Abstract
This paper describes the verification test on Electromagnetic Environmental Effects(E3), which conducted on ground as a final step to confirm the normal operation of ELINT pod and Safety-of-Flight of KF-16C/D mounted with ELINT pod prior to the initial flight. Based on MIL-STD-464A, indispensable 7 requirements among 14 detailed requirements total were carried out in the test. Considering the Safety-of-Flight(SOF), we invest a great deal of time and effort on Hazards of Electromagnetic Radiation to Ordnance(HERO) and Intra-system EMC test. E3 test and evaluation were performed on 62 equipments of KF-16C/D, respectively. As a result, we verify that KF-16C/D mounted with ELINT pod(hereafter "system") are electromagnetically compatible among all subsystems and equipment within the system and with environments caused by electromagnetic effects external to the system.