.16{\pm}0.43$, grade 3는 $3.57{\pm}0.74$로 grade가 높을수록 정량적 섭취비가 유의하게 증가하였다(p<0.001). 단면영상에서 grade 1은 $3.06{\pm}1.22$, grade 2는 $3.71{\pm}0.83$, grade 3는 $12.49{\pm}4.31$로 grade가 높을수록 정량적 섭취비가 유의하게 증가하였다(p<0.001). 완전한 섬유혈관증식을 보인 환자 군과 불완전한 섬유혈관증식을 보인 환자군으로 나누어 정량적으로 측정한 방사능 섭취비를 비교시 평면영상에서는 $1.96{\pm}0.87$$1.17{\pm}0.08$로 유의한 차이를 보이지 않았으나 단면영상에서는 $8.44{\pm}5.45$$2.20{\pm}0.87$로 유의한 차이를 보였다 (p<0.05). 결론: 안구보충물 삽입 후 섬유혈관증식을 평가할 때 평면영상에 비하여 단면영상이 섬유혈관증식 정도를 평가하는데 보다 도움을 주었다.

  • PDF