• Title/Summary/Keyword: Harmonics simulation

Search Result 507, Processing Time 0.02 seconds

An Active Feedforward Compensation for a Current Harmonics Reduction in Three-phase Grid-connected Inverters (3상 계통 연계형 인버터에서의 전류 고조파 감쇄를 위한 능동형 피드포워드 보상 기법)

  • Park, Byong-Jun;Kim, Rae-Young;Choi, Ki-Young
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.1
    • /
    • pp.1-7
    • /
    • 2014
  • This paper proposes a current harmonic compensation method for the grid-connected inverter, especially caused by the grid impedance. Grid impedance causes low order harmonics in the grid current and deteriorates power quality. This paper analyzes the negative impact of the grid impedance, and proposes an active feedforward compensation method. Proposing method verified through simulation and experiment with 3-phase 1.5kW voltage source inverter prototype.

멀티레벨 전압형 인버터를 사용한 무효전력보상장치

  • Min, Wan-Gi;Kim, Byeong-Cheol;Jeon, Hyeong-Seok;Kim, Hyeong-Gon;Sin, Seok-Du;Jang, Seong-Nam;Lee, Gwang-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1999.07h
    • /
    • pp.21-25
    • /
    • 1999
  • This paper proposes a novel control strategy of SVC(Static var compensator) using cascade multilevel inverter. To control the reactive power instantaneously, the dq-dynamic system model is described and analyzed. A single pulse pattern based on the SHE(Selective Harmonic Elimination) technique is determined from the look-up table to reduce the line current harmonics and a rotating fundamental frequency switching scheme is applied to adjust the DC capacitor voltage at the scheme level. From the simulation, it is verified that this proposed control scheme make the dynamic control response of SVC fast, the current harmonics low, and the DC capacitor voltage balanced.

  • PDF

A Novel Hybrid Islanding Detection Method Using Digital Lock-In Amplifier (디지털 록인 앰프를 이용한 새로운 하이브리드 방식의 단독운전 검출법)

  • Ashraf, Muhammad Noman;Choi, Woojin
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.77-79
    • /
    • 2019
  • Islanding detection is one of the most important issues for the distributed generation (DG) systems connected to the power grid. The conventional passive islanding detection methods inherently have a non-detection zone (NDZ), and active islanding detection methods may deteriorate the power quality of a power system. This paper proposes a novel hybrid islanding detection method based on Digital Lock-In Amplifier with no NDZ by monitoring the harmonics present in the grid. Proposed method detects islanding by passively monitoring the grid voltage harmonics and verify it by injecting small perturbation for only three-line cycles. Unlike FFT for the harmonic extraction, DLA HC have lower computational burden, moreover, DLA can monitor harmonic in real time, whereas, FFT has certain propagation delay. The simulation results are presented to highlight the effectiveness of the proposed technique. In order to prove the performance of the proposed method it is compared with several passive islanding detection methods. The experimental results confirm that the proposed method exhibits outstanding performance as compared to the conventional methods.

  • PDF

Design and Implementation of Instantaneous Power Estimation Algorithm for Unified Power Conditioner

  • S., Sindhu;M.R., Sindhu;Nambiar, T.N.P.
    • Journal of Power Electronics
    • /
    • v.19 no.3
    • /
    • pp.815-826
    • /
    • 2019
  • This paper discusses a simple control approach for a Unified Power Conditioner (UPC) system to achieve power quality compensation at the point of common coupling in distribution systems. The proposed Instantaneous Power Estimation Algorithm (IPEA) for shunt and series active power filters uses a simple mathematical concept that reduces the complexity in the design of the controller. The performance of a UPC is verified with a system subjected to voltage distortions, sags/swells and unbalanced loads using MATLAB/SIMULINK. The simulation study shows that a UPC with the proposed control algorithm can effectively compensate for voltage and current harmonics, unbalance and reactive power. The control algorithm is experimentally implemented using dSPACE DS1104 and its effectiveness has been verified.

Design of Reflector Type Frequency Doubler for Undesired Harmonic Suppression Using Harmonic Load Pull Simulation Technique

  • Jang, Jae-Woong;Kim, Yong-Hoon
    • Journal of electromagnetic engineering and science
    • /
    • v.7 no.4
    • /
    • pp.175-182
    • /
    • 2007
  • In this paper, a study on the reflector type frequency doubler, to suppress the undesired harmonics, is presented. A 12 to 24 GHz reflective frequency doubler is simulated and experimented. Design procedure of the frequency doubler with reflector is provided and the frequency doubler with good spectral purity is fabricated successfully. It has harmonic suppression of the $40{\sim}50\;dBc$ in the $1^{st}$ harmonic and the $50{\sim}60\;dB$ in the $3^{rd}$ harmonic with no additional filter. And, it has conversion gain with the input power of 0 dBm over bandwidth of 500 MHz. A NEC's ne71300(N) GaAs FET is used and the nonlinear model(EEFET3) using IC-CAP program is extracted for harmonic load pull simulation. Good agreement between simulated and measured results has been achieved.

Design of Low Pass Filter to reduce EMI from 2.SG SDH system (2.5G SDH 전자파 감소용 저역통과필터 설계)

  • 이성원;김영범
    • Journal of the Korea Society for Simulation
    • /
    • v.10 no.4
    • /
    • pp.21-30
    • /
    • 2001
  • In this paper, EMI measurement, the STGU simulation being conducted, filter design, its characteristics, and its implementation to the PCB, and finally test results are discussed. When the low pass filter was implemented within the STGU, the power of EMI decreased more than 20dBm. Finally, when TE and MTIE, two important quality measure in synchronous reference clock, was assessed, ITU-T G813 requirement was satisfied. EMI(Electromagnetic Interface) is a measure of electomagnetic radiation from equipment in the range of 10KHz to 3GHz, and can cause unexpected reactions of electronics/electrical equipment. In this study, for safe and stable communication operation, a STGU (System Timing Generation Unit), which is a 2.5G SDH System and a major EMI source, was employed to simulate electromagnetic interface. Using Open-Site test, the power of fundamental frequency of EMI of interest and its harmonics were measured. Also, a low pass filter at cut-off frequency of 2GHz was specifically designed for this study to minimize the effect of EMI between electronic components.

  • PDF

Study on Improving the Phase Noise of Broadband Voltage-Controlled Oscillator

  • Go, Min-Ho;Kim, Hyoung-Joo
    • Journal of electromagnetic engineering and science
    • /
    • v.16 no.3
    • /
    • pp.191-193
    • /
    • 2016
  • This paper proposes a voltage-controlled oscillator (VCO) that has broadband turning and low-level of phase noise characteristics. Due to the micro-strip line resonant circuit with a low Q value, which is applied to the broadband tuning range, the depreciated phase noise performance is compensated by restraining the harmonics of the oscillating frequency. The VCO was designed according to the proposed structure as well as the conventional structure, and the superiority of the proposed structure was verified through its simulation, fabrication, and measurement.

Reconstruction of CIGRE benchmark model for DC Transmission (직류전송을 위한 CIGRE benchmark 모델의 재구성)

  • Wang H.J.;Choi J.H.;Kim C.K.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.446-450
    • /
    • 2003
  • This paper makes more stronger than original model about sending station fault and saves total construction cost to replace established six-pulse bridge by each six thyristor for DC-transmission. Also, varying of controller for sending station has a robust characteristics for harmonics and unbalanced faults. This paper is verified by simulation using EMTDC program. Comparing with the results of original model, this paper is proved superiority.

  • PDF

A New current Controller implemented in a-b-c frame for AC-DC converter (a-b-c frame에서 구현한 AC-DCconverter 전류제어기)

  • 노의철
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.282-285
    • /
    • 2000
  • A new current controller implemented in a-b-c frame for AC-DC converter is proposed. The proposed MTPWM(Modified Trapezoidal PWM) Which is quite suitable for three phase AC-DC converter. It is known that MTPWM has good harmonics characteristics for high modulation index. It is very simple and requires no transformation in it. The results of computer simulation are shown for the validity of proosal.

  • PDF

Deadbeat control of Hybrid Active Power filter using Distrubance-observer (외란관측기를 사용한 복합형능동전력필터의 Deadbeat 제어에 관한 연구)

  • 조광승
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.123-126
    • /
    • 2000
  • When LC filter is connected parallel to the Active Power Filter a problem of the resonance between the Active Power Filter(AF) and LC filte often arises. in this paper Deadbeat control of Hybrid Active Power Filter using Disturbance-observer is introduced to solve this problem. By the estimation of the harmonics disturbance using proposed disturbance observer the compensation characteristics of the AF is improved and the resonant current is suppressed. The validity of proposed disturbance observer is verified from simulation results using PSIM

  • PDF