• Title/Summary/Keyword: Hazard analysis & critical control point (HACCP)

Search Result 123, Processing Time 0.03 seconds

A study on the food clean room system observing the regulations of HACCP (HACCP의 환경 최적화를 위한 식품 클린룸 설계에 관한 연구)

  • Won, Young-Jae;Suh, Kee-Won
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.520-526
    • /
    • 2009
  • This study proposed the optimum design values for the biological clean room system observing the regulations of Hazard Analysis Critical Control Point (HACCP). Even though the standard for industrial clean room system has been well established, the basis for biological food clean room system is the first stage. In order to prevent the contaminations in advance for food storages, processes, and distributions, the criterion of Hazard Analysis Critical Control Point is positively required. This study also suggested the possible ways of how to avoid the hazardous contaminations.

  • PDF

Microbial Modeling in Quantitative Risk Assessment for the Hazard Analysis and Critical Control Point (HACCP) System: A Review

  • Min, Sea-Cheol;Choi, Young-Jin
    • Food Science and Biotechnology
    • /
    • v.18 no.2
    • /
    • pp.279-293
    • /
    • 2009
  • Quantitative risk assessments are related to implementing hazard analysis and critical control points (HACCP) by its potential involvement in identifying critical control points (CCPs), validating critical limits at a CCP, enabling rational designs of new processes, and products to meet required level of safety, and evaluating processing operations for verification procedures. The quantitative risk assessment is becoming a standard research tool which provides useful predictions and analyses on microbial risks and, thus, a valuable aid in implementing a HACCP system. This paper provides a review of microbial modeling in quantitative risk assessments, which can be applied to HACCP systems.

Development of an Hazard Analysis Critical Control Point (HACCP) Application Model for Dried Anchovy Workplace (마른멸치 작업장의 식품안전관리인증기준(HACCP)모델 개발)

  • YOON, Hyun-Jin;HAM, In-Tae;Kim, Sang-Hyeon;CHOI, Jong-Duck
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.28 no.3
    • /
    • pp.713-726
    • /
    • 2016
  • This study were attempted to apply the HACCP system adopted in the dried anchovy workplace to ensure the hygiene safety of dried anchovy workplace. In this study, HACCP system procedures, including HACCP team organization, determination of critical control point(CCP), establishment of critical limits, mornitering and verification etc., were established using KFDA 12 procedures. To determine whether hazards were critical elements, we evaluated the likelihood and seriousness of each hazard element. The likelihood of residual microorganism and metal piece exceeding the acceptable limit in dried anchovy products were demonstrated to be a critical hazard element. Management of the boiling(CCP-1B) and metal detection(CCP-2P) were determined to be a critical control point. The standards for acceptable residual microorganism and metal piece were set based on relevant laws and regulations, and then the limits were adapted and established for the CCP. An HACCP plan applicable to dried anchovy workplace was established.

The Hazard Analysis and Critical Control Point (HACCP) System and Its Implementation in an Aseptic Thermal Juice Processing Scheme: A Review

  • Min, Sea-Cheol;Min, David B.
    • Food Science and Biotechnology
    • /
    • v.15 no.5
    • /
    • pp.651-663
    • /
    • 2006
  • Hazard Analysis and Critical Control Point (HACCP), a systematic process that identifies, assesses, and controls hazards, has been developed as an effective alternative to conventional end-point analysis for food safety control. The importance of HACCP has been emphasized recently due to the development of new food processing technologies and the increase in international trade demanding worldwide of food product safety. This paper provides a review of HACCP and a generic HACCP template for its implementation for aseptic processing of a juice drink.

Microbiological Hazard Analysis for HACCP System Application to Red Pepper Powder (고춧가루의 HACCP 시스템 적용을 위한 미생물학적 위해 분석)

  • Park, Seong-Bin;Kwon, Sang-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.4
    • /
    • pp.2602-2608
    • /
    • 2015
  • The aim of this research was microbiological hazard analysis which is required to application of HACCP(Hazard Analysis Critical Control Point) system to chili powder. A processing had been conducted in Yong-Geum Agricultural Production located in Dongnyang-myeon, Chungju-si between January 10, 2014 to June 13, 2014. A manufacturing process chart was prepared by entire level of processing. A changes of microorganism was tested by changing sterilization time in ultraviolet ray sterilization processing which can control microbiological Hazard. As a result, critical Limits is decided as ultraviolet rays lamp $20W{\times}12EA$, sterilization $63{\pm}3$ min of each. The result of the microorganism test after ultraviolet ray sterilization was safe. On the other hand, a microorganism test of manufacturing environment and workers suggested that the microbiological hazard should be reduced through systematic cleaning and disinfection accompanied by personal hygiene based on hygiene education on workers.

HACCP의 환경 최적화를 위한 식품 클린룸 설계에 관한 연구

  • Won, Yeong-Jae
    • Air Cleaning Technology
    • /
    • v.23 no.3
    • /
    • pp.1-9
    • /
    • 2010
  • This study proposed the optimum design values for the biological clean room system observing the regulations of Hazard Analysis Critical Control Point (HACCP). Even though the standard for industrial clean room system has been well established, the basis for biological food clean room system is the first stage. In order to prevent the contaminations in advance for food storages, processes, and distributions, the criterion of Hazard Analysis Critical Control Point is positively required. This study also suggested the possible ways of how to avoid the hazardous contaminations.

  • PDF

Risk Assessment and Work in Field for HACCP System Construction of Canned Seasoned Broughton's Ribbed Ark Scapharca broughtonii (피조개(Scapharca broughtonii) 조미 통조림의 HACCP 시스템 구축을 위한 위해평가 및 현장적용)

  • Kang, Young Mi;Cha, Jang Woo;Lee, Su Gwang;Lee, Jae Hyoung;Kim, Jin-Soo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.51 no.5
    • /
    • pp.524-534
    • /
    • 2018
  • This study assessed the biological and physicochemical hazards involved in establishing a hazard analysis critical control point (HACCP) for canned seasoned Broughton's ribbed ark Scapharca broughtonii and examined the critical control points (CCPs) in the field. Following the basic principles of the HACCP system, the hazard-evaluation procedures were enacted during the production of canned seasoned Broughton's ribbed ark after field investigation of a seafood product company in Korea. CCPs were determined using canned seasoned Broughton's ribbed ark with the corresponding control measures. The HACCP system was applied to each step in processing the product. The results indicated that inspection of raw materials, filling, sterilization, and alien substance detection were the most important CCPs. These results can be used to prevent and control food safety problems in the production of canned seasoned Broughton's ribbed ark.

A study on establishment of bio-hazard analysis and critical control point for pork slaughter house (돼지도축장의 생물학적 위해요소에 대한 중요관리점 설정)

  • 옥천석;정지영;송은아;이성식
    • Korean Journal of Veterinary Service
    • /
    • v.24 no.2
    • /
    • pp.117-126
    • /
    • 2001
  • To ensure the safety of domestic livestock products, the government made it obligatory to enforce the hazard analysis critical control point(HACCP) in all domestic slaughterhouses. Under the HACCP, most of the hazards generated in slaughterhouses are bio-hazards, especially pathogenic bacteria. In order to reduce to the pathogenic bacteria, critical control point (CCP) is established and controled in the process of slaughter. A study was carried out to measure the level of bacterial contamination of swine carcass in 6 slaughterhouses selected. As a result, the aerobic plate counts(cfu/$\textrm{cm}^2$) of all samples was $10^2$-10 in average, except slaughterhouse C. The level of the aerobic plate counts on the surface of lower loin in slaughterhouse C was $10^4$ and it was considered that slaughterhouse C should set the process of manual transport of carcass as the CCP. Escherichia coli level was the highest in middle line cut surface. Especially, E coli level of slaughterhouses C and D were about 6.5- and 3.0-fold higher than that of other 4 slaughterhouses. Thus, it was considered that the slaughterhouses C and D should set the process of the entrails treatment as the CCP. The air contamination was measured at two point in a slaughterhouse. The air contamination level was 4-13 times higher than that of the standard Japanese slaughterhouses.

  • PDF

Biological and Chemical Hazards Factor Analysis for CCP(Critical Control Point) in Fried Process of Fried Noodles (유탕면류의 유탕공정 중 중요관리점(CCP)을 위한 미생물학적, 화학적 위해요소분석)

  • Kwon, Sang-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.8
    • /
    • pp.3578-3585
    • /
    • 2012
  • The purpose of this study was to establish the critical limit at CCP (Critical Control Point) of HACCP (Hazard Analysis Critical Control Point) system for instant noodle and it was conducted at P company in Ichen(Gyeonggi-do), Korea. According to the CCP, Fried process were experimented to removal and decrease of microbiological and chemical hazards by measuring of each temperature and times. As a result, the standard plate count and pathogenic microorganism were not detected by fried processing (Temperature : $145{\pm}10^{\circ}C$, Time : $75{\pm}30$ sec). The acid value of chemical hazards produced by fried processing was able to manage, showed lower (0.2) than the legal limit (0.6). Air-borne bacterial examination results detected(3 CFU/mL, 3 CFU/mL) in the Frying Room and Steam Room. Therefore, the CCP-BC of fried process would be a great alternative to prevent and remove hazard analysis, such as general and pathogenic microorganism (E. coli O157:H7, B. cereus, Listeria monocytogenes, Salmonella spp, Sthaph. aureus etc), chemical hazard analysis. In conclusion, it suggested that HACCP plan was necessary for management standard and systematic approach in establishement of critical limit, solving the problem, method of verification, education and records management by fried processing.

The Application of the HACCP System to Korea Rice-cake (떡류의 HACCP 시스템 적용을 위한 미생물학적 위해 분석)

  • Lee, Ung-Soo;Kwon, Sang-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.11
    • /
    • pp.5792-5799
    • /
    • 2013
  • The purpose of this study was the Application of the HACCP (Hazard Analysis Critical Control Point) system to Korean Rice Cakes. Main ingredients of rice cakes, work facilities and workers were provided from KB company located in Seogye-dong Yongsan-gu, Seoul between September 12, 2012 and February 13, 2013. The manufacturing process chart was prepared by referring to the manufacturing process of rice cake manufacturers in general. As a result of this study, the microbiological hazard analysis on raw materials and finished products of rice cakes showed safe result. However, microorganism test on the manufacturing environment and workers suggested that microbiological hazard should be reduced through systematic cleaning and disinfection, accompanied by improved personal hygienes based on hygienic education on workers and management of microorganisms in the air.