• 제목/요약/키워드: Hazards of Electromagnetic Radiation to Ordnance(HERO)

검색결과 2건 처리시간 0.017초

HERO 시험평가 기법 연구 (The Research of the HERO Test and Evaluation Technique)

  • 신승제
    • 한국군사과학기술학회지
    • /
    • 제10권2호
    • /
    • pp.76-83
    • /
    • 2007
  • This report presents the test technique using optic thermal sensor for the HERO evaluation of equipment installed EED. The calibration method of EED-thermal sensor assembly is explained by relation between the current in bridge wire and voltage in thermal sensor. And the HERO test and evaluation method is indicated based on MIL-STD-464A and MIL-STD-331C. The safety and reliability levels of EED-thermal sensor assembly are evaluated when exposed in the electromagnetic environment.

ELINT 포드를 장착한 전투기의 전자기 환경 영향(E3) 시험평가에 관한 연구 (A Study on Electromagnetic Environmental Effects(E3) Test and Evaluation of Fighter Equipped with ELINT Pod)

  • 김인선;박영주;최대규;김장표;이병남
    • 한국군사과학기술학회지
    • /
    • 제15권3호
    • /
    • pp.288-297
    • /
    • 2012
  • This paper describes the verification test on Electromagnetic Environmental Effects(E3), which conducted on ground as a final step to confirm the normal operation of ELINT pod and Safety-of-Flight of KF-16C/D mounted with ELINT pod prior to the initial flight. Based on MIL-STD-464A, indispensable 7 requirements among 14 detailed requirements total were carried out in the test. Considering the Safety-of-Flight(SOF), we invest a great deal of time and effort on Hazards of Electromagnetic Radiation to Ordnance(HERO) and Intra-system EMC test. E3 test and evaluation were performed on 62 equipments of KF-16C/D, respectively. As a result, we verify that KF-16C/D mounted with ELINT pod(hereafter "system") are electromagnetically compatible among all subsystems and equipment within the system and with environments caused by electromagnetic effects external to the system.