• Title/Summary/Keyword: He-Ne laser

Search Result 323, Processing Time 0.029 seconds

Pitch Measurement of 150 nm 1D-grating Standards Using an Nano-metrological Atomic Force Microscope

  • Jonghan Jin;Ichiko Misumi;Satoshi Gonda;Tomizo Kurosawa
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.5 no.3
    • /
    • pp.19-25
    • /
    • 2004
  • Pitch measurements of 150 nm one-dimensional grating standards were carried out using a contact mode atomic force microscopy with a high resolution three-axis laser interferometer. This measurement technique was named as the 'nano-metrological AFM'. In the nano-metrological AFM, three laser interferometers were aligned precisely to the end of an AFM tip. Laser sources of the three-axis laser interferometer in the nano-metrological AFM were calibrated with an I$_2$ stabilized He-Ne laser at a wavelength of 633 nm. Therefore, the Abbe error was minimized and the result of the pitch measurement using the nano-metrological AFM could be used to directly measure the length standard. The uncertainty in the pitch measurement was estimated in accordance with the Guide to the Expression of Uncertainty in Measurement (GUM). The primary source of uncertainty in the pitch-measurements was derived from the repeatability of the pitch-measurements, and its value was about 0.186 nm. The average pitch value was 146.65 nm and the combined standard uncertainty was less than 0.262 nm. It is suggested that the metrological AFM is a useful tool for the nano-metrological standard calibration.

A Study on the Development of a Low-cost Device for Measuring the Optical Smoke Density (광학적 연기밀도 측정을 위한 저가형 장치의 개발에 관한 연구)

  • Kim, Bong-Jun;Cho, Jae-Ho;Hwang, Cheol-Hong;Park, Seul-Hyun
    • Fire Science and Engineering
    • /
    • v.29 no.4
    • /
    • pp.81-88
    • /
    • 2015
  • A low-cost device using the light-extinction method was developed to measure the optical smoke density in various fire experiments in the present study. The relative measurement accuracy of low-cost device was evaluated through the comparison of optical density measured by a high-cost standard device consisting of He-Ne laser, photo detector and various optical components. The low-cost device was composed of laser module, photocell and acrylic board. From the experiments using a smoke generator can be easily adjusted the smoke concentration, it was found that the low-cost device could measure the smoke density within the range of ${\pm}10%$, compared to the standard device. In addition, the reliability of low-cost device was also confirmed in the experiment using a polyethylene flame. Finally, it is expected that the low-cost device developed with real-time measurement and simple installation for measuring the smoke density will be used instead of the high-cost standard device.

Two-wave mixing in Ce:$BaTIO_3$, Mgo:$LiNbO_3$ and :$LiNbO_3$ crystals (Ce:$BaTIO_3$, Mgo:$LiNbO_3$와 Fe:$LiNbO_3$ 결정에서의 이광파혼합 실험)

  • 주원제;박주형;곽장만;오차환;송석호;한양규;김필수
    • Korean Journal of Optics and Photonics
    • /
    • v.9 no.6
    • /
    • pp.423-427
    • /
    • 1998
  • Two wave mixing experiments in $LiNbO_3$, $BaTiO_3$ are carried out, and the characteristics as optical information processing device are investigated. Examined crystals are commonly used ones, such as 0.03% mol Ce-doped $BaTiO_3$, 0.03% mol Fe-doped $LiNbO_3$, and 6% mol MgO-doped $LiNbO_3$. $Ar^+$ ion laser is used as the writing beam, and He-Ne Laser is used as the reading beam. The recording-decay and erasing characteristics of diffraction gratings, the time constants, and also the angular selectivities are measured for each crystals and compared.

  • PDF

Effects of Low Level Laser Therapy on serum lipid and liver function in hyperlipidemia.obese Rats induced by high fat diet (저준위 레이져 요법이 고지방식이(高脂肪食餌)로 유발(誘發)된 고지혈증(高脂血症).비만백서(肥滿白鼠)의 혈청지질(血淸脂質) 및 간기능(肝機能)에 미치는 영향(影響))

  • Youn, Dae-Hwan;Lee, Yu-Kyung;Choi, Dong-Hee;Kim, Sung-Chul;Na, Chang-Su
    • Korean Journal of Acupuncture
    • /
    • v.21 no.4
    • /
    • pp.53-68
    • /
    • 2004
  • Objectives : Laser therapy started in 1958 when Schawlow and Townes suggested medical value of Laser therapy. He-Ne laser has been utilized as a clinical treatment for various diseases by Plog since 1975. Low Level Laser Therapy (LLLT) has been used as medication for controlling obesity in the Korean Medicine. So this study is planned to investigate the effects of LLLT on the level of serum lipid and weight gain Methods : Experimental groups were divided into normal group(Normal), high fat diet group(Control), high fat diet and LLLT by helium-neon (He-Ne) on the tail is carried out once a 2 day during 5 weeks. The animals were divided into six groups: no ischemia-induced and no LLLT-treated group (Normal), the ischemia-induced and no LLLT-treated group (Control), the ischemia-induced and 5 mW 5 min LLLT-treated group (LLLT5-5), the ischemia-induced and 30 mW 5 min LLLT-treated group (LLLT30-5), the ischemia-induced and 5 mW 10 min LLLT-treated group (LLLT5-10), 30 mW 10 min LLLT-treated group (LLLT30-10). The effect of LLLT is observed by weight gain, food intake, food efficiency, serum of lipid concentrations, liver function and HDL to total cholesterol ratio of rats fed high fat diet for 5weeks. Results : Body weight and food intake were decreased in LLL5-5, LLLT30-5, LLLT30-10. Food efficiency was decreased in LLLT30-10. The level of serum Triglyceride, Free fatty acid, AST, ALT, ALP were decreased in LLLT30-10. Serum HDL-cholesterol was increase in LLLT5-10, LLLT30-10. Also serum ALT was decrease in LLLT5-5 Conclusions : LLLT(30 mW-10 min) is effective on Body weight, food efficiency ratio, the level of serum lipid and protection of liver function by obesity induced by high fat diet, and LLLT(5 mW-5 min) act on decrease of Body weight, food intake and ALT.

  • PDF

A Study on the Attenuation of Surface Acoustic Waves by Optical Measurement Method (광학적 측정방법에 의한 표면 탄성파의 감쇠에 관한 연구)

  • You, I.H.;Kim, D.I.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.14 no.4
    • /
    • pp.237-243
    • /
    • 1995
  • We have studied methods of detecting attenuation of solid materials such as silicon wafer and piezoelectric $LiTaO_3$ by means of optical probing techniques. We have performed measurements of surface acoustic waves(SAW) generated from 90 degree wedge type transducer and also from inter-digital transducers(IDT). SAW of 20.0 MHz was generated on a silicon wafer from the 90 degree wedge type transducer and those of 20.8 and 14.5 MHz are generated on a $LiTaO_3$ from the IDT. Then any surface-corrugation resulted from the above SAW was investigated by He-Ne laser beams. We projected laser beams, which were modulated by an optical chopper, on the SAW of the same frequency and then measured the scattered beam by the lock-in amplifier. We modulated and synchronized both SAW and the incident laser beam as well as the phase sensitive detector(PSD) to the same frequency in order to simplify our measurement system. We obtained the attenuation coefficients of SAW to be $0.62{\sim}0.75dB/mm$(from IDT1, 20.8 MHz), and $0.60{\sim}0.72dB/mm$(from IDT2, 14.5 MHz), $0.83{\sim}1.28dB/mm$(from the wedge type), respectively.

  • PDF

The development of laser doppler vibrometer using DPLL for the detection of ultrasonic vibration (Digital PLL을 이용한 초음파진동 측정용 레이저 도플러 진동계의 개발)

  • 김호성
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.5
    • /
    • pp.306-311
    • /
    • 2000
  • This paper deals with the development of Laser Doppler Vibrometer (LDV) that can mea~ure the tlequency and amphlude of the ultrasonic vibralion. Hc-Ne laser (632.8 om) is used as a light source, and Michelson interferometer in winch frequency of the objective beam is shIfted by Bragg cell IS adopted The frequency modulated signal centered at 40 MHz flom the PIN diode IS amplified. down-col1vel1ed to 2.5 MHz, filtered and digiLized. The voltage output that is proportional to the velocity of the vibratwg surface is obtawed using digItal PLL. A microprocessor is used to extract the frequcncy aud amplitude of the vibratIOn from the voltage output. It is found that the developed LDV can measure up to 300 kHz vibratIOn and the mlillmUITI measurable amplitude is I nm at 300 kHz. We believe thatlhis LDV can be used to measure the vibratIOn of the heavy electric maclllnery and micro-size structures. tures.

  • PDF

The Effects of Laser Irradiation on Human Plasma $\beta-endorphin$ Levels (Laser가 정상인의 혈장내 $\beta-endorphin$ 농도에 미치는 영향)

  • Seo Yeon-Soon;Park Rae-Joon;Park Young-Han
    • The Journal of Korean Physical Therapy
    • /
    • v.9 no.1
    • /
    • pp.157-166
    • /
    • 1997
  • The purpose of this study was to determine the effects of laser Irradiation on Human plasma $\beta-endorphin$ levels, by treating with low level helium-neon (He-Ne) and Infrared(lR) laser. The Laser was fixed frequency of 2400Hz by continuous scanning and irradiating time was 8 minutes each point. Blood samples were taken at before, after, after 15min's treatment and Plasma $\beta-endorphin$ was measured by radioimmunoassay. The samples for this study were 6 normal subjects(3male, 3female). The data were analyzed by paired t-test, one-way ANOVA and simple regression. The results of this study were as follows : 1. The human plasma $\beta-endorphin$ levels were noted as significant increase in after-treatment $(22.84{\pm}10.63pg/ml)$ as compared with before-treatment $(16.96{\pm}9.23pg/ml)$ and significant increase in after 15min's $(27.27{\pm}8.81pg/ml)$ as compared with after-treatment (p<0.05). 2. There were no significant changes in plasma g-endorphin levels between male and female. 3. The human plasma $\beta-endorphin$ levels were high associated in between session reliability (p<0.05).

  • PDF

150 nm Pitch Measurement using Metrological AFM (길이 소급성을 갖는 AFM을 이용한 150nm 피치 측정)

  • ;I. Misumi;S. Gonda;T. Kurosawa
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.264-267
    • /
    • 2003
  • Pitch measurements of 150 nm pitch one-dimensional grating standards were carried out using an contact mode atomic force microscopy(C-AFM) with a high resolution three-axis laser interferometer. It was called as 'Nano-metrological AFM' In Nano-metrological AFM, Three laser interferometers were aligned well to the end of AFM tip. Laser sources of the three-axis laser interferometer in the nano-metrological AFM were calibrated with an I$_2$-stablilzed He-Ne laser at a wavelength of 633 nm. So, the Abbe error was minimized and the result of the pitch measurement using the nano-metrological AFM has a traceability to the length standard directly. The uncertainty in the pitch measurement was estimated in accordance with the Guide to the Expression of Uncertainty in Measurement(GUM). The Primary source of uncertainty in the pitch-measurements was derived from repeatability of pitch-measurement, and its value was approx 0.186 nm. Expanded uncertainty(k=2) of less than 5.23 nm was obtained. It is suggested that the metrological AFM is a useful tool for the nano-metrological standard calibration.

  • PDF

A Study on the Holographic Process for Photonic Crystal Fabrication (광자결정 제작을 위한 홀로그라피 공정 연구)

  • Yeo, Jong-Bin;Yun, Sang-Don;Lee, Hyun-Yong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.8
    • /
    • pp.726-730
    • /
    • 2007
  • Two dimensional photonic crystals (2D PCs) have been fabricated by a double exposure holographic method using a He-Cd laser with a wavelength of 442nm. The arrays of the 2D PCs exhibit variable lattice structures from square to triangle according to a change of rotating angle $({\gamma})$ for double exposure beams. In addition, the period and filling factor of PCs as well as the forms (dot or antidot) could be controlled by experimental conditions. $A l.18-{\mu}m-thick$ resist was spin-coated on Si substrate and the 1st holographic exposure was carried out at incident angle $({\theta})$ of $11^{\circ}$. Then the sample was rotated to ${\gamma}=45^{\circ}{\sim}90^{\circ}$ and the 2nd holographic process was performed at ${\theta}=11^{\circ}$. The variation of diffraction efficiency during the exposure process was observed using a He-Ne laser in real time. The images of 2D PCs prepared were analyzed by SEM and AFM. We believe that the double holographic method is a tool suitable to realize the 2D PCs with a periodic array of large area.

Fabrication of photonic quasicrystals using multiple-exposure holographic method and bandgap properties (다중-노출 홀로그라피 방법을 이용한 광자 준결정 제작 및 밴드갭 특성)

  • Yun, Sand-Don;Yeo, Jong-Bin;Lee, Hyun-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.8-8
    • /
    • 2008
  • Two-dimensional photonic quasicrystal (PQCs) template patterns have been fabricated on a $1.1{\mu}m$-thick DMI-150 photoresist using a multiple-exposure holographic method. A 442-nm HeCd laser was utilized as a light source and the holographic exposure was carried out at a fixed angle of $\theta=6^{\circ}$. After the first holographic exposure, the sample was rotated to a proper angle and the second exposure was performed to the same manner. This exposure process was repeated n/2 times to obtain n-fold symmetric PQC patterns and then the sample was developed. The fabricated PQCs exhibited 8, 10 and 12-fold rotational symmetry and the diffraction patterns using a 632.8-nm HeNe laser were observed for n-rotation symmetry corresponding n-fold PQCs. The fabricated PQC template patterns were examined using scanning electron microscopy(SEM). Transmission spectra were measured fourier transform infrared(FTIR) spectrometer.

  • PDF