• Title/Summary/Keyword: Head coil

Search Result 123, Processing Time 0.023 seconds

The Role of Lumbar Drainage to Prevent Shunt-Dependent Hydrocephalus after Coil Embolization for Aneurysmal Subarachnoid Hemorrhage in Good-Grade Patients

  • Yong, Cho-In;Hwang, Sung-Kyun;Kim, Sung-Hak
    • Journal of Korean Neurosurgical Society
    • /
    • v.48 no.6
    • /
    • pp.480-484
    • /
    • 2010
  • Objective : To evaluate the role of lumbar drainage in the prevention of shunt-dependent hydrocephalus after treatment of ruptured intracranial aneurysms by coil embolization in good-grade patients. Methods : One-hundred-thirty consecutive patients with aneurysmal subarachnoid hemorrhage in good-grade patients (Hunt & Hess grades I-III), who were treated by coil embolization between August 2004 and April 2010 were retrospectively evaluated. Poor-grade patients (Hunt & Hess grades IV and V), a history of head trauma preceding the development of headache, negative angiograms, primary subarachnoid hemorrhage (SAH), and loss to follow-up were excluded from the study. We assessed the effects on lumbar drainage on the risk of shunt-dependent hydrocephalus related to coil embolization in patients with ruptured intracranial aneurysms. Results : One-hundred-twenty-six patients (96.9%) did not develop shunt-dependent hydrocephalus. The 2 patients (1.5%) who developed acute hydrocephalus treated with temporary external ventricular drainage did not require permanent shunt diversion. Overall, 4 patients (3.1%) required permanent shunt diversion; acute hydrocephalus developed in 2 patients (50%). There was no morbidity or mortality amongst the patients who underwent a permanent shunt procedure. Conclusion : Coil embolization of ruptured intracranial aneurysms may be associated with a lower risk for developing shunt-dependent hydrocephalus, possibly by active management of lumbar drainage, which may reflect less damage for cisternal anatomy than surgical clipping. Coil embolization might have an effect the long-term outcome and decision-making for ruptured intracranial aneurysms.

Clinical Utility of Turbo Contrase-Enhanced MR Angiography for the Major Branches of the Aortic Arch (대동맥궁 주요 분지들의 고속 조영증강 자기공명혈관조영술의 임상적 유용성)

  • Su Ok Seong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.2 no.1
    • /
    • pp.96-103
    • /
    • 1998
  • Purpose : To assess the clinical utility of turbo contrast-enhanced magnetic resonance angiography(CE MRA) in the evaluation of the aortic arch and its major branches and to compare the image quality of CE MRA among different coils used. Materials and Methods : Turbo three-phase dynamic CE MRA encompassing aortic arch and its major branches was prospectively performed after manual bolus IV injection of contrast material in 29 patients with suspected cerebrovascular diseases at 1.0T MR unit. the raw data were obtained with 3-D FISH sequence (TR 5.4ms, TE 2.3ms, flip angle 30, slab thickness 80nm, effective slice thickness 4.0mm, matrix size $100{\times}256$, FOV 280mm). Total data acquisition time was 4. to 60 seconds. We subjectively evaluated the imge quality with three-rating scheme : "good" for unequivocal normal finding, "fair" for relatively satisfactory quality to diagnose 'normal' despite intravascular low signal, and "poor" for equivocal diagnosis or non-visualization of the origin or segment of the vessels due to low signal or artifacts which needs catheter angiography. At the level of the carotid bifurcation, it was compared with conventional 2D-TOF MRA image. Overall image quality was also compared visually and quantitatively by measuring signal-to-noise ratios (SNRs) of the ascending aorta, the innominate artery and both common carotid arteries among the three different coils used(CP body array(n=12), CP neck array(n=9), and head-and-neck(n=8). Results : Demonstration of the aortic arch and its major branches was rated as "good" in 55% (16/29) and "fair" in 34%(10/29). At the level of the carotid bifurcation, image quality of turbo CE MRA was same as or better than conventional 2D-TOF MRA in 65% (17/26). Overall image quality and SNR were significantlygreater with CP body array coil than with CP neck array or head-and-neck coil. Conclusions : Turbo CE MRA can be used as a screening exam in the evaluation of the major branches of the aortic arch from their origin to the skull base. Overall imagequality appears to be better with CP body array coil than with CP neck array coil or head-and-neck coil.

  • PDF

Effectiveness evaluation of Distance-adjustable Head coil (거리조절 가능한 두부 수신 코일의 유용성 평가)

  • Lee, Ho-beom;Jeong, Mi-Ae
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2019.05a
    • /
    • pp.233-234
    • /
    • 2019
  • 자기공명영상 검사 시, 거리조절 두부 전용 코일을 사용할 경우 환자의 체격이 크거나 의료기구의 사용 등으로 거리를 증가시켜야 하는 경우 환자에게 불편함을 주지 않고 양질의 신호를 가진 영상을 얻을 수 있을 것이라고 사료 된다.

  • PDF

Sensor Calibration of a Helmet MEG System (헬멧형 뇌자도 장치의 센서 교정)

  • Kwon, H.;Kim, K.;Yu, K.K.;Kim, J.M.;Lee, Y.H.
    • Progress in Superconductivity
    • /
    • v.12 no.1
    • /
    • pp.57-61
    • /
    • 2010
  • We have developed a whole-head MEG system for basic brain research and clinical application. The sensor system consists of a 152 SQUID gradiometer array oriented and located in a suitable way to cover a whole head of the human. The system measures magnetic fields generated by neuronal currents in the brain to get information on the brain activities. For this purpose, the field sensitivity determined by the position, orientation and geometry of the pickup coil as well as amplification factor of the electronic circuits should be known precisely. However, the position and orientation of the pickup coil might be changed from the designed specifications during cool down of the dewar and it is necessary to characterize the field sensitivity. In this study, we made calibration systems to determine the actual position and orientation of the 152 pickup coils and compared the localization results of the N100m source in the auditory cortex.

Defect detection for a conductor using amorphous wire sensor head (금석 구조체의 미소결함검사에 대한 기초적인 검토)

  • Kim, Y.H.;Shin, K.H.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.35-39
    • /
    • 2002
  • A defect detection test was performed for a conductor using a amorphous wire sensor head. A uniform magnetic field was applied in the space between the most inner conductors of a spiral-typed coil. The conductor with a defect was placed on the space between the most inner conductors of spiral-typed coil. The defect can be detected from the differences of induced voltage measured in the vicinity of gap of the conductor. The induced voltage difference of 2.5mV was measured in the gap vicinity of the 1mm thick conductor having 0.5mm gap in the frequency region of 100kHz~600kHz.

  • PDF

Development of Birdcage RF coil for 3T Animal MR Imaging

  • 추명자;최보영;강세권;최치봉;이형구;서태석
    • Progress in Medical Physics
    • /
    • v.13 no.2
    • /
    • pp.85-89
    • /
    • 2002
  • We authors developed a new small-size birdcage RF coil for animal MR images. And we compared signal-to-noise ratio (SNR) of the new small coil with a conventional knee coil. The dimension of the low-pass type birdcage coil with 12 elements at 37 MRI system are 13 cm outer diameter, 12 cm inner diameter and 20 cm length. For each element, the width of copper tape is 0.05 mm, thickness is 8 mm and length is 20 cm. The small birdcage coil with 12 elements exhibited 7 resonance modes. The isolation of the quadrature channel could be achieved more than 20 ㏈. The coil quality factor (Q value) was 98.6. The SNR of the animal coil was 243.2 on the average and was about twice as high as the conventional knee coil. The present study successfully demonstrated that the small birdcage coil could provide high quality animal MR images with the improved SNR. Therefore, it is expected that the small birdcage coil could be used in the clinical diagnosis and research studies for veterinary medicine in the near future.

  • PDF

Characteristics of fiber-optic current sensors using perpendicular coil formers (수직원형틀을 이용한 광섬유전류센서의 동작특성)

  • 이명래;이용희;김만식
    • Korean Journal of Optics and Photonics
    • /
    • v.7 no.4
    • /
    • pp.419-427
    • /
    • 1996
  • Thermally-stabilized fiber-optic current sensors are proposed and demonstrated. The sensor head is made of two coil formers combined perpendicularly. In this sensor head, bending-induced birefringences can be reduced to the level much smaller than those of the single former type because the eigen-axes of the two perpendicular coil formers are made orthogonal to each other. Moreover, thermal variation of the birefringence is also expected to be minimized by the orthogonality of the two polarization eigen-axes. We changed the temperature slowly in the range of 20~45$^{\circ}C$ during 100 minutes. The overall linearity of the sensor is better than 1.2% in the range of 0~1000A. The long-term fluctuation of the sensor is less than 1% when measured for 3 hours at 500A and room temperature. Two orthogonally-polarized laser diodes are combined together to make the incident beam unpolarized. In the signal processing, the signals are separated by two parts and normalized respectively, which minimize the efects of optical fluctuations coming from sources, connectors, etc.

  • PDF

Analysis and Design of Whole-Head Magnetic Brain Stimulators: A Simulation Study

  • Lee, Chany;Im, Chang-Hwan;Jung, Hyun-Kyo
    • International Journal of Control, Automation, and Systems
    • /
    • v.5 no.3
    • /
    • pp.337-342
    • /
    • 2007
  • This paper proposes a helmet-type whole-head brain stimulator system considering a realistic head geometry. For more accurate design and computer simulations, a realistic volume conductor model was adopted and the current evoked on human cerebral cortex was analyzed using the boundary element method (BEM). To obtain a more focalized evoked current around the target points, various coil configurations were tested and an average targeting error of about 10 mm was obtained.

Design and Contact Force Control of a Flip Chip Mounting Head system

  • Kim, Kyoung-Jun;Shim, Jae-Hong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1060-1065
    • /
    • 2003
  • This paper contributes to development of a new chip mounting head system for flip chip. Recently, the LDM(Linear DC Motor) has been widely used, because it has particular merits than the rotary type motors. In this paper, we proposed a macro/micro positioning system for force control of a chip mounting system. In the proposed macro/micro system, the macro actuator provide the system with a gross motion while the micro device yields fine tuned motion to reduce the harmful impact force that occurs between very small sized electronic parts and PCB surface. In order to prove the effectiveness of the proposed macro/micro chip mounting system, we compared the proposed chip mounting head with the conventional chip mounting head equipped with a macro actuator only. A series of experiments were executed under the mounting conditions of various access velocities and PCB stiffness. As a result of this study, a satisfactory voice coil actuator as the micro actuator has been developed, and its performance meet well the specifications desired for the design of the chip mounting head system and show good correspondence between theoretical analysis and experimental results.

  • PDF