• 제목/요약/키워드: Harmonic simulation

검색결과 976건 처리시간 0.034초

대용량부하의 고조파 발생으로 인한 타수용가 영향 분석 (The harmonic effect analysis about the big capacity load)

  • 박용업;김길신;최원석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.420-421
    • /
    • 2011
  • In generally, the small harmonic current has not influence on the power system because of offset effect. But the bulk harmonic current has not an offset effect, so that influences on the other customer. This paper describes the measurement power quality in the industrial area, and data analysis result. Also this effect has verified by PACAD/EMTDC simulation tool.

  • PDF

부하 특성을 고려한 TCSC 전력송전 시스템의 고조파 해석 (Harmonic Analysis of TCSC Power Transmission System considering Load Characteristics)

  • 정교범
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.468-471
    • /
    • 2000
  • This paper investigates the harmonics of TCSC power transmission system having nonlinear VI characteristic loads. Nonlinear VI characteristic components are modelled with Nortons harmonic current sources. The system parameters such as line impedances admittances and node voltages and the thyristor switching action are described in complex Fourier series. EMTP simulation studies with a detailed three-phase TCSC power transmission system are also performed in order to verify the harmonic analysis at the steady state.

  • PDF

고역률 제어를 위한 단산 전압원 PWM 컨버터에 관한 연구 (A study of Single-phase Voltage Source PWM Converter for High Power Factor)

  • 류성식;손진근;정을기;김형원;전희종
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.362-365
    • /
    • 1999
  • In this paper, the method of reducing harmonics and correcting of power factor in single PWM converter associated with diode rectifier and boos converter is studied. The ac-dc converter in which the harmonic distortion in the input current is reduced using a third harmonic injected PWM is proposed. A lower switching power loss and easy configuration o control circuit are obtained by adopting discontinuous current mode. Simulation and experimental results of ac-dc converter with 5[KHz] switching frequency are presented and correction of power factor and reduction of total harmonic distortion was established.

  • PDF

AM PWM을 이용한 고속 유도 전동기 구동 (High Speed Induction Motor Driving for using AM PWM)

  • 김민태;최재동;김영호;성세진;전칠환
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 전력전자학술대회 논문집
    • /
    • pp.380-383
    • /
    • 1998
  • Amplitude Modulation PWM Technique which has characteristics such as the switching loss and Harmonic distortion reduction is compared in this paper. And also Harmonic components only carrier frequencies. And as it is showed Harmonic components only carrier frequencies via simulation results. Am-pwm is applied to the inverter system of High-speed induction motor.

  • PDF

대출력 Nd:글라스 레이저의 고조파 변환에 관한 연구 (A Study on Higher Harmonic Conversion of High Power Nd:Glass Laser)

  • 강형부;장용무
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 전기.전자공학 학술대회 논문집
    • /
    • pp.397-398
    • /
    • 1988
  • We report on the simulation results of 1)the second harmonic conversion with $1.053{\mu}m$ Nd:glass laser using monolithic KDP crystal and 2)the efficient conversion from $1.053{\mu}m$ to $0.35{\mu}m$ by the polarization-mismatch 3rd harmonic conversion in two Type-II crystals.

  • PDF

배전계통의 VTHD레벨 제시를 위한 최적측정위치 선정 (Optimal Measurement Placement for VTHD level presentation in Distribution Systems)

  • 박희철;조남훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.378-380
    • /
    • 2003
  • This paper presents the optimal point for measuring harmonic levels in distribution systems. Harmonic should be measure PCC (Point of Common Coupling), where is extended over distribution systems, but some PCCs are limited for economical and technical reason : for this reason, the harmonic measurement for a real distribution system and computer simulation are performed to find the optimal PCC in this paper.

  • PDF

6펄스 컨버터를 사용한 대용량 전해조 설비의 고조파 저감기법 (Method of Harmonic Reduction for Large Electrolyzer Facility using 6-Pulse Converter)

  • 민완기;김남오;민병국;조금배;서길모
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.187-190
    • /
    • 2007
  • To improve the power factor and reduce the harmonic contents of the system, the design of tunned filters for six-pulse thyrister converter which is used by electrolyzer system is discussed in this paper. Tunned filters are added to high-power rectifiers to keep the line current distortion within allowable limits and to improve the rectifier power factor. For electrolyzer system, the design procedure of tunned filters of AC 14.4kV power system are proposed by dynamic simulation. It is shown that these harmonic filters can meet most operational requirments. The the proposed design procedure is verified with the simulation and experimental results.

  • PDF

고전압 펄스 발생 장치의 특성에 관한 시뮬레이션 연구 (Simulation Study of Characteristics for Device of the High Voltage Pulse Generator)

  • 김영주;신주희
    • 조명전기설비학회논문지
    • /
    • 제26권12호
    • /
    • pp.80-86
    • /
    • 2012
  • The high-voltage pulse generator is consist of transformers of fundamental wave and harmonic waves, and shunt capacitances. The pulse has the fundamental wave and the harmonic waves that have been increased as a series circuit by the transformers to make high voltage pulse. This paper shows the high-voltage pulse generator simulation using a circuit program with experiment data. In the equivalent circuit, magnetized inductances and loss resistances which affect output voltage, have been obtained. The output capacitor circuits have characteristics of band pass. The output voltages of the pulse width 50% and 25%(PWM) were obtained. The output of the high-voltage pulse generator is 2.5kHz, 1.8kV.

차량 추진축과 엑슬 진동의 상관성에 관한 연구 (A Study on the Correlation of Vehicle Propeller Shaft and Axle Vibration)

  • 장일도;한기석;홍동표
    • 소음진동
    • /
    • 제10권4호
    • /
    • pp.596-601
    • /
    • 2000
  • Propeller shaft is one of the main excitation source in the vehicle driveline. This paper presents the correlation of the propeller shaft and axle vibration. 10 D.O.F. lumped mass model is constructed to simulate the dirveline. Experimental apparatus is constructed to verify the simulation model and to measure the vibration signal of lthe driveline. The results of simulation and experiments show that propeller shaft excitation is 2nd harmonic of the rotational frequency. Axle housing vibration signal shows that axle resonate with 2nd harmonic of excitation frequency due to universal joint effect.

  • PDF

특정 고조파 제거를 위한 Cascaded H-bridge 7레벨 인버터의 특성해석 및 시뮬레이션 (Analysis and simulation of Cascaded H-bridge 7 level inverter for eliminating typical harmonic waveforms)

  • 진선호;오진석;조관준;곽준호;임명규;김장목
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 전기학술대회논문집
    • /
    • pp.1022-1028
    • /
    • 2005
  • This paper is presented the analysis results and simulation results of cascaded H-bridge 7 level inverter with various modulation index. Stepped waveform having number of switching was used to eliminate harmonic components. Switching angles according to modulation index are calculated numerically. Therefore, 3 times of switching with 7 level topology and QWS(Quarter Wave Symmetry) could eliminate 5th and 7th harmonics. The harmonic characteristics are compared to those of space vector modulation method which known as common modulation method in industrial field. Stepped waveform method showed higher ability to reduce, especially lower order of harmonics.

  • PDF