• 제목/요약/키워드: Hazardous area classification

검색결과 35건 처리시간 0.019초

Operating Pressure Conditions for Non-Explosion Hazards in Plants Handling Propane Gas

  • Choi, Jae-Young;Byeon, Sang-Hoon
    • Korean Chemical Engineering Research
    • /
    • 제58권3호
    • /
    • pp.493-497
    • /
    • 2020
  • Hazardous area classification is designed to prevent chemical plant explosions in advance. Generally, the duration of the explosive atmosphere is used for zone type classification. Herein, IEC code, a quantitative zone type classification methodology, was used to achieve Zone 2 NE, which indicates a practical non-explosion condition. This study analyzed the operating pressure of a vessel handling propane to achieve Zone 2 NE by applying the IEC code via MATLAB. The resulting zone type and hazardous area grades were compared with the results from other design standards, namely API and EI codes. According to the IEC code, the operating pressure of vessels handling propane should be between 101325-116560.59 Pa. In contrast, the zone type classification criteria used by API and EI codes are abstract. Therefore, since these codes could interpret excessively explosive atmospheres, care is required while using them for hazardous area classification design.

IEC 60079-10-1 edition 2.0에 의한 방폭 설계 한계점 보완 방법에 관한 연구 (A Study on Complementary Method for Hazardous Area Extent by IEC 60079-10-1 Edition 2.0)

  • 최재영;변상훈
    • 대한안전경영과학회지
    • /
    • 제22권2호
    • /
    • pp.73-82
    • /
    • 2020
  • IEC 60079-10-1 edition 2.0, the global standard for hazardous area classification, was newly revised in 2015. There are many differences compared to the previous edition 1.0 version, first released in 2008, so it has caused confusion in the industry. In case of edition 1.0, the hazardous area extent can be derived through the mathematical formula, but in case of edition 2.0, there was the problem that the exact hazardous area extent was not known because of the mathematical formula of the plot for applying the hazardous area extent was not presented. In this study, we converted the plot introduced in edition 2.0 to CAD format and derived the plot as the mathematical equations. Through this, we suggest the hazardous area extent formula of three states (heavy gas, diffusive, jet). As the IEC committee did not provide the mathematical formula of the hazardous area extent according to the release characteristic, it is impossible to apply the exact hazardous area extent. In this study, a mathematical approach was derived for the plot introduced in edition 2.0, which can reduce the confusion of the applying hazardous area extent.

국내 방폭전기 안전 기준 제정 배경 및 방폭지역 구분 요령

  • 정재종
    • 방재기술
    • /
    • 통권15호
    • /
    • pp.22-27
    • /
    • 1993
  • The classification of hazardous area is a method of analysing and classifying the environment where explosive gas or vapour atmosphere may be expected to be present. The object of area classification is to enable the proper selection and installation of electical apparatus and other equipments. This report is intended to serve a general reference about the classification procedure of hazardous area with explanations of related Korean Standard.

  • PDF

LNG를 사용하는 설비에서의 폭발위험장소 적용 및 구분에 대한 제도/기술적 접근방안 (Technical/Systemic Approach to Safety Assesment of Thermoprocessing Equipment Consuming LNG for Classification of Hazardous Area)

  • 최상원
    • 한국안전학회지
    • /
    • 제26권5호
    • /
    • pp.33-40
    • /
    • 2011
  • In the hazardous areas where explosive liquids, vapors and gases exist, electrical apparatus/equipment should have explosion-proof construction. The consuming of liquefied natural gas(LNG) has markedly increased in the industrial field, especially in aspect of some thermoprocessing equipment, boiler, dryer, furnace, annealer, kiln, regenerative thermal oxidizer(RTO) and so on. Because it has many merits, clean fuel, safety, no transportation/storage facility and so on. It is strongly recommend that the classification of hazards has to be decided to prevent and protect explosion which may occur in thermoprocessing equipment. In this paper, the operated thermoprocessing equipments in industrial area investigated and explosion risk assessment about LNG leakage from its facilities was performed through numerical calculation and computer simulation. Finally, we suggest the systemic/technical approach for safety assessments of thermoprocessing equipments consumed LNG fuel which are specially subjected to classification of hazardous area.

가스 누출 실험, CFD 및 거리산출 비교를 통한 LP가스 누출 검지농도 분포에 대한 고찰 (A Comparison on Detected Concentrations of LPG Leakage Distribution through Actual Gas Release, CFD (FLACS) and Calculation of Hazardous Areas)

  • 김정환;이민경
    • 공업화학
    • /
    • 제32권1호
    • /
    • pp.102-109
    • /
    • 2021
  • Recently, an interest in risk calculation methods has been increasing in Korea due to the establishment of classification code for explosive hazardous area on gas facility (KGS CODE GC101), which is based on the international standard of classification of areas - explosive gas atmospheres (IEC 60079-10-1). However, experiments to check for leaks of combustible or toxic gases are very difficult. These experiments can lead to fire, explosion, and toxic poisoning. Therefore, even if someone tries to provide a laboratory for this experiment, it is difficult to install a gas leakage equipment. In this study we find out differences among actual experiments, CFD by using FLACS and calculation based on classification code for explosive hazardous area on gas facility (KGS CODE GC101) by comparing to each other. We develpoed KGS HAC (hazardous area classification) program which based on KGS GC101 for convenience and popularization. As a result, actual gas leak, CFD and KGS HAC are showing slightly different results. The results of dispersion of 1.8 to 2.7 m were shown in the actual experiment, and the CFD and KGS HAC showed a linear increase of about 0.4 to 1 m depending on the increase in a flow rate. In the actual experiment, the application of 3/8" tubes and orifice to take into account the momentum drop resulted in an increase in the hazardous distance of about 1.95 m. Comparing three methods was able to identify similarities between real and CFD, and also similarities and limitations of CFD and KGS HAC. We hope these results will provide a good basis for future experiments and risk calculations.

폭발위험장소 선정 시 풍속 변화에 관한 연구 (The Effect of the Change of Wind Velocity on the Classification of Explosion Hazardous Area)

  • 권용중;김동준
    • 한국위험물학회지
    • /
    • 제6권2호
    • /
    • pp.62-67
    • /
    • 2018
  • It is very important to classify explosion hazardous area in order to prevent an accident explosion. In order to prevent such a explosion, the Industrial Safety and Health Standards Rules stipulates the establishment and management of explosion hazards in accordance with the criteria set by the Korean Industrial Standards. This study has investigated the range of the explosion hazardous area according to various hole sizes, pressures, vapor densities, and wind velocities in the outdoor flammable liquid tank using KS C IEC-60079-10-1 $2^{nd}$ Ed.(=IEC CODE) and PHAST. The results show that the explosion hazardous areas by IEC CODE have circle shapes. However, the areas by PHAST show ellipse shapes. The different of the explosion hazardous areas increases with the increase of wind velocity.

열매체 가열기 설비에서의 폭발위험관리에 관한 연구 (A Study on Explosion Risk Management for Hot Oil Heater)

  • 장철;권진욱;황명환
    • 대한안전경영과학회지
    • /
    • 제19권3호
    • /
    • pp.1-9
    • /
    • 2017
  • In the industrial field, various type of fuel have been used for product processing facilities. Recent for 10 years, the usage of natural gas (NG) was gradually increased. Because it has many merits; clean fuel, no transportation, storage facility and so on. There are common safety concept that strict explosion protection approaches are needed for facilities where explosive materials such as flammable liquid, vapor and gases exist. But some has an optimistic point of view that the lighter than air gases such as NG disperse rapidly, hence do not form explosion environment upon release into the atmosphere, many parts has a conventional safety point of view that those gases are also inflammable gases, hence can form explosion environment although the extent is limited and present. In this paper, the heating equipments (Hot Oil Heater) was reviewed and some risk management measures were proposed. These measures include hazardous area classification and explosion-proof provisions of electric apparatus, an early gas leak detection and isolation, ventilation system reliability, emergency response plan and training and so on. This study calculates Hazardous Area Classification using the hypothetical volume in the KS C IEC code.

인화성액체의 폭발위험장소 설정을 위한 증발율 추정 모델 연구 (A Study on the Estimation Model of Liquid Evaporation Rate for Classification of Flammable Liquid Explosion Hazardous Area)

  • 정용재;이창준
    • 한국안전학회지
    • /
    • 제33권4호
    • /
    • pp.21-29
    • /
    • 2018
  • In many companies handling flammable liquids, explosion-proof electrical equipment have been installed according to the Korean Industrial Standards (KS C IEC 60079-10-1). In these standards, hazardous area for explosive gas atmospheres has to be classified by the evaluation of the evaporation rate of flammable liquid leakage. The evaporation rate is an important factor to determine the zones classification and hazardous area distance. However, there is no systematic method or rule for the estimation of evaporation rate in these standards and the first principle equations of a evaporation rate are very difficult. Thus, it is really hard for industrial workplaces to employ these equations. Thus, this problem can trigger inaccurate results for evaluating evaporation range. In this study, empirical models for estimating an evaporation rate of flammable liquid have been developed to tackle this problem. Throughout the sensitivity analysis of the first principle equations, it can be found that main factors for the evaporation rate are wind speed and temperature and empirical models have to be nonlinear. Polynomial regression is employed to build empirical models. Methanol, benzene, para-xylene and toluene are selected as case studies to verify the accuracy of empirical models.

수전해설비의 전기방폭 기준 만족을 위한 비방폭화 방안에 관한 연구 (A Study on the Non-Hazardous Method for complying with the Explosion Proof Criteria of the Electrolysis)

  • 김용규;한신탁;박종범;공병찬;박계준;정승호
    • 한국가스학회지
    • /
    • 제26권6호
    • /
    • pp.65-75
    • /
    • 2022
  • 최근 수전해설비의 운전압력이 증가함에 따라 수소 누출로 인한 화재 및 폭발 가능성 및 위험성 또한 증가하고 있다. 따라서 관계법령 및 기술기준에 따라 수전해 시스템에 설치되는 모든 전기기에 전기방폭 형식인증 제품을 사용하거나 적절한 방법에 따른 비폭발위험장소화 절차를 적용해야 한다. 본 연구에서는 수전해설비의 일반적인 운전조건을 고려하여 KS C IEC 60079-10-1 및 KGS GC101에 따른 폭발위험장소 구분 및 범위 산정을 수행하였다. 또한, 비폭발위험장소화를 달성하기 위해 임계농도인 폭발하한 25 % 미만의 농도를 유지하기 위한 적정 환기량을 검토하였다. 그 결과 자연환기만 적용할 경우에는 수전해설비가 폭발위험장소로 구분되고, 이를 강제환기를 통해 비폭발위험장소로 구분하기 위해서는 막대한 환기량이 필요함을 확인할 수 있었다.

가상체적을 이용한 폭발위험장소 구분의 타당성 검토 (Validity Review on Classification of Explosion Hazardous Area using Hypothetic Volume)

  • 임지표;정창복
    • 한국안전학회지
    • /
    • 제29권6호
    • /
    • pp.68-75
    • /
    • 2014
  • It is very important to classify explosion hazardous area (EHA) suitably and to use proper explosion-proof electric installations for facilities using flammable gases and liquids. In the past, various examples in the Notification of Ministry of Employment and Labor were referred to in classifying EHA. But, at present, many companies use the hypothetical volume in Korean Standards (KS). This study reviews the validity of EHA classification based on the hypothetical volume by comparing the calculated radii of EHA with those obtained by a consequence analysis program called PHAST and a mathematical approach in British Standards (BS). The radii of EHA by the hypothetical volume were found to be slightly larger than those by the other two methods. This was attributed to rather conservative uses of a safety factor(k) and a correction factor(f) for availability of ventilation in calculating the hypothetical volume. Since the differences are not so conspicuous, however, it is concluded that the hypothetical volume in KS is a valid means for the classification of EHA. This study also presents a table of the radii of EHA for easy reference by small-scale companies using city gas, C3-LPG and flammable liquid(toluene), respectively. The table consists of 25 leakage scenarios corresponding to combinations of 5 pipe(nozzle) sizes and 5 operating conditions for each flammable gas and liquid.