• Title/Summary/Keyword: Harmonic to noise ratio

Search Result 111, Processing Time 0.026 seconds

The Effect of Vocal Function Exercise on Voice Improvement in Patients with Vocal Nodules (성대 기능 훈련이 성대결절 환자의 음성개선에 미치는 효과)

  • Lim, Hye-Jin;Kim, Jeong-Kyu;Kwon, Do-Ha;Park, Jun-Young
    • Phonetics and Speech Sciences
    • /
    • v.1 no.2
    • /
    • pp.37-42
    • /
    • 2009
  • The purpose of the present study was to determine the effect of the management program known as vocal function exercise (VFE) on voice quality. Typical VFE was modified and applied to patients with vocal nodules by controlling intensity of voice and relieving the vocal fold to solve hyperfunctional problems in VFE. Eight female subjects aged between 28 and 54 who had been diagnosed with vocal nodules took part in the study. The patients performed VFEs once a week for eight weeks. Vocal function exercises consist of voice hygiene, respiratory training, phonation training, and glide training. The subjects' voices were analyzed pre and post therapy on the aspects of acoustics, maximum phonation time (MPT), GRBAS, and voice handicap index (VHI). As a result, it was found that fundamental frequency ($F_o$) was significant increased, shimmer decreased remarkably and that noise to harmonic ratio (NHR) lowered obviously in the acoustic parameter. In addition, MPT was increased significantly. The scale of GRBAS indicated significant improvement in grade, roughness, and strained voice. VHI indicated significant improvement in an emotional part. In conclusion, VFE was effective in improving voice quality for patients with vocal nodules.

  • PDF

Modeling of Piano Sound Using Method of Line-Segment Approximation and Curve Fitting (선분 근사법과 곡선의 적합성을 이용한 피아노 음의 모델링)

  • Lim, Hun;Chong, Ui-Pil
    • The Journal of the Acoustical Society of Korea
    • /
    • v.19 no.3
    • /
    • pp.86-91
    • /
    • 2000
  • In this paper, we will discuss the characteristics of the magnitude and the phase of the piano sound in frequency domain by using the FFT(Fast Fourier Transform). The method deciding the parameters representing those sounds through the mathematical model is described. We used the curve fitting method for the modeling of the harmonic part of the sound including the fundamental frequency in order to minimize the errors between original sounds and modeled sounds. furthermore, we used the line segment approximation method for the modeling of the noise part around fundamental frequency. We also applied the same method for the phase model and could get the modeled sound to be similar to the original sound using the parameters. Therefore the high compression ratio comparing the modeled sound to the original sound is achieved.

  • PDF

The Efficiency of Voice Therapy for the Patients with Vocal Nodules (성대 결절 환자를 대상으로 한 음성치료의 효과)

  • 표화영;김명상;최홍식
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.8 no.2
    • /
    • pp.178-184
    • /
    • 1997
  • Vocal nodule due to vocal hyperfunction is one of the representative chronic diseases of vocal folds, and it can be cured by surgical movement, and/or voice therapy. The present study is, focusing on the latter, to compare the acoustic and aerodynamic results of the pretreatment with those of posttreatment, and then to investigate the objective date on the efficiency of the voice therapy for the patients with vocal nodules. 11 females(age : 7-49) and 5 males(age : 8-40), total 16 patients wi vocal nodules treated by voice therapy were participated as subjects. Six measurements and comparisons of pretreatment and posttreatment of the results were performed : litter, shimmer, and noise-to-harmonic ratio as acoustic analyses ; maximum phonation time, mean flow rate, and the subtraction of mean flow rate from maximum flow rate as aerodynamic analyses. As a result, 14 of 16 subjects showed improvement at more than 4 of 6 measurements, and in group data, every measurements of posttreatment was improved significantly than the pretreatment. On the whole, the improvement of aerodynamic aspects was more statistically significant than that of acoustic ones.

  • PDF

Measurements of the Ground Resistance using the Test Current Transition Method in Powered Grounding Systems (측정전류전이법을 이용한 운전중인 접지시스템의 접지저항 측정)

  • Lee, Bok-Hui;Eom, Ju-Hong;Kim, Seong-Won
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.8
    • /
    • pp.347-353
    • /
    • 2002
  • This paper presents an accurate method for measuring the ground resistance in powered grounding system. Most of substations and electric power equipments are interconnected to an extensive grounding network of overhead ground wires, neutral conductors of transmission lines, cable shields, and etc. The parasitic effects due to circulating ground currents and ground potential rise make a significant error in measuring the ground resistance. The test current transition method was proposed to reduce the effects of stray ground currents, ground potential rise and harmonic components in measurements of the ground resistance for powered grounding systems. The instrumental error of the test current transition method is decreased as the ratio of the test current signal to noise(S/N) increases. It was found from the test results that the proposed measuring method of the ground resistance is more accurate than the conventional fall-of-potential method or low-pass filter method, and the measuring error was less than 3[%]when S/N is 10.

Acoustic and Stroboscopic Characteristics in Clergies (목사들의 음성발성에 대한 음향분석학적 특징)

  • 진성민;박상욱;강현국;이경철;이용배;김보형
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.9 no.1
    • /
    • pp.47-52
    • /
    • 1998
  • Objectives : To compare the objective differences in voice quality and voice problems between clergies and normal male control group. Materials and Methods : The sustained vowel sound of 46 clergies and 40 normal persons were analyzed, using a videostroboscopy and acoustic analyzer. Together with these analyses, a questionnaire associated with current and past voice problems was handed over to the patients. Results : The most common symptom in subjective group was the voice fatigue. Stroboscopic findings in subjective group were as following 23 cases(50%) of pachydermia, 17 cases(37%) of phase difference, 12 cases(25%) of anterior-posterior contracture, 6 cases(13%) of vocal polyp and 3 cases(7%) of vocal nodule. The mean maximal phonation time in clergies was 17.8 seconds and in control group was 19 seconds. litter, pitch perturbation quotient and shimmer were significantly increased in subjective group than in control group(p<0.05), but there were no significant differences between two groups in fundamental frequency, vFo, amplitude perturbation quotient and noise to harmonic ratio. Conclusion : In the clergies using loud and forceful voice, vocal polyp and functional voice disorder findings were frequently noted in stroboscopic examination. litter and shimmer, reflecting the roughness of voice, were increased in acoustic analysis. Therefore, clergies, classified into untrained professional voice users, need professional career guidance and counseling.

  • PDF

Joint Relay Selection and Power Allocation for Two-way Relay Channels with Asymmetric Traffic Requirements

  • Lou, Sijia;Yang, Longxiang
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.7 no.8
    • /
    • pp.1955-1971
    • /
    • 2013
  • This paper studies relay selection and power allocation for amplify-and-forward (AF) based two-way relay networks (TWRN) with asymmetric traffic requirements (ATR). A joint relay selection and power allocation algorithm is proposed to decrease the outage probability of TWRN with ATR. In this algorithm, two sources exchange information with the help of the relay during two time slots. We first calculate the optimal power allocation parameters based on instantaneous channel state information (CSI), and then derive a tight lower bound of outage probability. Furthermore, we propose a simplified relay selection criterion, which can be easily calculated as harmonic mean of instantaneous channel gains, according to the outage probability expressions. Simulation results verified the theoretical analyses we presented. It is shown that the outage probability of our algorithm improves 3-4dB comparing with that of other existing algorithms, and the lower bound is tight comparing with actual value for the entire signal-to-noise ratio (SNR) region.

Experimental study on a new damping device for mitigation of structural vibrations under harmonic excitation

  • Alih, Sophia C.;Vafaei, Mohammadreza;Ismail, Nufail;Pabarja, Ali
    • Earthquakes and Structures
    • /
    • v.14 no.6
    • /
    • pp.567-576
    • /
    • 2018
  • This manuscript introduces a new damping device which is composed of a water tank and a pendulum. The new damping device can be tuned to multiple frequencies. In addition, it has a higher energy dissipation capacity when compared with the conventional Tuned Liquid Dampers (TLDs). In order to evaluate the efficiency of this new damping device a series of free vibration and forced vibration tests were conducted on a scaled down single-story one-bay steel frame. Two different configurations were studied for the mass of the pendulum that included a completely and a partially submerged mass. It was observed that the completely submerged configuration led to 44% higher damping ratio when compared with the conventional TLD. In addition, the completely submerged configuration reduced the peak displacement response of the structure 1.6 times more than the conventional TLD. The peak acceleration response of the structure equipped with the new damping device was reduced twice more than the conventional TLD. It was also found that, when the excitation frequency is lower than the resonance frequency, the conventional TLD performs better than the partially submerged configuration of the new damping device.

3-Dimensional Imaging of Shear Wave Velocity in the Soil Site using HWAW Method (HWAW방법을 이용한 지반의 전단파 속도 3-D 영상화)

  • Park, Hyung-Choon;Hwang, Hea-Jin;Cho, Sung-Eun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.176-181
    • /
    • 2010
  • The evaluation of shear modulus (or shear wave velocity) profile of the site is very important in various fields of geotechnical engineering. In the field, there exist spatial variations of shear modulus that case uncertainty in the geotechnical analysis or design. So it is necessary to evaluate the spatial variation of shear wave velocities of the soil site. In this study, the HWAW method is applied to the determination of a 3-D Vs map of soil site. The HWAW method, which is based on harmonic wavelet transforms, has been developed to determine phase and group velocities of waves. The HWAW method uses only the signal portion of the maximum local signal/noise ratio to evaluate the phase velocity in order to minimize the effect of the noise. The field testing of this method is relatively simple and fast because only one experimental setup, which consists of one pair of receivers on the surface, is needed using a short receiver spacing setup (1~3m). These characteristics make it possible to determine detailed local Vs profile in the site with lateral Vs variation and to evaluate 3-D Vs map by performing a series of tests on the grid. To estimate the applicability of the proposed method, field tests were performed. Through field applications validity and applicability of the proposed method were verified.

  • PDF

Objective Measures of Voice Production in Telephone Operators (교환수들의 음성발성에 대한 평가)

  • 진성민
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.8 no.1
    • /
    • pp.38-43
    • /
    • 1997
  • Backgroud : Now a days, most studies for professional voice user have been performed after artificial voice abuse without consideration of environmental and personal factors, and occupational specificity, therefore those studies have some problems. Objectives : To make a basic guideline for the management of untrained professional voice user, practically we ananalyzed the voice of experimental group. Materials and methods : Just after working, the sustained vowel sounds of the 15 female telephone operators (subjective group) and the 20 normal female persons (control group) were analysed, using a history paper, acoustic analyzer and videostroboscopy. Results : The most common symptom in subjective group was dysphonia. Stroboscopic findings in subjective group were as following ; posterior chink 11 cases (73%), incomplete closure 2 cases (13%), anterior chink 1 case (7%). The mean maximal phonation time in telephone operators was 12.8 seconds and in control group was 16.8 seconds. Jitter, pitch pertubation quotient (PPQ), shimmer and amplitude pertubation quotient (ASQ) were significantly increased in subjective group than control group, but there is no difference between two group in fundamental frequency and noise to harmonic ratio. Conclusion : Untrained professional voice user needs professional career guidance and counseling. And when we manage the untrained professional voice user, we should consider specific occupational, personal and environmental factors as well as laryngeal factors.

  • PDF

Low-Power and High-Efficiency Class-D Audio Amplifier Using Composite Interpolation Filter for Digital Modulators

  • Kang, Minchul;Kim, Hyungchul;Gu, Jehyeon;Lim, Wonseob;Ham, Junghyun;Jung, Hearyun;Yang, Youngoo
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.14 no.1
    • /
    • pp.109-116
    • /
    • 2014
  • This paper presents a high-efficiency digital class-D audio amplifier using a composite interpolation filter for portable audio devices. The proposed audio amplifier is composed of an interpolation filter, a delta-sigma modulator, and a class-D output stage. To reduce power consumption, the designed interpolation filter has an optimized composite structure that uses a direct-form symmetric and Lagrange FIR filters. Compared to the filters with homogeneous structures, the hardware cost and complexity are reduced by about half by the optimization. The coefficients of the digital delta-sigma modulator are also optimized for low power consumption. The class-D output stage has gate driver circuits to reduce shoot-through current. The implemented class-D audio amplifier exhibited a high efficiency of 87.8 % with an output power of 57 mW at a load impedance of $16{\Omega}$ and a power supply voltage of 1.8 V. An outstanding signal-to-noise ratio of 90 dB and a total harmonic distortion plus noise of 0.03 % are achieved for a single-tone input signal with a frequency of 1 kHz.