• Title/Summary/Keyword: Hazardous and harmful substances

Search Result 49, Processing Time 0.029 seconds

Reviews on Adsorption and Catalyst Technology for Removal of Hazardous Substances from Semiconductor Process (반도체 공정에서 발생하는 유해물질 제거를 위한 흡착 및 촉매 공정에 대한 고찰)

  • Yoon, Seong-Jin;Kim, Yu-Jin;Kang, Yu-Jin;Jang, Min-Hyeok;Jo, Hyung-Kun;Han, Gyoung-Jae;Seo, Dong-Jin;Cho, Hye-Ryeong;Park, Joo-Il
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.30 no.4
    • /
    • pp.51-57
    • /
    • 2022
  • This paper investigated catalytic and adsorption equations among the technologies for removing hazardous substances generated in the semiconductor process. As the semiconductor industry develops, harmful substances used and discharged in the semiconductor process are also increasing. Hazardous substances adversely affect the global environment in terms of atmospheric and water quality. As regulations on the emission of harmful substances are strengthened in the 21st century, it is expected that there will be limitations in industrial development in the future. Therefore, technology for removing harmful substances generated in semiconductor processes is essential. In this paper, the goal is to remove PFCs, which are harmful substances, through adsorption technology and catalyst technology. Descriptions from the semiconductor process to the technology in which harmful substances generated are removed were summarized.

A Study on the Toys Assessment of Harmful Substances and Control (완구제품에 함유된 유해물질 및 관리방안에 대한 연구)

  • Kim, Seung-Don;Son, Ki-Sang
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.5
    • /
    • pp.27-32
    • /
    • 2010
  • This study is to investigate and compare domestic hazardous toys with harmful substances with foreign toys so that we can find out management criteria for in cognitive infants. Actually, commercially used toys have been collected and tested to find out more effective management standard. it is tried to produce evaluation criteria of environmentally harmful substance but variety of product is needed for overcoming actual barrier due to lot of difficulty huge cost, time, objectiveness. Therefore, This study does not cover all the above. Establishment of evaluation criteria for product harmfulness made by Government or Local government should be continued to improve. Foreign reference material for toy product in Europe, USA, Japan have been investigated and domestic product have been collected and tested for containing heavy metals, formaldehyde, phthalate in the study. All the test have been made in accordance with KSM ISO 2124 to measure heavy metal transfer into body. Toy product used for the study have been purchased in the real market and some of them contains harmful elements with over standard. Post management system such as RAPEX to control periodically should be established for plastic toy with low quality product.

Determination of PCDD/Fs in Disposable Diaper for Infant (유아용 일회용 기저귀의 다이옥신 분석)

  • Shin Jeoung Hwa;Ahn Yun Gyong;Seo Jung Ju
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.29 no.6
    • /
    • pp.814-824
    • /
    • 2005
  • This study analyzed and standardized the harmful substances of organic compounds(dioxins) in disposable diapers for infant's clothing. Commercial samples obtained from Korea, Japan, America and German were determined by HRGC/HRMS. Experimental Methods were consisted of comparision of extracting solvent, analysis of PCDD/Fs, and analysis of PCDD/Fs of extraction in disposable diaper. The results were as follows. No high TEQ values in TCDD(1), PCDD(0.5) and HxCDD(0.1) were found for commercial disposable diapers from country Korea, Japan, U.S.A and German. In extraction for 6hrs experiments, HpCDD and OCDD were detected in disposable diapers of U1, U2 and G2, respectively. In extraction fur 24hrs experiments, HpCDD, OCDD and OCDF were detected in disposable diapers of J3, U1, U2 and U3. So we need to set standards of measurement for harmful materials contained in textile goods. This will make a safe and comfortable clothing environment for all users, regardless of age.

Measurement of Hazardous Substances in Children's Goods at Schools in Seoul (휴대용 XRF를 이용한 서울시 학교 내 어린이용품 중 일부 유해물질 함량 조사)

  • Kim, KyooSang;Park, Hyunkyung;Choi, Gilyoung;Lim, Wanryong;Shin, Kyoojin
    • Journal of Environmental Health Sciences
    • /
    • v.43 no.3
    • /
    • pp.176-184
    • /
    • 2017
  • Objectives: Excluding in their homes, children spend most of their time at an elementary school, daycare center, and/or kindergarten. For educational or recreational purposes, they make use of many children's goods at these places. Some children's goods contain phthalates and heavy metals with polyvinyl chloride (PVC), so due to their physiological and behavioral characteristics children are exposed to high concentrations of phthalates and heavy metals. This study aims to measure PVC and heavy metals, which are harmful substances in children's goods which can have an effect on children's health. Methods: Six samples of children's goods were selected through cases of detected harmful substances and the results of previous research, including assembly blocks, model toys, household toys, bags, indoor play equipment, and floor mats. The selected items were measured using X-Ray Fluorescence (XRF), and the presence and content of environmentally harmful substances such as PVC or heavy metals in the materials of children's goods were examined. Results: The highest detection rate for PVC was observed in floor mats, and bags and indoor play equipment were higher than other goods in this regard. The highest detection rate for heavy metals was found in bags, followed by indoor play equipment, assembly blocks, household toys, model toys and floor mats. Except for bags containing heavy metals, five goods showed the highest level of Pb compared to other heavy metals. Floor mats contained the highest level of Pb, Cr, and Cu among all goods. Conclusion: Many children's goods contain PVC and heavy metals, and high levels of heavy metals have been detected in some goods. It is necessary to manage children's goods to support their health.

Case Study on the Effluent Guidelines of Foreign Cases for the Development of Hazardous Noxious Substances (HNS) from Marine Industrial Facilities Management Guidelines, Korea: Focusing on the US EPA Guidelines (국내 해양산업시설의 위험유해물질 배출 관리 지침개발을 위한 국외 사례 검토: US EPA 배출지침을 중심으로)

  • Ki-young Choi;Chang-joon Kim;Young-Il Kim;Won-Soo Kang;Moonjin Lee
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.spc
    • /
    • pp.44-49
    • /
    • 2022
  • It is necessary to establish a marine environment management system in Korea for hazardous noxious substances (HNS) effluent from marine industrial facilities because the Marine Environment Management Act primarily focuses on pollution control from vessels and offshore man-made structures. In this study, we investigated the effluent guidelines of foreign cases focusing on the US Environmental Protection Agency (US EPA), which provides detailed information on the action levels and establishing principles for the industrial wastewater discharge of HNS. Based on the review, we also considered appropriate options for establishing new guidelines for Korea.

A study on the supply status of chemical substance information including MSDS and a way of improving Database management in Korea (국내 MSDS 등 화학물질정보의 제공실태와 DB관리 개선방안 연구)

  • Lee, Kwon Seob;Yoon, Seok Joon;Choi, Jae Wook;Kim, Hyun Ock;Lee, Jong Han;Yang, Jeong Sun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.17 no.1
    • /
    • pp.63-70
    • /
    • 2007
  • This study investigated the current management staus of chemical substance information on Material Safety Data Sheets(MSDS) and Chemical Information Cards(CIC) provided by Korea Occupational Safety & Health Agency(KOSHA) and also researched the kind and the characteristics of chemical substance information provided in other organizations. MSDS DB in Korean provided on KOSHANET(which is Kosha website) is 50,802 in total, among whom are single chemical substances with 31,870 kinds(18,932%) and are mixed chemical substances with 31,870 kinds(62.7%). The number of visiting MSDS DB on KOSHANET for the search of chemicals was 2,049,806. The number has increased each year. The CIC provided for workplaces is all 542 kinds : 14 harmful substances subject to permission, 168 harmful substances subject to management, 360 KOEL(Korean Occupational Exposure Limits) establishment substances. MSDS internationally provided by organizations producing MSDS DB was written with 16 sections, which is suitable for the writing basis of American Standards Institute(ANSI) and International Organization for Standardization(ISO) and provided chemical substance information on more than 100,000 kinds in most organizations.

Fast Screening of Harmful Disinfectants in Household Products via Low-Temperature Plasma Ionization-Mass Spectrometry

  • Lee, Hyoung Jun;Kweon, Gi Ryang;Yim, Yong-Hyeon
    • Mass Spectrometry Letters
    • /
    • v.8 no.2
    • /
    • pp.44-47
    • /
    • 2017
  • Isothiazolinone derivatives are widely used in consumer products as disinfectants or preservatives, but there are growing concerns about their impact on human health. Therefore, rapid screening of these biocides is very important for proper control and regulation of potentially hazardous substances. To this end, low-temperature plasma (LTP) ionization mass spectrometry (MS) was investigated to demonstrate its potential for direct and selective analysis of isothiazolinones from sprayed aerosol samples. Benzisothiazolinone (BIT) was clearly identified from a commercial fabric deodorant using LTP ionization MS and MS/MS. LTP allowed selective ionization of BIT directly from the simply sprayed aerosol sample and illustrated its potential for fast screening without sample pre-treatments. Selective nature of LTP ionization, on the other hands, implicates use of LTP ionization MS as a general screening method for specific groups of hazardous chemicals in commercial products.

A study on the Recognition of Material Safety Data Sheets and Safety of Handling Harmful Chemicals in Dental Hygienists (치과위생사의 물질안전보건자료 인식도와 유해화학물질 취급 시 안전 실태에 관한 연구)

  • Kim, Eun-Kyoung;Chung, Kyung-Yi
    • Journal of Digital Convergence
    • /
    • v.16 no.4
    • /
    • pp.185-194
    • /
    • 2018
  • The purpose of this study was to understand the dental hygienist's perception of dental materials and to understand the safety status of harmful chemicals. The study was conducted from January to February 2015 for 250 dental hygienists working in Gwangju Metropolitan City. as a result, the degree of recognition of MSDS for dental materials was higher with age (P <0.05) and higher in dental hygienist (P <0.001) working at dental hospital. (P <0.001), and the factors affecting the perception of first aid treatment were positively correlated with experience of hazard education (P <0.001). Therefore, by understanding the MSDS awareness of dental materials by dental hygienists and the safety situation in the handling of hazardous chemical substances, we provide basic data for establishing proper recognition of safety in the handling of harmful chemical substances and developing educational programs to prevent accidents.

A Study on Optimal Ventilation Design for Gas Boxes Installed in Semiconductor Manufacturing Equipment Handling Flammable Liquids (인화성 가스를 취급하는 반도체 제조장비에 설치된 가스박스 최적 환기 설계에 대한 연구)

  • Gyu Sun Cho;Sang Ryung Kim;Won Baek Yang
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.1
    • /
    • pp.63-69
    • /
    • 2023
  • Although Korea is the world's No. 1 semiconductor producing country, most studies are conducted with risk assessment for simple material risks due to the closedness of the site for industrial protection. In terms of industrial safety, a monitoring system such as a gas detector to determine the leakage of hazardous substances has been established, but research on effectively discharging harmful gastritis substances in case of leakage has only recently begun. Semiconductor manufacturing facilities (gas boxes) where a large amount of flammable materials are handled are currently being safety managed by using a gas detector and blocking the air inlet. It is difficult to dilute in a short time in case of leakage of flammable substances. Therefore, in this study, based on various criteria, the size of the duct according to the size of the gas box is determined and the appropriate size of the air inlet is studied to minimize the exhaust performance requirement without exposing hazardous chemicals to the outside in the event of a flammable leak. We want to do an optimal exhaust design.

Microplastic Management for Preventing Risk of Persistent/Bioaccumulative Substance (잔류성.생물축적성 물질 피해저감을 위한 미세플라스틱(Microplastic) 관리방안)

  • Park, Jeong-Gue;Gan, Sun-Yeong
    • Journal of Environmental Policy
    • /
    • v.13 no.2
    • /
    • pp.65-98
    • /
    • 2014
  • Plastics of the marine environment are broken gradually down into smaller particles by chemical weathering, called "microplastic". Microplastics absorb organic pollutants that are persistent bioaccumulative substances. If marine animals ingested microplastic added to contaminant, it will lead to a bioaccumation through the food web. It eventually destroy health of marine environment and is harmful to marine top predators including humans. Also, Microplastics can impact marine animals by leaching the endocrine disruptor in microplastic itself as well as playing an adsorbent role of organic pollutants. Persistent and bioaccumulative substances in Korea have been regulated in terms of chemical risk but existing regulations largely have been limited in land-based source management of microplastic. Thus, the harmful impact will be increased whether the microplastics absorbed contaminants. To prevent risk of persistent bioaccumulative substances, this study suggests the following: (1) the strict management of microplastic by designating the hazardous substances, (2) expand the use of biodegradable plastic, (3) the effort for reuse and recycle, (4) the expand of microplastic clean-up programs.

  • PDF