• Title/Summary/Keyword: Head Cancer

Search Result 1,267, Processing Time 0.029 seconds

Influence of Parotid from Various Dose Rate in Intensity Modulated Radiation Therapy Planning for Head and Neck Cancer (두경부암 세기변조방사선치료 계획 시 선량율 변화가 이하선에 미치는 영향)

  • Hong, Joo-Wan;Jeong, Yun-Ju;Won, Hui-Su;Chang, Nam-Jun;Choi, Ji-Hun;Seok, Jin-Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.2
    • /
    • pp.105-111
    • /
    • 2010
  • Purpose: There are various beam parameter in intensity modulated radiation therapy (IMRT). The aim of this study is to investigate how various dose rate affect the parotid in treatment plan of IMRT. Materials and Methods: The study was performed on 10 nasopharyngeal carcinoma patients who have undergone IMRT. CT images were scanned 3 mm of thickness in the same condition and the treatment plan was performed by Eclipse (Ver.7.1, Varian, Palo Alto, USA). The parameters for planning used 6 MV energy and 8 beams under the same dose volume constraint. The variation of dose rates were used 300, 400, 500 MU/min. The mean dose of both parotid was accessed from the calculated planning among the 10 patients. The mean dose of parotid was verificated by 2D diode array (Mapcheck from Sun Nuclear Corporation, Melbourne, Florida). Also, Total monitor unit (MU) and beam-on time was analysed. Results: According to the dose rate, the mean dose of parotid was increased by 0.8%, 2.0% each, when dose rate was changed from 300 MU/min to 400, 500 MU/min, moreover Total MU was increased by 5.4% and 10.6% each. There was also a dose upward trend in the dose measurement of parotid by 2D diode array. However, beam - on time difference of 1~2 minutes was no signigicant in the dose rate increases. Conclusion: From this study, when the dose rates increase, there was a signigicant increase of Total MU and the parotid dose accordingly, however the shortened treatment time was not significant. Hence, it is considered that there is a significant decrease of late side effect in parotid radiation therapy, if the precise dose rate in IMRT is used.

  • PDF

Primary Radiation Therapy of Malignant Salivary Gland Tumors by Conventional Megavoltage Irradiation -Korea Cancer Center Hospital- (악성 타액선 종양의 방사선 치료 성적에 대하여 -원자력 병원의 10년 경험 ($1975.1{\sim}1984.12$)-)

  • Cho Chul Koo;Koh Kyoung Hwan;Yoo Seong Yul;Park Young Hwan;Park Woo Yoon;Shim Young Sang;Oh Kyung Kyoon
    • Radiation Oncology Journal
    • /
    • v.8 no.1
    • /
    • pp.35-43
    • /
    • 1990
  • Retrospective analysis of survival rates was undertaken in the patients of 58 cases treated with conventional radiation therapy for malignant salivary gland tumors between January 1975 and December 1984 in Korea Cancer Center Hospital (KCCH). They were patients whose long-term follow-up was possible and who had refused surgery or had had recurrences postoperatively. Out of 58 patients, 25 patients ($43.1\%$) had mucoepidermoid carcinomas and 24 patients ($41.3\%$) adenoid cystic carcinoma. Total actuarial survival rates at 5 years and 10 years were $68.2\%\;and\;31.8\%$ respectively, but disease-free survival rates, $43.2\%\;and\;13.0\%$, respectively. According to TNM stage, the survival rates at 5 years were $86.5\%$ in $T_1,\;40.0\%\;in\;T_2+T_3,\;and\;0\%\;in\;T_4$. In terms of histologic types, 5 years disease-free survival rate of adenoid cystic carcinomas ($40.1\%$) was lower than that of mucoepidermoid carcinomas ($49.8\%$) but overall survival rate ($77.3\%$) was much higher than that of mucoepidermoid carcinomas ($51.5\%$). There-fore, we concluded that the patients, who had had disease after failure of treatment, could survive during a certain period of time and their alive times were 2 years on the average. There was a difference in survival rates in the mucoepidermoid carcinomas in terms of histological grade of differentiation and it was a arbiter in prognosis: 5 YSR of low-grade was $78.8\%$ and higher 2 times than that of high-grade. There was no difference in survival rates according to location and sex. The number of patients having minor salivary gland tumors was 6 cases and their actuarial 5 YSR was $32.3\%$. Consequently, prognostic factors which influence the survival rates of patients with malignant salivary gland tumors are thought to be 1) histological subtypes 2) T and N staging (AJCC) 3) histological grade, especially in mucoepidermoids.

  • PDF

Study on the Photoneutrons Produced in 15 MV Medical Linear Accelerators : Comparison of Three-Dimensional Conformal Radiotherapy and Intensity-Modulated Radiotherapy (15 MV 의료용 선형가속기에서 발생되는 광중성자의 선량 평가 - 3차원입체조형방사선치료와 세기조절방사선치료의 비교 -)

  • Yang, Oh-Nam;Lim, Cheong-Hwan
    • Journal of radiological science and technology
    • /
    • v.35 no.4
    • /
    • pp.335-343
    • /
    • 2012
  • Intensity-modulated radiotherapy(IMRT) have the ability to provide better dose conformity and sparing of critical normal tissues than three-dimensional radiotherapy(3DCRT). Especially, with the benefit of health insurance in 2011, its use now increasingly in many modern radiotherapy departments. Also the use of linear accelerator with high-energy photon beams over 10 MV is increasing. As is well known, these linacs have the capacity to produce photonueutrons due to photonuclear reactions in materials with a large atomic number such as the target, flattening filters, collimators, and multi-leaf collimators(MLC). MLC-based IMRT treatments increase the monitor units and the probability of production of photoneutrons from photon-induced nuclear reactions. The purpose of this study is to quantitatively evaluate the dose of photoneutrons produced from 3DCRT and IMRT technique for Rando phantom in cervical cancer. We performed the treatment plans with 3DCRT and IMRT technique using Rando phantom for treatment of cervical cancer. An Rando phantom placed on the couch in the supine position was irradiated using 15 MV photon beams. Optically stimulated luminescence dosimeters(OSLD) were attached to 4 different locations (abdomen, chest, head and neck, eyes) and from center of field size and measured 5 times each of locations. Measured neutron dose from IMRT technique increased by 9.0, 8.6, 8.8, and 14 times than 3DCRT technique for abdomen, chest, head and neck, and eyes, respectively. When using IMRT with 15 MV photonbeams, the photoneutrons contributed a significant portion on out-of-field. It is difficult to prevent high energy photon beams to produce the phtoneutrons due to physical properties, if necessary, It is difficult to prevent high energy photon beams to produce the phtoneutrons due to physical properties, if necessary, it is need to provide the additional safe shielding on a linear accelerator and should therefore reduce the out-of-field dose.

Treatments Results and Prognostic Factors in Locally Advanced Hypopharyngeal Cancer (국소 진행된 하인두암의 치료 결과와 예후 인자 분석)

  • Yoon, Mee-Sun;Ahn, Sung-Ja;Nam, Taek-Keun;Song, Ju-Young;Nah, Byung-Sik;Lim, Sang-Cheol;Lee, Joon-Kyoo;Chung, Woong-Ki
    • Radiation Oncology Journal
    • /
    • v.25 no.3
    • /
    • pp.151-159
    • /
    • 2007
  • Purpose: The purpose of this study is to present the treatment results and to identify possible prognostic indicators in patients with locally advanced hypopharyngeal carcinoma. Materials and Methods: Between October 1985 to December 2000, 90 patients who had locally advanced stage IV hypopharyngeal carcinoma were studied retrospectively. Twelve patients were treated with radiotherapy alone, 65 patients were treated with a combination of chemotherapy and radiotherapy, and 13 patients were treated with surgery and postoperative radiotherapy with or without neoadjuvant chemotherapy. Total radiation dose ranged from 59.0 to 88.2 Gy (median 70 Gy) for radiotherpay alone. Most patients had ciplatin and 5-fluorouracil, and others had cisplatin and pepleomycin or vincristin. Median follow-up period was 15 months. Kaplan-Meier method was used for survival rate and Cox proportional hazard model for multivariate analysis of prognostic factors. Results: Overall 3-and 5-year survival rates were 27% and 17%, respectively. The 2-year locoregional control rates were 33% for radiotherapy alone, 32% for combined chemotherapy and radiotherapy, and 81 % for combined surgery and radiotherapy (p=0.006). The prognostic factors affecting overall survival were T stage, concurrent chemoradiation and treatment response. Overall 3-and 5-year laryngeal preservation rates in combined chemotherapy and radiotherapy were 26% and 22%, respectively. Of these, the 5-year laryngeal preservation rates were 52% for concurrent chemoradiation group (n=11), and 16% for neoadjuvant chemotherapy and radiotherapy (n=54, p=0.012). Conclusion: Surgery and postoperative radiotherapy showed better results than radiotherapy alone or with chemotherapy. Radiotherapy combined with concurrent chemotherapy is an effective modality to achieve organ preservation in locally advanced hypopharyngeal cancer. Further prospective randomized studies will be required.

Development of a Thermoplastic Oral Compensator for Improving Dose Uniformity in Radiation Therapy for Head and Neck Cancer (두경부암 방사선치료 시 선량 균일도 향상을 위한 Thermoplastic 구강 보상체의 개발)

  • Choi, Joon-Yong;Won, Young-Jin;Park, Ji-Yeon;Kim, Jong-Won;Moon, Bong-Ki;Yoon, Hyong-Geun;Moon, Soo-Ho;Jeon, Jong-Byeong;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.269-278
    • /
    • 2012
  • Aquaplast Thermoplastic (AT) is a tissue-equivalent oral compensator that has been developed to improve dose uniformity at the common boundary and around the treated area during radiotherapy in patients with head and neck cancer. In order to assess the usefulness of AT, the degree of improvement in dose distribution and physical properties were compared to those of oral compensators made using paraffin, alginate, and putty, which are materials conventionally used in dental imprinting. To assess the physical properties, strength evaluations (compression and drop evaluations) and natural deformation evaluations (volume change over time) were performed; a Gafchromic EBT2 film and a glass dosimeter inserted into a developed phantom for dose verification were used to measure the common boundary dose and the beam profile to assess the dose delivery. When the natural deformation of the oral compensators was assessed over a two-month period, alginate exhibited a maximum of 80% change in volume from moisture evaporation, while the remaining tissue-equivalent properties, including those of AT, showed a change in volume that was less than 3%. In a free-fall test at a height of 1.5 m (repeated 5 times as a strength evaluation), paraffin was easily damaged by the impact, but AT exhibited no damage from the fall. In compressive strength testing, AT was not destroyed even at 8 times the force needed for paraffin. In dose verification using a glass dosimeter, the results showed that in a single test, the tissue-equivalent (about 80 Hounsfield Units [HU]) AT delivered about 4.9% lower surface dose in terms of delivery of an output coefficient (monitor unit), which was 4% lower than putty and exhibited a value of about 1,000 HU or higher during a dose delivery of the same formulation. In addition, when the incident direction of the beam was used as a reference, the uniformity of the dose, as assessed from the beam profile at the boundary after passing through the oral compensators, was 11.41, 3.98, and 4.30 for air, AT, and putty, respectively. The AT oral compensator had a higher strength and lower probability of material transformation than the oral compensators conventionally used as a tissue-equivalent material, and a uniform dose distribution was successfully formed at the boundary and surrounding area including the mouth. It was also possible to deliver a uniformly formulated dose and reduce the skin dose delivery.

The Effects of Neck Irradiation on Thyroid Gland for Tumors of the Head and Neck -A prospective analysis of 75 cases- (두경부종양 환자에서 경부 방사선조사가 갑상선기능에 미치는 영향 -75예의 전향적 분석-)

  • Park In Kyu;Kim Sang Bo;Yun Sang Mo;Park Jun Sik;Jun Su Han;Kim Bo Wan
    • Radiation Oncology Journal
    • /
    • v.12 no.1
    • /
    • pp.59-66
    • /
    • 1994
  • Seventy-five patients with tumors of the head and neck treated with either radiation therapy alone or combined with surgery or chemotherapy were studied prospectively to evaluate the effects of radiation therapy to the neck on thyroid gland between September 1986 and October 1992. All patients were serially monitored for thyroid function tests before and after radiation therapy. Radiation dose to the thyroid gland ranged from 35 to 60 Gy with a median dose of 50 Gy. Median follow-up time was 30 months with a range of 11 to 85 months. The incidence of thyroid dysfunction was 40$ \% $: forty-five patients(60$ \% $) euthyroid, 2 patients(3$ \% $) clinical hypothyroidism, 27 patients(36$ \% $) subclinical hypothyroidism and 1 patient(1$ \% $) hyperthyroidism. No thyroid nodules or thyroid cancer were detected in any patients. Thyroid dysfunction appeared earlier in patients who underwent surgery than in those patients treated with radiation therapy alone or combination of chemotherapy and radiation therapy(P=0.0013). By multivariate analysis, risk factors that significantly influenced a higher incidence of thyroid dysfunction were female sex(p=0.0293) and combination of total laryngectomy and radiation therapy(p : 0.0045). In conclusion, evaluation of thyroid function before and after radiation therapy with periodic thyroid function tests are recommended to detect thyroid dysfunction in time and thyroid hormone replacement therapy is recommended whenever thyroid dysfunction develops.

  • PDF

Dosimetric evaluation of using in-house BoS Frame Fixation Tool for the Head and Neck Cancer Patient (두경부암 환자의 양성자 치료 시 사용하는 자체 제작한 BoS Frame 고정장치의 선량학적 유용성 평가)

  • Kim, kwang suk;Jo, kwang hyun;Choi, byeon ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.1
    • /
    • pp.35-46
    • /
    • 2016
  • Purpose : BoS(Base of Skull) Frame, the fixation tool which is used for the proton of brain cancer increases the lateral penumbra by increasing the airgap (the distance between patient and beam jet), due to the collision of the beam of the posterior oblique direction. Thus, we manufactured the fixation tool per se for improving the limits of BoS frame, and we'd like to evaluate the utility of the manufactured fixation tool throughout this study. Materials and Methods : We've selected the 3 patients of brain cancer who have received the proton therapy from our hospital, and also selected the 6 beam angles; for this, we've selected the beam angle of the posterior oblique direction. We' ve measured the planned BoS frame and the distance of Snout for each beam which are planned for the treatment of the patient using the BoS frame. After this, we've proceeded with the set-up that is above the location which was recommended by the manufacturer of the BoS frame, at the same beam angle of the same patient, by using our in-house Bos frame fixation tool. The set-up was above 21 cm toward the superior direction, compared to the situation when the BoS frame was only used with the basic couch. After that, we've stacked the snout to the BoS frame as much as possible, and measured the distance of snout. We've also measured the airgap, based on the gap of that snout distance; and we've proceeded the normalization based on each dose (100% of each dose), after that, we've conducted the comparative analysis of lateral penumbra. Moreover, we've established the treatment plan according to the changed airgap which has been transformed to the Raystation 5.0 proton therapy planning system, and we've conducted the comparative analysis of DVH(Dose Volume Histogram). Results : When comparing the result before using the in-house Bos frame fixation tool which was manufactured for each beam angle with the result after using the fixation tool, we could figure out that airgap than when not used in accordance with the use of the in-house Bos frame fixation tool was reduced by 5.4 cm ~ 15.4 cm, respectively angle. The reduced snout distance means the airgap. Lateral Penumbra could reduce left, right, 0.1 cm ~ 0.4 cm by an angle in accordance with decreasing the airgap while using each beam angle in-house Bos frame fixation tool. Due to the reduced lateral penumbra, Lt.eyeball, Lt.lens, Lt. hippocampus, Lt. cochlea, Rt. eyeball, Rt. lens, Rt. cochlea, Rt. hippocampus, stem that can be seen that the dose is decreased by 0 CGE ~ 4.4 CGE. Conclusion : It was possible to reduced the airgap by using our in-house Bos frame fixation tool for the proton therapy; as a result, it was possible to figure out that the lateral penumbra reduced. Moreover, it was also possible to check through the comparative analysis of the treatment plan that when we reduce the lateral penumbra, the reduction of the unnecessary irradiation for the normal tissues. Therefore, Using the posterior oblique the Brain cancer proton therapy should be preceded by decreasing the airgap, by using our in-house Bos frame fixation tool; also, the continuous efforts for reducing the airgap as much as possible for the proton therapy of other area will be necessary as well.

  • PDF

Mitochondrial DNA Mutation (3243A→G,1555A→4G,7445A→G) in Noise-Induced (소음성 난청에서의 Mitochondrial DNA A3243G, A1555G, A7445G 돌연변이)

  • Hong Young-Seoub;Nishio Hisahide;Lee Myeong-Jin;Kwak Ki-Young;Hwang Chan-Ho;Shin Dong-Hoon;Kwak Jong-Young;Lee Yong-Hwan;Kim Jong-Min;Kim Joon-Youn
    • Journal of Life Science
    • /
    • v.14 no.6 s.67
    • /
    • pp.913-919
    • /
    • 2004
  • Mitochondrial DNA mutations have been reported in recent years in association with sensorineural hering loss. The purpose of this study is to identify the association between the noise-induced sensorineural hearing loss and the A to G mutation at nucleotide 3243, 1555, 7445 of mitochondrial DNA. Study subjects were established by history and chart review, and audiological and clinical data were obtained. Blood was sampled from 214 normal controls, 102 noise-induced hearing loss, and 28 sensorineural hearing loss. The DNA of these individuals were extracted, and mitochondrial DNA fragments were analyzed by polymerase chain reaction. Subsequently, the coding sequence of mitochondrial DNA 3243, 1555, 7445 were sequenced, and compared to the normal sequence, and all sequence variations were analyzed by restriction enzymes. Mitochondrial DNA mutations $(3243A{\rightarrow}G,\;1555A{\rightarrow}4G,\;7445A{\rightarrow}G)$ were not detected by polymerase chain reactions in any patients with noise-induced hearing loss, sensorineural hearing loss, and normal controls. The DNA sequencing of PCR products did not revealed an A to G substitution at nucleotide 3243, 1555, 7445 of mitochondrial DNA. The noise-induced sensorineural hearing loss was not associated with mitochondrial DNA mutation $(3243A{\rightarrow}G,\;1555A{\rightarrow}4G,\;7445A{\rightarrow}G)$.

Evaluation of Skin Dose and Image Quality on Cone Beam Computed Tomography (콘빔CT 촬영 시 mAs의 변화에 따른 피부선량과 영상 품질에 관한 평가)

  • Ahn, Jong-Ho;Hong, Chae-Seon;Kim, Jin-Man;Jang, Jun-Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.1
    • /
    • pp.17-23
    • /
    • 2008
  • Purpose: Cone-beam CT using linear accelerator attached to on-board imager is a image guided therapy equipment. Because it is to check the patient's set-up error, correction, organ and target movement. but imaging dose should be cause of the secondary cancer when taking a image. The aim of this study is investigation of appropriate cone beam CT scan mode to compare and estimate the image quality and skin dose. Materials and Methods: Measurement by Thermoluminescence dosimeter (TLD-100, Harshaw) with using the Rando phantom are placed on each eight sites in seperately H&N, thoracic, abdominal section. each 4 methods of scan modes of are measured the for skin dose in three time. Subsequently, obtained average value. Following image quality QA protocol of equipment manufacturers using the catphan 504 phantom, image quality of each scan mode is compared and analyzed. Results: The results of the measured skin dose are described in here. The skin dose of Head & Neck are measured mode A: 8.96 cGy, mode B: 4.59 cGy, mode C: 3.46 cGy mode D: 1.76 cGy and thoracic mode A: 9.42 cGy, mode B: 4.58 cGy, mode C: 3.65 cGy, mode D: 1.85 cGy, and abdominal mode A: 9.97 cGy, mode B: 5.12 cGy, mode C: 4.03 cGy, mode D: 2.21 cGy. Approximately, dose of mode B are reduced 50%, mode C are reduced 60%, mode D are reduced 80% a point of reference dose of mode A. the results of analyzed HU reproducibility, low contrast resolution, spatial resolution (high contrast resolution), HU uniformity in evaluation item of image quality are within the tolerance value by recommended equipment manufacturer in all scan mode. Conclusion: Maintaining the image quality as well as reducing the image dose are very important in cone beam CT. In the result of this study, we are considered when to take mode A when interested in soft tissue. And we are considered to take mode D when interested in bone scan and we are considered to take mode B, C when standard scan. Increasing secondary cancer risk due to cone beam CT scan should be reduced by low mAs technique.

  • PDF

Burden, Job Satisfaction and Quality of Life of Nurses Caring for Cancer Patients (암 환자를 돌보는 간호사의 부담감, 직무 만족도 및 삶의 질)

  • Park, Mi-Sun;Yoo, Yang-Sook
    • Journal of Hospice and Palliative Care
    • /
    • v.8 no.1
    • /
    • pp.8-17
    • /
    • 2005
  • Purpose: This study was performed to investigate burden, job satisfaction and quality of life of nurses who take care of cancer patients. Methods: The subjects were 237 nurses working at the oncology unit of hospitals with over 500 beds in Seoul and Gyeonggi-do. Data were collected using questionnaire from the February to March, 2005. Data were analyzed through t-test, ANOVA, Pearson's correlation coefficient and stepwise multiple regression using SAS. Results: 1. The item that showed the highest level of burden was 'I feel limited even if I make efforts to reduce patients' pain. 'Burden was high in those group both who were younger than 35 years old and who had clinical experiences caring cancer patients for $3{\sim}4$ years. 2. The item that showed the lowest level of job satisfaction was 'the possibility of promotion'. Job satisfaction was high in those group both who had a spouse and were head nurses or incharge nurses. 3. The item that showed the lowest level of quality of life was 'I am physically exhausted'. Over 35 years old who had a spouse, and over 2,000,000 won monthly income made a high score in the quality of life. 4. There were negative correlations among burden, iob satisfaction and the quality of life. 5. The major factor affecting the quality of life was burden. Conclusion: The results of this study are expected to be utilized as basic data for developing support system to improve nurses' work conditions and quality of life.

  • PDF