• Title/Summary/Keyword: He gas

Search Result 559, Processing Time 0.028 seconds

Rectal Temperature Maintenance Using a Heat Exchanger of Cardioplegic System in Cardiopulmonary Bypass Model for Rats (쥐 심폐바이패스 모델에서 심정지액 주입용 열교환기를 이용한 직장체온 유지)

  • Choi Se-Hoon;Kim Hwa-Ryong;Paik In-Hyuck;Moon Hyun-Jong;Kim Won-Gon
    • Journal of Chest Surgery
    • /
    • v.39 no.7 s.264
    • /
    • pp.505-510
    • /
    • 2006
  • Background: Small animal cardiopulmonary bypass (CPB) model would be a valuable tool for investigating path-ophysiological and therapeutic strategies on bypass. The main advantages of a small animal model include the reduced cost and time, and the fact that it does not require a full scale operating environment. However the rat CPB models have a number of technical limitations. Effective maintenance and control of core temperature by a heat exchanger is among them. The purpose of this study is to confirm the effect of rectal temperature maintenance using a heat exchanger of cardioplegia system in cardiopulmonary bypass model for rats. Material and Method: The miniature circuit consisted of a reservoir, heat exchanger, membrane oxygenator, roller pump, and static priming volume was 40 cc, Ten male Sprague-Dawley rats (mean weight 530 gram) were divided into two groups, and heat exchanger (HE) group was subjected to CPB with HE from a cardioplegia system, and control group was subjected to CPB with warm water circulating around the reservoir. Partial CPB was conducted at a flow rate of 40 mg/kg/min for 20 min after venous cannulation (via the internal juglar vein) and arterial cannulation (via the femoral artery). Rectal temperature were measured after anesthetic induction, a ter cannulation, 5, 10, 15, 20 min after CPB. Arterial blood gas with hematocrit was also analysed, 5 and 15 min after CPB. Result: Rectal temperature change differed between the two groups (p<0.01). The temperatures of HE group were well maintained during CPB, whereas control group was under progressive hypothermia, Rectal temperature 20 min after CPB was $36.16{\pm}0.32^{\circ}C$ in the HE group and $34.22{\pm}0.36^{\circ}C$ in the control group. Conclusion: We confirmed the effect of rectal temperature maintenance using a heat exchanger of cardioplegia system in cardiopulmonary bypass model for rats. This model would be a valuable tool for further use in hypothermic CPB experiment in rats.

A Case of Idiopathic Interstitial Pneumonia in Childhood (소아 특발성 간질성 폐렴 1례)

  • Lee, Su-Jin;Shin, Eon-Woo;Park, Eun-Young;Oh, Phil-Soo;Lee, Kon-Hee;Kim, Kwang-Nam;Shin, Ho-Seung;Lee, Il-Seung
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.3
    • /
    • pp.327-332
    • /
    • 2005
  • Interstitial lung disease refers to a group of pulmonary disorders characterized by inflammation of the interstitium, derangements and loss of alveolar capillary units leading to disruption of alveolar gas exchange, which induces symptoms of restrictive lung disease. Cases of interstitial pneumonia in children are uncommon and mostly have unknown causes. We have experienced an 8-year old boy who had symptoms of cyanosis, dry cough, dyspnea and abrupt weight loss. He had not been exposed to organic dusts, allergens or any other systemic disease infections. Chest radiology showed diffuse ground glass opacity in both lung fields. High resolution computed tomography(HRCT) showed multiple small patchy areas of consolidation with an underlying ground glass appearance in both lungs. The pathologic findings of lung biopsy tissue showed patchy areas of interstitial fibrosis, alveolar obliteration and nodular fibrotic areas, strongly suggesting interstitial pneumonia. No specific finding of viral inclusion or any other evidence of infection was found under electromicroscopy. We used peak flow meters to compare functional improvement. Forced expiratory volume in one second ($FEV_1$) was decreased to 25 percent of predicted value. The boy was given treatment with prednisone and showed improvements in HRCT findings after two months. He was able to tolerate easy exercise in school and showed clinical improvements after one year of follow up.

Nanophase Catalyst Layer for Direct Methanol Fuel Cells

  • Chang Hyuk;Kim Jirae
    • Journal of the Korean Electrochemical Society
    • /
    • v.4 no.4
    • /
    • pp.172-175
    • /
    • 2001
  • Nanophase catalyst layer for direct methanol fuel cell has been fabricated by magnetron sputtering method. Catalyst metal targets and carbon were sputtered simultaneously on the Nafion membrane surface at abnormally higher gas (Ar/He mixture) pressure than that of normal thin film processing. They could be coated as a novel structure of catalyst layer containing porous PtRu or Pt and carbon particles both in nanometer range. Membrane electrode assembly made with this layer led to a reduction of the catalyst loading. At the catalyst loading of 1.5mg $PtRu/cm^2$ for anode and 1mg $Pt/cm^2$ for cathode, it could provide $45 mW/cm^2$ in the operation at 2 M methanol, 1 Bar Air at 80"C. It is more than $30\%$ increase of the power density performance at the same level of catalyst loading by conventional method. This was realized due to the ultra fine particle sizes and a large fraction of the atoms lie on the grain boundaries of nanophase catalyst layer and they played an important role of fast catalyst reaction kinetics and more efficient fuel path. Commercialization of direct methanol fuel cell for portable electronic devices is anticipated by the further development of such design.

A Study on the Permeation Properties of Permanent Gases and condensable Vapors through Hexamethyldisiloxane Plasma-Polymerized Membranes (Hexamethyldisiloxane 플라즈마 중합막을 통한 영구기체 및 응축성 증기의 투과특성에 관한 연구)

  • Oh, Sae-Joong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.3
    • /
    • pp.699-706
    • /
    • 2018
  • The permeation properties of plasma polymer membranes were studied for permanent gases such as He, $H_2$, $O_2$, $N_2$, $CH_4$ and condensable vapors such as $CO_2$, $C_2H_4$, $C_3H_8$. The plasma polymers were prepared by the discharge of microwave or radiofrequency(RF) wave. Hexamethyldisiloxane (HMDS) vapor was used as a monomer for plasma polymerization. In HMDS plasma-polymerized membranes prepared under microwave discharge, the permeability coefficient was dependent of the kinetic molecular diameter of the permeate gases. Additionally the membranes showed higher $O_2/N_2$ permselectivity compared to the plasma polymers from radiofrequency discharge. On the contrary, in the HMDS plasma-polymerized membranes prepared under radiofrequency discharge, the permeability coefficient was dependent of the critical temperature of the permeant gases. The membranes showed high selectivities of $C_2H_4$ and $C_3H_8$ over $N_2$. The permeability coefficient of plasma polymerized membranes prepared under microwave discharge was dependent of the molecular diameter of permeant gases because of high crosslinking density of the membrane. However, the crosslinking density of the plasma polymerized membranes prepared under RF discharge was lower because the energy density of RF wave is weaker than that of microwave. Hence, the permeability of RF plasma polymerized membranes became dependent of the critical temperature rather than molecular diameter of the gases.

Solvent-free determination of BTEX in water using repetitive membrane extraction followed by GC-MS (반복적인 막 추출과 GC-MS를 이용한 물 중 BTEX의 분석)

  • Kim, He-Kap;Kim, Se-Young;Lee, Soo-Hyung
    • Analytical Science and Technology
    • /
    • v.24 no.5
    • /
    • pp.352-359
    • /
    • 2011
  • An analytical method for solvent-free determination of benzene, toluene, ethylbenzene, and xylenes (BTEX) in water using repetitive membrane extractions coupled to cryofocusing and GC-MS was derived. BTEX compounds that permeated through a nonporous silicone membrane from the aqueous phase and evaporated into the acceptor phase were purged into a cryofocusing trap ($-100^{\circ}C$) with helium gas. The BTEX compounds, thus enriched in the trap, were thermally desorbed into a capillary column GC and detected using an MS. The flow rate of the donor phase (30 mL water) was set at 10 mL/min, and membrane extractions, accomplished by returning the water drained from the extraction module to the sample container, were repeated three times at $20{\pm}2^{\circ}C$. Although recoveries (%) were variable, from the highest for benzene (approximately 80%) to the lowest for ethylbenzene and xylenes (3.5-10%), the method showed satisfactory precision (RSD 2.2-10%) with good-linearity calibration curves ($r^2$ 0.9976-0.9997 in 1-100 ${\mu}g$/L range) for all of the compounds. The method detection limits (MDLs) ranged from 0.16 to 1.8 ${\mu}g$/L. The results showed the method's advantages such as short analysis time and overall simplicity without solvent compared to the conventional techniques.

Transport Properties of Fluorinated Polyimide/PMMA-g-Silica Nanocomposite Membrane (PMMA가 그래프트된 실리카 나노입자를 포함한 불소계 폴리이미드 복합 분리막의 기체 투과 특성)

  • Kwon, Yu-Mi;Im, Hyun-Gu;Kim, Joo-Heon
    • Polymer(Korea)
    • /
    • v.34 no.1
    • /
    • pp.1-7
    • /
    • 2010
  • To enhance the transport properties of gas separation membrane, we prepared 6FDA-6FpDA based polyimide membrane with PMMA-graft-silica nanoparticles. The silica was grafted PMMA which is miscible with 6FDA-based polyimide after surface treatment by 3-methacryloxypropyltrimethoxysilane ($\gamma$-MPS). The untreated silica/6FDA-6FpDA membrane showed greater permeability and less selectivity than PMMA-g-silica/6FDA-6FpDA due to its low dispersion. The transport properties of PMMA-g-silica/6FDA-GFpDA membrane were measured as a function of filler concentration. These membranes were evaluated using pure gases (He, $O_2$, $N_2$, $CO_2$). The increase in permeation was attributed to changes in the free volume distribution until 1 wt%. After 1 wt%, the permeability was decreased by excess silica which decreased effective area in polymer matrix. The selectivity was decreased with increasing permeability on the whole. However, the selectivity of $CO_2$ showed more enhance value.

Design and Fabrication of the Cryogenically Cooled LNA Module for Radio Telescope Receiver Front-End (전파 망원경 수신기 전단부용 극저온 22 GHz 대역 저잡음 증폭기 모듈 설계 및 제작)

  • Oh Hyun-Seok;Lee Kyung-Im;Yang Seong-Sik;Yeom Kyung-Whan;Je Do-Heung;Han Seog-Tae
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.3 s.106
    • /
    • pp.239-248
    • /
    • 2006
  • In this paper, the cryogenically cooled low noise amplifier module for radio telescope receiver front-end using pHE-MT MMIC is designed and fabricated. In the selection of MMIC, the MMIC fabricated with the pHEMTS providing successful cryogenic operation are chosen. They are mounted in the housing using the thin film substrate. In the design of the housing, the absorber and the elimination of the gap between the carrier and the housing as well removed the unnecessary oscillations by its structure. The mismatch is improved by ribbon-tuning to provide the best performance at room temperature. The fabricated module shows the gain of $35dB{\pm}1dB$ and the noise figure of $2.37{\sim}2.57dB$ at room temperature over $21.5{\sim}23.5GHz$. In the cryogenic temperature of $15^{\circ}K$ cooled by He gas, the measured gain was above 35 dB and flatness ${\pm}2dB$ and the noise temperatures of $28{\sim}37^{\circ}K$.

Development for the Waste Plastics Process (폐플라스틱의 재활용 기술)

  • 여종기
    • Resources Recycling
    • /
    • v.6 no.2
    • /
    • pp.22-28
    • /
    • 1997
  • In recent yean thc problem of wastc plastics arc greatly incrcascd with ihe result uf lndushial growth. As a rcsult the amount of wastc plaslics in domestic area is appraxhnately 2,300,000 t<~nin 1996 base and contmuously increasing more than 12% cvcry ycar. Thc disposal way of these waste plastics arc dlLl malnly rely~ng on landill1 or partially incinuralion So that it hss become a senous social problem due to the second envirnmentd pollution. The tcchnologics iar prducing oil from the waste plastics have hccn dcvelopcd far along pennd and currently some of them are in a commercialiration stage Pyrolysis process in one of the major process m heating waslc plaslics bul still has some restlichons for the cammcrc~dizatian duc lo 11s emnom~cal problems assaciated with a systcmiltlc lecd collcctionidispnsJ ways. Cansldenng cnvaomcnld problems, thc inclease m the charge for waste matcds trcatmcnt and thc lmlitarion ni disposal area, it is inteicstcd that the wastc plastics treabncnt by pyrolysn. which would be the safest and the most eilic~ent process for cnnvcrting fecd wastc to rc-usablc rcsourccs. would he predomhant m ihe near h~lurc Thc shldy aims inr the development of haslc ted~nolagy for scaling up to a com~nercial sire through pyrolys~s process which is cnnduclcd under the absence of air. Furthern~orc the waste plastics can be recycled as iual gas or oil wilhout harmful effects in enviroment, The waste w e d plastics arc pyrolyzed in (he fluidized bcd rcaclor under continuous way and thc ail ylcld gives approx~marcly 47 4%.

  • PDF

Estimation of the Spring and Summer Net Community Production in the Ulleung Basin using Machine Learning Methods (기계학습법을 이용한 동해 울릉분지의 봄과 여름 순군집생산 추정)

  • DOSHIK HAHM;INHEE LEE;MINKI CHOO
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.29 no.1
    • /
    • pp.1-13
    • /
    • 2024
  • The southwestern part of the East Sea is known to have a high primary productivity compared to those in the northern and eastern parts, which is attributed to nutrients supplies either by Tsushima Warm Current or by coastal upwelling. However, research on the biological pump in this area is limited. We developed machine learning models to estimate net community production (NCP), a measure of biological pump, with high spatial and time scales of 4 km and 8 days, respectively. The models were fed with the input parameters of sea surface temperature, chlorophyll-a, mixed layer depths, and photosynthetically active radiation and trained with observed NCP derived from high resolution measurements of surface O2/Ar. The root mean square error between the predicted values by the best performing machine model and the observed NCP was 6 mmol O2 m-2 d-1, corresponding to 15% of the average of observed NCP. The NCP in the central part of the Ulleung Basin was highest in March at 49 mmol O2 m-2 d-1 and lowest in June and July at 18 mmol O2 m-2 d-1. These seasonal variations were similar to the vertical nitrate flux based on the 3He gas exchange rate and to the particulate organic carbon flux estimated by the 234Th disequilibrium method. To expand this method, which produces NCP estimate for spring and summer, to autumn and winter, it is necessary to devise a way to correct bias in NCP by the entrainment of subsurface waters during the seasons.

The progress in NF3 destruction efficiencies of electrically heated scrubbers (전기가열방식 스크러버의 NF3 제거 효율)

  • Moon, Dong Min;Lee, Jin Bok;Lee, Jee-Yon;Kim, Dong Hyun;Lee, Suk Hyun;Lee, Myung Gyu;Kim, Jin Seog
    • Analytical Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.535-543
    • /
    • 2006
  • Being used widely in semiconductor and display manufacturing, $NF_3$ is internationally considered as one of the regulated compounds in emission. Numerous companies have been continuously trying to reduce the emissions of $NF_3$ to comply with the global environmental regulation. This work is made to report the destruction and removal efficiency (DRE) of electrically heated scrubbers and the use rate in process chambers installed in three main LCD manufacturing companies in Korea. As the measurement techniques for $NF_3$ emission, mass flow controlled helium gas was continuously supplied into the equipment by which scrubber efficiency is being measured. The partial pressures of $NF_3$ and helium were accurately measured for each sample using a mass spectrometer, as it is emitted from inlet and outlet of the scrubber system. The results show that the DRE value for electrically heated scrubbers installed before 2004 is less than 52 %, while that for the new scrubbers modified based on measurement by scrubber manufacturer has been sigificentely improved upto more than 95 %. In additon, we have confirmed the efficiency depends on such variables as the inlet gas flow rate, water content, heater temperature, and preventative management period. The use rates of $NF_3$ in process chambers were also affected by the process type. The use rate of radio frequency source chambers, built in the $1^{st}$ and $2^{nd}$ generation process lines, was determined to be less than 75 %. In addition, that of remote plasma source chambers for the $3^{rd}$ generation was measured to be aboove 95 %. Therefore, the combined application of improved scrubber and the RPSC process chamber to the semiconductor and display process can reduce $NF_3$ emmision by 99.95 %. It is optimistic that the mission for the reduction of greenhouse gas emission can be realized in these LCD manufacturing companies in Korea.