• Title/Summary/Keyword: Harmonics level

Search Result 203, Processing Time 0.023 seconds

A Study on the Utility Interactive Photovoltaic System using a Chopper and a PWM Inverter (쵸퍼와 PWM 전압형 인버터를 이용한 계통연계형 태양광발전시스템에 관한 연구)

  • 유택빈;성낙규;이승환;김성남;이훈구;한경희
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.2
    • /
    • pp.131-137
    • /
    • 1998
  • The solar cells should be operated at the maximum power point because its output characteristics are greatly fluctuated on the variation of insolation, temperature and load. Photovoltaic system needs an inverter which can interface the dc output power of solar cell with the residential ac load. The inverter has to supply a sinusoidal current and voltage to the load and the utility line with a high power factor. This paper proposes an utility interactive photovoltaic system designed with a step-up chopper and a PWM voltage source inverter. The step-up chopper operates in continuous mode by adjusting the duty ratio so that the photovoltaic system tracks the maximum power points of solar cell without any influence on the variation of insolation and temperature. The voltage source inverter operates in a manner that its output voltage is in phase with the utility voltage. The inverter supplies an ac power with high factor and low level of harmonics to the load and the utility power system.

Output Filler Design for Noise Reduction of Induction Motor Drive System using H-Bridge 7-Level Inverters (H-Bridge 7레벨 인버터를 이용한 유도전동기 구동시스템의 노이즈 저감을 위한 출력 필터설계)

  • Kim, Soo-Hong;Ahn, Young-Oh;Kim, Yoon-Ho;Bang, Sang-Seok;Kim, Kwang-Seob
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.3
    • /
    • pp.36-44
    • /
    • 2006
  • In general, the generated harmonics and noise of the PWM inverter are affected by PWM switching method, switching frequency, dv/dt and di/dt. Since multilevel inverters are often applied to the high power system, and operates with low switching frequency, theyproduce large size of harmonic contents and noise. Thus it is necessary to install output filters in the multilevel inverter. In this paper a filter design approach for the harmonic and noise reduction the three phase induction motor driving system using H-bridge 7-level inverter system is presented. The passive filter that has low cost and simple structure and can effectively reduce harmonics and noise, is designed and applied to the three phase induction motor drive having multilevel inverter system. The designed system is implemented and verified by simulation and experiments.

Bioacoustic Change of Dybowski's Brown Frog by Highway Noise (고속도로 소음에 의한 북방산개구리의 생물음향학적 특성 변화 연구)

  • Ki, Kyong-Seok;Sung, Chan-Yong
    • Korean Journal of Environment and Ecology
    • /
    • v.28 no.3
    • /
    • pp.273-280
    • /
    • 2014
  • This study examined whether Dybowski's brown frogs(Rana dybowskii) in noisy highway roadsides had different mating calls from those in natural sites. We selected four study sites: two rice paddy sites in Youngdong Highway roadside and two nearby natural counterparts. Frog calls were recorded between 18:30 and 20:00 on February 24, February 27, and March 14, 2014. Frog calls in the natural sites had fundamental frequency approximately at 700 Hz with two to four apparent harmonics, while frog calls in the highway sites had higher fundamental frequency with up to seven apparent harmonics. Analysis of variance (ANOVA) shows that a roadside site that are directly exposed to highway noise had statistically higher frog calling frequency than other study sites. However, the higher calling frequency was not found in another roadside site that differed in elevation from the highway and was buffered by forests. These results indicate that male frogs in a noisy highway roadside called females with a higher pitch and more apparent harmonics to avoid being masked by highway noise. These results also suggest that there is a threshold noise level that interrupts frog's mating behavior and it is needed to maintain highway roadside noise to this threshold level.

Harmonic Current Compensation based on Three-phase Three-level Shunt Active Filter using Fuzzy Logic Current Controller

  • Salim, Chennai;Benchouia, M.T.;Golea, A.
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.5
    • /
    • pp.595-604
    • /
    • 2011
  • A three-phase three-level shunt active filter controlled by fuzzy logic current controller which can compensate current harmonics generated by nonlinear loads is presented. Three-level inverters and fuzzy controllers have been successfully employed in several power electronic applications these past years. To improve the conventional pwm controller performance, a new control scheme based on fuzzy current controller is adopted for three-level (NPC) shunt active filter. The scheme is designed to improve compensation capability of APF by adjusting the current error using a fuzzy rule. The inverter current reference signals required to compensate harmonic currents use the synchronous reference detection method. This technique is easy to implement and achieves good results. To maintain the dc voltage across capacitor constant and reduce inverter losses, a proportional integral voltage controller is used. The simulation of global system control and power circuits is performed using Matlab-Simulink and SimPowerSystem toolbox. The results obtained in transient and steady states under various operating conditions show the effectiveness of the proposed shunt active filter based on fuzzy current controller compared to the conventional scheme.

A PWM Control Strategy for Low-speed Operation of Three-level NPC Inverter based on Bootstrap Gate Drive Circuit (부트스트랩 회로를 적용한 3-레벨 NPC 인버터의 저속 운전을 위한 PWM 스위칭 전략)

  • Jung, Jun-Hyung;Ku, Hyun-Keun;Im, Won-Sang;Kim, Wook;Kim, Jang-Mok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.4
    • /
    • pp.376-382
    • /
    • 2014
  • This paper proposes the pulse width modulation (PWM) control strategy for low-speed operation in the three-level neutral-point-clamped (NPC) inverters based on the bootstrap gate drive circuit. As a purpose of the cost reduction, several papers have paid attention to the bootstrap circuit applied to the three-level NPC inverter. However, the bootstrap gate driver IC cannot generate the gate signal to the IGBT for low-speed operation, because the bootstrap capacitor voltage decreases under the threshold level. For low-speed operation, the dipolar and partial-dipolar modulations can be the effective solution. However, these modulations have drawbacks in terms of the switching loss and THD. Therefore, this paper proposes the PWM control strategy to operate the inverter at low-speed and to minimize the switching loss and harmonics. The experimental results are presented to verify the validity on the proposed method.

3-Phase Transformer Isolated Multi-level Inverter Using Common Arm (공통암을 이용한 3상 변압기 절연 멀티레벨 인버터)

  • Song, Sung-Geun;Park, Sung-Jun;Kim, Dong-Ok;Lim, Young-Cheol;Kim, Kwang-Heon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.2
    • /
    • pp.149-156
    • /
    • 2007
  • The number of transformer and the size of transformer in inverter using 3-phase transformer could be reduced compare with a multi-level inverter using single phase transformer. but still the 3-phase transformer inverter needs many switches. In this study, we proposed the isolated multi-level inverter using 3-phase transformers and common arm, in this paper. Also, using phase angle control method with switching frequency equal to output fundamental frequency, harmonics component of output voltage and switching loss can be reduced. Finally, We tested multi-level inverter to clarify electric circuit md reasonableness through Matlab simulation and experiment by using prototype inverter.

Analysis of Leakage Current Waveforms for Transmission Line Porcelain Insulators due to ESDD Contamination (ESDD 오손에 따른 송전용자기애자의 누설전류 파형의 분석)

  • Park, Jae-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.10
    • /
    • pp.1461-1470
    • /
    • 2012
  • This paper reports the contamination performance of transmission line porcelain insulators tested under five different contaminant conditions - clean and ESDD (equivalent salt deposit density) level (A, B, C, and D) through measurement of their leakage current under drop of potential method. To estimate the contamination for transmission line porcelain insulators, leakage current waveform and its maximum value were measured under step-up power test. In the clean insulators test, % distortion factors decreased with increasing step-up power, and as the ESDD level increased, some characteristics such as frequency analysis, harmonics and % distortion facotor could be used for contamination diagnosis of the transmission line porcelain insulators.

A Study on Staircase PWN Inverter Using Power MOS FET (POWER MOS FET를 사용한 계단파 PWN 인버터에 관한 연구)

  • 이성백;구용회;이종규
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.1 no.2
    • /
    • pp.70-73
    • /
    • 1987
  • This paper itltroduces a simple stair-case PWM using the pseudo-sinusoidal method. In a configuration of controller, the value of sine as a fundamental factor divided into stair-case level and the three-phase PWM inverter is composed by digital compound for each value of stair-case level. The three-phase output pulse at a fixed carrier frequency and a variable reference frequency is obtained under the effect of reduced harmonics. In this experiment, using the power FET as the switching device, 0.5 H.P. induction motor operation is performed when the switching frequency is 20KHz.

  • PDF

Design of Parallel Feedback Dielectric Resonator Oscillator(DRO) for the Suppression of the Harmonic (고조파 억압 특성을 개선한 병렬 궤환형 유전체 공진기 발진기 설계)

  • Ko, Jung-Pil;Lee, Kun-Joon;Kim, Young-Sik
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2003.11a
    • /
    • pp.145-149
    • /
    • 2003
  • The parallel feedback dielectric resonator oscillator (DRO) which is applicable to satellite communications and broadcasting has been investigated. In the design of oscillator, the phase noise is important parameter. In this paper, The proposed oscillator has good phase noise level because it suppressed harmonics. Measurement show the fabricated oscillator is output power of about 9 dBm at fundamental frequency of 12.0 GHz and fundamental frequency suppression of -47.5 dBc. The phase noise level is about -110 dBc/Hz at 100 KHz offset frequency.

  • PDF

A Power Supply System for Lighting of Aerodromes by Using Power Factor Correction and Constant Current Regulator (PFC 및 CCR에 의한 항공조명용 전원공급장치의 개발)

  • Shon, Jin-Geun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.12
    • /
    • pp.2150-2156
    • /
    • 2007
  • According as level of industry develops day after day, electricity load system of industry requires high level control, effectiveness and high efficiency. Among supply and control unit of suitable power supply in these load characteristic, inverter systems of constant current regulate is used widely control of lighting and electric heating system. But, problems that power factor deterioration and fast response of control, efficiency, harmonics and etc are still remain. Therefore, in this paper proposed an inverter systems with constant current regulation and power factor correction (PFC) circuit for lighting and beaconing of aerodromes. The effectiveness of the proposed system confirmed through experimental results of 10[kW] power supply system.