• 제목/요약/키워드: HeNe

검색결과 448건 처리시간 0.026초

Sensitization of Periodontitis Disease Causing Bacteria by Low Power He-Ne Laser Radiation

  • Satsangi, Akash Tripathi;Mathur, Manish;Saxena, Parul;Prasad, Guru;Shrivastava, Jitendra Nath;Shrivastava, Jenendra Nath;Roy, Sukhdev
    • Journal of Photoscience
    • /
    • 제11권2호
    • /
    • pp.55-59
    • /
    • 2004
  • The present investigation is an attempt to create an optimized protocol for a bactericidal modality of different powers of He-Ne laser radiation to eliminate periodontitis disease causing bacteria from dental plaques. Periodontitis is most prevalent infectious disease of men and caused by a limited number of Gram negative oral bacteria. Porphyromonas gingivalis and Streptococcus sanguis are the important bacteria responsible for periodontitis diseases. Effect on periodontitis disease causing bacteria were produced by the exposure of different powers of He-Ne laser light i.e. 9 mW, 17 mW and 26 mW of red colour of wavelength 632.8 nm in two different periods of time i.e. 10 min. and 20 min. in the presence of dye Methylene blue (MB) used as a photosensitizer. The results have been shown in terms of percentage inhibition of colony forming units (cfu.) of bacteria. This study has shown that maximum inhibition of cfu. were observed in Laser+MB-20 min. exposure time. This inhibition was followed by Laser+MB-10 min., but minimum inhibition was seen in Laser only at 10 min. exposure. In case of effect of methylene alone on the cfu. of bacteria, it was seen that MB have not shown more inhibition of cfu. and it had shown that the no. of cfu. are very similar to that of control. The above observation of the present study was seen in case of every 3 different type of used powers of laser for both the bacteria. Maximum percentage inhibition of cfu. were seen in case of 26mW powers of He-Ne laser, which was 67. 28% to 61.42% for Porphyromonas gingivalis and Streptococcus sanguis respectively. So, increasing the power of laser (safe range for dentistry is 3-30 mW) under conditions shows an increased percentage inhibition of cfu. Thus the present investigation may be a useful adjunct with mechanical debridement in the prevention of recolonization of subgingival lesions by pathogenic microorganisms which are harmful and drug resistant.

  • PDF

비강질환에 대한 향기흡입과 He-Ne 레이저 병행 치료의 효과 및 예후 (Effect and Prognosis of Combined Essential Oil Inhalation and He-Ne Laser Treatment of Nasal Diseases)

  • 정선희;이승연
    • 대한한방소아과학회지
    • /
    • 제17권2호
    • /
    • pp.149-160
    • /
    • 2003
  • Objective : Essential oil inhalation and He-Ne laser treatment has become increasingly available in children with nasal diseases. But the reports on the effect and prognosis have been poor. In this study, we analyzed the treatment effect, recurrence rate and the degree of recurrent symptoms. Materials/Methods: 23 children(2-10 year-old) with nasal diseases, who received essential oil inhalation with He-Ne laser treatment at least 10 times in our hospital from January 1st 2001 to December 31th 2002 were studied. Result : Ten cases are male & thirteen cases are female. The average of age was 4.91 year-old. The most frequency symptoms are nasal discharge (82.6%), nasal obstruction (78.3%), cough (47.8%), secretion sound (39.1%), sneezing (17.4%). Average numbers of treatment period, interval and treatment times are 71.79 days, 4.06 days, 18.13 times respectively. Of the 23 children, 14 children were in 'all symptom improved' at the remedial ends, and 22 children relapsed. In the degree of recurrent symptoms, 15 children were in 'more improved then before-treatment and not equal to directly remedial ends'. No case was in 'worse than before-treatment'. The final result of treatment, 6 children keep the degree of remedial ends, on the other hand 17 children are not. Conclusions : Even though, the recurrence rate was high, this combined treatment improve nasal symptoms. The final assessment is good, when the treatment-result is good, when the treatment interval is regular and when parent's are cooperative. If the symptoms continue a whole year, the result is not so good.

  • PDF

정맥혈관내(靜脈血管內) 헬륨-네온 레이저 조사(照射)가 메리디안 심(心)·순환(循環) 대표점(代表點)과 고지혈증(高脂血症)에 미치는 영향(影響) (Effects of Intravenous He-Ne Laser Irradi on Meridian-Heart·Circulation CMP and Hyperlipidemia)

  • 안수기;이삼로;황우준
    • 사상체질의학회지
    • /
    • 제10권1호
    • /
    • pp.269-284
    • /
    • 1998
  • The purpose of this study was to investigate the effect of ILIB(Intravenous Laser Irradiation of blood) on Meridian-Heart Circulation CMP and Hyperlipidemia. Circulatory symptom of 20 patients was treated with ILIB. After 10 times' treatment, changes of total cholesterol, HDL-cholesterol, triglyceride and Meridian-Heart Circulation CMP value were observed. The results were as follows : 1. In observation of Meridian-Heart Circulation CMP value, significant increase was observed in both pre-ID generation and post-ID generation. So, distinctive observation between pre-ID generation and post-ID generation became not relatively significant. 2. In observation of Meridian-Heart Circulation CMP value, significant increase was observed in both left and right. So, distinctive observation between left and right became not relatively significant. 3. In observation of Meridian-Heart CMP value, significant increase was not observed in control group, but significant increase close to normal value was observed in treatment group after treatment of Intravenous He-Ne Laser Irradiation. 4. In observation of Meridian-Circulation CMP value, significant increase was not observed in control group, but significant increase close to normal value was observed in treatment group after treatment of Intravenous He-Ne Laser Irradiation. 5. In concentration of plasma total cholesterol and plasma triglyceride, significant decrease was not observed in control group, but significant increase was observed in treatment group after treatment of Intravenous He-Ne laser Irradiation. 6. Significant concentration change of plasma HDL-cholesterol was not observed in both control group and treatment group. From above results, it was thought that Intravenous He-Ne Laser Irradiation was significant effect on heart circulatory system in human body.

  • PDF

Two Versions of He-Ne Laser 3.39 μm with Radio Frequency Excitation

  • Kopica, Miroslaw;Choi, Jong-Woon
    • Journal of the Optical Society of Korea
    • /
    • 제12권1호
    • /
    • pp.31-37
    • /
    • 2008
  • To increase output power of a He-Ne laser we propose to use the capacitive rf discharge and implement four channel structure. Most of experiments were carried out with a single laser tube from this structure to optimize the output mirror transmission, pressure and composition of the mixture. A laser tube of 2.8 mm inner diameter and 50 cm discharge length can give an output power of above 5.5 mW at 3.39 ${\mu}m$. Four such tubes in "matrix" structure let us obtain 20 mW of output. Simplified models which can be used to evaluate the behavior of an equivalent electrical circuit with laser plasma and qualitative characteristics of output power of He-Ne laser were also described.

2-종 모드 레이저를 이용한 고분해능 헤터로다인 간섭계 (A High-Resolution Heterodyne Interferometer using Beat Frequency between Two-Axial Modes of a HeNe Laser)

  • 김민석;김승우
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 추계학술대회 논문집
    • /
    • pp.214-219
    • /
    • 1997
  • We propose a new scheme of high-resolution heterodyne interferometer that employs the two-axial mode He-Ne laser with an inter-mode beat frequency of 600-1000 MHz. An electronic RF-heterodyne circuit lowers the beat frequency down to 5 MHz, so that the phase change of the interferometer output is precisely measured with a displacement resolution of 0.1 nanometer without significant loss of dynamic bandwidth. A thermal control scheme is adopted to stabilize the cavity length with aims to suppress frequency drifts caused by the phenomena of frequency pulling and polarization anisotropy of the two-axial mode laser to a stability level of 2 parts in $10^9$. The two-axial mode HeNe laser yields a high output power of 2.0 mW, whlch allows us to perform multiple measurements of up to 10 machine axes simultaneously.

  • PDF

간섭계용 헬륨-네온 레이저의 주파수 안정화 (Frequency stabilization of HeNe laser for interferometry)

  • 주기남;김승우
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.260-263
    • /
    • 2003
  • Lasers are used as the source of the interferometers in the industrial field. These lasers need 2 requirements. The first is the narrow linewidth of laser for the long coherence length. The second is the stabilized frequency of laser for the precision measurement. Now HeNe lasers are mostly used and the frequency stability is about 10$^{-9}$ . In this paper, we construct the HeNe laser systems of frequency stabilization using typical 2 method, the beat frequency stabilization method and the intensity difference method. So, we get the frequency stabilities of 2.01$\times$10$^{-9}$ (0.1s), 3.4$\times$10$^{-9}$ (0.1s).

  • PDF

A Comparison Study of the Effect of Adding Ar or Kr Gas into the Conventional Gas Mixtures in a Matrix Type PDP

  • Khorami, Alireza;Ghanbari, Shirin
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.748-751
    • /
    • 2009
  • This paper provides a novel scheme to enhance luminous efficiency within Plasma Display Panels (PDPs). The He-Xe or Ne-Xe mixtures are mainly used in conventional PDP cells, where their discharge characteristics exemplify different behavior. Significantly, the excitation efficiency in He-Xe is lower than that of the Ne-Xe mixture. This paper demonstrates that by adding a small quantity of Ar or Kr gas in Ne-Xe mixture increases cell efficiency, while for the He-Xe mixtures their cell efficiency is reduced.

  • PDF

Holographic Grating Erasing Characteristics by Non-polarized Beam in Amorphous Chalcogenide Thin Films

  • Lee, Ki-Nam;Park, Jeong-Il;Chung, Hong-Bay
    • Transactions on Electrical and Electronic Materials
    • /
    • 제7권3호
    • /
    • pp.141-144
    • /
    • 2006
  • In the present work, we investigated the holographic grating erasing method by means of the optical method. It was formed the grating under the interference of holographic recording He-Ne laser beams on chalcogenide $As_{40}Ge_{10}Se_{15}S_{35}$ thin film with various film thickness and erased the holographic grating by non-polarized He-Ne laser beam. As the results, the recording grating erased the 80 % of formed grating by non-polarized He-Ne laser beam. It was confirmed that the erasing characteristics by non-polarized laser beam need to improve the focusing of beam and the control of beam intensity. And then it can be expected as the application possibility of rewritable holographic memory technology.

입사빔의 파장에 따른 AsGeSes & Ag/AsGeSes 박막의 홀로그래픽 데이터 소거특성 (Holographic Data Grating Formation of AsGeSeS Single & Ag/AsGeSeS Double Layer Thin Films with the Incident Beam Wavelength)

  • 구용운;정홍배
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 C
    • /
    • pp.1428-1429
    • /
    • 2006
  • We investigated the diffraction efficiency, erasing property and rewriting property of diffraction grating with each wavelength of recording beam. A (P:P) polarized light was exposed on AsGeSeS and Ag/AsGeSeS thin film to form a diffraction grating by HeNe(635nm) laser and DPSS(532nm) laser. At the maximum efficiency condition, unpolarized HeNe laser beam was irradiated to erase 1ha generated diffraction grating. The HeNe laser showed more higher diffraction efficiency and the DPSS laser showed more faster diffraction grating time. At erasing and rewriting process, AsGeSeS(61%-85%)thin film showed better property than Ag doped Ag/AsGeSeS(53%-63%) double layer structured thin film.

  • PDF

광소자와 헬륨-네온 레이저를 이용한 디스크 캠의 진동 측정 (Measurement of Vibration of Rotating Disk Cam Using He-Ne Laser and Photodiode)

  • 유웅재;이규섭;김재도
    • 한국정밀공학회지
    • /
    • 제12권10호
    • /
    • pp.69-77
    • /
    • 1995
  • This laser measurement system has been developed using He-Ne laser and photodiode. The laser beam intensity transmitted on a photodiode was disturbed by eccentrically rotating disk cam with various speeds. The photodiode and an amplifier were used to change the detected beam intensity into voltage. The digitized data through the developed system were recorded on a micro-computer by using a signal analysis program. Its reliability was ascertained by using FFT analyzer. The vibration of rotating disk cam can be analyzed by measureing the intensity change of laser beam which the results by FFT analyzer were similar to. The amplifier was devised to be able to modulate the fluctuations of laser beam. The voltage could be linearly recorded with the change of the laser beam intensity.

  • PDF