• 제목/요약/키워드: Harmonic measurements

검색결과 127건 처리시간 0.06초

소음계 교정 자동화 시스템 개발 및 성능평가 (Development and Performance of Automated Calibration System of Sound Level Meters)

  • 김용태;조문재;이용봉;서재갑
    • 소음진동
    • /
    • 제8권5호
    • /
    • pp.879-886
    • /
    • 1998
  • An automated calibration system of sound level meters was developed and tested. As a standard sound source, the speaker unit(Forstex FE208) cabineted by 440$\times$390$\times$490 $\textrm{mm}^3$(LHW) volume wood box was adopted. Including this source, the driving part was found out to have a good linearity of sound pressure output vs AC voltage input. The Hybrid-Bisect/Newton-Raphson method modified by the linearity was adopted as a searching algorithm. Uisng GPIB interface, the console PC make the control, measurements, and calculations and finally make the accumulation of useful data and results automatically by the instructon in the program coded by C languate. Several trials of automatic calibration using this developed system give the reliable results.

  • PDF

Poling된 실리카 유리의 2차비선형광학효과와 공간전하분극의 관계 (Induced Second Order Optical Nonlinearity in Thermally Poled Silica Glasses)

  • 신동욱
    • 한국세라믹학회지
    • /
    • 제36권12호
    • /
    • pp.1374-1380
    • /
    • 1999
  • The cause of Scond Harmonic Generation (SHG) in thermally poled silica glass is suggested basedon the electrical and dielectric relaxation measurements. The absorption currents as functions of time were measured for various types of silica glasses and analyzed by the theory of Space Charge Polarization. Space charge polarization occurs when an ionic conducting material is subjected to dc electric field with blocking electrode. Thermal poling performed to induce SHG in silica glass is basically identical to the process generating space charge polarization. Hence it was found that gene-ration removal reproduction and temperature dependence of SHG in poled silica is directly related to those of space charge polarization. It turned out that the fundamental parameters governing the SHG in poled silica are charge carrier concentration and mobility. Based on the theory of space charge polarization and experimental results of electrical rela-xation the method to increase the intensity of SHG is proposed.

  • PDF

강유전성 고분자 P(VDF-TrFE)(72/28 mole%)의 파장 1064 및 532 nm에 대한 2차 비선형 광학 계수 측정 (Measurements of the Second Harmonic Coefficients of the Ferroelectric Polymer P(VDP-TrFE)(72/28 mole%) at 1064 and 532 nm Wavelength)

  • 정창수;임종선;박광서;김도석;이범구
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2001년도 제12회 정기총회 및 01년도 동계학술발표회
    • /
    • pp.232-233
    • /
    • 2001
  • 2차 비선형광학 물질이 높은 응용성을 갖기 위해서는 큰 2차 비선형광학 계수뿐만 아니라 넓은 파장 영역에 걸친 투명성을 가지고 있어야 한다. vinylidene fluoride(VDF)와 trifluoroethylene(TrFE)가 공중합된 f(VDf-TrFE) 공중합체는 이러한 조건을 갖추고 있는 강유전성 물질이다. 우리는 몰비율이 72:28인 P(VDF-TrFE)을 ITO기판위에 casting하고 corona 극화한 뒤, 두 개의 입력 파장(1064nm, 532nm)에 대한 2차 조화파 발생 실험을 실시하고 Herman과 Hayden의 마커무의 식을 이용하여 2차 비선형 광학 계수를 측정하였다. (중략)

  • PDF

만내의 해수유동에 관한 실험적 연구 (An Experimental Study on the Sea Water Flow in Bay)

  • 김미금;김창제
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2002년도 춘계학술대회논문집
    • /
    • pp.205-218
    • /
    • 2002
  • Recently, the water pollution of coastal sea area including harbor, bay and inland sea has been very serious and it causes various environmental impacts. In this study, water flow system of Danghang Bay, which has the narrow and long topographical characteristics with the narrow bay mouth and its flow is influenced principally by the tidal current, is investigated experimentally and numerically. In order to understand the tidal system of Danghang Bay, harmonic analysis is performed based on measured tidal range and flow velocity In addition, numerical model for tidal exchange is developed considering conditions of Danghang Ray. Calculated results show good agreement with measurements. Lastly. based on the proposed numerical model, exchange ratio of seawater volume in Danghang Bay is predicted.

  • PDF

EMTDC를 이용한 DSTATCON 설치 효과 분석 (Analysis of System Performance on DSTATCON Installation using EMTDC)

  • 유일도;최영준;홍순옥;이학성;전영수;이기선
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.943-945
    • /
    • 1998
  • This paper presents a method of modeling of DSTATCON (Distribution-line Static Condenser) for installation in a specific plant and analyze the effectiveness of the DSTATCON from the viewpoints of voltage regulation and harmonic mitigation in a distribution line. For the reliable modeling, detailed information on distribution system and loads is performed by field measurements. The DSTATCON has been modeled according to the control algorithm of real controller. The effectiveness of the DSTATCON installation is verified by simulation using EMTDC.

  • PDF

회로 특성 파라미터에 근거한 전력 증폭기의 비선형 응답 특성 (Analysis of Power Amplifier Nonlinear Response Based on Practical Circuit Parameters)

  • 박용국;김형석
    • 전기학회논문지
    • /
    • 제61권5호
    • /
    • pp.721-725
    • /
    • 2012
  • In this paper, a novel analysis on the nonlinear response of a power amplifier (PA) with the intermodulation distortion (IMD) asymmetry is proposed based on the mutislice behavioral model. The coefficients of the odd-order and even-order polynomial of that model are represented with the PA practical circuit parameters such as intercept points, gain and amplitudes of excitation inputs. We also develop the analytic expressions to distinguish baseband frequency effect from second harmonic effect on the IMD asymmetry. We also validate the derived analytic expressions through measurements.

공장전기설비에서의 누전차단기 오동작과 전력품질 분석 (Power Quality Analysis and Failure of Earth Leakage Breakers in Plant)

  • 이상의;유재근;전정채;전현재;허혜성;최규하
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.479-481
    • /
    • 2007
  • This paper presented a actual conditions on a false-tripping of ELB(Earth Leakage Breakers) and an assessment of the harmonics due to non-linear electronic equipment such as personal computers, rectifier, electric furnace and test equipments in plant installations. Actual conditions on a failure of ELB were surveyed and analyzed by making up a question to safety managers of plant installations. Also, power quality measurements such as harmonic currents, voltage and current waveform and current imbalance were made at various plant installations where nuisance tripping of ELB is often occurred. The results of this study can be used in making decisions regarding cause of ELB trip and operating and tripping characteristics test of ELB when subjected to distorted current waveform.

  • PDF

카이랄 키토산 고분자의 표면 방향 분포 연구 (Surface orientational distributions of chiral chitosan-polymer)

  • N. Y. Ha;S. H. Han;H. J. Chang;J. S. Hwang;D. W. Jeon;Jung, Chi-Sup;Park, Byoungchoo;J W. Wu
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2003년도 하계학술발표회
    • /
    • pp.168-169
    • /
    • 2003
  • We have determined the orientational distribution functions (OBFs) at both air and substrate isotropic interfaces of a chiral chitosan bio-polymer film by the measurements of surface second-harmonic generation (SHG). It was shown that the simultaneous SHG analysis of both interfaces, based on the macroscopic and microscopic relations, provides all the informations on the nonlinear optical (NLO) activity. (omitted)

  • PDF

In-situ fatigue monitoring procedure using nonlinear ultrasonic surface waves considering the nonlinear effects in the measurement system

  • Dib, Gerges;Roy, Surajit;Ramuhalli, Pradeep;Chai, Jangbom
    • Nuclear Engineering and Technology
    • /
    • 제51권3호
    • /
    • pp.867-876
    • /
    • 2019
  • Second harmonic generation using nonlinear ultrasonic waves have been shown to be an early indicator of possible fatigue damage in nuclear power plant components. This technique relies on measuring amplitudes, making it highly susceptible to variations in transducer coupling and instrumentation. This paper proposes an experimental procedure for in-situ surface wave nonlinear ultrasound measurements on specimen with permanently mounted transducers under high cycle fatigue loading without interrupting the experiment. It allows continuous monitoring and minimizes variation due to transducer coupling. Moreover, relations describing the effects of the measurement system nonlinearity including the effects of the material transfer function on the measured nonlinearity parameter are derived. An in-situ high cycle fatigue test was conducted using two 304 stainless steel specimens with two different excitation frequencies. A comprehensive analysis of the nonlinear sources, which result in variations in the measured nonlinearity parameters, was performed and the effects of the system nonlinearities are explained and identified. In both specimens, monotonic trend was observed in nonlinear parameter when the value of fundamental amplitude was not changing.

A spectral model for human bouncing loads

  • Jiecheng Xiong;Jun Chen
    • Structural Engineering and Mechanics
    • /
    • 제86권2호
    • /
    • pp.237-247
    • /
    • 2023
  • Fourier series-based models in the time domain are frequently established to represent individual bouncing loads, which neglects the stochastic property of human bouncing activity. A power spectral density (PSD) model in the frequency domain for individual bouncing loads is developed herein. An experiment was conducted on individual bouncing loads, resulting in 957 records linked to form long samples to achieve a fine frequency resolution. The Welch method was applied to the linked samples to obtain the experimental PSD, which was normalized by the bouncing frequency and the harmonic order. The energy, energy distribution center, and energy distribution shape of the experimental PSD were investigated to establish the PSD model. The proposed model was used to analyze structural vibration responses using stochastic vibration theory, which was verified via field measurements. It is believed that this framework can evaluate the vibration capacity of structures excited by bouncing crowds, such as concert halls and grandstands.