• Title/Summary/Keyword: Hazard investigation

Search Result 269, Processing Time 0.026 seconds

A Study on the Determination of Optimal Location and Size for Underground Sluiceway Design (지하방수로 설계를 위한 적정 위치선정 및 규모 결정에 관한 연구)

  • Lee, Jong-Tae;Lim, Taek-Sun;Hur, Sung-Chul;Park, Sang-Sik
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.5
    • /
    • pp.137-145
    • /
    • 2008
  • In this study, to reduce the flood damage caused by flood discharge exceeding project flood, the primary technology was applied to determining the optimal location and size for underground sluiceway. The Jungrang Stream was selected for this study because the stream was overflowed and the embankment section of the stream was destroyed owing to localized torrential rainfall in 1998 and 2001. Considering 200-year frequency storm, the inlets of the underground discharge channel were located at Seoul City limits, the confluence of Danghyun Stream, Wolgye 1-gyo, and the confluence of Mukdong Stream. The outlets were located at the estuary of Jungrang Stream and rightbank of Banpo Bridge in Han River. The transverse discharge according to the variation of overflow depth at the inlet of underground discharge channel was estimated and the effect of inundation reduction was analyzed. To examine the appropriate scale of the underground discharge channel, the 8 operation methods for the management of outlet discharge were compared considering four rules (only storage, the constant discharge rate, the constant discharge volume, and the mixture of the constant discharge rate and discharge volume). As a result, the effect of inundation reduction was most significantly improved when the inlet was located at the confluence of Danghyun Stream. The appropriate size of underground sluiceway for 200-year frequency storm was studied, and as a result, the appropriate diameters of the underground discharge channel were 12 m in case of only storage(Rule D), 9m in 50% of discharge(Rule E), 8 m in constant discharge volume(Rule F), and 7 m in mixture method(Rule G). This investigation process can be applied to design the underground discharge channel when the inundation damage is significant in coastal area due to embankment overflow. The underground discharge channel in Jungrang Stream can also be used as an underground road to link Seoul City to Uijeongbu City during dry season.

Investigation of Microbiological Hazard from Korean Leeks and Cultivation Area to Establish the GAP Model (Good Agricultural Practices (GAP)모델 개발을 위한 부추 및 생산환경에서의 위해요소 조사)

  • Park, Sang-Gon;Choi, Young-Dong;Lee, Chae-Won;Jeong, Myeong-Jin;Kim, Jeong-Sook;Chung, Duck-Hwa;Shim, Won-Bo
    • Journal of Food Hygiene and Safety
    • /
    • v.30 no.1
    • /
    • pp.28-34
    • /
    • 2015
  • This study is to investigate microbiological hazards which can be used as fundamental data to adequately control leeks hazards and develop leeks GAP model for those who want to get GAP system. The microbiological investigations on cultivation environments (soil and water), crops (leeks), personal hygiene (workers' hands, clothes and gloves) and working tools (boxes) have been conducted for one year, so the period was classified under non-cultivation, cultivation, and post harvest. Total bacteria was detected from soil (4.0~6.7 log CFU/g), leeks (4.6~5.1 log CFU/g), hands (ND~3.3 log CFU/hand) and gloves ($ND{\sim}5.4\;log\;CFU/cm^2$) while nothing was detected from the other samples. The coliform contamination of leeks (4.8~5.0 log CFU/g) was more high than that of soil (3.9~4.2 log CFU/g). In case of foodborne pathogens, only B. cereus was detected at the level of 0.5~4.6 log CFU/g (or hand, $100cm^2$). Fungi was observed at the level of 2.1~3.8 log CFU/g (or hand, $100cm^2$) excepting water and some working tools. These results demonstrate that the contamination of leeks is comparatively higher than that of soil sample. The reason may be the cross-contamination by biological hazards presenting on soil. Therefore, it is necessary to properly control soil and fertilizer for safety against biological hazards.

The Association between Periodontal Disease and Renal Disease Occurrence : A Retrospective Cohort Study (치주질환과 신장질환 발생과의 연관성: 후향적 코호트 연구)

  • Seon-Ju Sim;MinHee Hong;Ja-Young Moon;Hye-Sun Shin
    • Journal of Korean Dental Hygiene Science
    • /
    • v.7 no.1
    • /
    • pp.53-68
    • /
    • 2024
  • Background: Research on the association between renal disease and periodontal conditions has yet to yield definitive results. In this study, we analyzed whether periodontal disease increases the risk of developing renal disease using Korean national cohort data over a period of 11 years. Methods: From 2002 to 2015, a retrospective follow-up investigation was conducted on the 203,538 Korean population using the National Health Insurance Service-National Sample Cohort. Periodontal disease and renal disease were identified through diagnoses using the International Statistical Classification of Diseases and Related Health Problems, 10th revision (ICD-10) codes. The assessment of periodontal status involved considering the number of dental visits related to periodontal disease during the baseline 3-year period. Results: During the 11-year follow-up period, renal disease occurred in 19,868 out of the total 203,538 individuals. After adjusting for age, gender, income, smoking, drinking, physical activity, diabetes, hypertension, obesity, hypercholesterolemia, ischemic heart disease, and advanced periodontal treatment, periodontal disease increased the risk of renal disease occurrence by 1.04 times (adjusted hazard ratio [aHR] = 1.04, 95% CI = 1.01 to 1.08). Additionally, a higher frequency of dental visits attributed to periodontal disease was associated with an increased risk of renal disease,exhibiting a dose-response trend (aHR = 1.02, 95% CI = 1.00 to 1.06 for once; aHR = 1.08, 95% CI = 1.04 to 1.13 for two times; aHR = 1.11, 95% CI = 1.03 to 1.21 for three times). Conclusions: Our data confirmed that periodontal disease is associated witha higher incidence of renal disease.

Prognostic Role of Hypoxic Inducible Factor Expression in Non-small Cell Lung Cancer: A Meta-analysis

  • Li, Cong;Lu, Hua-Jun;Na, Fei-Fei;Deng, Lei;Xue, Jian-Xin;Wang, Jing-Wen;Wang, Yu-Qing;Li, Qiao-Ling;Lu, You
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.6
    • /
    • pp.3607-3612
    • /
    • 2013
  • Introduction: Reported prognostic roles of hypoxic inducible factor (HIF) expression in non-small cell lung cancer (NSCLC) have varied. This meta-analysis aimed to examine the relationship between HIF expression and clinical outcome in NSCLC patients. Methods: PubMed were used to identify relevant literature with the last report up to December $20^{th}$, 2012. After careful review, survival data were collected from eligible studies. We completed the meta-analysis using Stata statistical software (Version 11) and combined hazard ratio (HR) for overall survival (OS). Subgroup specificity, heterogeneity and publication bias were also assessed. All of the results were verified by two persons to ensure accuracy. Results: Eight studies were finally stepped into this meta-analysis in which seven had available data for HIF-$1{\alpha}$ and three for HIF-$2{\alpha}$. Combined HRs suggested that higher expression of $HIF1{\alpha}$ had a negative impact on NSCLC patient survival (HR=1.50; 95%CI=1.07-2.10; p=0.019). The expression of HIF-$2{\alpha}$ was also relative to a poorer survival (HR=2.02; 95%CI=1.47-2.77; p=0.000). No bias existed in either of the two groups. Conclusion: This study suggests that elevations of HIF-$1{\alpha}$ and HIF-$2{\alpha}$ expression are both associated with poor outcome for patients with NSCLC. The data support further and high quality investigation of HIF expression for predicting poor outcome in patients with NSCLC.

Investigation on Response Modification Factor of RC Structural Walls in Apartment Buildings (아파트 건물의 구조 벽체에 대한 반응수정계수)

  • 한상환;오영훈;이리형
    • Journal of the Korea Concrete Institute
    • /
    • v.13 no.6
    • /
    • pp.544-552
    • /
    • 2001
  • Korea is classified into low and moderate seismic zone from the view-point of seismic hazard level. Korean seismic provisions has been developed based on UBC and ATC 3-06. Thus, in calculation of design base shear according to Korean provisions response modification factor (R) is included in the formula of design base shear. The major role of this factor is to reduce the elastic design base shear whereby structures can behave in inelastic range during design level earthquake ground motions(mean return period of 475 yrs.). R factor is assigned according to material and structural systems. In this study, R factor for bearing wall system is considered. Most of the walls of apartment buildings in Korea resist gravity and seismic loads simultaneously so that this wall system can be classified into bearing wall system. Structural details of these walls are different from those used in Japan and U.S.. They are all rectangular in sectional shape rather than barbell in shape, and also have special lateral reinforcement details at the boundaries of a wall. In Korean seismic design provisions(1988), two different values(3.0 and 3.5) of R factor are assigned to the bearing wall systems according to the wall details. However, in updated seismic provisions(2000), only one value is assigned to R factor(3.0) irrespective of wall details. In this study, the design base shear values in Korean seismic design provisions(1988, 2000), ATC 3-06, UBC are compared. Also experimental study was carried out to evaluate the seismic performance of structural walls. For this purpose, five test specimens were made which have special details used in apartment bearing wall systems in Korea. Based on the results of this study, response modification factor for bearing wall system is discussed.

International Tendencies for Estavlishing a Microbiogical Standard for Food (식품의 미생물 규격기준의 국제적동향)

  • 신광순
    • Journal of Food Hygiene and Safety
    • /
    • v.1 no.1
    • /
    • pp.77-95
    • /
    • 1986
  • In 1962 the governing bodies of FAO and WHO approved the establishment of a joint FAO/WHO Food Standards Programme, the creation of a jointly sponsored body to be known as the Codex Alimentarius commission to implement the Programme. It can reasonably be claimed that the Commission has assumad the leading role in establishing internation food standards throughout the world. The Codex Committee of Food Hygiene has received much advice and assistance from other international organization which have been working in this field for a number of years. In particular, it has received valuable background documentation from the International Commission on Microbiological Specifications for Foods(ICMSF) which was set up by the International Association of Microbiological Societies(IAMS), and also from the International Organization for Standardization (ISO). Nevertheless, in spite of the information supplied by governments and research bodies in this field, microbiological standards have proved to be a highly controversial subject from the point of view of Codex standards. When it is decided to establish a microbiological standard for a food or class of foods, the following technical and administrative aspects must be considered: 1) The standard should be based on factual studies and serve one or more of the following objectives: (1) to determine the conditions of hygiene under which the food should be manufactured; (2) to minimize the hazards to public health; (3) to measure the keeping quality and storage potential of the food 2) The standard should be attainable under practicable operating and commercial conditions and should not entail the use of excessive heat treatment or the additions of extra preservatives. 3) The standard should be determined after investigation of the processing operation. 4) The standard should be as simple and inexpensive to administer as possible, the number of tests being kept to a minimum. 5) Details of methods to be used for sampling, examining and reporting should accompany all published microbiological standards. 6) In establishing tolerance levels for the permissible number of defective samples, allowance should be made for sampling and other variations due to differences in the laboratory methods. The following additional points should be kept in mind: 1) It is not satisfactory to establish one set of microbiological standards for a miscellaneous group of foods, such as“frozen foods”or“precooked foods”. 2) Microbiological standards should be applied first to the more hazardous types of food on the basis of experience of expected microbiological levels, taking into account variations in composition, processing procedures, and storage. 3) When a standard is established, there should be a definite relationship between the standard and the hazard against which it is meant to protect the public. 4) The sensitivity, reliability, and reproducibility of the sampling and analytical methods should be compared in different laboratories and the methods to be used should be specified in detail as part of the standard. 5) Tolerances should be included in the standard to account for inaccuracies of sampling and analysis. 6) Standards should be applied on a voluntary basis before compliance is made mandatory.

  • PDF

A Investigation on Inelastic Lateral-Torsional Buckling Strength of I-Beam with Load Height Effects (하중고 효과가 비탄성 I형보의 횡-비틀림 좌굴거동에 미치는 영향 고찰)

  • Park, Yi Seul;Yoo, Sang Ryang;Oh, Jeong Jae;Park, Jong Sup
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.155-155
    • /
    • 2011
  • 일반적으로 I형 보에 횡하중이 작용하는 경우, 횡 변위와 함께 회전을 동반하는 횡-비틀림 좌굴(Lateral-Torsional Buckling)이 발생하게 된다. 이러한 I형 보의 탄성 및 비탄성 횡-비틀림 좌굴에 대한 해석적 이론적 연구는 이미 많은 연구자들에 의해 수행되었다(Timoshenko 등, 1961; Galambos, 1963; Lindner, 1974; Trahair, 1993). I형 보의 비지지 길이 내 하중이 작용할 때 모멘트 구배계수(Cb)는 하중이 부재 단면에 작용하는 위치에 따라 달라지게 되는데 이를 하중고 효과(Load Height Effects)라고 한다. 탄성 영역 내 비지지길이가 존재하는 I형 보의 하중고 효과를 고려한 모멘트 구배계수 제안식은 Nethercot & Rockey(1971)에 의해 연구된 바 있다. 또한 Helwig 등(1997)은 Nethercot & Rockey(1971)의 제안식을 간략화 하여 탄성 영역 내 비지지길이가 존재하는 I형 보의 하중고 효과를 고려한 모멘트 구배계수식을 제안하였다. 그러나 현재까지 진행 된 하중고 효과에 대한 연구는 탄성 영역 내 비지지 길이가 존재하는 I형 보에 대한 제안식이며 현재까지 비탄성 영역 내 비지지 길이를 갖는 I형 보의 하중고 효과에 대한 연구는 진행된 바 없다. 본 연구는 비탄성 영역 내 비지지 길이가 존재하는 I형 보의 하중고 효과를 고려한 비탄성 횡-비틀림 좌굴강도에 대한 연구를 수행하였다. 하중조건으로는 집중하중 과 등분포 하중을 적용시켰으며, 비선형 횡-비틀림 좌굴 해석을 위해 잔류응력 및 초기변형을 고려하였다. Pi와 Trahair(1995)이 고려한 단순직선분포를 잔류응력으로 가정하였으며, 국내 I형강 표준 치수 허용치(현대제철, 2006)에 근거하여 부재 길이의 0.1%를 초기 최대 횡 변위로 적용하여 초기제작오차로 고려하였다. 유한요소해석결과를 바탕으로 Nethercot & Rockey(1971)와 Helwig 등(1997)의 연구내용을 바탕으로 범용구조해석 프로그램(ABAQUS, 2007)을 이용하여 비탄성 영역 내 존재하는 I형보의 횡-비틀림 좌굴강도를 산정하였다. 유한요소해석결과를 바탕으로 Nethercot & Rockey(1971)및 Helwig 등(1997)의 모멘트구배계수 제안식과 비교 분석 하였고 회기분석프로그램 MINITAB(2006)을 이용하여 비탄성 영역 내 비지지길이가 존재하는 I형보의 하중고 효과를 고려한 모멘트구배계수식을 개발 제안하였다. 본 연구에서 개발된 제안식은 경제적이고 합리적인 휨부재 강도평가에 적극 활용될 수 있으며, 비탄성 영역내 I형보의 횡-비틀림 좌굴강도 및 휨강도 연구에 널리 활용될 것이다.

  • PDF

Age Dating and Paleoenvironmental Changes of the Kunang Cave Paleolithic Site

  • Yum, Jong-Kwon;Lee, Yung-Jo;Kim, Jong-Chan;Kim, In-Chul;Kim, Ju-Yong
    • The Korean Journal of Quaternary Research
    • /
    • v.17 no.2
    • /
    • pp.145-148
    • /
    • 2003
  • The Kunang cave paleolithic site is located at Tanyang [$N37^{\circ}2'$, $128^{\circ}21'E$], Chungbuk Province, which is in the Central part of the Korean peninsula. The cave is developed at 312 amsl in a karstic mountainous area. The South Han River flows across this region and other caves can also be found near the river. The site was discovered in 1986 and excavated 3 times by the Chungbuk National University Museum until now. The cave was wellpreserved from modem human activities until the first discovery. The full length of the cave is estimated to be ca. 140 m. However, a spacious part up to 11 m from the entrance has been excavated. Eight lithological units are divided over the vertical profile at a depth of 5 m. Each unit is deposited in ascending order as follow: mud layer (Unit 9), lower complex (Unit 8) which is composed of angular blocks and fragments with a muddy matrix, lower travertine layer (Unit 7; flowstone), middle complex (Unit 6; cultural layer) which is composed of fragments with a muddy matrix, middle travertine layer (Unit 5; flowstone), yellowish muddy layer (Unit 4), upper complex (Unit 3; cultural layer) which has a similar composition to Unit 8. the upper travertine layer (Unit 2; flowstone), and finally surface soil layer (Unit 1). The most abundant vestiges in the cultural layers are the animal bones. They are small fractured pieces and mostly less than 3 cm in length. About 3,800 bone pieces from 25 animal species have been collected so far, 90 percent of them belonging to young deers. Previous archaeological study of these bone pieces shows thatprehistoric people occupied the cavenot for permanent dwelling but for temporary shelter during their seasonal hunting activity. More extensive studies of these bones together with pollen analysis are in progress to reconstruct the paleoenvironment of this cave. Only a single date (12,500 BP) obtained from a U-Th measurement of the upper travertine layer was previously available. In spite of the importance of the cave stratigraphy, there was no detail chronological investigation to establish the depositional process of the cultural layers and to understand the periodic structure of the cave strata, alternating travertine floor and complex layers. We have measured five 14C age dating (38900+/-1000, 36400+/-900, 40600+/-1600, more than 51000 and 52000 14C BP) using Seoul National University 14C AMS facility, conducted systematic process of the collagen extraction from bone fragments samples. From the result, we estimate that sedimentation rate of the cave earth is constant, and that the travertine layers, Unit 2 and Unit 3, was formed during MIS 5a(ca. 80 kBP) and MIS 5c (ca. 100 kBP) respectively. The Kunang Cave site is located at Yochonli of the region of Danyang in the mid-eastern part of Korea. This region is compased of limestones in which many caves were found and the Nam-han river flows meanderingly. The excavations were carried out three times in 1986, 1988, and 1998.

  • PDF

Residual Radioactivity Investigation & Radiological Assessment for Self-disposal of Concrete Waste in Nuclear Fuel Processing Facility (콘크리트 폐기물의 자체처분을 위한 잔류방사능 조사 및 피폭선량평가)

  • Seol, Jeung-Gun;Ryu, Jae-Bong;Cho, Suk-Ju;Yoo, Sung-Hyun;Song, Jung-Ho;Baek, Hoon;Kim, Seong-Hwan;Shin, Jin-Seong;Park, Hyun-Kyoun
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.5 no.2
    • /
    • pp.91-101
    • /
    • 2007
  • In this study, domestic regulatory requirement was investigated for self-disposal of concrete waste from nuclear fuel processing facility. And after self-disposal as landfill or recycling/reuse, the exposure dose was evaluated by RESRAD Ver. 6.3 and RESRAD BUILD Ver.3.3 computing code for radiological assessments of the general public. Derived clearance level by the result of assessments for the exposure dose of the general public is 0.1071Bq/g (3.5% enriched uranium) for landfill and $0.05515Bq/cm^2$ (5% enriched uranium) for recycling/reuse respectively. Also, residual radioactivity of concrete waste after decontamination was investigated in this study. The result of surface activity is $0.01Bq/cm^2\;for\;{\alpha}-emitter$ and the result of radionuclide analysis for taken concrete samples from surface of concrete waste is 0.0297Bq/g for concentration of $^{238}U$, below 2w/o for enrichment of $^{235}U$ and 0.0089Bq/g for artificial contamination of $^{238}U$ respectively. Therefore, radiological hazard of concrete waste by self-disposal as landfill and recycling/reuse is below clearance level to comply with clearance criterion provided for Notice No.2001-30 of the MOST and Korea Atomic Energy Act.

  • PDF

Preliminary Estimation of Earthquake Losses Based on HAZUS in a Coastal Facility Area with Blocks Applying Site Classification (블록별 부지분류 적용 해안시설 영역에서의 HAZUS 기반 지진피해 추정)

  • Sun, Chang-Guk;Chun, Sung-Ho
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.17 no.4
    • /
    • pp.10-27
    • /
    • 2014
  • HAZUS-MH is a GIS-based computer program that estimates potential losses from multi-hazard phenomena: earthquakes, floods and hurricanes. With respect to seismic disaster, characteristics of a hypothetical or actual earthquake are entered into HAZUS. Then HAZUS estimates the intensity of ground shaking and calculates the correspondent losses. In this study, HAZUS was used as a part of the preparations of the future seismic events at a coastal plant facility area. To reliably characterize the target facility area, many geotechnical characteristics data were synthesized from the existing site investigation reports. And the buildings and facilities were sorted by analyzing their material and structural characteristics. In particular, the study area was divided into 17 blocks taking into account the situation of both land development and facility distribution. The ground conditions of blocks were categorized according to the site classification scheme for earthquake-resistant design. Moreover, seismic fragility curves of a main facilities were derived based on the numerical modeling and were incorporated into the database in HAZUS. The results estimated in the study area using HAZUS showed various seismic damage and loss potentials depending on site conditions and structural categories. This case study verified the usefulness of the HAZUS for estimating earthquake losses in coastal facility areas.