• Title/Summary/Keyword: He-Ne 레이저

Search Result 156, Processing Time 0.019 seconds

Vibration Analysis Using Laser Speckle (레이저 스펙클을 이용한 진동분석)

  • Ruck, Do-Jin;Sung, Duk-Yong;Kang, Sung-Soo;Lee, Won-Jin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.2
    • /
    • pp.77-80
    • /
    • 2001
  • The purpose of this work is that by using speckle phenomena of low-level He-Ne laser, it analyzes the movement condition of surface elements on a substance vibrating. The lights from laser reflect against a copper plate and will be shown as speckles on a vibration board. If we vibrate these speckles by sound waves of a speaker installed on the back, the speckles change with various shapes. When a vibration board has a maximum vibration, the frequency becomes a dynamical resonance frequency and we can mark the changes of speckles at that time on a vibration board.

  • PDF

Effect and Prognosis of Combined Essential Oil Inhalation and He-Ne Laser Treatment of Nasal Diseases (비강질환에 대한 향기흡입과 He-Ne 레이저 병행 치료의 효과 및 예후)

  • Jeong, Sun-Hee;Lee, Seung-Yeon
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.17 no.2
    • /
    • pp.149-160
    • /
    • 2003
  • Objective : Essential oil inhalation and He-Ne laser treatment has become increasingly available in children with nasal diseases. But the reports on the effect and prognosis have been poor. In this study, we analyzed the treatment effect, recurrence rate and the degree of recurrent symptoms. Materials/Methods: 23 children(2-10 year-old) with nasal diseases, who received essential oil inhalation with He-Ne laser treatment at least 10 times in our hospital from January 1st 2001 to December 31th 2002 were studied. Result : Ten cases are male & thirteen cases are female. The average of age was 4.91 year-old. The most frequency symptoms are nasal discharge (82.6%), nasal obstruction (78.3%), cough (47.8%), secretion sound (39.1%), sneezing (17.4%). Average numbers of treatment period, interval and treatment times are 71.79 days, 4.06 days, 18.13 times respectively. Of the 23 children, 14 children were in 'all symptom improved' at the remedial ends, and 22 children relapsed. In the degree of recurrent symptoms, 15 children were in 'more improved then before-treatment and not equal to directly remedial ends'. No case was in 'worse than before-treatment'. The final result of treatment, 6 children keep the degree of remedial ends, on the other hand 17 children are not. Conclusions : Even though, the recurrence rate was high, this combined treatment improve nasal symptoms. The final assessment is good, when the treatment-result is good, when the treatment interval is regular and when parent's are cooperative. If the symptoms continue a whole year, the result is not so good.

  • PDF

Effects of Intravenous He-Ne Laser Irradi on Meridian-Heart·Circulation CMP and Hyperlipidemia (정맥혈관내(靜脈血管內) 헬륨-네온 레이저 조사(照射)가 메리디안 심(心)·순환(循環) 대표점(代表點)과 고지혈증(高脂血症)에 미치는 영향(影響))

  • Ahn, Soo-gi;Lee, Sam-ro;Hwang, Woo-jun
    • Journal of Sasang Constitutional Medicine
    • /
    • v.10 no.1
    • /
    • pp.269-284
    • /
    • 1998
  • The purpose of this study was to investigate the effect of ILIB(Intravenous Laser Irradiation of blood) on Meridian-Heart Circulation CMP and Hyperlipidemia. Circulatory symptom of 20 patients was treated with ILIB. After 10 times' treatment, changes of total cholesterol, HDL-cholesterol, triglyceride and Meridian-Heart Circulation CMP value were observed. The results were as follows : 1. In observation of Meridian-Heart Circulation CMP value, significant increase was observed in both pre-ID generation and post-ID generation. So, distinctive observation between pre-ID generation and post-ID generation became not relatively significant. 2. In observation of Meridian-Heart Circulation CMP value, significant increase was observed in both left and right. So, distinctive observation between left and right became not relatively significant. 3. In observation of Meridian-Heart CMP value, significant increase was not observed in control group, but significant increase close to normal value was observed in treatment group after treatment of Intravenous He-Ne Laser Irradiation. 4. In observation of Meridian-Circulation CMP value, significant increase was not observed in control group, but significant increase close to normal value was observed in treatment group after treatment of Intravenous He-Ne Laser Irradiation. 5. In concentration of plasma total cholesterol and plasma triglyceride, significant decrease was not observed in control group, but significant increase was observed in treatment group after treatment of Intravenous He-Ne laser Irradiation. 6. Significant concentration change of plasma HDL-cholesterol was not observed in both control group and treatment group. From above results, it was thought that Intravenous He-Ne Laser Irradiation was significant effect on heart circulatory system in human body.

  • PDF

레이저 간섭계를 이용한 미소각도형성기의 개발

  • 엄태봉;임재선;원종욱;정명세
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.9 no.3
    • /
    • pp.373-378
    • /
    • 1985
  • 본 연구에서는 He-Ne레이저를 광원으로 하는 시준기 교정용 레이저 각도 간섭 계를 설계 제작하였으며 이 장치의 계통적 오차(systematic error)를 분석하였다. 또 간섭계의 반사경으로 사용된 두 코너큐브(corner cube) 중심 사이의 간격측정을 위 한 새로운 방법을 연구하였으며 이 측정의 정확도를 실험적으로 검사하였다.

Interferometric Measurement of Flexure Error in a Ring Laser Gyroscope (간섭계를 이용한 링레이저 자이로스코프의 플렉셔 오차 측정)

  • 김정주;이동찬;이재철;조민식;권용율
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.07a
    • /
    • pp.272-273
    • /
    • 2003
  • 링레이저 자이로스코프(Ring Laser Gyroscope-이하 RLG)는 비행기, 유도무기, 선박, 지상무기 등의 관성항법장치(Inertial Navigation System)에 사용되는 각속도 센서로서 항체의 위치와 자세 정보를 제공하는 핵심 구성품 중의 하나이다. 각속도 검출 원리는 삼각형 또는 사각형의 공진기에 He과 Ne을 혼합한 이득매질을 사용하여 서로 반대방향으로 회전하는 두 개의 레이저 빔을 발생시켜서 Sagnac 효과에 의해 외부의 회전 입력을 받을 때 서로 다른 광 경로의 차이로 인한 두 빔의 간섭으로 회전각을 검출한다. (중략)

  • PDF

Offset Frequency Stabilization of He-Ne Lasers Using Phase Locked Loop (PLL을 이용한 헬륨-네온 레이저의 옵셋 주파수 안정화)

  • Yun Dong Hyun;Suh Ho Sung;Lyou Joon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.11 no.6
    • /
    • pp.496-501
    • /
    • 2005
  • This paper presents experimental results of the frequency offset locking of He-Ne lasers and the stability analysis. The master laser is free running, and the slave laser is a single-mode operating laser. The frequency difference of two lasers is stabilized to 200 MHz which can be synchronized using PLL servo. The measured beat frequency between two lasers was 200.004 MHz ${\pm}$ 0.15 MHz. The square root of Allan variance as a measure of stability in time domain is also measured. The long-term stability of the beat was worse than sort-term stability. With a gate time $\tau=1000\;s$, the square root of Allan variance was about 1 GHz. The results of the square root of Allan variance of the stabilized beat signal was a gate time of $\tau=1000\;s$, the square root of Allan variance was about 1.5 kHz. The long-term stability was improved by more than several hundred times compared with that without the stabilization.

The Development of High Speed Wavefront Sensor for Diagnosis of Beam Quality of He-Ne Laser (He-Ne 레이저 빔 품질 진단용 고속파면센서 개발)

  • Lee, Young-Cheol;Lee, Jae-Il;Kang, Eung-Cheol
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.10 no.4
    • /
    • pp.160-167
    • /
    • 2007
  • In this paper, we presented the development results of high speed wavefront sensor which is used in diagnosing the beam quality of He-Ne laser for adaptive optics system. The beam quality information of laser in AO system is necessarily required for diagnosing the optical components or correcting the distorted wavefront afterward. According to system requirements, normally, it is requested that there are high precision of measurement and real time processing speed. The developed wavefront sensor in this paper achieved maximum 30Hz of measurement rate and ${\lambda}/20(\;{@}\;{\lambda}=0.6328{\mu}m)$ of measurement precision in RMS. We also applied the developed into an experimental adaptive system and verified the performance of it by correcting the aberrated wavefront with a rate of 30Hz and $\lambda$/20 precision using the combination of the developed and PID control algorithm.

Ne-Ne 레이저의 간섭을 이용한 고정밀 리니어 스케일의 제작에 관한 연구

  • 전병욱;박두원;이명호;한응교
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1991.04a
    • /
    • pp.176-194
    • /
    • 1991
  • A study on the Manufactiring of High-Precision Linear Scale by the Use of He-Ne Laser Interference Of late, along with the advancement of procision machining technology, the reauirement of super-precision measurement increases as time goes on, and the precision and accuracy of standard scale which is a basis of procision measurement has been cognized as a oriterion of industrial development in a nation. Up to now, mechanical and chemical methods have been widely employed to carve scale lines on linear scale, and it is impossible for the linear scale manufactured by means of those methods to guarantee the measurement with sub-micron level owing to errors attended with various problems. And the measuring length also bears errors subjected to the influence of surroundings condition, and shows inefficient circumstances in measurement on the ground of the complexity of measuring procedure as well as massive measuring apparatus. Hence in this paper, we described on technology by which we can carve scale lines thru optical method under the condition of laboratory by using rhcoherence of He-Ne two-mode stabilized laser and in turn, put it to practical use as linear scale for the measurment of lengrh. In this researchin the case of setting scale interval to 20 .mu. m, we employed super-precision scale-carving device associated by Ar larser and acoustic optical modulator in lieu of flsahing lamp scale-carving device, and we consequently obtained superior linear scales carved with precision and accuracy of .+-. 0.3 .mu. m.

Manufacture of an Acousto-Optical Spectrometer for Radio Astronomical Observations (우주전파관측용 음향광학 전파분광기의 제작)

  • 임인성;최재현;오승엽
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.8 no.1
    • /
    • pp.1-12
    • /
    • 1997
  • The acousto-optical spectrometer as a new type backend of the receiver system for radio astronomical observations is manufactured for radio signal analysis. We studied on the effect of Acousto-Optic and Acousto-Optic devices and designed the optics system. We manufactured the optical mount and the CCD detector for deflected beam and interface card. This acousto-optical spectrometer consisted of a laser, optics, acousto-optic deflector, CCD detector and Interface card. This system use He-Ne laser as a light source and use optics to get parallel beam and to focus the deflected beam. Acousto-optic deflector converts IF signal to ultrasonic wave and deflect the laser beam according to the Bragg deflection. The ultra wide band acousto-optic deflector has 1 GHz bandwidth and a total of 2,048 channel Charge Coupled Device for signal detection. In this study, we discuss the theoretical description on the effect of Acousto-optics, the design of the optics, manufacture of optical mount, CCD detector, interface card and we presented the results of experiment. As a result of measurement, we have 1,000 channels bandwidth from CCD channels.

  • PDF