Measurement of Vibration of Rotating Disk Cam Using He-Ne Laser and Photodiode (광소자와 헬륨-네온 레이저를 이용한 디스크 캠의 진동 측정)

  • Yoo, W.J.;Lee, G.S.;Kim, J.D.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.12 no.10
    • /
    • pp.69-77
    • /
    • 1995
  • This laser measurement system has been developed using He-Ne laser and photodiode. The laser beam intensity transmitted on a photodiode was disturbed by eccentrically rotating disk cam with various speeds. The photodiode and an amplifier were used to change the detected beam intensity into voltage. The digitized data through the developed system were recorded on a micro-computer by using a signal analysis program. Its reliability was ascertained by using FFT analyzer. The vibration of rotating disk cam can be analyzed by measureing the intensity change of laser beam which the results by FFT analyzer were similar to. The amplifier was devised to be able to modulate the fluctuations of laser beam. The voltage could be linearly recorded with the change of the laser beam intensity.

  • PDF

Effects of He-Ne Laser Irradiation on the Activity of the Cultured Fibroblast (He-Ne 레이저 조사가 배양 섬유모세포의 활성에 미치는 영향)

  • Song In-Young;Lee Jae-Hyoung
    • The Journal of Korean Physical Therapy
    • /
    • v.9 no.1
    • /
    • pp.71-79
    • /
    • 1997
  • The purpose of this study were to determined the effect of laser irradiation on the fibroblast activity. Cultures of 3T3 fibroblasts were subjected to Helium Neon laser(632.8 nm) irradiation of various energy density. On one, two and three consecutive days the fibroblast monolayers wert irradiated for period from 0 to 32 minutes with 8 mW of average output power. The fibroblast activity was determined by the quantitative assay of MTT, SRB and NR after incubation of the fibroblasts for 24 hours. Results show that exposure duration from 2 min to 32 min could increase MTT at three consecutive days, whereas control and 1 min, one and two days irradiation had were not inclosed. The SRB and NR were inclosed at two and three consecutive days from 2 min to 32 min, whereas control and 1 min, and once radiation were not increased. These result demonstrate that energy density from 0.48 to 7.64 J/cm could increase cellular protein contents and fibroblast activity at more than twice irradiation of laser, whereas low energy density (less than 0.24 J/m) and once irradiation of laser had no effect. The results suggest that the beneficial effect of the He-Ne laser with adequate dose on fibroblast activity in vitro.

  • PDF

A Study on the Manufacturing of High Precision Linear Scale Using He-Ne Laser Interference (He-Ne 레이저의 간섭을 이용한 고정밀 리니어 스케일의 제작에 관한 연구)

  • Han, Eung-Gyo;Jeon, Byeong-Uk;Lee, Myeong-Ho;Park, Du-Won;No, Byeong-Ok;Sakurai, Yoshimasa
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.8 no.3
    • /
    • pp.82-92
    • /
    • 1991
  • A study on the manufacturing of High Precision Linear Scalr using He-Ne Laser interference Of late, along with the advancement of precision machining technology, the requirement of super precision measurement increases as time goes on, and the accuracy of standard scale which is a basis of precision measurement has been cognized as a criterion of industrial development in a nationl. In this paper, we described on technology by which we could carve scale lines thru optical method under the condition of laboratory by using the coherence of He-Ne two-mode stabilized laser and in turn, put it to practical use as linear scale for the measurement of length. Hence in this research in the case of setting scale interval to 20 ${\mu}m$, we employed super precision scale-carving device associated with Ar laser and acousto optic modulator in lieu of flashing lamp scale-carving device, and we obtained as experimental result superior linear scales carved within the accuracy of ${\pm}$0.3${\mu}m$.

  • PDF

Development of a RF Excited Ring Laser Gyroscope (RF 방전을 이용한 소형 링 레이저 자이로스코프의 개발)

  • 손승현;조현주;김완식;김의찬;전갑송;김회영;윤성진;이재철
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.07a
    • /
    • pp.270-271
    • /
    • 2003
  • 링 레이저 자이로스코프는 회전각을 검출하는 센서로서 광학식이 가지는 정밀함과 견고성으로 관성항법을 비롯한 운동 제어를 필요로 하는 여러 분야에서 기존의 기계식 자이로스코프를 대체해 오고 있다. 링 레이저 자이로는 세 개 또는 네 개의 반사경으로 밀폐된 고리형 공진기를 구성하고 He-Ne 기체를 봉입하여 방전시킴으로써 서로 반대 방향으로 진행하는 레이저를 동시에 발진시키면 Sagnac 효과에 의해 공진기의 회전각에 비례하여 두 레이저의 주파수 차이가 발생하는 원리를 이용한다. (중략)

  • PDF

Theoretical Analysis of Buffer Gas Effects of a Discharge Excited KrF Laser (방전여기 KrF 레이저의 완충가스 영향에 대한 이론 해석)

  • 최부연;이주희
    • Korean Journal of Optics and Photonics
    • /
    • v.1 no.1
    • /
    • pp.33-39
    • /
    • 1990
  • By developing a computer simulation code for discharge excited KrF excimer laser, we analyzed mainly the effects of buffer gas for the $KrF^*$ formation. the $KrF^*$ relaxation. and the absorption of the laser radiation. The $KrF^*$ formation efficiency were found to be 7.5%, 19% and the $KrF^*$ relaxation kinetic reactions were found to be 45%, 30% at the charging voltage of 30 KV and He. Ne buffer gas. respectively. But the absorption of the 248 nm laser radiation were less than 10% by the buffer gas.er gas.

  • PDF

Development of Retina Photographing and Multi Channel Image Acquisition System for Thickness Measurement of Retina (망막 두께 측정을 위한 망막 촬영 및 다채널 영상획득장치 개발)

  • 양근호
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.5 no.1
    • /
    • pp.13-17
    • /
    • 2004
  • In order to measure the retina thickness, the retina photographing system and the multi-channel high speed image data acquisition system is developed. This system requires the optical processing techniques and the high speed image processing techniques. The HeNe laser beam is projected the retina in artificial eye and then we sensed the reflected laser signal using APD array. The laser projection system on retina using optical instruments is implemented. In order to project the plane laser beam on retina, laser photographing system used the polygon mirror for horizontal scanning and the galvano mirror for vertical scanning. We acquired retina images in each channel of APD array, transferred computer using PCI interface the image data after real-time A/D converting.

  • PDF

The Studies of the low power Wavelengths of He-Ne IR laser on the changes of the serum biochemical components in burn rats (저 출력 레이저 파장에 따른 화상 쥐 혈청 생화학 성분 변화에 대한 연구)

  • Rho, Min-Hee;Kim, Eun-Young;Yong, Joon-Hwan
    • Journal of Korean Physical Therapy Science
    • /
    • v.9 no.1
    • /
    • pp.17-24
    • /
    • 2002
  • This studies were to investigate the effects of low power wavelengths Helium-Neon Infra-Red(He-Ne IR)laser on the changes of the blood biochemical components in burn rats. The thirty Spraque-Dewely adult male rats were assigned to the 5 groups; the experimental groups(3), the burn control group(1) and the control group(1). There was made three degree burn by the 250mW IR on the back of each rats, from 3 days after being, burned, the experimental laser groups were irradiated low power wavelengths (292Hz, 1168Hz, 4672Hz) He-Ne IR laser for 5 minutes every day during the 7days. The results wee as follows: The activities of aspirate aminotransferase(AST), alanine aminotransferase(ALT), and lactate dehydrogenase(LDH), on treated with the wavelengths ((292Hz, 1168Hz, 4672Hz) laser groups during 5 min. for 7 days were significantly increased to the control group respectively, but those of total cholesterol(CHOL) and alkaline phosphatase(ALP) were significantly decreased to the a control group (p<0.05). there were significantly decreased on the activity of alanine aminotransferase and alkaline phosphatase on the all experimental groups to the burn control group and those of lactate dehydronase on treated with 292Hz and 4672Hz wavelength9 groups to the burn control group but, were significantly increased on those of urea nitrogen (292Hz and 1168Hz)(p<0.05). The activity of AST, LDH, on treated with 1168Hz wavelengths were significantly decreased of the 292Hz and 4672Hz wavelengths groups that of ALT on the treated with 1168Hz group was significantly increased to the 4672 Hz wavelength group but those of CHOL and LDH on the 1168Hz and 4672Hz wavelength groups were dignificatly decreased to the MHz wavelengths group. As above results, the changes of the activities of biochemical conponents in the serum levels on the healing process have meaningful effected of the role of low power wavelengths He-Ne IR laser.

  • PDF

The Study on the Application of He-Ne Laser with Low Energy ILIB to the Superficial Venules (저용량(低容量) He-Ne 레이저침의 혈락적용(血絡適用) 연구(硏究))

  • Kim Sung-Chul;Cho Eun-Hee;Na Chang-Su
    • Korean Journal of Acupuncture
    • /
    • v.20 no.3
    • /
    • pp.35-47
    • /
    • 2003
  • Objective : The purpose of this study was to investigate the significance of the Oriental medical treatment using He-Ne laser with low energy intravascular Laser Irradiation of Blood(ILIB) through the superficial venules. Methods : The investigation of details connected with the superficial venules in the literature is performed. The investigation of details connected with the pricking blood techniques through the superficial venules in the literature is performed. The classification of the pricking blood techniques through the superficial venules by the blood-letting puncture methods in the literature is performed. The arrangement of domestic clinical treatises on the effectiveness of medical treatment using He-Ne laser with low energy ILIB through the superficial venules is performed. The consideration on the methodology for the improvement of the clinical effectiveness of He-Ne laser with low energy ILIB through superficial venules is performed. Results and Conclusions : The superficial venules are small arteries, veins and capillaries in the superficial region of the human body. In the pricking blood techniques, there are the blood-letting puncture using the implement of acupuncture to the Jing points, Extra points and superficial blood vessels and the acupuncture using the Hirudo. The methods of the blood-letting puncture are classified into the venous blood-letting puncture, the pricking , the picking out white fiber-like substances from the subcutaneous tissue, the cluster needling, the scattered needling, the blood-letting puncture of the tready collateral branch of the large channel and the blood-letting puncture of skin. The He-Ne laser with low energy ILIB through the superficial venules belongs to the Oriental medical treatment as the method of the blood-letting puncture in the vein of cubital fossa. The He-Ne laser with low energy ILIB has an effect on hyperfibrinogenemia, hyperlipidemia, speech and motor dysfunction in the case of cerebral infarction, headache, dizziness, pain and numbness. It is considered that fundamental research on the biological change of the human body, the experimental animal and the unicellular animal, and research on the effectiveness and the safety, and the development of He-Ne laser with low energy ILIB of an effective wavelength range are necessary.

  • PDF

A Light Source for Heterodyne Interferomtry using Beat Frequency between Two-axial Modes of a He-Ne Laser (2-종모드 레이저의 비트 주파수를 이용한 헤테로다인 간섭계용 광원 개발)

  • 김민석;김승우
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2001.02a
    • /
    • pp.92-93
    • /
    • 2001
  • 주파수 안정화 레이저 광원은 10-6 이상의 상대 불확도가 필요한 간섭계에서 널리 쓰이고 있으며 특히 변위 측정 시스템에서는 반드시 쓰이고 있다. 상용화된 많은 변위 측정 시스템은 신호 대 잡음비가 우수하고 광학계의 정렬이 더 쉬운 헤테로다인 방식을 채택하고 있으며 이를 위해서 서로 수직 선형 편광인 다른 주파수의 광을 내보내는 광원이 필요하다. 현재 헤테로다인 변위 측정 시스템에 쓰이고 있는 광원은 이중 주파수 광원을 만드는 방식에 따라 지만 효과(Zeeman effect)를 이용한 지만 레이저(HP사)와 음향-광 변조기(Acousto-optic modulator)를 이용한 이중 주파수 레이저(Zy해사)가 있다. (중략)

  • PDF