• 제목/요약/키워드: Head coil

검색결과 124건 처리시간 0.023초

고 자장에서 Dynamic Susceptibility Contrast 효과에 관한 연구 : Gradient EPI와 Spin-EPI기법의 비교 (A Study on Dynamic Susceptibility-weighted Perfusion MR Imaging at High Magnetic Filed : Comparison of Gradient Echo-EPI and Spin Echo-EPI)

  • 구은회;채홍인;박종배;임청환;김정구
    • 대한디지털의료영상학회논문지
    • /
    • 제9권2호
    • /
    • pp.11-16
    • /
    • 2007
  • We have evaluated and compared of gradient echo and spin echo EPI for compensating about deeply distortion aspect in case of post-operation patients in magnetic resonance image. A total of 100 patients were performed on 3.0 T(GE Signa Excite E2, USA) with 8ch head coil. As a result of analysis, The SNRs of whiter and gray matter areas were 36.74 $\pm$ 06 and 39.96 $\pm$ 09 in the gradient echo EPI, the SNRs which white and gray matter areas were slightly higher than gradient echo EPI(P<0.005, paired student t-test). It was 46.24 $\pm$ 11 and 51.38 $\pm$ 13 in gradient and spin echo EPI, respectively. The signal intensity in the whiter and gray matter areas also were 87.33 $\pm$ 15.24 and 140.66 $\pm$ 13.45 in the gradient echo EPI techniques, The signal intensity of gradient echo EPI showed higher values compared to spin echo EPI. Otherwise, gradient echo EPI technique is distortion enough to operation wound and edge of the image, while spin echo EPI technique did not appear almost. In this point, the spin echo EPI technique, after surgical operation according to patient state beside gradient echo EPI techniques that signalbeside gradient echo EPI techniques that signal intensity is high and patient's case which image distortion is serious by metal etc, will be provide the useful information in adults and pediatric patients.

  • PDF

MAGNETIC RESONANCE IMAGING을 이용한 악관절 원판 천공 진단 (PERFORATION OF THE TEMPOROMANDIBULAR JOINT MENISCUS: DIAGNOSED BY MAGNETIC RESONANCE IMAGING)

  • Kim, Houng-Gon;Dolan, Eward;Vogler, James B.;Nokes, Steven R.
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제11권2호
    • /
    • pp.11-18
    • /
    • 1989
  • 최근의 악관절(TMJ) 방사선학적 진단에 있어 많은 발전과 진단방법이 고안돼어 왔다. 또한 새로운 외과적 술식의 발달로 인하여 악관절내장증(Internal Derangement)의 보다 정확한 진단을 요하게 되었다. 가장 새로운 진단방법으로 핵자기공명촬영법(Magnetic Resonance Imaging:MRI)이 악관절내장증 진단 평가하는데 사용되어지고 있다. 핵자기공명촬영법은 surface coil을 이용하여 관절원판(meniscus)의 비정상적 변화를 효과적으로 진달할 수 있으며, 지금까지 이용되어오던 악관절조영술(arthrography)이나 컴퓨터 단층촬영법(C-T scan)의 단점인, 관절내 조영제 주입이나 방사선 노출둥의 문제점을 배제할 수 있다. 본 연구는 악관절 핵자기공명촬영을 한 92명(184 joints)중 천공(perforation)으로 진단된 31 명 (39 joints)를 대상으로 하였으며, 핵자기공명촬영법의 취약점으로 지적되고 있는 악관절원판 천공 진단의 정확도를 측정하기 위하여 가역적 조사를 통해, 악관절원판 천공으로 진단되어 수술받은 15명(20 joints)에서 65%(13 joints)의 정확성을 확인하였다. 또한 핵자기공명촬영법을 통한 악관절원판 진단의 정확도를 높이기 위하여 condyle head의 퇴행성 변화, articular eminence의 변화, condyle spurring, bone to bone contact등의 경조직 변화와 meniscus의 discontinuity, meniscal deformity, loss of joint space, alternated bilaminar zone 등이 악관절원판 천공진단의 중요한 findings 임을 증명 하였다.

  • PDF

조영제 사용 전 후 확산강조영상 검사의 비교 분석에 대한 연구 (A Study on Comparative Analysis of Diffusion Weighted Image Examination before and after Contrast Injection)

  • 구은회
    • 대한디지털의료영상학회논문지
    • /
    • 제11권2호
    • /
    • pp.51-57
    • /
    • 2009
  • The purpose of this study would evaluate if having clinical effects on diffusion image with quantitative analysis through ADC values of brain's normal tissue and lesions before and after contrast injections using a 3.0T. From November in 2007 until December in 2008, a total of 32 patient was performed on 3.0T(Signa Excite, GE Medical System, USA) with the normal or lesions in the patient who requests diffusion weighted image with 8channel head coil. The pulse sequence was used with spin echo EPI(TR: 10000msec, TE: 72.2 msec, Matrix: 128*128, FOV: 240 mm, NEX: 1, diffusion direction: 3, b-value: 1000). Measurement results of ADC values on lesions, CSF, white matter, gray matter, lesions after contrast injection were measured less 75% than before contrast injection, infarction: 100%, CSF: 78%(high), white matter: 71.4%(low), gray matter: 50%(high, low). The results of paired t-test on the deference of ADC values which statically is significant in three(lesions, CSF, white matter)regions except for white matter(p<0.05). Quantitative analysis of lesions, CSF, white matter, gray matter have difference on all regions. ADC values were low in lesions and white matter, normal CSF after contrast injection commonly is high than before contrast injection, ADC values which white matter were high and low (50:50) after contrast injection. 3.0T diffusion weighted image clinically supposed that performing DWI examination after contrast injection was not desirable because of having effects on brain tissue.

  • PDF

교류전류를 이용한 비접촉결함탐상법에 관한 연구 - 주파수 lift-off의 영향 - (A Study on the Non-Contact Detection Technique of Defects Using AC Current - The Influence of Frequency and lift-off -)

  • 김훈;나의균
    • 비파괴검사학회지
    • /
    • 제22권1호
    • /
    • pp.53-58
    • /
    • 2002
  • 계자코일에 흐르는 교류전류로 전자기장을 유도하고, 결함에 의하여 누설되는 자속을 간극을 갖는 헤드로 측정하여 결함을 검출하는 새로운 비파괴탐상장치를 구성하였다. 이 탑상장치는 비접촉으로 강자성체의 구조물 요소에 존재하는 표면결항을 검출하고, 그 크기를 평가하는데 적용할 수 있다. 본 논문은 강자성체에 도입한 2차원 표면결함에 적용하여 결함의 평가를 실시하였다. 또한 측정주파수와 lift-off가 이들 평가에 미치는 영향을 검토하였다. 결함은 전압 분포에서 최대치로 검출할 수 있고, 이 최대전압의 변화는 결함의 깊이가 증가함에 따라 증가한다. 결함의 최대전압은 주파수와 lift-off 의 영향을 받지만, 작은 깊이의 결함은 깊이와 전압이$(V_0/V_{ave})$의 관계로부터 선형적으로 예측할 수 있다.

Usefulness of Dexmedetomidine during Intracerebral Aneurysm Coiling

  • Lee, Hyoun-Ho;Jung, Young-Jin;Choi, Byung-Yon;Chang, Chul-Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • 제55권4호
    • /
    • pp.185-189
    • /
    • 2014
  • Objective : General anesthesia is often preferred for endovascular coiling of intracranial aneurysm at most centers. But in the authors' hospital, it is performed under monitored anesthesia care (MAC) using dexmedetomidine. To determine the feasibility and safety of this approach, the authors reviewed our initial experience. Methods : Retrospective data was analyzed from July 2012 to November 2012. We performed coil embolization in 28 cases using this method. Among them, for statistical significance, we analyzed 12 cases in which the procedure time exceeded an hour. Vital signs were analyzed every 10 minutes. Depth of sedation was measured according to the Ramsay sedation scale and frequency of the repeated roadmap image(s) caused by movement of the patient's head during the procedure. Results : All procedures were completed without occurrence of procedure related complications. Under MAC using dexmedetomidine, vital signs of the patients were stable, no statistical significance regarding hemodynamic and respiratory parameters was observed between time points (p>0.05). Adequate sedation was achieved. Mean Ramsay sedation scale was $3.67{\pm}1.61$ (2 to 6). Repeated roadmap image(s) due to patient's factor occurred in only one case. The mean dosage of drug for adequate sedation for the procedure was $0.65{\pm}0.12mcg/kg/hr$ without loading doses. Conclusion : To the best of my knowledge, this is the first report published in English using the method of monitored anesthesia with dexmedetomidine for intracranial aneurysm coiling. Monitored anesthesia care using dexmedetomidine without loading dose for embolization of intracranial aneurysms appeared to be a safe and effective alternative to general anesthesia.

ACR 팬텀을 이용한 Cartesian Trajectory와 MultiVane Trajectory의 비교분석 : 영상강도 균질성과 저대조도 검체 검출률 test를 사용하여 (Comparative Analysis of Cartesian Trajectory and MultiVane Trajectory Using ACR Phantom in MRI : Using Image Intensity Uniformity Test and Low-contrast Object Detectability Test)

  • 남순권;최준호
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권1호
    • /
    • pp.39-46
    • /
    • 2019
  • This study conducted a comparative analysis of differences between cartesian trajectory in a linear rectangular coordinate system and MultiVane trajectory in a nonlinear rectangular coordinate system axial T1 and axial T2 images using an American College of Radiology(ACR) phantom. The phantom was placed at the center of the head coil and the top-to-bottom and left-to-right levels were adjusted by using a level. The experiment was performed according to the Phantom Test Guidance provided by the ACR, and sagittal localizer images were obtained. As shown in Figure 2, slices # 1 and # 11 were scanned after placing them at the center of a $45^{\circ}$ wedge shape, and a total of 11 slices were obtained. According to the evaluation results, the image intensity uniformity(IIU) was 93.34% for the cartesian trajectory, and 93.19% for the MultiVane trajectory, both of which fall under the normal range in the axial T1 image. The IIU for the cartesian trajectory was 0.15% higher than that for the MultiVane trajectory. In axial T2, the IIU was 96.44% for the cartesian trajectory, and 95.97% for the MultiVane trajectory, which fall under the normal range. The IIU for the cartesian trajectory was by 0.47% higher than that for the MultiVane trajectory. As a result, the cartesian technique was superior to the MultiVane technique in terms of the high-contrast spatial resolution, image intensity uniformity, and low-contrast object detectability.

소아 뇌에서의 혼성 이차원 양성자자기공명분광법의 임상적 응용 (Hybrid Two-Dimensional Proton Spectroscopic Imaging of Pediatric Brain: Clinical Application)

  • Sung Won Youn;Sang Kwon Lee;Yongmin Chang;No Hyuck Park;Jong Min Lee
    • Investigative Magnetic Resonance Imaging
    • /
    • 제6권1호
    • /
    • pp.64-72
    • /
    • 2002
  • 목적 : 소아 뇌 질환에서의 자기공명분광법의 임상적 적용에 있어서 단일화적소 양성자 자기공명분광법과 고식적 이차원 양성자 자기공명분광법에 비해 혼성 이차원 양성자 자기공명분광법이 가지는 장점에 대하여 알아보고자 하였다. 대상 및 방법 : 생후 3일에서 15세까지의 79명의 소아 (정상소아 36명, 저산소성-허혈성 뇌 손상 10명, 대사성 질환 20명, 뇌막염-뇌염 3명, 뇌종양 7명, 신경섬유종증 1명, Sturge-Weber 증후군 1명, lissencephaly 1명)를 대상으로 81회의 혼성 이차원 양성자 자기공명분광검사를 시행하였다. 성인자원자(n=5)에서 단일화적소 양성자 자기공명분광법, 고식적 이차원 양성자 자기공명분광법, 그리고 혼성 이차원 양성자 자기공명분광법 모두를 실시하였고, 환아군 중 일부(n=12)에서 PRESS기법을 이용한 단일화적소 분광법과 혼성 이차원 양성자 자기공명 분광법을 함께 시행하였다. 1.5-T 초전도영상장치 하에서 standard head quatrature coil을 이용하여 양성자 자기공명분광을 얻었다. Phase encoding step은 16$\times$16으로 하였고, FOV는 환자 뇌의 크기에 따라 다양하게 하였으며, FOV내의 혼성 관심 체적 (hybrid VOI)은 $75{\times}75{\times}15{\;}\textrm{mm}^3$ 또는 그 이하로 함으로써 원하지 않는 지방에 의한 신호를 없애도록 하였다. PRESS기법 (TR/TE= 1,500 msec/135 또는 270 msec)을 적용하였고, 물에 의한 신호를 억제하기 위하여 chemical shift selective saturation pulse를 사용하였다. 혼성 이차원 양성자 자기공명분광검사의 획득시간(data acquistion time)과 분광의 질(spectral quality)을 단일화적소 양성자 자기공명분광법과 고식적이차원양성자 자기공명분광법의 그것과 비교하였다. 결과: 혼성 이차원 양성자 자기공명분광법은 79명의 소아 전 예에서 성공적으로 시행되었다. 단일화적소 양성자 자기공명분광법의 획득시간은 4.3분인 반면에, 혼성 이차원 양성자 자기공명분광법의 획득시간(data acquition time)은 6분 미만으로, 이는 소아의 뇌영상용으로 쓰기에 충분히 짧은 소요시간이었다. 혼성 이차원 양성자 자기공명분광법에 의한 분광은 단일화적소 자기공명분광법에 의한 분광과 거의 비슷한 민감도와 분광분해 능을 나타내었으며, 반면에 고식적인 이차원 양성자 자기공명분광법에 의한 분광보다는 훨씬 우수하였다.

  • PDF

3T Multi Voxel Spectroscopy에서 SENSE와 NEX 변화에 따른 정상인 뇌 대사물질 변화 분석 (Alteration Analysis of Normal Human Brain Metabolites with Variation of SENSE and NEX in 3T Multi Voxel Spectroscopy)

  • 성열훈;임재동;이재현;조성봉;우동철;최보영
    • 한국의학물리학회지:의학물리
    • /
    • 제19권4호
    • /
    • pp.256-262
    • /
    • 2008
  • 자기공명분광법(magnetic resonance spectroscopy: MRS)은 인체내 대사물질을 정량분석하여 병변의 조기진단 및 정밀진단에 도움을 주고 있으며, 최근 임상에 이용되고 있는 자기공명분광법은 single voxel spectroscopy (SVS) 기법과 multi voxel spectroscopy (MVS) 기법이 있다. 본 연구에서는 SENSE와 NEX를 변화시킨 multi voxel spectroscopy (MVS)의 데이터와 기존 single voxel spectroscopy (SVS)의 데이터를 비교 분석하여, 각각의 데이터의 유의성 차이를 평가하고자 하였다. 정상 성인 지원자 13명(남자: 5명, 여자: 8명, 평균 41세, 표준편차 11.65세)을 대상으로 chemical shift image (CSI)를 이용한 MVS검사를 시행하였다. 장비는 3.0T Achieva Release Version 2.1 (Philips Medical System, Netherland)을 이용하였고, 8 channel head coil을 사용하여 brain thalamus 부위에서 CSI spectrum을 1 slice 획득하였다. Scan parameter로는 FOV (field of view): $230{\times}184mm^2$, TR (time to repetition): 2000 msec, TE (time to echo): 288 msec, matrix: $15{\times}12$, VOI(view of interest): $110{\times}110mm^2$, voxel size: $15{\times}15{\times}15mm^3$로 하였다. SENSE factor (S)와 NEX (N)는 S1*N1, S2*N1, S2*N2, S3*N2로 변화하여 스펙트럼을 획득하였고, 각 scan time은 5분 54초, 3분 32초, 6분 20초, 4분 20초였다. 얻은 모든 MRS 데이터는 jMRUI 3.0 Version 프로그램에서 분석하였고, SENSE factor와 NEX를 변화시켜 얻은 MVS data 그룹들이 정상 성인 뇌 대사물질의 변화에 영향을 주는지 검증하기 위해 그룹 간에 ANOVA분석을 실행하여 P 값이 0.05보다 크게 나오면 그룹들 사이에 유의한 차이가 없다고 분석하였다. NAA/Cr과 Cho/Cr의 상대적 비율은 MV와 SVS사이에서는 유의한 차이가 없었다. 즉, SENSE factor와 NEX를 변화시켜 얻은 MVS data에서 정상 성인 뇌조직의 대사물질의 변화를 관찰한 결과, S1*N1의 NAA/Cr은 $1.45{\pm}0.03$, Cho/Cr은 $0.88{\pm}0.03$이고, S2*N1의 NAA/Cr은 $1.44{\pm}0.03$, Cho/Cr은 $0.87{\pm}0.05$, S2*N2의 NAA/Cr은 $1.43{\pm}0.02$, Cho/Cr은 $0.87{\pm}0.04$이며, S3*N2의 NAA/Cr은 $1.45{\pm}0.03$, Cho/Cr은 $0.87{\pm}0.03$으로 나타났다(F-value : 1.37, D.F : 3, P-value : 0.262). 그러나 데이터의 질을 측정하기 위한 MVS 데이터의 NAA Peak line-width는 SVS 데이터의 NAA Peak line-width 보다 약 3배 정도 넓었다. 본 연구에서는 MVS에서 SENSE factor와 NEX 값을 다양하게 변화시킨 MVS의 데이터와 SVS의 데이터가 큰 차이가 없음을 확인하였다. 즉, 어는 특정 부위의 뇌 조직의 대사물질은 MVS와 SVS 기법 모두 큰 차이가 없음을 확인할 수 있었다. 그러므로 MVS는 SVS보다 광범한 부위를 짧은 시간 안에 검사할 수 있으므로 매우 유용한 방법이라고 사료된다.

  • PDF

급성 허혈성 뇌경색 환자에서 동맥스핀표지 관류자기공명영상의 유용성 (Clinical Usefulness of Arterial Spin Labeling Perfusion MR Imaging in Acute Ischemic Stroke)

  • 오근택;정홍량;임청환;조영기;하본철;홍동희
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제34권4호
    • /
    • pp.323-331
    • /
    • 2011
  • 본 연구는 급성 허혈성 뇌경색 환자에서 동맥스핀표지 관류자기공명영상의 임상적 유용성을 평가하고자 하였다. 급성 허혈성 뇌경색 증상으로 응급실로 내원한 환자 중 확산강조영상(DWI)의 병변의 크기가 3 cm 이상이고 역동적 자화율대조 조영증강 관류자기공명(DSC)영상, 동맥스핀표지 관류자기공명(ASL)영상을 모두 시행한 22명과 정량적 분석을 위한 정상대조군 36명을 대상으로 하였다. 사용된 장비로는 Siemens Magnetom Verio 3.0 T이고 12 Chanel Head Coil을 사용하였다. 정성적 평가는 rMTT, TTP, rCBF, rCBV, ASL지도의 병변 인지도평가와 확산강조영상과 병변의 크기 비교평가를 하였고 정량적 평가는 각 관류영상의 평균 상대값을 Mann-Whitney U test를 사용하여 병변 그룹과 정상군 그룹의 유의성을 분석한 결과는 다음과 같다. 첫째, 병변의 인지도평가에서 TTP(95.5%), rCBF(95.5%), 지도가 가장 높았고, 둘째, 최종 뇌경색부위 연관성은 rCBV와 rCBF지도가 높게 나타났다. 셋째, 정량적 분석에서는 병변그룹의 평균 상대값은 유의하게 나타났다(p<0.05). 동맥스핀표지 관류자기공명(ASL)영상은 높은 병변의 인지율을 보여 임상에서 적용가능하다 생각되며, 정량적 상대값은 제시하기 어렵지만 참고적 자료로 사용될 수 있을 것이며 향후 지속적 연구를 한다면 뇌경색의 조기진단, 허혈성 반영부의 존재여부와 범위, 혈류역동학적평가가 가능함으로써 치료방침을 정하고 예후를 파악하는데 ASL영상이 유용할 것으로 사료된다.

자기공명확산강조영상에서 SE-EPI 와 SSH-TSE 기법을 이용한 영상의 질 평가 (Evaluation of Image Quality using SE-EPI and SSH-TSE Techniques in MRDWI)

  • 구은회
    • 한국방사선학회논문지
    • /
    • 제15권7호
    • /
    • pp.991-998
    • /
    • 2021
  • 본 연구의 목적은 뇌 자기공명영상에서 확산강조 검사에 대한 SE-EPI 기법과 SSH - TSE 기법에 대한 영상의 질을 알아보고자 한다. MRDWI 검사를 시행한 환자를 무작위로 선정한 PACS 전송 데이터 35명 중 정상 남자 12명, 정상 여자 13명, 뇌경색 10명 중 남자 5 여자 5, 평균나이 68 ± 7.32를 대상으로 데이터를 분석하였다. 사용된 장비는 Ingenia CX 3.0T을 사용하였고 데이터 획득을 위하여 SSH-TSE, SE-EPI 펄스시퀀스와 32 Channel Head Coil를 이용하였다. 영상평가는 paired t-test와 Wilcoxon 검정을 하였으며 p 값이 0.05 이하 일 때 유의성이 있는 것으로 간주하였다. DWI 영상에 대한 SNR대한 정량적 분석 결과 ADC(s/mm2), Diffusion b=0, 1000영상에서 4 부위(WM, GM, BG, Cerebellum)의 평균 및 표준편차 값이 SE-EPI기법(ADC:120.50 ± 40, b=0: 54.50 ± 35.91, b=1000: 91.61 ± 36.63)이 SSH-TSE(ADC:99.69 ± 31.10, b=0: 43.52 ± 25.00 , b=1000: 60.74 ± 24.85) 보다 높게 나타났다(p<0.05). GM-WM, BG-WM 부위에 대한 CNR 값 또한 SE-EPI기법(ADC:116.08 ± 43.30 , b=0: 27.23 ± 09.10 , b=1000: 78.50 ± 16.56)이 SSH-TSE(ADC:101.08 ± 36.81, b=0: 23.96 ± 07.79 , b=1000: 74.30 ± 14.22) 보다 높게 나타났다(p<0.05). 관찰자의 시각적 평가로서 SSH-TSE, SE-TSE에 대한 Ghost 인공물 자화율 인공물, 전반적인 영상의질 모두 SSH-TSE 기법이 높은 결과를 얻었다(ADC:3.6 ± 0.1, 2.8 ± 0.2, b=0: 4.3 ± 0.3, 3.4 ± 0.1 b=1000: 4.3 ± 0.2, 3.5 ± 0.2, p=0.000). 결론적으로, SSH-TSE, SE-EPI를 사용한 SNR, CNR 측정에서 SE-EPI 기법이 우위의 결과를 얻었다. 정성적 분석에서는 펄스시퀀스 특성에 따라 SSH-TSE 펄스시퀀스가 높은 결과를 얻었다.