• Title/Summary/Keyword: Harmonics level

Search Result 203, Processing Time 0.024 seconds

A Method to Estimate the Background Level of Harmonics in Distribution Systems (가정, 사무용 기기에 의한 고조파 분포 추정 방법)

  • Kim, Sung-Soo;Kang, Yong-Cheol;Nam, Soon-Ryul;Park, Jong-Keun;Myoung, Sung-Ho
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.5
    • /
    • pp.487-493
    • /
    • 1999
  • To predict the background level of harmonics produced by household appliances, information on the site, capacity, and usage pattern of these loads arenecessary. However, as household appliances are distributed widely and various in type, it is difficult to know these kinds of information accurately. This paper presents a method for estimation of background level of harmonics produced by distributed harmonic sources with readily available data. Large industrial customers are excluded from this study. In this paper, customers are grouped into three classes, i.e. residential, commercial, and industrial. Typical customers for each class are assumed and characteristics of their equipments are modeled. As the proposed method does not require harmonic measurement, it can be employed to forecast voltage total harmonic distribution (VTHD) in the future. An illustrative example is described.

  • PDF

A Survey of the Harmonics Level on a Typical Household Loads by Field Measurements (현장 측정에 의한 일반 가정집 부하의 고조파 수준 조사)

  • Kim, Kyung-Chul;Oh, Kyung-Hoon;Choi, Hyoung-Bumb;Hong, Sa-Guen
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.5
    • /
    • pp.95-102
    • /
    • 2008
  • Typical household loads have nonlinear loads including a personal computer, video, refrigerator, microwave oven, TV, and audio set. These nonlinear loads generate harmonic currents and create distortions on the sinusoidal voltage of the power system. Harmonic field measurements have shown that the harmonic contents of a waveform varies with time. A cumulative probablistic approach is the most commonly used method to solve time varying harmonics. This paper provides in depth analysis on harmonics field measurement of the typical household loads for one year period and the survey is conducted with the objectives to identify the trends of harmonic distortion level present and indentify the future trends of metering in the presence of nonsinusoidal current and voltage waveforms in the system.

Output Voltage Harmonics Analysis of NPC Type Three-level Inverter (NPC형 3레벨 인버터의 출력전압 고조파 분석)

  • Kwon, Kyoung-Min;Choi, Jae-Ho;Chung, Gyo-Bum
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.6
    • /
    • pp.472-480
    • /
    • 2009
  • This paper describes the overmodulative SVPWM technique and harmonics analyses of three phase NPC type three-level inverter to the modulation index. Three phase NPC type three-level inverter adopted SVPWM to extend the linear region to 0.907, moreover, the following voltage compensation using Fourier series was adopted in the region of overmodulation to make it work to six-step level. PD type of multi carrier method is used with the double Fourier series for the analysis of output power harmonics characteristic. Simulation was performed by PSIM, and the harmonics characteristics of 3-level inverter in each region are analyzed. The side band harmonics of carrier frequency are dominant in the linear region, but these harmonic components are decreased as the inveter goes to overmodulation region, and the harmonics due to the fundamental frequency is increased gradually at the same time. The harmonic analyses are verified through the simulation and experimental results under the same condition.

Simplified Control Scheme of Unified Power Quality Conditioner based on Three-phase Three-level (NPC) inverter to Mitigate Current Source Harmonics and Compensate All Voltage Disturbances

  • Salim, Chennai;Toufik, Benchouia Mohamed
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.3
    • /
    • pp.544-558
    • /
    • 2013
  • This paper proposes a simplified and efficient control scheme for Unified Power Quality Conditioner (UPQC) based on three-level (NPC) inverter capable to mitigate source current harmonics and compensate all voltage disturbances perturbations such us, voltage sags, swells, unbalances and harmonics. The UPQC is designed by the integration of series and shunt active filters (AFs) sharing a common dc bus capacitor. The dc voltage is maintained constant using proportional integral voltage controller. The shunt and series AF are designed using a three-phase three-level (NPC) inverter. The synchronous reference frame (SRF) theory is used to get the reference signals for shunt and the power reactive theory (PQ) for a series APFs. The reference signals for the shunt and series APF are derived from the control algorithm and sensed signals are injected in tow controllers to generate switching signals for series and shunt APFs. The performance of proposed UPQC system is evaluated in terms of power factor correction and mitigation of voltage, current harmonics and all voltage disturbances compensation in three-phase, three-wire power system using MATLAB-Simulink software and SimPowerSystem Toolbox. The simulation results demonstrate that the proposed UPQC system can improve the power quality at the common connection point of the non-linear load.

Elimination of Low Order Harmonics in Multilevel Inverters Using Genetic Algorithm

  • Salehi, Reza;Farokhnia, Naeem;Abedi, Mehrdad;Fathi, Seyed Hamid
    • Journal of Power Electronics
    • /
    • v.11 no.2
    • /
    • pp.132-139
    • /
    • 2011
  • The selective harmonic elimination pulse width modulation (SHEPWM) switching strategy has been applied to multilevel inverters to remove low harmonics. Naturally, the related equations do not have feasible solutions for some operating points associated with the modulation index (M). However, with these infeasible points, minimizing instead of eliminating harmonics is performed. Thus, harmful harmonics such as the $5^{th}$ harmonic still remains in the output waveform. Therefore, it is proposed in this paper to ignore solving the equation associated with the highest order harmonics. A reduction in the eliminated harmonics results in an increase in the degrees of freedom. As a result, the lower order harmonics are eliminated in more operating points. A 9-level inverter is chosen as a case study. The genetic algorithm (GA) for optimization purposes is used. Simulation results verify the proposed method.

A study on the measurement of harmonics in the distribution system and the configuration of DB (배전 계통의 고조파 측정 및 DB 구축에 대한 연구)

  • Park, Yong-Up;Kang, Moon-Ho;Jo, Nam-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.202-203
    • /
    • 2006
  • The equipment using the Power electronic device is recently increased in the distribution system, so power utility and customers increase in concerning about harmonics level. Accordingly, The power utility which prepares a measure for the harmonic public standard and manege process must analysis of the harmonics level and the effect on equipment interconnecting distribution system. In the past, the measurement equipment and technique is imperfect, so very difficult to investigate the harmonics and trend. But the improvement of the measurement equipment recently is possible to obtain the data realtime for harmonic analysis. In this paper, we research the measuring domestic harmonic and constructing of DB based on the IEC standard.

  • PDF

Pseudo-Randomized Frequency Carrier Modulation Scheme with Improved Harmonics Spectra Spreading Effects (고조파 스펙트럼 확산효과를 개선한 준 랜덤 주파수 캐리어 변조기법)

  • Kim, Jong-Nam;Jung, Young-Gook;Lim, Young-Cheol
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.12
    • /
    • pp.64-70
    • /
    • 2008
  • In case that conventional PRC(Pseudo-Randomized Frequency Carrier) modulation scheme is applied to a three-phase HBML(H-Bridge Multi-Level Inverter), the dominant harmonics spectra appear at twice switching frequency. In this paper, the dominant harmonics spectra spreading effect of the conventional PRC scheme was improved by using three stage MUXs(Multiplexers) and two triangular carriers with fixed frequency which has mutual relation of the twice frequency. To confirm the validity of the improved PRC scheme, the experiment were performed on a 1.5[kw] three-phase HBML based induction motor drives. And, the harmonics spectra of the conventional and improved PRC schemes are compared and discussed.

Harmonics Analysis of Leakage Current due to Artificial Contamination of Distribution Arresters (배전용 피뢰기의 인공오손에 의한 누설전류의 고조파 분석)

  • Park, Jae-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.9
    • /
    • pp.1306-1313
    • /
    • 2012
  • This paper reports the contamination performance of two distribution arresters (new and used ones) tested under three different contaminant conditions - clean fog, ESDD (equivalent salt deposit density) level (A, B, C, and D), and kaolin contamination conditions, and their leakage current, total leakage current, and component of the resistive leakage current were measured in order to diagnose arrester deterioration. The 3rd harmonics was larger than 5th and 7th ones for the arrester under the clean fog, and as the ESDD contamination level was applied, 5th one became relatively larger than 3rd one. Therefore, these results indicated that the resistive leakage current could be used for the diagnosis of the arresters.

A Case Study of Harmonics in Electrical Installations of Buildings (건축물 전기설비의 고조파에 관한 사례연구)

  • 고희석;김성삼;이현무;김주찬;류희석
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.283-288
    • /
    • 2003
  • This paper presents the result of survey of case study for Harmonics in electrical Installations of buildings. Recently, many power electronic equipments(power converter, computers, air conditioners electronic ballasts for fluorescent lamps and so on) are used in office buildings, and harmonic current from them influence the other equipments in a distribution line. Notably, voltage distortion or voltage harmonics may approach or exceed is allowable level in power distribution system. Individual electric power consumers and end-users and responsible for reducing current harmonics while companies or utilities are responsible for reducing voltage harmonics at the point of common coupling in distribution system. As for harmonics, which one of the electric power qualities, it becomes important to obtain harmonic voltage/current distribution of the power system precisely because the use of power electronic apparatus in increasing. However, there are some difficulties on evaluating the measured data in comparison with the simulated result. The primary cause was indentitied with the resonance of harmonics form many sources. To suppress harmonics in electrical installations of buildings, one of many methods suggest that resonance frequencies are controlled by modulating the capacities of high-voltage customer's capacitors.

  • PDF

EMI Problem and Solutions of Unusual Harmonics in Low-Speed PCB (저속 PCB에서 이상 고조파의 EMI 문제 및 해결 방안)

  • Kim, Chan-Su;Lee, Hai-Young
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.7
    • /
    • pp.636-645
    • /
    • 2015
  • In this paper, unusual harmonics noise problem of digital electronic products in mass production was introduced and a practical solution was proposed. Generally, 5th or higher harmonics noise level has been ignored in circuit designs because over 5th harmonics noise decreases by 40 (dB/decade). Through some measurements, it is confirmed that over 10th harmonics noise can propagate and radiate in case of a certain PCB or housing conditions. We propose a capacitively loaded micro-strip low pass filter for commercial products having spatial design constraints and measured the effectiveness. The proposed structure can solve both of the continual increment of harmonics noise level and the spatial design constraint of commercial products. We expect the proposed method be effectively used for various digital electronic products.