• Title/Summary/Keyword: Harmonic measurements

Search Result 127, Processing Time 0.033 seconds

The Evaluation of Medium Voltage Motor's Current and Voltage Harmonics during Loading

  • Alboyaci, Bora;Yorukeren, Nuran
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.1
    • /
    • pp.35-41
    • /
    • 2007
  • This paper presents the results of investigating harmonic levels on medium voltage motors at loading conditions in air separation plant. The essential results of the measurements of the medium voltage motor harmonics are summarized in the values for the total harmonic distortion (THD). Motors loading case is used to assess the current and voltage harmonic distortions. Proper system analysis is important when adding a new motor starting and controlling the equipment. With the result of the paper it is possible to suggest the most appropriate starting and control method. Two medium voltage motors of air separation unit measurement results and simulations are summarized. Both current and voltage harmonic distortions are fitted by using a linear and exponential regression model. The prediction of THD values can be used for this kind of process for future planning by utilities.

Harmonic Generation and System Response Characteristics in Electrified Railway(II) - Focused on Measurement and Analysis - (전기철도에서의 고조파 발생과 계통응답특성(II) - 고조파 측정분석을 중심으로 -)

  • 오광해;이한민
    • Journal of the Korean Society for Railway
    • /
    • v.7 no.1
    • /
    • pp.65-69
    • /
    • 2004
  • In reference to this study, Part Ⅰ showed how the system respond to the harmonics originated from electric locomotives. That is, the system response to the harmonics was derived by computational algorithm with numerical formulas in theoretical aspects. However, Real catenary system has complex configuration of conductors and it is an important point that if we can consider the circuit element of catenary conductors as an uniformly distributed RLC element. Moreover, harmonic characteristics in electric locomotive depend on its operational modes. From these point of view, measurements of harmonics are performed for real railway power supply systems under the various operational modes, and spectrum and distortion analyses in measurement data are described.

A Study on the Harmonic Characteristics of GHP Cooling/Heating Load in an Institutional Building (교육용 건물의 GHP 냉/난방 부하의 고조파 특성에 관한 연구)

  • Kim, Kyung-Chul;Oh, Kyung-Hoon;Lee, Kyu-Jin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.4
    • /
    • pp.29-38
    • /
    • 2009
  • The GHP(Gas Heat Pump) is an efficient cooling;11eating system in which a compressor is driven by a gas engine and is brodening its application to the facilities such as schools and office buildings. It is difficult to control the GHP system because of slow response, big time constant and time variant system. These nonlinear loads generate harmonic currents and create distortions on the sinusoidal voltage of the power system Harmonic field measurements have shown that the harmonic contents of a waveform varies with time. A cumulative probability approach is the most commonly used method to solve time varying harmonics. This paper provides an in depth analysis on harmonics field measurement of the GHP loads, harmonic assessment by me 61000-3-2, and harmonic simulation and harmonic filter application using EDSA program for the case study system.

A Study on the Hormonic Characteristics of Typical Household Loads by Field Measurements (현장 측정에 의한 가정집 부하의 고조파 특성에 관한 연구)

  • Kim, Kyung-Chul;Oh, Kyung-Hoon;Choi, Hyoung-Bumb
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.4
    • /
    • pp.100-106
    • /
    • 2008
  • Typical household load have nonlinear loads including a personal computer, video, refrigerator, microwave oven, TV, and audio set. These nonlinear loads generate harmonic currents and create distortions on the sinusoidal voltage of the power system. Harmonic field measurements have shown that the harmonic contents of a waveform varies with time. A cumulative probablistic approach is the most commonly used method to solve time varying harmonics. This paper provides in depth analysis on harmonics field measurement of the typical household loads and harmonics simulation using EDSA program for the case study.

The Ground Impedance Influence on Neutral Harmonic Currents (접지 임피던스가 중성선 고조파 전류에 미치는 영향)

  • Kim, Kyung-Chul;Paik, Seung-Hyun;Lee, Il-Moo;Kim, Jong-Uk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.3
    • /
    • pp.120-127
    • /
    • 2004
  • With the proliferation of nonlinear loads such as switching mode power supplies, high neurtral harmonic currents in three-phase four-wire distribution system have been observed. It has been known that the grounded impedance has an effect on the neutral current of a system which operates with harmonics present since the neutral conductor is grounded. On-site measurements of harmonic currents and voltages were made and the corresponding equivalent circuit was developed. The circuit model under study was simulated numerically and graphically through the use of the software MATLAB. Simulation results verifying the relationship between the neutral harmonic current and ground impedance are presented.

The Ground Impedance Modeling using pattern Search Method for Neutral Hormonic Analysis (Pattern Search 법을 이용한 중성선 고조파 해석용 접지 임피던스 모델링)

  • 백승현;김경철;최종기;이일무;백남웅
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.4
    • /
    • pp.181-187
    • /
    • 2004
  • With the proliferation of nonlinear loads, high neutral harmonic currents in three-phase four-wire distribution system have been observed. It has been known that the ground impedance has an effect on the neutral currents of a system which operates with harmonics present. On-site measurements of harmonic currents and voltages according to the fall-of-potential method under case study system were made and the ground impedance modeling using the pattern search method for the harmonic analysis was developed The ground impedance model obtained by the proposed method was compared with the frequency characteristics by field tests and has shown appropriate results, and would be applicable to evaluate the harmonic and transient response characteristics of the ground system.

A study on efficiency improvement of power amplifier from enhanced harmonic suppression using DGS coupled line (DGS 결합선로를 이용하여 고조파 억압특성을 향상시킨 전력증폭기의 효율증대에 관한 연구)

  • Song, Dae-Geon;Kim, Jang-Won
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.2 no.4
    • /
    • pp.13-18
    • /
    • 2009
  • This paper suggests that efficiency improvement of power amplifier to enhance harmonic suppression using a DGS line structure. A efficiency related harmonic component is an important factor to design of power amplifier. Therefor harmonic component suppress consisting coupled line using DGS after power amplifier. A DGS line with periodic slits and stubs is first designed and joined after power ampifier. Experimental measurements for efficiency of power amplifier in the WCDMA are shown to improve 6% of PAE.

  • PDF

Global GPS Ionospheric Modelling Using Spherical Harmonic Expansion Approach

  • Choi, Byung-Kyu;Lee, Woo-Kyung;Cho, Sung-Ki;Park, Jong-Uk;Park, Pil-Ho
    • Journal of Astronomy and Space Sciences
    • /
    • v.27 no.4
    • /
    • pp.359-366
    • /
    • 2010
  • In this study, we developed a global ionosphere model based on measurements from a worldwide network of global positioning system (GPS). The total number of the international GPS reference stations for development of ionospheric model is about 100 and the spherical harmonic expansion approach as a mathematical method was used. In order to produce the ionospheric total electron content (TEC) based on grid form, we defined spatial resolution of 2.0 degree and 5.0 degree in latitude and longitude, respectively. Two-dimensional TEC maps were constructed within the interval of one hour, and have a high temporal resolution compared to global ionosphere maps which are produced by several analysis centers. As a result, we could detect the sudden increase of TEC by processing GPS observables on 29 October, 2003 when the massive solar flare took place.

A Study on the Harmonics Evaluation of Extra High Voltage Customers by Field Tests (실측에 의한 특고압 수용가의 고조파 평가에 관한 연구)

  • Kim, Kyung-Chul;Kim, You-June
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.3
    • /
    • pp.50-55
    • /
    • 2007
  • A large steel industry which has nonlinear loads including electric arc furnaces is one of the extra high voltage customers. These nonlinear loads generate harmonic currents and create distortions on the sinusoidal voltage of the power system. Harmonic field measurements have shown that the harmonic contents of a waveform varies with time. A cumulative propablistic approach is the most commonly used method to solve time varying harmonics. In this paper the in varying harmonics of electric arc furnace loads are evaluated by international harmonic standards(IEC 61000-3-6, IEEE 519 and JIS C 61000-3-2).

Experimental validation of smartphones for measuring human-induced loads

  • Chen, Jun;Tan, Huan;Pan, Ziye
    • Smart Structures and Systems
    • /
    • v.18 no.3
    • /
    • pp.625-642
    • /
    • 2016
  • The rapid technology developments in smartphones have created a significant opportunity for their use in structural live load measurements. This paper presents extensive experiments conducted in two stages to investigate this opportunity. Shaking table tests were carried out in the first stage using selected popular smartphones to measure the sinusoidal waves of various frequencies, the sinusoidal sweeping, and earthquake waves. Comparison between smartphone measurements and real inputs showed that the smartphones used in this study gave reliable measurements for harmonic waves in both time and frequency domains. For complex waves, smartphone measurements should be used with caution. In the second stage, three-dimensional motion capture technology was employed to explore the capacity of smartphones for measuring the movement of individuals in walking, bouncing and jumping activities. In these tests, reflective markers were attached to the test subject. The markers' trajectories were recorded by the motion capture system and were taken as references. The smartphone measurements agreed well with the references when the phone was properly fixed. Encouraged by these experimental validation results, smartphones were attached to moving participants of this study. The phones measured the acceleration near the center-of-mass of his or her body. The human-induced loads were then reconstructed by the acceleration measurements in conjunction with a biomechanical model. Satisfactory agreement between the reconstructed forces and that measured by a force plate was observed in several instances, clearly demonstrating the capability of smartphones to accurately assist in obtaining human-induced load measurements.