• Title/Summary/Keyword: Harmonic operation

Search Result 396, Processing Time 0.023 seconds

Effect on Molded Case Circuit Breaker of Harmonic Current (고조파 전류가 배선용차단기에 미치는 영향)

  • Yoo, Jae-Geun;Choi, Myung-Il;Park, Chee-Hyun;Son, Jae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.1
    • /
    • pp.53-58
    • /
    • 2008
  • This paper analyze the operating characteristic of MCCB due to the synthesize harmonic current. Four types of MCCBs, divided by the type of operation system and a principle of operation, tested with 200[%] of rated current. The test result nuisance tripping did not occur but the time delay characteristic of the hydraulic magnetic type MCCB is appeared. From the place where the synthesize harmonic content is high it is good the hydraulic magnetic type MCCB not to use.

A Study on the Harmonics Reduction using Phase Shifting Transformer in a Electric Power Distribution System (배전계통에서 위상조정 변압기를 사용한 고조파 저감에 관한 연구)

  • 김경철
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.2
    • /
    • pp.38-44
    • /
    • 2002
  • The increasing use of non-linear loads such as power electronics draw highly distorted currents from the utility system High harmonics current, and voltages will cause equipment damage and disturb the plant operation. The application of phase shifting transformers can be a very cost-effective method of harmonic treatment where multiple harmonic sources ice in operation. In this paper simulation results used the EDSA harmonics analysis program verifying the effects of a phase shifting transformer for harmonic elimination are presented.

Harmonic Current Compensation Method Using Inverter-Interfaced Distributed Generators (인버터 연계형 분산전원을 이용한 배전계통 고조파 전류 보상원리)

  • Chung, Il-Yop;Kang, Hyun-Koo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.2
    • /
    • pp.279-284
    • /
    • 2011
  • Harmonic distortions in current waveform may cause significant problems in electric power system facility and operation. This paper presents an adaptive parameter estimation method to detect harmonic current components caused by nonlinear loads. In addition, a coordination strategy for multiple inverter-interfaced distributed generators to compensate the harmonic currents is discussed. The coordination strategy is realized by distributing the harmonic compensation participation index to individual distributed generators. The harmonic compensation participation index can be determined by the amount of remaining power generation capacity of each distributed generator. Simulation results based on switching-level inverter models show that the proposed harmonic detection method has good performance and the coordination strategy can improve harmonic problems efficiently.

A Study on Harmonic Reduction of Single-phase UPS with Variable Passive Harmonic Filters (가변형 수동 고조파 필터에 의한 단상 무정전전원장치의 고조파 저감에 관한 연구)

  • Kim, Sung-Sam;Hwang, Seon-Hwan
    • Journal of IKEEE
    • /
    • v.23 no.2
    • /
    • pp.495-501
    • /
    • 2019
  • This paper proposes a variable passive harmonic filter for reduction and improvement of harmonics and power factor of single-phase uninterruptible power supply(UPS) with full bridge rectifier. Recently, UPSs have excellent harmonic and power factor operation characteristics by applying 2-level or more levels of power conversion methods. On the other hand, the single-phase UPS of the full bridge rectifier seriously causes the third, fifth, and seventh harmonics, and the power factor reduction on the grid side. Therefore, we present a variable passive harmonic filter for eliminating (2n+1) order harmonics and improving the power factor generated by the full bridge rectifier operation. In order to evaluate the performance of the proposed variable harmonic filter, the its validity is verified by various simulations and experiments.

Steady-State Harmonic Domain Matrix-Based Modeling of Four-Quadrant EMU Line Converter

  • Wang, Hui;Wu, Mingli;Agelidis, Vassilios G.;Song, Kejian
    • Journal of Power Electronics
    • /
    • v.14 no.3
    • /
    • pp.572-579
    • /
    • 2014
  • As a non-linear time variant system, the four-quadrant line converter of an electric multiple unit (EMU) was expressed by linear time periodic functions near an operating point and modeled by a steady-state harmonic domain matrix. The components were then combined according to the circuit connection and relations of the feedback control loops to form a complete converter model. The proposed modeling method allows the study of the amplitude of harmonic impedances to explore harmonic coupling. Moreover, the proposed method helps provide a better design for the converter controllers, as well as solves the problem in coordination operation between the EMUs and the AC supply. On-site data from an actual $CRH_2$ high-speed train were used to validate the modeling principles presented in the paper.

A Study on Harmonic Analysis and Evaluation According to Operating Mode During Operation of the Tilting Train Express (한국형 틸팅열차 운행 중 운전 모드에 따른 고조파 분석 및 평가에 관한 연구)

  • Kang, Chul;Lim, Jae-Chan;Huh, Jae-Sun;Kim, Jae-Chul;Lee, Su-Gil;Han, Soung-Ho
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.416-421
    • /
    • 2009
  • Recently, the new Korean Tilting Train Express(TTX) which maintains a speed on the curve railway line is developed. Electric railways, including the TTX, have electrical problems that could bring about serious accidents. For such reasons, the electric railway's electrical problems, electrical harmonic and others, have been studied briskly. Thus, TTX's electrical problems also need leading studies because the new Korean TTX will operate earnestly in 2012. The results could be used hereafter diagnosis of it's components and train conditions. In the paper, electrical signals in TTX operation were measured to analyze electrical harmonic. In addition, after the electrical signals were measured to operating mode (coasting mode, acceleration mode and regenerative breaking mode) respectively in test section(Ho-nam line, Chung-buk line, Jung-ang line and Tae-baek line). The electrical harmonics considered operating modes triparted were analysed and evaluated.

Harmonic Suppression of the Input Current in Microwave Oven Using LLC Resonant Inverter (전자레인지용 LLC 공진형 인버터의 입력전류 고조파 억제)

  • Kang, Kyelyong;Kim, Heung-Geun;Cha, Honnyong
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.3
    • /
    • pp.225-230
    • /
    • 2018
  • This paper proposes a parametric design of an LLC resonant inverter used for a microwave oven. To improve the harmonic performance of the microwave oven, a current controller with a variable PI gain is proposed. Due to the recent strengthening of harmonics regulations, inverter control technology for microwave ovens is now required to satisfy harmonic performance. In an LLC resonant inverter, the voltage gain varies remarkably depending on the magnetron voltage, output power, and input voltage. To satisfy harmonic performance, a controller that can maintain operation in the zero-voltage switching (ZVS) region and control changes in voltage gain is required. The modified design of the LLC resonant inverter ensures ZVS operation even when the magnetron is heated. Application of the variable current controller improves harmonic control according to the instantaneous gain curve change. The validity of the proposed power control with a variable current controller is verified by experiments with a 1200 W microwave oven.

Estimation of Harmonics on Power System of AC Electric Railway (교류 전기철도 전력계통의 고조파 예측량 계산)

  • 송진호;황유모
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.2
    • /
    • pp.68-79
    • /
    • 2003
  • We estimated harmonics on power system of AC railway based on quantitatively measured harmonics and investigated the need of facilities for harmonics reduction. In order to analysis harmonics which inflow into power system due to increase in collector voltages and harmonic currents generated from the train when the railway is in operation, the railway system Is sectioned into power supply, railway line, AT, sectioning Post and subsectioning post. For analysis of extension of currents resulting from the railway loads, PWM converter, VVVF inverter and the feeder system are modeled based on the dynamic node technique(DNT). In order to test the usefulness of the DNT for analysis of harmonic effects, the measured harmonic currents and harmonic magnification ratios at the S/K substation are compared with simulation results using DNT modelling, which include the results for two cases with and without filters for suppression of harmonic currents. When 8 cars(4M4T) are in operation, the total sum of harmonic currents resulting from the train at M and T phases, which inflow into the substation along with the railway line, is calculated. Using the harmonics analysis program for railway feeder system with these data, the total harmonic distortion factor(710) at the outgoing point of KEPCO substation is computed. The calculation shows that when the maximum THD at the receiving point of H/K substation was 0.0443% which is much lower than 1.5% which is the allowable value of KEPCO at 154kV as well as IEEE-519 above 132kV This result indicates that any measure for harmonics reduction in Incheon International Airport Railway is not needed.

Parallel Operation of Space Vector PWM Inverters for Large Capacity Inverter System (대용량 인버터 시스템을 위한 공간벡터 PWM 인버터의 병렬 운전)

  • Ji, Jun-Geun;Lee, Hyeon-Dong
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.8
    • /
    • pp.509-513
    • /
    • 2000
  • This paper deals with the parallel operation of space vector PWM for large capacity inverter system. To enlarge the capacity of inverter system and to reduce the current ripples on inverter output side, two or more inverters are operated in parallel. In this paper, a new parallel operation strategy which minimizes the harmonic distortion of the output stage is described. The proposed method is developed on the basis of the space-vector PWM in order to increase the linearly controllable voltage range. With the help of the proposed voltage synthesis method, the total harmonic distortion of the output stage can be greatly reduced in compared with that of conventional method with sinusoidal PWM or that of the single inverter operation case. The experimental results with reduced scale test show the feasibility of the proposed voltage synthesis method.

  • PDF

Analysis of Output Characteristics for the Resonant DC Link Inverter Using PWM Inverter Modulation Methods (인버터 PWM 방식을 이용한 공진형 직류 링크 인버터의 출력 특성 해석)

  • 김윤호;윤병도;이병순
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.41 no.6
    • /
    • pp.615-624
    • /
    • 1992
  • For the operation of the resonant DC link inverters, only limited number of modulation techniques such as the delta modulation and instantaneous current control techniques have been suggested. However, these modulation techniques have some limitations in practical operation. In this paper, the application of conventional inverter modulation techniques is suggested for the control of the resonant DC link inverter. The harmonic analysis results are presented. The results show that these modulation techniques offer good output characteristics similar to conventional inverter PWM techniques for the operation of the resonant DC link inverter. This implies that not only the delta modulation technique and instantaneous current control techniques but also various other modulation techniques can be applied to the operation of the resonant DC link inverter. This also indicates that open loop control as well as closed loop control can be used for the operation of the resonant inverter. The resonant DC link inverter with various modulation strategies is implemented using V-40 microprocessors.

  • PDF