• 제목/요약/키워드: He gas

검색결과 559건 처리시간 0.031초

다중침전극형 플라즈마 반응기를 이용한 수소발생 특성 (The Hydrogen Generation's Characteristics using Plasma Reactor of Multi-needle Electrode Type)

  • 박재윤;김종석;정장근;고희석;박상현;이현우
    • 한국전기전자재료학회논문지
    • /
    • 제17권11호
    • /
    • pp.1246-1251
    • /
    • 2004
  • This paper is investigated about the effect of carrier gas type and the humidity for generating hydrogen gas. The vibration of the water surface is more powerful with increasing applied voltage. In this experimental reactor which is made of multi-needle and plate, the maximum acquired hydrogen production rate is about 3500 ppm. In the experimental result of generating hydrogen gas by non-thermal plasma reactor, the rate of generating hydrogen gas is different with what kind of carrier gas is. We used two types of carrier gas, such as $N_2$ and He. $N_2$ as carrier gas is more efficient to generate hydrogen gas than He because $N_2$ is reacted with $O_2$, which is made from water dissociation. In comparison with water droplet by humidifier and without water droplet by humidifier, the generation of hydrogen gas is decreased in case of water droplet by humidifier. That is the result that the energy for water dissociation is reduced on water surface because a part of plasma energy is absorbed at the small water molecular produced from humidifier.

The bactericidal effect of an atmospheric-pressure plasma jet on Porphyromonas gingivalis biofilms on sandblasted and acid-etched titanium discs

  • Lee, Ji-Yoon;Kim, Kyoung-Hwa;Park, Shin-Young;Yoon, Sung-Young;Kim, Gon-Ho;Lee, Yong-Moo;Rhyu, In-Chul;Seol, Yang-Jo
    • Journal of Periodontal and Implant Science
    • /
    • 제49권5호
    • /
    • pp.319-329
    • /
    • 2019
  • Purpose: Direct application of atmospheric-pressure plasma jets (APPJs) has been established as an effective method of microbial decontamination. This study aimed to investigate the bactericidal effect of direct application of an APPJ using helium gas (He-APPJ) on Porphyromonas gingivalis biofilms on sandblasted and acid-etched (SLA) titanium discs. Methods: On the SLA discs covered by P. gingivalis biofilms, an APPJ with helium (He) as a discharge gas was applied at 3 different time intervals (0, 3, and 5 minutes). To evaluate the effect of the plasma itself, the He gas-only group was used as the control group. The bactericidal effect of the He-APPJ was determined by the number of colony-forming units. Bacterial viability was observed by confocal laser scanning microscopy (CLSM), and bacterial morphology was examined by scanning electron microscopy (SEM). Results: As the plasma treatment time increased, the amount of P. gingivalis decreased, and the difference was statistically significant. In the SEM images, compared to the control group, the bacterial biofilm structure on SLA discs treated by the He-APPJ for more than 3 minutes was destroyed. In addition, the CLSM images showed consistent results. Even in sites distant from the area of direct He-APPJ exposure, decontamination effects were observed in both SEM and CLSM images. Conclusions: He-APPJ application was effective in removing P. gingivalis biofilm on SLA titanium discs in an in vitro experiment.

Zircaloy-4의 플라즈마 아크용접에서 용접변수가 비이드형상에 미치는 영향 (A Study on Effects of Parameters on Beads by Plasma Arc Welding for Zircaloy-4)

  • 고진현;김수성;이영호
    • Journal of Welding and Joining
    • /
    • 제15권6호
    • /
    • pp.57-65
    • /
    • 1997
  • A study was undertaken to determine the influence of welding variables such as shielding and plasma gases, torch standoff, travel speed and heat input, etc. on the quality of plasma arc welds in Zircaloy-4 sheet, 2mm thick. Effect of shielding gases and their flow rates on the mechanical properties of Zircaloy-4 welds by plasma arc welding were determined in terms of tensile, bardness and bend tests. The microstructure and fracture surface of Zircaloy-4 welds were investigated by optical and scanning electron microscopies. In addition, the causes of porosity and undercut in plasma arc welds of Zircaloy-4 were also investigated. Zircaloy-4 weld bead width and depth by helium shielding gas showed a wider and deeper than those by argon. It was found that Zircaloy-4 welds with shielding gas of helium did dxhibit a little smoother and uniform weld beads than those with shielding gas of argon. It was also found that the optimum gas flow rates for Zircaloy-4 welding were 0.45l/min for plasma gas with Ar and 4.5 - 6 l/min for shielding gas with He. In addition, there was no big difference in the microstructure and fracture surface of the weld metals made by either Ar shielding gas or He shielding gas.

  • PDF

Investigation of Ne and He Buffer Gases Cooled Ar+ Ion Clouds in a Paul Ion Trap

  • Kiai, S.M. Sadat;Elahi, M.;Adlparvar, S.;Nemati, N.;Shafaei, S.R.;Karimi, Leila
    • Mass Spectrometry Letters
    • /
    • 제6권4호
    • /
    • pp.112-115
    • /
    • 2015
  • In this article, we examine the influences of Ne and He buffer gases under confined Ar+ ion cloud in a homemade Paul ion trap in various pressures and confinement times. The trap is of small size (r0 = 1 cm) operating in a radio frequency (rf) voltage only mode, and has limited accuracy of 13 V. The electron impact and ionization process take place inside the trap and a Faraday cup has been used for the detection. Although the experimental results show that the Ar+ ion FWHM with Ne buffer gas is wider than the He buffer gas at the same pressure (1×10-1 mbar) and confinement time is about 1000 μs, nevertheless, a faster cooling was found with He buffer gas with 500 μs. ultimetly, the obtanied results performed an average cloud tempertures reduced from 1777 K to 448.3 K for Ne (1000 μs) and from 1787.9 K to 469.4 K for He (500 μs)

AC plasma display panel의 페닝 방전가스 혼합비 변화에 따른 방전특성 연구 (A Study on the Discharge Characteristics with New Penning Gas Mixture for AC plasma display panel)

  • 박문필;이승준;이재경;황호정
    • 한국진공학회지
    • /
    • 제11권2호
    • /
    • pp.127-134
    • /
    • 2002
  • 본 논문은 AC PDP에서 사용하는 가스의 혼합비, 압력, 페닝 효과를 고려한 가스 조합의 최적화를 통해 낮은 방전전압으로 휘도의 증가를 얻을 수 있는 고휘도, 고효율 PDP 페닝 기체 혼합비를 찾고자 하였다. He(70%)-Ne(27%)-Xe(3%)의 3원 혼합기체와 Ne(96%)Xe(4%)의 2원 혼합기체에 페닝 효과를 극대화하기 위한 소량의 Ar, Kr을 첨가하여 각각의 첨가비에 따른 방전 개시전압, 방전 유지전압, 휘도, 발광효율 등을 측정하였다. 또한 페닝효과에 의한 방전 공간상의 전자수 증가를 확인하기 위해 셀 내의 전극 위에 쌓이는 벽전하 양을 측정하였다. 소량의 Ar(0.01%-0.03%) 또는 Kr(0.01%-0.03%)을 HE-Ne-Xe과 Ne-Xe 혼합가스에 첨가했을 때 페닝효과에 기인하여 휘도 및 발광효율이 각각 최고 10%-20% 증가하였다. 또한 페닝효과를 확인하기 위한 벽전하의 양은 10%-25% 증가를 보였다. 방전개시전압 및 최소방전유지전압은 대략 2V-3V정도 감소하였다.

Analysis of Electron Transport Coefficients in Binary Mixtures of TEOS Gas with Kr, Xe, He and Ne Gases for Using in Plasma Assisted Thin-film Deposition

  • Tuan, Do Anh
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권2호
    • /
    • pp.455-462
    • /
    • 2016
  • The electron transport coefficients in not only pure atoms and molecules but also in the binary gas mixtures are necessary, especially on understanding quantitatively plasma phenomena and ionized gases. Electron transport coefficients (electron drift velocity, density-normalized longitudinal diffusion coefficient, and density-normalized effective ionization coefficient) in binary mixtures of TEOS gas with buffer gases such as Kr, Xe, He, and Ne gases, therefore, was analyzed and calculated by a two-term approximation of the Boltzmann equation in the E/N range (ratio of the electric field E to the neutral number density N) of 0.1 - 1000 Td (1 Td = 10−17 V.cm2). These binary gas mixtures can be considered to use as the silicon sources in many industrial applications depending on mixture ratio and particular application of gas, especially on plasma assisted thin-film deposition.

화학기상응축공정(Chemical Vapor Condensation)으로 제조된 Co 나노분말의 미세구조 및 자기적 성질에 미치는 운송기체의 영향 (Effect of Carrier Gas on the Microstructure and Magnetic Properties of Co Nanoparticles Synthesized by Chemical Vapor Condensation)

  • 최철진;;유지훈;김진천;김병기
    • 한국분말재료학회지
    • /
    • 제11권1호
    • /
    • pp.16-21
    • /
    • 2004
  • The nano-sized Co particles were successfully synthesized by chemical vapor condensation (CVC) process using the precursor of cobalt carbonyl ($Co_2(CO)_8$). The influence of carrier gases on the microstructure and magnetic properties of nanoparticles was investigated by means of XRD, TEM, XPS and VSM. The Co nano-particles with different phases and shapes were synthesized with a change of carrier gas : long string morphologies with coexistence of fcc and hcp structure in Ar carrier gas condition; finer Co core in a mass of cobalt oxide with only fcc structure in He; rod type cobalt oxide phase in Ar+6vol%$O_2$. The saturation magnetization and coercivity was lower in Co nanoparticles synthesized in He carrier gas, due to their finer size.

방전여기 KrF 레이저의 완충가스 영향에 대한 이론 해석 (Theoretical Analysis of Buffer Gas Effects of a Discharge Excited KrF Laser)

  • 최부연;이주희
    • 한국광학회지
    • /
    • 제1권1호
    • /
    • pp.33-39
    • /
    • 1990
  • 방전여기 방식의 KrF 엑사이머 레이저의 컴퓨터 시뮬레이션 프로그램을 개발하여 방전 중의 $KrF^*$ 형성, 탈여기 및 흡수반응 등에 대한 완충가스의 영향에 관해 해석하였다. He 가스와 Ne 가스의 경우 $KrF^*$ 생성효율은 각각 7.5%, 19%였으며, $KrF^*$ 탈여기는 충전전압 30kV에서 각각 45, 30%의 비율을 차지하였다. 그러나 흡수과정에서는 완충가스의 영향이 10% 이하였다.

  • PDF

The effect of Gas Mixture Ratio on Discharge Characteristics of an AC PDP Cell

  • Lee, Hae-June;Lee, D.K.;Choi, J.H.;Cho, Y.S.;Park, H.D.;Lee, H.J.;Park, C.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2005년도 International Meeting on Information Displayvol.I
    • /
    • pp.171-174
    • /
    • 2005
  • Experimental measurements are reported and compared with the results of a two-dimensional fluid simulation for the investigation of the discharge characteristics regarding the change of the mixture ratio of Ne-Xe-He noble gases. The increase of Xe contents results in the increases of luminance and luminous efficiency while it also results in the increase of the breakdown voltage and the discharge time lag. The addition of He gas increases the brightness and the luminance efficiency. When Xe partial pressure is low, the luminance efficiency increases with the amount of He at the same total pressure. When Xe partial pressure is high, however, the luminance efficiency has a maximum value when the partial pressure of He is about 10% of the total pressure for a standard AC PDP cell with Xe fraction of $10{\sim}30%$.

  • PDF

Safety evaluation of atmospheric pressure plasma jets in in vitro and in vivo experiments

  • Lee, Ji-Yoon;Park, Shin-Young;Kim, Kyoung-Hwa;Yoon, Sung-Young;Kim, Gon-Ho;Lee, Yong-Moo;Seol, Yang-Jo
    • Journal of Periodontal and Implant Science
    • /
    • 제51권3호
    • /
    • pp.213-223
    • /
    • 2021
  • Purpose: The atmospheric pressure plasma jet (APPJ) has been introduced as an effective disinfection method for titanium surfaces due to their massive radical generation at low temperatures. Helium (He) has been widely applied as a discharge gas in APPJ due to its bactericidal effects and was proven to be effective in our previous study. This study aimed to evaluate the safety and effects of He-APPJ application at both the cell and tissue levels. Methods: Cellular-level responses were examined using human gingival fibroblasts and osteoblasts (MC3T3-E1 cells). He-APPJ was administered to the cells in the experimental group, while the control group received only He-gas treatment. Immediate cell responses and recovery after He-APPJ treatment were examined in both cell groups. The effect of He-APPJ on osteogenic differentiation was evaluated via an alkaline phosphatase activity assay. In vivo, He-APPJ treatment was administered to rat calvarial bone and the adjacent periosteum, and samples were harvested for histological examination. Results: He-APPJ treatment for 5 minutes induced irreversible effects in both human gingival fibroblasts and osteoblasts in vitro. Immediate cell detachment of human gingival fibroblasts and osteoblasts was shown regardless of treatment time. However, the detached areas in the groups treated for 1 or 3 minutes were completely repopulated within 7 days. Alkaline phosphatase activity was not influenced by 1 or 3 minutes of plasma treatment, but was significantly lower in the 5 minute-treated group (P=0.002). In vivo, He-APPJ treatment was administered to rat calvaria and periosteum for 1 or 3 minutes. No pathogenic changes occurred at 7 days after He-APPJ treatment in the He-APPJ-treated group compared to the control group (He gas only). Conclusions: Direct He-APPJ treatment for up to 3 minutes showed no harmful effects at either the cell or tissue level.