• Title/Summary/Keyword: Harmonic operation

Search Result 396, Processing Time 0.032 seconds

The Stack Design Considering The Reactive Power Supply of Grid-Connected Inverter (계통 연계형 인버터의 무효전력 공급을 고려한 Stack 설계)

  • Koh, Kwang-Soo;Oh, Pil-Kyoung;Kim, Hee-Jung;Kim, Young-Min
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.453-454
    • /
    • 2016
  • The ESS(Energy Storage System) connected with distributed generation is drawing attention due to improving the quality load leveling, peak shaving for enhancing reliability of the power grid. The grid-connected inverter makes frequency adjustment to the active power's charge discharge according to the load variation. In addition, the inverter is possible to act as a reactive power compensation device to eliminate harmonic operates as power factor change inhibiting, anti-transient voltage fluctuation, active filter. In this paper, we propose a design method of igbt stack considering the reactive power supply capacity to improve the quality and reliability of the inverter. Moreover, the grid-connected inverter considering the four-quadrant rated operation designed stack and verified the feasibility of the design through a thermal analysis.

  • PDF

Analysis of Input Characteristic in the Rectifier for Output Filter with Unbalanced Supply Voltages (불평형 전원전압을 갖는 정류시스템에서 출력필터에 따른 입력 특성 분석)

  • Kang, Su-Heon;Kim, Sang-Hoon
    • Journal of Industrial Technology
    • /
    • v.25 no.B
    • /
    • pp.195-202
    • /
    • 2005
  • The rectifier characteristics and the quality of the input current worsens with the increase of unbalances or harmonics of the supply voltages. Rectifier input current harmonics interfere with proper power system operation, reduce rectifier power factor, and limit the power available from a given source. It is of importance to select appropriately the rectifier's output filter inductance to determine the rectifier input current waveform, the input current harmonics, and the power factor. This paper presents a quantitative analysis of single and three phase rectifier input current harmonics, total harmonic distortion, and power factor as a function of the output filter inductance under balanced and unbalanced conditions. Also, its performance under the supply voltage including harmonics be investigated. These results provide a reference for selecting reasonable rectifier's output filter inductance for given harmonics or power factor criterion.

  • PDF

Shape Optimal Design to Minimize Dynamic Twisting Deformation of the Door Frame of a Microwave Oven (전자레인지 도어 프레임의 동적 비틀림 변형 최소화를 위한 형상 최적설계)

  • Lee, Boo-Youn;Koo, Jin-Young;Kim, Won-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.11 s.254
    • /
    • pp.1479-1485
    • /
    • 2006
  • To minimize the leakage of microwave which can occur when one pulls the door of a microwave oven during its operation, shape optimization of the door frame is presented. A numerical optimization is implemented to minimize the dynamic twisting deformation of the door frame. Shape design variables are defined, which represent the dimension of the bead in the flange. Two optimal design problems are established to minimize the maximum twisting deformation from harmonic response analysis. The problems are solved, their results being compared and evaluated.

Sag-Swell Generator for Power Quality Disturbance of Dynamic UPS System (전력품질을 고려한 다이나믹 UPS 시스템의 Sag-Swell 발생기)

  • Ahn J.S.;Choi K.J.;Chun T.W.;Nho E.C;Kim I.D.;Kim H.G.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.193-196
    • /
    • 2003
  • This paper describes a new Sag-Swell generator for the test of custom power devices such as UPS, DYR, DSTATCOM, 5575, etc. The proposed science has good features of simple structure, high reliability, wide range of Sag and Swell variation, and easy control. Outage, harmonic distortion, notches, and voltage unbalance also can be generated. The operation principle of the proposed scheme is described and verified through simulations.

  • PDF

A Study on the Behaviour of Nonlinear Dynamic Absorber (비선형 동흡진기의 동적 거동에 관한 연구)

  • 박철희;송석홍;신현재;홍성철
    • Journal of KSNVE
    • /
    • v.3 no.2
    • /
    • pp.137-143
    • /
    • 1993
  • The conventional dynamic vibration absorber is very efficient in inhibiting the vibration of a machine. This is accomplished by "tuning" the absorber to the frequency of the harmonic disturbing force. If, however, the frequency of the disturbing force varies over a tuning frequency range in the normal operation of the system, the linear dynamic absorber may become inoperative and might aggravate matters particularly. This study is to endow the dynamic absorber with greater flexibility in suppressing vibrations throught a range of frequencies of the disturbing force. By introducing springs with nonlinear characteristics into its design, the results can be obtained. In this paper, the machine and the absorber were modelled as a nonlinear two-degree-of freedom system. And the concepts of nonlinear normal mode were adopted to obtain this purpose.s purpose.

  • PDF

A Study on the Load Commutated Current Source Inverter assisted with A GTO-DC Source Forced Commutation (GTO-직류전원을 병용한 부하전류(轉流)식 전류형 인버터에 관한 연구)

  • Mok, Hyung-Soo;Sul, Seung-Ki
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.591-595
    • /
    • 1991
  • The load commutated current source inverter(LCCSI) with GTO-DC source forced commutation is described in this Paper. GTO-DC source forced commutation assures the stability of commutation below critical frequency determined by output capcaitor and it also gives the oppotunity of PWM operation for reducing resonant harmonic components. he simulation results clearly show hat the proposed commutation circuit works well in the resonance phenomenon between output capacitor and machine leakage inductance.

  • PDF

Three-Phase Current-Fed Active Power Filter Operating Characteristics by Optimized Injection Method (최적주입방식에 의한 3상 전류형 능동필터의 운전특성)

  • Park, Su-Young;Kim, Ho-Jin;Lee, Jung-Min;Hwang, Jung-Ho;Choe, Gyu-Ha
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.451-455
    • /
    • 1991
  • The PWM control technique is proposed which can eliminate the harmonic components of the nonsinusoidal ac line current such as the current of 6-phase rectifier by injecting PWM current. TSC(Time-Sharing Control) is adopted to avoid the unbalance between three PWM injection currents at the three-phase system. Also a new power circuit for three-phase filter is suggested for realizing the proposed PWM control technique. The operation characteristics are investigated theoretically and experimentally to show the feasibility of the optimized injection method.

  • PDF

Analysis and design DC-DC converter for solar cell array output control (태양전지 출력제어를 위한 DC-DC 컨버터의 해석 및 설계)

  • 고재석
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.665-669
    • /
    • 2000
  • Recently the problem of energy branch become worse increasingly. Therefore many researches about new energy source are processing in several places around are processing in several places around the world. Especially solar energy has many advantages like as purity and infinity. Photovoltaic(PV) system can be classified into two types : One is stand alone type and the other is utility interactive one. Utility interactive type PV system need some technology that Maximum peak power tracking(MPPT) and Anti-islanding and Active Power filter(APF). For APF operation dc-link voltage should be high to supply sufficient output current which needed for harmonic current compensation so usually DC-DC converter is used for boost. In this paper DC-DC converter for PV system and controller for dc-link voltage control are analyzed and designed.

  • PDF

A Parallel Processing Uninterruptible Power Supply for Sudden Voltage Fluctuation for Computer Applications

  • Lee, Su-Won;Ko, Sung-Hun;Lee, Seong-Ryong;Jung, Yong-Chae;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2009.11a
    • /
    • pp.287-289
    • /
    • 2009
  • This paper deals with a parallel processing uninterruptible power supply (UPS) for sudden voltage fluctuation in computer applications to integrate power quality improvement, load voltage stabilization and UPS. To reduce the complexity, cost and number of power conversions, which results in higher efficiency, only one voltage-controlled voltage source inverter (VCVSI) is used. The system provides sinusoidal voltage at the fundamental value of 220V/60Hz for the load during abnormal utility power conditions or grid failure. Also, the system can be operated to mitigate the harmonic current and voltage demand from nonlinear loads and provide voltage stabilization for loads when sudden voltage fluctuation occur, such as sag and swell. System operation simulation demonstrates that the system protects against outages caused by abnormal utility power conditions and sudden voltage fluctuations and changes.

  • PDF

Characterization and Performance Evaluation of Advanced Aircraft Electric Power Systems

  • Eid, Ahmad;El-Kishky, Hassan;Abdel-Salam, Mazen;El-Mohandes, Mohamed T.
    • Journal of Power Electronics
    • /
    • v.10 no.5
    • /
    • pp.563-571
    • /
    • 2010
  • A model of an advanced aircraft electric power system is developed and studied under variable-speed constant-frequency (VSCF) operation. The frequency of the generator's output voltage is varied from 400-Hz to 800-Hz for different loading scenarios. Power conversions are obtained using 12-pulse power converters. To reduce the harmonic contents of the generator output waveforms, two high-pass passive filters are designed and installed one at a time at the generator terminals. The performance of the two passive filters is compared according to their losses and effectiveness. The power quality characteristics of the studied VSCF aircraft electric power system are presented and the effectiveness of the proposed filter is demonstrated through compliance with the newly published aircraft electrical standards MIL-STD-704F.