• Title/Summary/Keyword: Hazardous materials

Search Result 601, Processing Time 0.026 seconds

A Study on the Appropriate Management of Specific Hazardous Industrial Waste (특정유해산업폐기물의 적정관리에 관한 연구)

  • 양재윤;김원만;박재주
    • Environmental Analysis Health and Toxicology
    • /
    • v.6 no.1_2
    • /
    • pp.83-93
    • /
    • 1991
  • The specified industrial wastes increased 26% annually during the last 5 years from 1984 to 1988 in Korea, and the special treatment and proper management are required. The effective methods are studied on the process of generation, keeping, transportation, and treatment/disposal for specified industrial wastes and materials. Also, in this paper, the author describes the plans to develop the public disposal facilities and manage specific industrial waste properly in Korea.

  • PDF

Investigation of Nanoparticle Generation during Surface Decontamination by Low-Energy-Fluence Laser Ablation (저에너지 플루언스(fluence) 레이저 어블레이션(ablation)을 통한 표면오염제거과정에서의 나노입자의 생성에 관한 연구)

  • Lee, Doh-Won;Cheng, Meng-Dawn
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.11a
    • /
    • pp.199-199
    • /
    • 2003
  • During the cleanup of US Department of energy facilities, contaminated materials, toxic and hazardous radionuclides (e.g., Th, Cs, and U) and heavy metals (e.g., Cr, Hg, Pb, and Ni)-laden ultrafine particles are generated. The size of the particles is up to about 200 nm. Understanding of the production of these nanometer size particles is critical in determining the surface cleaning efficiently. (omitted)

  • PDF

Characteristics of Volatile Organic Compounds from Newly Produced Building - Apartment House

  • Lee, Jeong-Joo;Kim, Jeong-Ho;Kim, Shin-Do
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2004.06a
    • /
    • pp.223-226
    • /
    • 2004
  • Building materials emit high concentration volatile organic compounds(VOCs), formaldehyde(HCHO) and other hazardous air pollutants(HAPs) to indoor environment. Average value of VOCs and HCHO emission concentration were $3,770\;{\mu}g/m^3$, $430\;{\mu}g/m^3$ in newly buildings, respectively. VOCs and HCHO emission characteristic are high emission level at initial time and decreased in course of time.

  • PDF

The Characteristic of Volatile Organic Compounds(VOCs) Emission from the Type of Indoor Building Materials as the Temperature and Humidity (온.습도에 따른 건축 내장재별 휘발성유기화합물의 방출특성)

  • Seo, Byeong-Ryang;Kim, Shin-Do;Park, Seong-Kyu
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.4 s.91
    • /
    • pp.292-303
    • /
    • 2006
  • The Volatile Organic Compounds(VOCs) are emitted from various sources and have lots of different form. Recently human are spending the many times at indoor area and indoor air pollution is issued the important social problem. The emission sources of indoor air pollutants are very various, also indoor building materials are composed of very complex chemical compounds, these indoor building materials discharge very much VOCs and other hazardous compounds. In this study, we performed the small chamber test to investigate the VOCs emission concentration and characteristics involving five kinds of the indoor building materials(furniture material, wooden floor, wall paper, paint and tile) under different conditions of four temperature and relative humidity as account of the air flow rate(AFR), air exchange rate(AER), loading factor and air velocity respectively. As the result, It was showed that building materials are emitted the highest VOCs concentration at the beginning of experiment and furniture material is emitted the highest VOCs concentration. Most of the materials were affected by temperature, but paint and tile material were affected by humidity.

Fire Characteristics for Spill Rate of Light oil and Methanol (경유와 메탄올의 유출속도에 따른 화재특성)

  • Lee, Jung Yun;Kim, Hong
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.5
    • /
    • pp.54-60
    • /
    • 2016
  • In this study, tank truck incidents of road transport of hazardous materials to experimental investigated the potential fire hazard. Real scale fire was to perform experiments for on this qualitative and quantitative data collection and analysis. Particularly affected by radiant heat from the flames caused and damage estimates range investigated accordingly. Flame temperature, internal temperature of tank and emitted radiation from the flames was investigated. The flame of light oil spill caused a fire at a temperature of about $300^{\circ}C$ high in comparison with the methanol by combustion of diesel and methanol, according to the difference, the flame duration changes varies depending on the Burning rate. Depending on spill rate(30, 60, 90 and $120{\ell}/min$) and the longer the duration of the flame important factors for the internal temperature of tank lorry rise was found. Road accident in a fire caused by leakage of hazardous was could the higher the damaged. Therefor, Fire suppression activities should be required in particular to be around.

Actual Condition and Reliability Monitoring of Material Safety Data Sheets for the Organic Solvents (일부 유기용제의 물질안전보건자료의 실태와 신뢰성 조사)

  • 정규혁;김경례;김대현;오기석;유일재
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.4
    • /
    • pp.85-91
    • /
    • 2001
  • The regulation of Material safety data sheets(MSDS) was required for the chemicals in use in the workplace from July 1976. Under the provisions of the workplace hazardous materials information system, employers in Korea must be provided with accurate and comprehensive MSDS. To examine the reliability of MSDS for organic solvents, 63 organic solvents and MSDS were collected from the workplace of 39 companies located in Kyonggi province. Manufacture\`s MSDS were compared with the actual composition of the collected samples, and further examined the reliability by checking whether the chemicals analyzed were included in the MSDS correctly. 38 solvents were able to analyze their composition by gas chromatography-mass selective detector(GC-MSD). Among them, 28 solvents were incorrect in their composition and contents. In some case, health hazardous or carcinogenic chemicals which were not included in the MSDS were detected from samples. As a result of evaluating whether the MSDS correspond to the regulation required by Industrial Safety and Health Act (ISHA), the information in the MSDS including hazard classification, occupational exposure level, toxicity, regulatory information were incorrectly provided, and some MSDS did not disclose carcinogenic in their MSDS, and some MSDS were not written in the standard format. From this survey, continuous monitoring and promoting correct MSDS, and analyzing the components of the solvents were required to endure the reliability of MSDS for organic solvents.

  • PDF

A Study on the Characteristic Evaluation of Sewage and Industrial Wastewater Treatment Sludges by Physico-chemical Analysis (물리화학적 분석을 통한 하 ${\cdot}$ 폐수처리 슬러지류의 특성평가)

  • Kwon, Gi-Hong
    • Journal of Environmental Health Sciences
    • /
    • v.31 no.1
    • /
    • pp.86-93
    • /
    • 2005
  • Because generally large amount of sludges are generated from the process of sewage and wastewater treatment, the management and controlment of those sludge has become a important issue in many researches. In this dissertation, we conducted the research to see the physico-chemical characteristics of sludges generated from various sources. Moisture of sludges were 81.5% in textile industries, 81.4% in frame metal industries, 80.7% in 1st metal industries. Volatile solid were 22.1% in hide · rubber industries, 21.9% in coke · petroleum industries. Fixed solid were 18.5% and 17.7% in the 1st metal industries and frame metal industries. High heating value by wet base were 1,850 kcal/kg in coke · petroleum industries, 1,220 kcal/kg in hide · rubber industries, but sludges from the 1st metal industries and frame metal industries were impossible to incinerate because most of those sludges were inorganic. The leaching test showed that hazardous materials was detected in nearly every kinds of sludges. Some of sludges from hide · rubber industries and frame metal industries exceeded the leaching criteria and so they were classified as specific wastes. And other sludges generated in sewage treatment plants or other industries was below the leaching criteria.

Equipment Reliability Database for Chemical Plants (화학공장 설비 및 기기에 대한 신뢰도 데이터베이스 구축)

  • Ko Jae-Wook;Kwon Hyuk-Myun
    • Journal of the Korean Institute of Gas
    • /
    • v.10 no.1 s.30
    • /
    • pp.13-18
    • /
    • 2006
  • Chemical plants should perform Quantitative Risk Assessment that evaluates types of accident, frequency and damage which can happen through using the hazardous equipment and the hazardous materials for preventing and preparing industrial disasters. It is necessary that Chemical plants should include the reliability database which efficiently evaluate the Quantitative Risk Assessment. So in this study, we suggest a which methodology applies Quantitative Risk Assessment on the basis of the constructed data to imply the reliability of industrial facilities and equipment, collection of reliability data, system analysis and development of software.

  • PDF

Impermeable Standards for the Concrete Bottom of Dikes for Crude Oil Storage Tanks (원유저장탱크 방류벽의 콘크리트 바닥재 불침투성 세부기준 연구)

  • Shin, Changhyun;Park, Jai Hak;Yoon, Junheon
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.1
    • /
    • pp.54-60
    • /
    • 2016
  • The bottom of dikes must be kept impermeable to control hazardous chemicals spilled from storage tanks. Currently, insufficient related chemical control laws lead to a possibility to spread through the bottom. Generally, due to the high cost of installation and periodical maintenance, many businesses prefer to install the bottom with general concrete. But, since the impermeability of concrete is dependent on the kind of materials and chemical reaction, all concrete cannot be considered as impermeable material. Thus, it is necessary to make the installation standards of the dike bottom clear in order to avoid the argument over the impermeability and prevent the chemical accident. This study has suggested the standards of impermeable concrete by conducting 7-day exposure test to crude oil with the pilot dikes. The results have showed that the standards have the better impermeable performance compared with the germany standard, which have been penetrated at the maximum penetration depth of 1.9 cm. This study is expected to contribute to both the risk reduction of penetrating into the bottom and the cost reduction of spending to make the bottom of dikes impermeable.

Evaluation on Emission Characteristics of Trace Hazardous Material from Motorcycle Exhaust by EURO III (EURO III에 의한 이륜자동차의 미량유해물질 배출특성평가)

  • Yoo, Heung-Min;Son, JiHwan;Park, Gyu-Tae;Mun, SunHee;Yun, ChangWan;Kim, JeongSoo;Lee, JongTae
    • Journal of ILASS-Korea
    • /
    • v.20 no.4
    • /
    • pp.207-216
    • /
    • 2015
  • Recently, the researches for air pollutant control technologies have been performing in Korea, while considering an one of the latest main topics as problems on air pollutant control. However, it is difficult to investigate emission amount of air pollutant by passenger cars, because of lack of the domestic information about mobile source; the number of research institutes are less in the whole. Especially, the informations on registered numbers and emissions of motorcycles are less. Thus, in this study, the analysis that is based on experimental results was conducted for finding out source profiling and emission characteristics on motorcycles exhaust. For these experiments, the domestic motorcycles were chosen and evaluated by EURO III standard. From the result, controlled pollutants (CO, HC, NOx) were met to EURO III, but low displacement motorcycles showed a higher incomplete combustion reaction than that of 250 cc motorcycles. Additionally, uncontrolled pollutants (BTEX and 1,3-butadiene) were decreased with increasing a displacement of motorcycles. However, the emission trend of aldehydes was not followed that of those; the formaldehyde ratio increased upto approximately 33%, with increasing a displacement of motorcycles. In the future, it would be used to support the CAPSS as basic data of Korea.