• 제목/요약/키워드: Harmonics level

검색결과 203건 처리시간 0.028초

Harmonic Suppressed Dual-Band Bandpass Filter with Independently Tunable Center Frequencies and Bandwidths

  • Chaudhary, Girdhari;Jeong, Yongchae;Lim, Jongsik
    • Journal of electromagnetic engineering and science
    • /
    • 제13권2호
    • /
    • pp.93-103
    • /
    • 2013
  • This paper presented a novel approach for the design of a tunable dual-band bandpass filter (BPF) with independently tunable passband center frequencies and bandwidths. The newly proposed dual-band filter principally comprised two dual-mode single band filters using common input/output lines. Each single BPF was realized using a varactor-loaded transmission line resonator. To suppress the harmonics over a broad bandwidth, a defected ground structure was used at the input/output feeding lines. From the experimental results, it was found that the proposed filter exhibited the first passband center frequency tunable range from 1.48 to 1.8 GHz with a 3-dB fractional bandwidth (FBW) variation from 5.76% to 8.55%, while the second passband center's frequency tunable range was 2.40 to 2.88 GHz with a 3-dB FBW variation from 8.28% to 12.42%. The measured results of the proposed filters showed a rejection level of 19 dB up to more than 10 times the highest center frequency of the first passband.

Fault-Tolerant Control of Cascaded H-Bridge Converters Using Double Zero-Sequence Voltage Injection and DC Voltage Optimization

  • Ji, Zhendong;Zhao, Jianfeng;Sun, Yichao;Yao, Xiaojun;Zhu, Zean
    • Journal of Power Electronics
    • /
    • 제14권5호
    • /
    • pp.946-956
    • /
    • 2014
  • Cascaded H-Bridge (CHB) converters can be directly connected to medium-voltage grids without using transformers and they possess the advantages of large capacity and low harmonics. They are significant tools for providing grid connections in large-capacity renewable energy systems. However, the reliability of a grid-connected CHB converter can be seriously influenced by the number of power switching devices that exist in the structure. This paper proposes a fault-tolerant control strategy based on double zero-sequence voltage injection and DC voltage optimization to improve the reliability of star-connected CHB converters after one or more power units have been bypassed. By injecting double zero-sequence voltages into each phase cluster, the DC voltages of the healthy units can be rapidly balanced after the faulty units are bypassed. In addition, optimizing the DC voltage increases the number of faulty units that can be tolerated and improves the reliability of the converter. Simulations and experimental results are shown for a seven-level three-phase CHB converter to validate the efficiency and feasibility of this strategy.

Spiral 공진기를 이용한 저위상 잡음 전압 제어 발진기 (Low Phase Noise VCO Using Spiral Resonator)

  • 좌동우;서철헌
    • 대한전자공학회논문지TC
    • /
    • 제45권7호
    • /
    • pp.77-80
    • /
    • 2008
  • 본 논문에서는 위상잡음 특성을 개선하기 위하여 spiral 공진기를 이용한 전압제어 발진기를 제안하였다. Spiral 공진기는 작은 면적, 저지대역에서 날카로운 스커트 특성과 낮은 삽입손실, 큰 결합 계수 값을 가지고 있고, 이로 인해 높은 Q 값을 가지며 전압 제어 발진기의 위상 잡음을 감소시킨다. 공진기의 Q 값이 높아짐에 따라 좁아지는 주파수 조절 범위를 높이기 위하여 버랙터 다이오드를 조절 가능한 부성저항에 연결하였다. 전압 제어발진기는 $5.686{\sim}5.841GHz$에서 발진이 일어났고, 출력은 11.83 dBm, 하모닉 특성은 -29.83 dBc, 위상 잡음 특성은 100 KHz offset에서 $-115.16{\sim}115.17dBc/Hz$이다.

노령화에 따른 건강한 정상 성인의 음향음성학적 특성 비교 (Acoustic Characteristics of Normal Healthy Koreans with Advancing Age)

  • 김선우;김향희;박은숙;최홍식
    • 말소리와 음성과학
    • /
    • 제2권4호
    • /
    • pp.19-28
    • /
    • 2010
  • The purpose of this study was to increase the current understanding of the acoustic characteristics of voices with advancing age. The relationship between age-related changes in body physiology and certain acoustic characteristics of voice was studied in a sample of 80 men representing four chronological age groupings (20-29, 50-59, 60-69, 70-79) who were all of good physical condition. Each subject was asked to phonate the vowel /a/, /i/, and /u/ for as long as possible at comfortable frequency and intensity level and read the sentence. A promising voice analysis program (Multi-Dimensional Voice $Program^{TM}$) was used to measure the fundamental frequency ($f_0$), jitter, shimmer, $f_0$ variation, peak-amplitude variation, smoothed pitch perturbation quotient, smoothed amplitude perturbation quotient, soft phonation index, $f_0$-tremor intensity index, amplitude tremor intensity index, and noise-to-harmonics ratio from the samples.

  • PDF

Modeling of 18-Pulse STATCOM for Power System Applications

  • Singh, Bhim;Saha, R.
    • Journal of Power Electronics
    • /
    • 제7권2호
    • /
    • pp.146-158
    • /
    • 2007
  • A multi-pulse GTO based voltage source converter (VSC) topology together with a fundamental frequency switching mode of gate control is a mature technology being widely used in static synchronous compensators (STATCOMs). The present practice in utility/industry is to employ a high number of pulses in the STATCOM, preferably a 48-pulse along with matching components of magnetics for dynamic reactive power compensation, voltage regulation, etc. in electrical networks. With an increase in the pulse order, need of power electronic devices and inter-facing magnetic apparatus increases multi-fold to achieve a desired operating performance. In this paper, a competitive topology with a fewer number of devices and reduced magnetics is evolved to develop an 18-pulse, 2-level $\pm$ 100MVAR STATCOM in which a GTO-VSC device is operated at fundamental frequency switching gate control. The inter-facing magnetics topology is conceptualized in two stages and with this harmonics distortion in the network is minimized to permissible IEEE-519 standard limits. This compensator is modeled, designed and simulated by a SimPowerSystems tool box in MATLAB platform and is tested for voltage regulation and power factor correction in power systems. The operating characteristics corresponding to steady state and dynamic operating conditions show an acceptable performance.

Increasing the Range of Modulation Indices with the Polarities of Cells and Switching Constraint Reliefs for the Selective Harmonic Elimination Pulse Width Modulation Technique

  • Najjar, Mohammad;Iman-Eini, Hossein;Moeini, Amirhossein
    • Journal of Power Electronics
    • /
    • 제17권4호
    • /
    • pp.933-941
    • /
    • 2017
  • In this paper an improved low frequency selective harmonic elimination-PWM (SHE-PWM) technique for Cascaded H-bridge (CHB) converters is proposed. The proposed method is able to eliminate low order harmonics from the output voltage of the converter for a wide range of modulation indices. To solve SHE-PWM equations, especially for low modulation indices, a modified method is used which employs either the positive or negative voltage polarities of H-bridge cells to increase the freedom degrees of each cell. Freedom degrees of the switching angles are also used to increase the range of available solutions for non-linear SHE equations. The proposed SHE methods can successfully eliminate up to $25^{th}$ harmonic from a 7-level output voltage by using just nine switching transitions or a 150 Hz switching frequency. To confirm the validity of the proposed method, simulation and experimental results have been presented.

DS/CDMA수신기에서 RF변환부의 성능분석 (Performance Analysis of RF Transformation in DS/CDMA Receiver)

  • 편석범;주재한
    • 전자공학회논문지T
    • /
    • 제35T권2호
    • /
    • pp.86-92
    • /
    • 1998
  • 본 논문에서는 DS/CDMA방식을 사용하는 PCS이동국의 표준규격인 J-STD-018에 의한 수신기의 고주파(RF)부 시스템 파라미터를 제시하였고, 수신기의 소자특성에 따른 시스템 성능을 분석하였다. 모의실험 결과 J-STD-018을 만족하는 이동국의 잡음 지수가 10dB인 경우 수신 캐리어로부터 1.25MHz 떨어진 지점에서 선택도는 -70.96dB이며 제 3고조파 차단점은 I 등급 이동국이 -9.5dBm, II~V등급 이동국이 -14dBm이상이었다. 또한 수신기에 입력되는 간섭신호전력이 작을 경우 LNA의 이득이 클수록 성능이 우수하지만, 간섭신호전력이 클 경우 스퓨리어스 영향이 증가하여 성능을 저하시켰다. 따라서 스퓨리어스의 영향을 줄이기 위한 방법으로 LNA의 스위치를 On/Off함으로써 효용성을 입증하였다.

  • PDF

지구 평균 질량 변화를 포함한 GRACE 중력 모델 보정 (Refinement of GRACE Gravity Model Including Earth's Mean Mass Variations)

  • 서기원;엄주영;권병두
    • 한국지구과학회지
    • /
    • 제35권7호
    • /
    • pp.537-542
    • /
    • 2014
  • GRACE는 2002년 발사된 이래로 지하수, 빙하, 해수면의 변동에 의한 지구의 질량 재배치를 관측해오고 있다. GRACE 관측으로부터 추정된 지구 중력 모델은 기압보정을 거쳐 대기 질량이 제거된 지구 표면과 그 하부의 질량 변화를 나타낸다. 그러나 대기 총 질량은 지표면과 대기 사이의 물 교환에 의해 변한다. 그 결과 GRACE 중력 모델은 구면 조화 함수의 계수 degree 0, order 0 ($C_{00}$)에 해당하는 총 대기 질량 변화에 관련된 중력 스펙트럼을 가져야 한다. 주로 계절적인 시간 척도 안에서 변하는 수증기 때문에 $C_{00}$의 변화(${\delta}C_{00}$)는 특히 해수면의 계절적 변동과 북반구와 남반구 사이의 질량 균형에 매우 중요하다. 이 결과는 ${\delta}C_{00}$가 기후변동과 관련된 대륙 규모의 질량 변화 연구에 꼭 고려되어야 함을 뜻한다.

전압원인버터를 이용한 계통연계형 풍력발전의 출력제어 모의 및 해석 (Modeling and Analysis of Control Scheme for Voltage Source Inverter Based Grid-connection of Wind Turbine)

  • 김슬기;김응상
    • 에너지공학
    • /
    • 제12권2호
    • /
    • pp.154-163
    • /
    • 2003
  • 전력계통에 연계하기 위해서 풍력발전시스템은 계속해서 변하는 풍속에 응동하여 적정한 출력을 계통에 공급할 수 있을 뿐만 아니라, 연계되는 전력계통에서 허용될 수 있는 수준의 주파수와 전압크기를 갖는 출력을 제공할 수 있어야 하며, 이를 위해서는 풍력발전의 적절한 출력제어가 필수적으로 요구된다. 본 연구에서는 동기발전기가 전압원인버터로 구성된 AC-DC-AC 변환부를 거쳐 계통에 접속되는 계통연계형 풍력발전시스템의 출력제어 전략을 소개하며, 이를 전자기 과도현상 해석 프로그램인 PSCAD/EMTDC를 이용하여 모의하고 해석하였다. 블레이드를 통해 입력되는 풍속에 대하여 최대 에너지를 공급할 수 있도록 전압원인버터의 유효전력 출력제어가 이루어지며, 출력단 전압을 일정하게 유지하기 위한 무효전력 출력제어가 행해진다. 또한 60 Hz의 주파수 출력 및 고조파 저감을 위해 SPWM 스위칭 방식을 채택하였다. 풍속의 변동 및 부하의 변동에 대한 풍력발전시스템의 응동특성 및 출력변화를 모의하고 해석한다.

ELINT 장비용 광대역 초고속 고정밀 주파수 합성기 설계 및 구현 (Design and Implementation of Wideband Ultra-Fast High Precision Frequency Synthesizer for ELINT Equipment)

  • 이규송;전계익;오승엽
    • 한국전자파학회논문지
    • /
    • 제20권11호
    • /
    • pp.1178-1185
    • /
    • 2009
  • 본 논문은 2.5 MHz 간격으로 광대역 주파수를 발생하며 응답 시간이 400 nsec 이하인 초고속 이산(discrete) 주파수 합성기를 제안한다. 제안한 주파수 합성기는 고정 주파수 위상 제어 루프(PLL)와 주파수 분배기를 이용해 16개의 기준 신호를 생성하고, 이들을 선택하여 주파수 혼합하는 방식으로 710~1,610 MHz내에서 2.5 MHz 간격의 이산 주파수 신호를 고속으로 생성한다. 제작된 주파수 합성기의 주파수 천이 응답 시간은 평균 350 nsec, 고조파를 비롯한 모든 불요파 신호는 -60 dBc 이하, 위상 잡음 특성은 -94 dBc/Hz @100 Hz, 출력 세기는 평균 21.5 dBm, 평탄도는 2.65 dB 이하로 측정되었다. 또한 주파수 천이 응답 속도를 측정하는 새로운 기법의 측정 방법이 제안되었다.