• 제목/요약/키워드: Harmonic instability

검색결과 73건 처리시간 0.025초

레이저와 프라즈마와의 비선형상오작용에 관한 연구 -분광법에 의한 제 2고주파와 Brillouin 산람광의 검출- (Study on the Nonlinear Interaction of Laser with Plasma -Detection of Second Harmonic Light and Brillouin Scattering Light by Means of Spectroscopic Technique-)

  • Kang, Hyung-Boo
    • 대한전기학회논문지
    • /
    • 제33권5호
    • /
    • pp.173-180
    • /
    • 1984
  • The spectra of scattering light fromlaser-produced plasma near its fundamental and second harmonic wavelength were observed respectively by means of spectroscopic technique. The experimental results and the generation mechanism of nonlinear effects such as the second garmonics and the brillouin scattering were analysed theoretically. The spectra of reflected laser light became wider than that of incident laser light. And the peak of spectrum of reflected light shifted to red-side from that of incident light. The second harmonic light is generated from the nonlinear interaction of the incident laser light and the electron plasma wave excited in resonance region by the oblique incidence of laser light to the plasma. The Brillouin backscattering from laser-produced plasmas of hydrogen and deuterium has shown an isotope effect in the red-side region of the generated second harmonic light. This isotope shift is explained by the parametric instability at the cutoff (resonance) region using frequency-and phase-matching conditions of the waves.

  • PDF

SHE-PWM을 적용한 STATCOM에 의한 저차고조파 제거 방법 (Elemination of Low Order Harmonics from STATCOM using SHE-PWM)

  • 최순호;김찬기;이성두
    • 전력전자학회논문지
    • /
    • 제19권5호
    • /
    • pp.450-456
    • /
    • 2014
  • In HVDC converters that employ a line-commutated control, reactive power is absorbed by the rectifier and inverter terminals during AC/DC conversion. An AC filter usually consists of filters and large shunt capacitors to supply reactive power to the HVDC station. When STATCOM is used to supply reactive power to the HVDC system with AC filter, the low-order harmonics generated from STATCOM can result in a resonance between the shunt capacitor and AC network. Therefore, a control strategy based on selective harmonic elimination is adopted to minimize the low-order harmonics from STATCOM. The cancellation of harmonic instabilities is verified through simulations in PSCAD/EMTDC.

특수수용가의 고조파전압 왜형현황과 고조파 관리 방안 (Harmonic Distortion Level of Special loads and Method of Harmonic Distortion Management)

  • 황치우;성기철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 D
    • /
    • pp.875-877
    • /
    • 1997
  • Due to the development of electric energy conversion technology and need for energy saving most of the electric machinery and equipments are using power semiconductor switching elements, On the contrary semiconductor switching device is more sensitive to the voltage instability and voltage distortion. In order to manage the voltage distortion following foundation should be settled down in advance. First, reasonable and objective technical guidelines should be established. Second, monitoring network for power quality should be operated. In this paper measurement results of the harmonic distortion of the special loads are given and method for harmonic pollution management is discussed.

  • PDF

저속 유동장이 있는 원통형 연소기에서의 열-음향학적 불안정에 대한 능동 제어 연구 (Active Control of Thermoacoustic Instability in Cylindrical Combustor with Low Speed Flow Field)

  • 조상연;이용석;이수갑;배충식
    • 소음진동
    • /
    • 제8권5호
    • /
    • pp.914-921
    • /
    • 1998
  • Combusion instability due to thermoacoustic feedback in a ducted combustor usually excites severe noise and vibration, which could lead to result in the failure of the system or environmental dispute. In the present study, an active noise control(ANC) method with an adaptive algotithm is hired to suppress instability which has very discrete behavior in the frequency domain. Especially a feedback system is composed to evade hot environment of the combustor, and as a preliminary, the performance and stability of the controller is chekced by simulating the real situation with harmonic waves. Application to the real combustor showed serious reductions in sound pressure level by 20∼30 dB. It was also shown that the selected control system was very stable and effective.

  • PDF

Parametric resonance of axisymmetric sandwich annular plate with ER core layer and constraining layer

  • Yeh, Jia-Yi
    • Smart Structures and Systems
    • /
    • 제8권5호
    • /
    • pp.487-499
    • /
    • 2011
  • The parametric resonance problems of axisymmetric sandwich annular plate with an electrorheological (ER) fluid core and constraining layer are investigated. The annular plate is covered an electrorheological fluid core layer and a constraining layer to improve the stability of the system. The discrete layer annular finite element and the harmonic balance method are adopted to calculate the boundary of instability regions for the sandwich annular plate system. Besides, the rheological property of an electrorheological material, such as viscosity, plasticity, and elasticity can be changed when applying an electric field. When the electric field is applied on the sandwich structure, the damping of the sandwich system is more effective. Thus, variations of the instability regions for the sandwich annular plate with different applying electric fields, thickness of ER layer, and some designed parameters are presented and discussed in this study. The ER fluid core is found to have a significant effect on the location of the boundaries of the instability regions.

유한요소법을 이용한 부분 예혼합 가스터빈 연소기에서의 연소불안정 모델링 (Combustion Instability Modeling in a Partially-premixed Gas Turbine Combustor using Finite Element Method)

  • 장세구;김대식;주성필;윤영빈
    • 한국분무공학회지
    • /
    • 제23권1호
    • /
    • pp.16-21
    • /
    • 2018
  • The current study has developed an in-house 3D FEM code in order to model thermoacoustic problems in a gas turbine combustion system and compared calculation results of main instability characteristics with measured ones from a lab-scale partially-premixed combustor. From the comparison of calculation results with the measured data, the current model could successfully capture the harmonic longitudinal instability frequencies and their spatial distributions of the acoustic field as well as the growth rate of self-excited modes.

Instability and vibration analyses of FG cylindrical panels under parabolic axial compressions

  • Kumar, Rajesh;Dey, Tanish;Panda, Sarat K.
    • Steel and Composite Structures
    • /
    • 제31권2호
    • /
    • pp.187-199
    • /
    • 2019
  • This paper presents the semi-analytical development of the dynamic instability behavior and the dynamic response of functionally graded (FG) cylindrical shallow shell panel subjected to different type of periodic axial compression. First, in prebuckling analysis, the stresses distribution within the panels are determined for respective loading type and these stresses are used to study the dynamic instability behavior and the dynamic response. The prebuckling stresses within the shell panel are the same as applied in-plane edge loading for the case of uniform and linearly varying loadings. However, this is not true for the case of parabolic loadings. The parabolic edge loading produces all the stresses (${\sigma}_{xx}$, ${\sigma}_{yy}$ and ${\tau}_{xy}$) within the FG cylindrical panel. These stresses are evaluated by minimizing the membrane energy via Ritz method. Using these stresses the partial differential equations of FG cylindrical panel are formulated by applying Hamilton's principal assuming higher order shear deformation theory (HSDT) and von-$K{\acute{a}}rm{\acute{a}}n$ non-linearity. The non-linear governing partial differential equations are converted into a set of Mathieu-Hill equations via Galerkin's method. Bolotin method is adopted to trace the boundaries of instability regions. The linear and non-linear dynamic responses in stable and unstable region are plotted to know the characteristics of instability regions of FG cylindrical panel. Moreover, the non-linear frequency-amplitude responses are obtained using Incremental Harmonic Balance (IHB) method.

New Techniques for Impedance Characteristics Measurement of Islanded Microgrid based on Stability Analysis

  • Hou, Lixiang;Zhuo, Fang;Shi, Hongtao
    • Journal of Power Electronics
    • /
    • 제16권3호
    • /
    • pp.1163-1175
    • /
    • 2016
  • In recent years, microgrids have been the focus of considerable attention in distributed energy distribution. Microgrids contain a large number of power electronic devices that can potentially cause negative impedance instability. Harmonic impedance is an important tool to analyze stability and power quality of microgrids. Harmonic impedance can also be used in harmonic source localization. Precise measurement of microgrid impedance and analysis of system stability with impedances are essential to increase stability. In this study, we introduce a new square wave current injection method for impedance measurement and stability analysis. First, three stability criteria based on impedance parameters are presented. Then, we present a new impedance measurement method for microgrids based on square wave current injection. By injecting an unbalanced line-to-line current between two lines of the AC system, the method determines all impedance information in the traditional synchronous reference frame d-q model. Finally, the microgrid impedances of each part and the overall microgrid are calculated to verify the measurement results. In the experiments, a simulation model of a three-phase AC microgrid is developed using PSCAD, and the AC system harmonic impedance measuring device is developed.

Investigation of Instability in Multiple Grid-Connected Inverters with LCL Output Filters

  • Asghari, Fariba;Safavizadeh, Arash;Karshenas, Hamid Reza
    • Journal of Power Electronics
    • /
    • 제18권3호
    • /
    • pp.757-765
    • /
    • 2018
  • This paper deals with the instability and resonant phenomena in distribution systems with multiple grid-connected inverters with an LCL output filter. The penetration of roof-top and other types of small photovoltaic (PV) grid-connected systems is rapidly increasing in distribution grids due to the attractive incentives set forth by different governments. When the number of such grid-connected inverters increases, their interaction with the distribution grid may cause undesirable effects such as instability and resonance. In this paper, a grid system with several grid-connected inverters is studied. Since proportional-resonant (PR) controllers are becoming more popular, it is assumed that most inverters use this type of controller. An LCL filter is also considered at the inverters output to make the case as realistic as possible. A complete modeling of this system is presented. Consequently, it is shown that such a system is prone to instability due to the interactions of the inverter controllers. A modification of PR controllers is presented where the output capacitor is virtually decreased. As a result, the instability is avoided. Simulation results are presented and show a good agreement with the theoretical studies. Experimental results obtained on a laboratory setup show the validity of the analysis.

STUDY OF VOLTAGE AND HARMONIC STABILITY OF CAPACITOR COMMUTATED CONVERTERS APPLIED TO HVDC/BTB

  • Konishi, Hiroo;Yamada, Tatsuo;Sanpei, Masatoshi;Sano, Takayoshi
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.898-902
    • /
    • 1998
  • Voltage and harmonic stability characteristics of capacitor commutated converters applied to a BTB (back to back) system (CCC-BTB) are analyzed and compared to characteristics of a BTB system composed of conventional line commutated converters (LCC-BTB). About 1.6 times larger safe operating regions can be obtained for the CCC-BTB system compared to the latter. The CCC-BTB system results in no harmonic instability problem as it has no shunt reactive compensators in the station and the adjoining AC system generates no low anti-res onance points.

  • PDF