• Title/Summary/Keyword: Head Distribution

Search Result 915, Processing Time 0.032 seconds

A Study on the Morphological Diagrgmmings of Four Constitutiens (사상인(四象人)의 형태학적(形態學的) 도식화(圖式化)에 관(關)한 연구(硏究))

  • Huh, Man Hoee;Song, Jeong-Mo;Kim, Dal-Rae;Go, Byeong-Hui
    • Journal of Sasang Constitutional Medicine
    • /
    • v.4 no.1
    • /
    • pp.107-148
    • /
    • 1992
  • The definitions of Four Constitution (Tae-Yang-In, So-Yang-In, Tae-Eum-In, So-Eum-In) in Four-Beginning-Theory (四端論) and Distribution-Theory (擴充論) were morphologically diagrammatized. the method of measuring the five parts came from the diagrams. The five parts are the followings; Top-Line is the distance between Rt. & Lt.Shoulders. Bosom-Line is the horizontal distance passing through the Rt. & Lt.nipples. Stomach-Line is the horizontal distance passing through the Rt. & Lt. acupuncture point Bool-Yong (不容穴). Navel-Line is the horizontal distance passing through the navel. Bottom-Line is the distance between the Rt.& Lt. anterior superior iliac spines. According to it, 311 people were measured in the clinic. Through the measured numerical values, to find out the objective propriety of the morphological diagrammings and the discriminating ability of Four Constitutions by the method of measuring the five, the author tried this study and got the following results. 1. On the ground of the Internal Organs-Theory (臟腑論), the definitions of Four Constitutions were classified and diagrammatized step by step and it was possible to draw the morphological graphs satisfying the reasonable condition objectively. 2. It was found that the graphings by Mean, Standard Deviation and 95% Confidence Interval for mean of the numerical values of five measured parts and the morphological diagrammings of the definitions in Four-Beginning Theory and Distribution-Theory drove to the same figures. 3. Through the method of the Analysis of variance and the Discriminant Analysis, it was discovered that the measured numerical values of five parts could distinguish the Four Constitutions. 4. Tae-Yang-In has the longest Top-Line and the shortest Bottom-Line. The Mean head of Confidence Interval from Top to Bottom is downwardly decreased at the rate of 3.7, 1.5, 1.8, 3.4. 5. So-Yang-In has the longest Top-Line and the shortest Bottom-Line. The Mean head of confidence Interval from Top to Bottom is downwardly decreased at the rate of 2.3, 1.5, 1.5, 1.1. 6. Tae-Eum-In has the longest Navel-Line. The Mean head of Confidence Interval from Navel to Top is upwardly decreased at the rate of 0.5, 0.4, 2.5 and downwardly decreased at the rate of 2.7 between Navel and Bottom. 7. So-Eum-In has the longest Bottom-Line. The Mean head of Confidence Interval from Bottom to Top is upwardly decreased at the rate of 1.1, 1.1, 1.8, 2.3. From the above findings, it was possible to draw the morphological graphings satisfying the objectively reasonable conditions in the definitions of Four-Beginning-Theory and Distribution-Theory and it was proved that the results of the Positive Analysis, carried with the measured numerical values of five parts from the diagramming, could show the objective propriety of the morphological graphings and the discerning ability of Four Constitutions by the method of measuring the five parts.

  • PDF

Evaluation of Sperm Penetration Ability according to Various Morphological Characteristics of Spermatozoa (정자의 여러가지 형태학적 특징에 따른 정자 침투능의 평가)

  • Kim, J.H.;Jung, K.W.;Lew, Y.O.;Kwon, D.J.;Lim, Y.T.;Kim, J.H.;Nha, D.J.;Lee, J.W.
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.21 no.1
    • /
    • pp.31-41
    • /
    • 1994
  • Morphological estimation of human spermatozoa is complicated by the fact that there is great natural variation in shape. This natural variation in shapes makes it difficult to say which forms are associated with infertility and which are normal variations. Possibly post coital test or in vitro cervical mucus penetration tests will help to clarify this question by showing which sperm are capable of penetration. The purpose of this investigation was performed to assess distribution of various morphological abnormalities according to the ability of sperm to penetrate cervical mucus. The sperm-mucus penetration using hen's egg white as substituting mucus for human cervical mucus was done in 45 fertile men with normal semen analysis and 122 infertile men with abnormal seminal parameters more than one. The female partners of 122 infertile couples showed normal results in the female fundamental test for fertility. Conventional semen analysis was evaluated according to the WHO standard normal(l980). The detailed classification of the abnormal sperm was made according to David et al(l975). The vitality of the sperm samples determined by eosin yellow-nigrosin stainig according to the method of Eliasson(l977). Results were as follw; 1. The patients had significantly lower total sperm count, motility (%), normal morphology (%), viability and total functional sperm fractions(TFSF) than fertile donors. 2. The mean value of sperm penetration distance of the patients(28.69${\pm}$11.02mm) showed significantly lower than fertile donors(37.33${\pm}$5.49mm). And 43/45 fertile donors(95.5%) as well as 57/122 patients(46.7%) had over 30mm in sperm penetration distance respectively. While 2/45 fertile donors(4.5 %) and 65/122 patient(53.3%) had under 30mm in sperm penetration distance respectively. 3. The morphological abnormalities in fertile donors were significantly lower 23.04${\pm}$5.83% (head = 12.89${\pm}$4.98, neck=6.11${\pm}$3.83%, and tail=3.43${\pm}$2.65%), compared to 36.03${\pm}$14. 40% in patients(head = 15.98 8.60%, neck 11.20${\pm}$6.56% and tail=8.70${\pm}$6.55%). Also, 3 types of sperm abnormalities including head, neck and tail were significantly lower in patient than fertile donors, respectively. Both the patients and fertile donors showed higher distribution of sperm with abnormal head than abnormal neck and tail. 4. The mean morphological abnormalities(SP>30mm) of the patients(30.68 11.64%; head = 15.95${\pm}$9.35%, neck=8.14${\pm}$4.21 %, tail=6.56${\pm}$5.64%) were significantly lower compared to patients(40.72${\pm}$15.01 %; head=16.02${\pm}$7.69%, neck 13.89${\pm}$7.82%, tail=1O.58${\pm}$6.75%) under 30mm in sperm penetration distance. Also, both groups over 30mm and under 30mm in sperm penetration showed distance higher distribution of sperm with abnormal head than abnormal neck and tail. The morphological abnormalities of head did not show significant difference but abnormal neck and tail were significant difference between the over 30mm and under 30mm group in sperm penetration distance.

  • PDF

Performance Characteristics of Small Tubular-type Hydroturbine according to the Guide Vane Opening Angle by Experiment and CFD (실험 및 CFD에 의한 가이드베인 개도에 따른 소형 튜블러 수차의 성능특성)

  • Nam, Sang-Hyun;Kim, You-Taek;Choi, Young-Do;Lee, Young-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.11 no.5
    • /
    • pp.44-49
    • /
    • 2008
  • As the alternative energy, renewable energy should have been developing by many techniques, in order to substitute the fossil fuel which will be disappeared in the near future. One of the small hydropower generator, main concept of tubular turbine is based on using the different water pressure levels in pipe lines, energy which was initially wasted by using a reducing valve at the end of the pipeline, is collected by turbine in the hydro power generator. A propeller shaped hydro turbine has been used in order to use this renewable pressure energy in order to acquire basic design data of tubular type hydraulic turbine, output power, head, efficiency characteristics due to the guide vane opening angle are examined in detail. First, it ensures the reliance of CFD by that of compared with experiment data. After all, the results of performance characteristics of the CFD and experiment show to confirm the data that power, head and efficiency of less than 4%, 2% and 5% respectively. Moreover influences of pressure, tangential and axial velocity distributions on turbine performance are investigated.

The Effect of Abdominal-Compression Belt on Balance Ability with One Leg Standing

  • Chang, Ki-Yeon;Chon, Seung-Chul
    • Journal of the Ergonomics Society of Korea
    • /
    • v.31 no.2
    • /
    • pp.337-343
    • /
    • 2012
  • Objective: The aim of this study was to determine the effect of abdominal-compression belt in one leg standing on balance in normal adult. Background: With the effects of increased intra-abdominal pressure, the abdominal-compression belt is contributing to a static balance control. However, specific study is still insufficient. Method: Forty subjects were randomly allocated to two groups: control(n=20) and experimental group(n=20), respectively. The experimental group used an abdominal-compression belt, whereas the control group did not that. All subjects were educated using pressure biofeedback unit and ultrasound imaging for exact application by abdominal-compression belt. Main outcome measurement was used a general stability index, fourier harmony index, weight distribution index, and fall index in tetrax balance system. Results: Experimental group improved significantly on general stability, only 2 factors(eyes closed with head turned forward and eyes closed with head turned backward) among fourier harmony index, and fall index, However, weight distribution index did not revealed significant difference. Conclusion: The findings suggest that application of abdominal-compression belt could be effective on improving balance ability in one leg standing of normal adults. Application: The results of the abdominal-compression belt might help to control balance in workers.

Improved Momentum Exchange Theory for Incompressible Regenerative Turbomachines (II) - Loss Model and Performance Prediction - (비압축성 재생형 기계에 대한 개선된 운동량 교환 이론 (II) - 손실 모델 및 성능 예측 -)

  • Park Mu Ryong;Chung Myung Kyoon;Yoo Il Su
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.10
    • /
    • pp.1247-1254
    • /
    • 2004
  • In momentum exchange theory the loss models for the circulatory flow is critically important. But because of lack of loss model on the circulatory flow, analysis model on regenerative turbomachines is not available in the open literature. In the present study circulatory loss is evaluated by combining bend's losses. Through the comparison with the previous experimental data on linear pressure gradient, a combination factor is suggested in terms of the aspect ratio of a channel. Applying this factor to two kinds of regenerative blowers the predicted results are found to be in good agreement with the experimental data of the overall performance and the head distribution along the rotational direction. Especially, the comparison with the head distribution demonstrates the accuracy of hydraulic model and loss model suggested in the present study. And the comparison with the overall performance confirms the validness of physical models as well as loss models suggested in the present study.

A Comparison of T Classification of the AJCC and Ho Staging Systems for Nasopharyngeal Carcinoma (비인강암에서 AJCC와 Ho 병기 결정법에 따른 T병기의 비교)

  • Lee Sang-Wook;Seo In-Seok;Kang Mee-Jeong;Cho Seok-Hyun;Kim Kyung-Rae;Lee Hyung-Seok
    • Korean Journal of Head & Neck Oncology
    • /
    • v.18 no.2
    • /
    • pp.179-183
    • /
    • 2002
  • Objective: A comparison of American Joint Committee on Cancer (AJCC) 1988 and 1997 nasopharyngeal carcinoma (NPC) classifications was made in terms of patient distribution and efficacy in predicting prognosis. Materials and Methods: Between Jan. 1981 and Dec. 1998, 60 cases of node negative nasopharyngeal carcinoma were retrospectively reviewed. The extent of disease each patients restaged according to the 4th and 5th AJCC system and Ho system, respectively. Results: The overall and disease free 5-year survival rates were 61.1% and 62.6%, respectively. Among T classifications of 4th AJCC, 5th AJCC and Ho staging system were not observed significantly different in disease-free survival rates, respectively. Conclusion: We observed a better patient distribution with AJCC 1997 comparing to AJCC 1988. The new classification also attained better statistical significances among stages in the overall survival and disease free survival rates was needed.

A Numerical Study on the Improvement of Performance for the 2 Vane Pump Impeller (2 Vane 펌프 임펠러의 성능 개선에 관한 수치해석적 연구)

  • KIM, SUNG;MA, SANG-BUM;CHOI, YOUNG-SEOK;KIM, JIN-HYUK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.31 no.3
    • /
    • pp.293-301
    • /
    • 2020
  • This paper describes a numerical study on the improvement of performance of the 2 vane pump impellers. The design of these impellers was optimized using a commercial computation fluid dynamics code and design of experiments. Geometric design variables were defined by the impeller blade angle distribution. The objective functions were defined as the total head, total efficiency and solid material size of the impellers. The importance of the geometric design variables was analyzed using 2k factorial designs. The interaction between the total head, total efficiency and solid material size, according to the impeller blade angle distribution, is discussed by analyzing the 2k factorial design results.

Internal Flow Analysis of a Tubular-type Small Hydroturbine by Runner Vane Angle

  • Nam, Sang-Hyun;Kim, You-Taek;Choi, Young-Do;Lee, Young-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.7
    • /
    • pp.1044-1050
    • /
    • 2008
  • Most of developed countries, the consumption of fossil fuels has been serious problems that cause serious environment pollution like acid rain, global warming. Also, we have faced that limitation fossil fuels will be exhausted. Currently, small hydropower attracts attention because of its small, clean, renewable, and abundant energy resources to develop. By using a small hydropower generator of which main concept is based on using the different water pressure levels in pipe lines, energy which was initially wasted by use of a reducing valve at the end of the pipeline, is collected by turbine in the hydropower generator. A propeller shaped hydroturbine has been used in order to use this renewable pressure energy. In this study, in order to acquire basic design data of tubular type hydraulic turbine, output power, head, efficiency characteristics due to the flow coefficient are examined in detail. Tubular-turbine among small hydraulic power generation can be used at low-head. The purpose of this study is to research turbine's efficiency due to runner vane angle using CFD analysis.

Effect of Oldenlandiae Herba in Calves with Diarrhea (송아지 설사증에 대한 백화사설초의 투여 효과)

  • Kim, Chang-Seob;Yun, Young-Min;Lee, Kyoung-Kap
    • Journal of Veterinary Clinics
    • /
    • v.23 no.4
    • /
    • pp.432-436
    • /
    • 2006
  • The therapeutic effects and immune responses with Oidenlandiae Herba administration(17.5%, 1g/30 kg, everyday, PO) were investigated in calves(1 to 3 months old) with diarrhea from 159 Korean native calves(76 heads from A farm and 83 heads from B farm) in Jeju. The causes of 47 calves with diarrhea were coronavirus(1 head) and rotavirus(1 head), coccidium(5 heads) and bacteria(40 herds). PCV values were significantly increased 2 weeks after administration of Oldenlandiae Herba in A form, compared by those of pre-treatment(p<0.05). However RBC, TP, WBC, fibrinogen levels were not significantly changed. The significant difference were not detected in changes of AST, BUN and creatinine. The CD14+ distribution rate were increased in 1 week after administration of Oldenlandiae Herba, compared by that of pre-treatment(p<0.05), however, certain tendencies of changes were not observed in distribution rates of CD4+ CD8+ and CD19+, respectively. The rate of death was 20.1%(36/179 calves) in 2004, however, it was decreased to 12.6%(20/159 calves) by Oldenlandiae Herba administration at 2 farms from Jeju in 2005. In conclusion, the administration of Oldenlandiae Herba was effective for treatment of calves with diarrhea.

Energy Distribution of X-rays from Medical Linear Accelerator (의료용 선형 가속기에서 발생된 X-선의 에너지 분포에 대한 고찰)

  • 김진기;김정홍;김부길
    • Progress in Medical Physics
    • /
    • v.2 no.1
    • /
    • pp.29-35
    • /
    • 1991
  • For accureate treatment planning, new models of dose calculations are being developed which require the knowledge of the energy spectra and angular distributions of the X-rays incident on the surface of the material. In this present study, we applied the Monte Carlo methods to the systematic analysis of the spectra distribution of X-ray beams produced by medical linear accelerator. As expected, the spectra become softer as the distance is farther from the central axis. also, its influenced by the geometrical dffect of head system.

  • PDF