• 제목/요약/키워드: Harmonics reduction method

검색결과 111건 처리시간 0.03초

DVR시스템에 사용되는 인버터부의 LC필터 설계와 피드백 성능분석 (Design and Feedback Performance Analysis of the Inverter-side LC Filters Used in the DVR System)

  • 박종찬;손진근
    • 전기학회논문지P
    • /
    • 제64권2호
    • /
    • pp.79-84
    • /
    • 2015
  • Voltage sags are considered the dominant disturbances affecting power quality. Dynamic voltage restorers(DVRs) are mainly used to protect sensitive loads from the electrical network voltage disturbances such as sags or swells and could be used to reduce harmonic distortion of ac voltages. The typical DVR topology essentially contains a PWM inverter with LC Filter, an injection transformer connected between the ac voltage line and the sensitive load, and a DC energy storage device. For injecting series voltage, the PWM inverter is used and the passive filter consist of inductor(L) and capacitor(C) for harmonics elimination of the inverter. However there are voltage pulsation responses by the characteristic of the LC passive filter that eliminate the harmonics of the PWM output waveform of the inverter. Therefore, this paper presented design and feedback performance of LC filter used in the DVRs. The voltage control by LC filter should be connected in the line side since this feedback method allows a relatively faster dynamic response, enabling the elimination of voltage notches or spikes in the beginning and in the end of sags and strong load voltage THD reduction. Illustrative examples are also included.

인천국제공항 여객터미널의 고조파분석에 의한 저감대책 강구 (Harmonics Analysis and Reduction of Incheon International Airport)

  • 김용하;이성준;김동근;오석현;김미예
    • 조명전기설비학회논문지
    • /
    • 제19권1호
    • /
    • pp.87-93
    • /
    • 2005
  • 본 논문에서는 측정${\cdot}$분석을 수행한 인천국제공항 여객터미널의 전력계통에 고조파 저감을 위한 고조파필터를 설계하여 이를 적용하였다. 특히 고조파를 다량 발생시키는 기기들에 대하여 향후 대표스펙트럼 선정을 위하여 고조파 측정을 수행하였다. 또한 EDSA를 사용하여 Simulation을 수행하여 수동필터의 고조파 저감효과를 분석하였으며, 또한 APF(Active Power Filter)와 ZSF(Zero Sequence Filter)의 설계를 수행하였다.

영구자석 동기 전동기의 고속운전 시 토크리플 저감 알고리즘 (Torque Ripple Reduction Algorithm of PM Synchronous Motor at High Speed Operation)

  • 김종현;조관열;김학원
    • 전력전자학회논문지
    • /
    • 제20권5호
    • /
    • pp.429-436
    • /
    • 2015
  • Torque ripples generate mechanical vibration at low speed and acoustic noise at high speed. The back emf harmonics of a PM synchronous motor is one of the main sources of torque ripples. To reduce torque ripples resulting from back emf harmonics, dq-axis harmonic currents that reduce the torque ripples are generally compensated to the current controller. Harmonic current compensation is effective at low speed, but it is not applicable at high speed because of the limited bandwidth of the current controller. In this study, dq-axis harmonic voltage compensation that can reduce torque ripples at high speed is proposed. The dq-axis harmonic voltages are calculated from the motor speed and the dq-axis harmonic currents. The effectiveness of the proposed method in reducing torque ripple is verified by a simulation and experiments.

고조파 저감을 위한 직접 주파수 변환기에 대한 연구 (A Study on the Direct Frequency Changer for Harmonics reduction.)

  • 서영수;임영배;김성균;김성기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.1092-1094
    • /
    • 1992
  • Allowing for the fact that the load requiring for high speed has been incrased lately, this paper deals with a method that can consecutively convert the frequency from low frequency to high frequency. And this paper also shows the reduced effect of harmonics and the effectiveness or the proposed system, which are thoughly tested and proved through the experiments in the output frequency range of from 5Hz to 1200Hz.

  • PDF

2중 영 벡터 모드를 갖는 2상 개별 펄스 위치 변조기법 (A Two-Phase Separately Randomized Pulse Position PWM Technique with Double-Zero Vector Mode)

  • 김정근;오승열;정영국;임영철
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권12호
    • /
    • pp.739-750
    • /
    • 2004
  • In case while M(modulation index) is more than 0.7, the spectrum of motor voltage and current of a conventional two-phase SRP-PWM scheme are not reduced considerably. To solve the problems of a conventional two-phase SRP-PWM, this paper proposes a two-phase SRP-PWM(DZSRP-PWM) with double zero vector mode which zero vector is selected as V(111) in case of M >0.7, and zero vector is selected as V(000) if M < 0.7. For the validity of the proposed method, the PSIM simulations and experiments were achieved. And the simulation and experiment results show that the voltage and current harmonics all over the modulation index are spread to a wide band area.

인천국제공항 여객터미널의 고조파 측정 및 분석 (Hormonic Measurement and Analysis of Incheon International Airport)

  • 김용하;최상규;이명민;우성민;이범
    • 조명전기설비학회논문지
    • /
    • 제19권1호
    • /
    • pp.117-123
    • /
    • 2005
  • 본 논문은 허브공항으로의 기능을 담당하고 있는 인천국제공항 여객터미널의 전력품질을 측정하고 분석하여 이에 대한 대책에 관하여 방법을 제시하였다. 각 Load Center는 인천국제공항 여객터미널을 운영하는 수용가의 PCC 점이라 할 수 있다. 그러므로 Load Center의 전력품질을 안전하고 안정적으로 유지하는 것이 중요하다고 할 수 있다. 이를 위해 각각의 위치에 있는 부하 측정지점에서 고조파를 측정${\cdot}$분석하여 대책수립을 위한 Filter의 종류를 제시하였다.

불평형 전원전압을 보상하는 3상3선식 직렬형 능동전력필터에 관한 연구 (A Study of Series Active Power Filter Compensating Unbalanced Source Voltage in 3phase-3wire system)

  • 오재훈;김영석;한윤석;원충연;최세완
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.319-322
    • /
    • 2001
  • In this paper, a 3phase-3wire series active power filter compensating current harmonics and unbalanced source voltages is presented. The system is composed of series active power filter and shunt passive filters that are tuned 5th and 7th harmonics. In this system, series active power filter improves harmonic compensation characteristics of the shunt passive filters and compensates the unbalanced source voltages. In the proposed algorithm, compensation voltage for harmonic reduction is calculated by a performance function, and compensation voltage for the unbalanced source voltage is calculated in based on the synchronous reference frame. Some results obtained from the experimental model using the proposed method are presented to demonstrate and confirm its validity.

  • PDF

고속 버스용 엔진 냉각 팬의 저소음화 연구 (A Study on the Noise Reduction of the Engine cooling Fan used an Express Bus)

  • 오재응;심현진;이정윤
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.279-284
    • /
    • 2002
  • In this study, it has been developed the program for predicting the noise spectrum of axial flow fan. The radiated acoustic pressure is expressed the discrete frequency noise peaks at BPF(Blade passage frequency) and its harmonics by Wu's method and the line spectrum at the broad band by Wright's method. And this paper presents the characteristics of a fan noise due to modify the design parameters. Accordingly, it is obtained the design parameter values for noise reduction of fan.

  • PDF

고조파 주입법에 의한 3상 부스트 정류기의 고조파 저감 (Harmonic Reduction of a Single-Switch Three-Phase Boost Rectifier using Harmonic-Injection Method)

  • 이준구;박석하;김진성;김양모
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부A
    • /
    • pp.134-136
    • /
    • 1998
  • In this paper, we present harmonic reduction of a Single-Switch Three-Phase Boost Rectifier which is operated at 25kHz. A simulation result shows that input current harmonics of Single-Switch Three-Phase Rectifier are reduced by Harmonic-Injection Method. Sixth harmonic is used for Harmonic-Injection Method.

  • PDF

전류주입에 의한 전기추진시스템의 고조파 저감 (Harmonic Reduction of Electric Propulsion System by Current Injection)

  • 김종수;한원희;서동환
    • 해양환경안전학회지
    • /
    • 제18권4호
    • /
    • pp.360-364
    • /
    • 2012
  • 전기추진시스템 분야에서 AC/DC 컨버터는 상대적으로 간단한 다이오드 소자를 이용하는 정류기가 가장 널리 사용되고 있으며 이 정류기는 입력 전류에 큰 고조파를 포함하고 있어서 고조파 저감을 위한 많은 연구가 진행되고 있다. 본 연구에서 제안된 방식은 다이오드 정류기의 출력 전류를 정류기와 추진전동기 입력측에 주입하여 정류기와 추진전동기 입력 전류에 포함되는 고조파 성분을 줄이고 또한, 와이-델타 변압기를 정류기 및 추진전동기 입력회로에 설치되는 전류주입장치의 분배회로에 사용하여 주입전류와 전원 및 부하를 서로 절연함으로써 전류파형 개선과 전기적 안전성을 확보하였다. 제안한 방법을 현재 사용 중인 전기추진선박에서 적용하여 시뮬레이션 하였으며 기존의 전력변환장치와 비교하여 그 타당성을 입증하였다.