• 제목/요약/키워드: Head Distribution

검색결과 915건 처리시간 0.03초

A Study on Photon Dose Calculation in 6 MV Linear Accelerator Based on Monte Carlo Method (몬테카를로 방법에 의한 6 MV 선형가속기의 광자 흡수선량 분포 평가에 관한 연구)

  • Kang, Sang-Koo;Ahn, Sung-Hwan;Kim, Chong-Yeal
    • Journal of radiological science and technology
    • /
    • 제34권1호
    • /
    • pp.43-50
    • /
    • 2011
  • In this study we modeled the varian 2100C/D linear accelerator head and multi-leaf collimator by simulation with the GEANT4 Monte Carlo toolkit. Then central axis percentage depth dose profiles and lateral dose profiles within homogeneous water phantom($50{\times}50{\times}50\;cm^3$) were evaluated with 6 MV photon beam. The simulations were performed in two stages. In the first stage, photon energy spectrum at the target were computed were computed. Then spectra data was directly irradiated in the water phantom using sampling techniques. The simulation data were compared with experimental data to evaluate the accuracy of the model. Results showed that two data were matched within 2% error boundary. The proposed method will be applied for simulation of dose calculation and dose distribution study.

Changes in Distributive Equity of Health Insurance Contribution Burden (건강보험료 부담의 형평성 변화)

  • Kang, Hee-Chung;Park, Eun-Cheol;Lee, Kyu-Sik;Park, Tae-Kyu;Chung, Woo-Jin;Kim, Han-Joong
    • Journal of Preventive Medicine and Public Health
    • /
    • 제38권1호
    • /
    • pp.107-116
    • /
    • 2005
  • Objectives : We analyzed the changes from 1996 to 2002 in distributive equity of the contribution burden in the Korean National Health Insurance. Methods : The study subjects were a total of 8,923 employee households and a total of 7,296 self-employed households over the period from 1996 to 2002. Those were the households meeting the two criteria as completing each annual survey and having no change in the job of head of the household during that period from the raw data of the Household Income and Expenditure Survey annually conducted by the Korean National Statistical Office. The unit of analysis was a household, and this was the standard for assessing the contribution that is now applied on a monthly basis. Deciles Distribution Ratio, Contribution Concentration Curve and Contribution Concentration Index were estimated as the index of inequality. Multiple regression analysis was conducted to compare the annual ability-to-pay elasticity of the contribution to the reference year of 1996 for three groups (all households, the employee households, and the self-employed households). Results : For the index of inequality, the distributive equity of contribution was improved in all three groups. In particular, the employee group experienced a substantial improvement. Using multiple regression analysis, the ability-to-pay elasticity of the contribution in the employee group significantly increased ($\beta$=0.232, p<0.0001) in the year 2002 as compared to the reference year of 1996. The elasticity in the self-employed group also significantly increased ($\beta$=0.186, p<0.05), although its change was smaller than that in the employee group. Conclusions : The employee group had a greater improvement for the distributive equity of the contribution burden than the self-employed group. Within the observation period, there were two important integration reforms: one was the integration of 227 self-employed societies in 1998 and the other was the integration of 139 employee societies in 2000. We expected that the equity of the contribution burden would be improved for the self-employed group since the integration reform of 1998. However, it was not improved for the self-employed group until the year 2000. This result suggests that capturing exactly the beneficiaries' ability-to-pay such as income is the precedent for distributive equity of the contribution burden, although a more sophisticated imposition standard of contribution is needed.

Comparison of Spectroscopic Characteristics and Chemical Oxygen Demand Efficiencies for Dissolved Organic Matters from Diverse Sources (기원별 용존 유기물의 분광특성 및 COD 산화율 비교)

  • Jung, Ka-Young;Park, Min-Hye;Hur, Jin;Lee, Seungyoon;Shin, Jae-Ki
    • Journal of Korean Society on Water Environment
    • /
    • 제25권4호
    • /
    • pp.589-596
    • /
    • 2009
  • The spectroscopic characteristics and chemical oxygen demand (COD) oxidation efficiencies were investigated for dissolved organic matters (DOM) from diverse sources, which may indirectly affect the concentrations and the quality of DOM found in watersheds. The DOM investigated for this study showed a wide range of the percent distributions of refractory organic matter (R-OM) from 8 to 100%. Relatively high R-OM distributions were observed for the DOM with the source of head water, sediments, paddy soils, field soils, and treated sewage whereas the DOM from livestock waste, reed, weeds, algae, and attached algae exhibited lower R-OM percent distributions. The percent distribution of R-OM had positive correlations with specific UV absorbance (SUVA) and humidification indices (HIX) of DOM. The investigated DOM was classified into four different source groups (i.e., biota, vegetables, soils, sediments) by comparing the synchronous fluorescence spectra. The DOM group from biota source was characterized by a prominent presence of protein-like fluorescence (PLF) whereas fulvic-like fluorescence (FLF) was additionally observed for vegetable-source DOM. FLF became significant for the DOM from both soils and sediments although no PLF was found for soil-derived DOM. A range of COD oxidation efficiency was observed for the various DOM, ranging from 36 to 94% and from 65 to 125% for $COD_{Mn}$ and $COD_{Cr}$, respectively. The results indicate that $COD_{Cr}$ reflects the higher OM concentration than $COD_{Mn}$. However, 95% confidence intervals of the COD oxidation efficiencies were similar for the two types of COD, suggesting that $COD_{Cr}$ may not be the superior OM index to $COD_{Mn}$ in terms of the variability of the oxidation efficiency. No significant correlations were obtained between COD oxidation efficiencies and the spectroscopic characteristics of DOM for this study.

Fuel Concentration Measurements by Laser Rayleigh Scattering (레이저 Rayleigh 산란을 이용한 연료농도 계측시 잡음원인과 대책)

  • Kwon, Soon-Tae;Lee, Jae-Won;Park, Chan-Jun;Ohm, In-Young
    • Journal of Energy Engineering
    • /
    • 제17권4호
    • /
    • pp.189-197
    • /
    • 2008
  • In this study, a system to measure continuously the fuel concentration in a steady flow rig on the basis of Rayleigh scattering is presented. The system can be employed to measure both the temporal and the spatial distribution. Also, it is possible to calibrate the system for the measurement of accurate absolute concentration. Firstly, the system was tested at a calibration chamber for the determination of scattering cross section from propane, butane, acetylene, Freon-12 and Genetron 143a. After this, the system was adapted to a steady flow rig to measure the temporal and spatial fuel concentration. The rig is composed of cylinder head, intake manifold, injector, and transparent cylinder which can simulate internal combustion engine. To cope with the interference of Mie scattering, which is main obstacle of the measuring concentration with Rayleigh scattering, a hardware filter was installed for reducing the number density of particles. Furthermore a software filter was developed, which is based on the rise time and the time constant of the photomultiplier-amplifier system. In addition, background noisy was reduced by adjusting the optical array and applying the pin hall and beam trap. The results show that LRS can provide useful information about concentration field and the software filter is very effective method to remove Mie interference.

Lateral Cephalometric Measurements of Class I Malocclusion Patients with Uncertainty (불확도를 고려한 Class I 부정교합 환자의 측방두부방사선영상 계측값)

  • Lee, Ji Min;Song, Ji-Soo;Hyun, Hong-Keun;Kim, Young-Jae;Kim, Jung-Wook;Jang, Ki-Taeg;Lee, Sang-Hoon;Kim, Hojae;Cho, Hyo-Min;Shin, Teo Jeon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • 제45권1호
    • /
    • pp.65-74
    • /
    • 2018
  • The aim of this study was to obtain the traceability of the software used to analyze lateral cephalometry and to calculate the uncertainty of the measurements. Furthermore, this study aimed to provide a basis for obtaining standard references for measurement values for orthodontic treatment in children. Cephalometric data were collected from 100 children diagnosed with class I malocclusion between the ages 6 to 13 years who visited the pediatric dentist at Seoul National University Dental Hospital. To ensure traceability, a phantom device was created. Correction values were calculated by measuring the length and angle of the phantom device using the software. Type A uncertainty was calculated by obtaining the standard deviation of cephalometric measurements of 100 persons and the standard error of repeated measurements. Determination of the type B uncertainty was induced by minimum resolution and the position of the head. Using these, the combined standard uncertainty was obtained and the expanded uncertainty was calculated. The results of this study confirm that the currently used software has high accuracy and reliability. Furthermore, the uncertainty of orthodontic measurements in Korean children aged 6 to 13 years was calculated, and distribution range for class I malocclusion with 95% confidence interval was suggested.

A Comparative Study on the Head and Neck Radiation Therapy for Dynamic Conformal Arc Therapy and Volumetric Modulated Arc Therapy (두경부 방사선 치료 시 입체조형동적회전조사치료와 용적변조회전조사치료에 관한 연구)

  • Kim, Deok-Ki;Choi, CheonWoong;Choi, Jae-hyock;Won, Hui-su;Park, Cheol-soo
    • Journal of the Korean Magnetics Society
    • /
    • 제25권6호
    • /
    • pp.208-218
    • /
    • 2015
  • Recently, radiation therapy is used in the CT existing conventional two-dimensional radiation image, and set the size and location of the tumor in a manner that the image is going to change the treatment plan. After using the simulation using CT, radiation therapy it is four-dimensional or three-dimensional treatment made possible. and radiation therapy became the more effective ever before. High technology radiation therapy such as the treatment of SRS,IMRT, IGRT, SBRT, is a need to try contemplating the possibility to apply appropriate analysis and situation, so it has its own characteristics. and then it is believed that it is necessary to analyze and try it worries the proper applicability of the situation. The configuration of the various treatment that is applicable in many hospitals is necessary to try to determine how to practically apply the patients. Critical organs surrounding tumor give a small dose to avoid side effects and then the tumor has the therapeutic effect by providing a larger dose than before the radiation treatment.

Households' Characteristics, Forest Resources Dependency and Forest Availability in Central Terai of Nepal

  • Panta, Menaka;Kim, Kyehyun;Lee, Cholyoung
    • Journal of Korean Society of Forest Science
    • /
    • 제98권5호
    • /
    • pp.548-557
    • /
    • 2009
  • For centuries, forests have been a key component of rural livelihood. They are important both socially and economically in Nepal. Firewood and fodder are the basic forest products that are extracted daily or weekly basis in most of the rural areas in Nepal. In this study, a field survey of 100 households was conducted to examine the degree of forest dependency and forest resource availability, households' livelihood strategy and their relationship with forest dependency in Chitwan, Nepal. A household' response indexes were constructed, Gini coefficient, Head Count Poverty Index (HCI) and Poverty Gap Index (PGI) were calculated and one way ANOVA test was also performed for data analysis. Data revealed that 82/81% of all households were constantly used forest for firewood and fodder collection respectively while 42% of households were used forest or forest fringe for grazing. The Forest Product Availability Indexes (FPAI) showed a sharp decline of forest resources from 0.781 to 0.308 for a 20-yr time horizon while timber wood was noticeably lowered than the other products. Yet, about 33% of households were below the poverty threshold line with 0.0945 PGI. Income distribution among the household showed a lower Gini coefficient 0.25 than 0.37 of landholdings size. However, mean income was significantly varies with F-statistics=246.348 at P=0.05 between income groups (rich, medium and poor). The extraction of firewood, fodder and other forest products were significantly different between the income group with F-statistics=16.480, 19.930, 29.956 at P=0.05 respectively. Similarly, landholdings size and education were also significantly different between the income groups with F-statistics=4.333, 5.981 at P=0.05 respectively. These findings suggested that income status of households was the major indicator of forest dependency while poor and medium groups were highly dependent on the forests for firewood, fodder and other products. Forest dependency still remains high and the availability of forest products that can be extracted from the remaining forestlands is decreasing. The high dependency of households on forest coupled with other socioeconomic attributes like education, poverty, small landholders and so on were possibly caused the forest degradation in Chitwan.Therefore, policy must be directed towards the poor livelihood supporting agenda that may enhance the financial conditions of rural households while it could reduce the degree of forest dependency inspired with other income generating activities in due course.

Morphological Characteristics and Habitat Types of Rattus norvegicus and R. tanezumi Collected in Jeju Island (제주도에서 채집된 Rattus norvegicus와 R. tanezumi의 서식지 유형과 형태적 특성)

  • Kim, Tae-Wook;Joo, Sang-Min;Oh, Ah-Reum;Park, So-Jin;Han, Sang-Hyun;Oh, Hong-Shik
    • Korean Journal of Environment and Ecology
    • /
    • 제27권5호
    • /
    • pp.550-560
    • /
    • 2013
  • This study was investigated the morphological characters, secondary sexual dimorphism, and habitat patterns of Korean Rattus animals collected on Jeju Island from April 2005 to October 2012. Two wild rat species, namely R. norvegicus and R. tanezumi were identified on Jeju Island based on morphological characteristics and molecular data; however, R. rattus, which had recorded formerly, was not found in this study. Individuals of R. norvegicus were captured from urban, rural, and natural habitats, while those of R. tanezumi were specially found in animal farms and the surrounding areas. Comparing of morphological characters of two species, R. norvegicus had a shorter tail and ears than R. tanezumi (p<0.05), and the ratios of tail length and ear length to those of head-body length showed significantly differences between two species (p<0.05). The body weights (BW) of urban populations of R. norvegicus were significantly heavier than those of rural populations (p<0.05). No secondary sexual dimorphism was found in R. norvegicus, but females of R. tanezumi showed heavier BW than those of males (p<0.05). These findings suggest that it is necessary to revise the records for the existence of R. tanezumi and to confirm the animal fauna and elucidate the distribution and ecological characteristics from further studies using extensive sampling and detailed investigations on Jeju Island and also on the Korean Peninsula.

A Study on Mice Exposure Dose for Low-dose Gamma-irradiation Using Glass Dosimeter (유리선량계를 이용한 저선량 방사선의 마우스 피폭선량 연구)

  • Noh, Sung Jin;Kim, Hyo Jin;Kim, Hyun;Jeong, Dong Hyeok;Son, Tae Gen;Kim, Jung Ki;Yang, Kwangmo;Nam, Sang-Hee;Kang, Yeong-Rok
    • Journal of Radiation Protection and Research
    • /
    • 제40권4호
    • /
    • pp.202-210
    • /
    • 2015
  • The low dose radiation is done for a long period, thus researchers have to know the exact dose distribution for the irradiated mouse. This research has been conducted in order to find out methods in transmitting an exact dose to mouse in a mouse irradiation experiment carried out using $^{137}Cs$ irradiation equipment installed in the DIRAMS (Dongnam Institution of Radiological & Medical Sciences) research center. We developed a single mouse housing cage and shelf with adjustable geometric factors such as distance and angle from collimator. The measurement of irradiated dose showed a maximal 42% difference of absorbed dose from the desired dose in the conventional irradiation system, whereas only 6% difference of the absorbed dose was measured in the self-developed mouse apartment system. In addition, multi mice housing showed much difference of the absorbed dose in between head and body, compared to single mouse housing in the conventional irradiation system. This research may allow further research about biological effect assessment for the low dose irradiation using the self-developed mouse apartment to provide more exact doses which it tries to transmit, and to have more reliability for the biological analysis results.

Verification of Stereotactic Target Point Achieved by Acquisition of MR Image in Actual Treatment Position of Radiosurgery (정위적 방사선 수술시 치료위치에서의 정위적 표적점 확인을 통한 자기공명영상 획득의 정확도 연구)

  • 윤형근;신교철;김영식
    • Progress in Medical Physics
    • /
    • 제9권2호
    • /
    • pp.89-94
    • /
    • 1998
  • To make practical application of the MR image for stereotactic radiosurgery, the target point-achieved by acquisition of MR image in stereotactic radiosurgery planning system must agree with the actual isocenter of irradiation in real treatment. And the amount of distortion of the MR image must be known to make a correction for the agreement. A radish containing abundant water content was chosen as a homogeneous phantom for the purpose of verification of the agreement in this experiment. A dosimetric film was firmly attached to the small specially fabricated acryl plate and needle puncture was made through the film just into the acryl plate and a drop of oil was dropped into the hole of the film. The acryl plate with film was inserted into the radish and the dorp of oil represented the target point in MR image. After the image acquisition by stereotatic radiosurgery planning system, we achieved stereotactic coordinate of the target point represented by the oil drop. And we proceeded to actual irradiation to the target point according to the procedure of stereotactic radiosurgery. After the irradiation, the film in the radish was developed and processed and the degree of coincidence between the center of the radiation distribution and the target point represented by the hole in the film was measured. The discrepancy between two points was under 0.5 mm. so we could confirm good coincidence in homogeneous phantom such as radish. On the other hand, authors tried to use our home-made device for estimation of distortion of MR image.

  • PDF