• Title/Summary/Keyword: Harmonic injection method

Search Result 55, Processing Time 0.038 seconds

Novel Islanding Detection Method for Distributed Generation Interconnected with Utility Grid (계통연계 분산전원의 새로운 단독운전 판별기법)

  • Bae, Byung-Yeol;Lee, Doo-Young;Ko, Jong-Sun;Choi, Nam-Sub;Han, Byung-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.1
    • /
    • pp.65-72
    • /
    • 2008
  • This paper describes the development of a novel islanding detection method, which uses the signal cross-corelation scheme between the injected reactive current and the power frequency deviation. The existing method, which injects the reactive current of 2.5-5% to the rated current and detects the frequency deviation directly, brings about lowing the power quality due to the harmonic pollution. The proposed method eliminates the weak point of the existing method, because it injects the reactive current less than 1% to the rated current. The operational feasibility was verified through computer simulations with PSCAD/EMTDC software, and experimental works with a 10kVA hardware prototype. The proposed method can detect the islanding status effectively without lowing the power quality of interconnected distributed generation system.

Novel Control Method for a Hybrid Active Power Filter with Injection Circuit Using a Hybrid Fuzzy Controller

  • Chau, MinhThuyen;Luo, An;Shuai, Zhikang;Ma, Fujun;Xie, Ning;Chau, VanBao
    • Journal of Power Electronics
    • /
    • v.12 no.5
    • /
    • pp.800-812
    • /
    • 2012
  • This paper analyses the mathematical model and control strategies of a Hybrid Active Power Filter with Injection Circuit (IHAPF). The control strategy based on the load harmonic current detection is selected. A novel control method for a IHAPF, which is based on the analyzed control mathematical model, is proposed. It consists of two closed-control loops. The upper closed-control loop consists of a single fuzzy logic controller and the IHAPF model, while the lower closed-control loop is composed of an Adaptive Network based Fuzzy Inference System (ANFIS) controller, a Neural Generalized Predictive (NGP) regulator and the IHAPF model. The purpose of the lower closed-control loop is to improve the performance of the upper closed-control loop. When compared to other control methods, the simulation and experimental results show that the proposed control method has the advantages of a shorter response time, good online control and very effective harmonics reduction.

Design and Feedback Performance Analysis of the Inverter-side LC Filters Used in the DVR System (DVR시스템에 사용되는 인버터부의 LC필터 설계와 피드백 성능분석)

  • Park, Jong-Chan;Shon, Jin-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.2
    • /
    • pp.79-84
    • /
    • 2015
  • Voltage sags are considered the dominant disturbances affecting power quality. Dynamic voltage restorers(DVRs) are mainly used to protect sensitive loads from the electrical network voltage disturbances such as sags or swells and could be used to reduce harmonic distortion of ac voltages. The typical DVR topology essentially contains a PWM inverter with LC Filter, an injection transformer connected between the ac voltage line and the sensitive load, and a DC energy storage device. For injecting series voltage, the PWM inverter is used and the passive filter consist of inductor(L) and capacitor(C) for harmonics elimination of the inverter. However there are voltage pulsation responses by the characteristic of the LC passive filter that eliminate the harmonics of the PWM output waveform of the inverter. Therefore, this paper presented design and feedback performance of LC filter used in the DVRs. The voltage control by LC filter should be connected in the line side since this feedback method allows a relatively faster dynamic response, enabling the elimination of voltage notches or spikes in the beginning and in the end of sags and strong load voltage THD reduction. Illustrative examples are also included.

Islanding Detection for PV System Connected to a Utility Grid

  • Han, Seok-Woo;Mok, Hyung-Soo;Choe, Gyu-Ha
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.719-723
    • /
    • 1998
  • Prevention of the islanding phenomena is one of the most important issues because it can damage electrical equipment connected to the utility system and endanger human life. It is very difficult to detect an islanding condition of a power distribution line with conventional voltage of frequency relays, while the output power and the load power of utility interactive PV inverter units are in nearly balanced state in both active power and reactive power. This paper describes the protective equipment that prevents the PV system connected to the utility grid from starting islanding. Both predictive ocntrol method and harmonic injection method are used for a current control and islanding detection for operating safety.

  • PDF

A Novel Hybrid Anti-islanding Method to Improve Reliability of Utility Interactive Inverter for a PMSG-based Wind Power Generation System (PMSG 기반 풍력발전용 계통연계 인버터의 신뢰성 향상을 위한 새로운 하이브리드 단독운전 방지기법)

  • Kang, Sung-Wook;Kim, Kyeong-Hwa
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.11
    • /
    • pp.27-36
    • /
    • 2013
  • Islanding in a gird connected inverter of wind power generation system may influence a bad effect on equipments or yield safety hazards on grid so it should be detected rapidly and exactly. A passive method to detect islanding is comparatively simpler than an active method but suffers from non detection zone (NDZ). On the other hand, the active method can significantly reduce NDZ by injecting a disturbance into inverter output. To improve the reliability of islanding detection, this paper proposes a hybrid anti-islanding detection method combining the conventional passive method as well as the active method based on novel harmonic injection method using fourier transform. The proposed scheme is fast to detect islanding when NDZ does not exist because it has the nature of passive method. Under NDZ, the active method can detect occurrence of islanding reliably. The effectiveness and validity of the proposed scheme is proved through comparative simulations.

Anti-islanding Method by Harmonic Injection for Utility Interactive Inverter with Critical Load (중요부하를 갖는 계통연계형 인버터의 고조파주입에 의한 단독운전방지 기법)

  • Oh, Hyeong-Min;Choi, Se-Wan;Kim, Tae-Hee;Lee, Gi-Pung;Lee, Tae-Won
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.4
    • /
    • pp.315-321
    • /
    • 2012
  • The utility-interactive inverter with critical loads should supply continuous and stable voltage to critical loads even during the grid fault. The conventional control method which performs current control for grid-connected mode and voltage control for stand-alone mode undergoes the critical load voltage variation during grid fault. The critical load voltage may have large transient when the inverter performs mode transfer after the islanding detection. Recently, the indirect current control method which does not have the transient state during not only islanding detection but also the mode transfer has been proposed. However, since the voltage control is maintained even during the grid-connected mode it is difficult to detect the islanding. This paper proposes an active anti-islanding method suitable for the indirect current control method which does not have NDZ(Non-Detection Zone).

A New Harmonic Reduction Method of Diode Rectifier by Zero-Sequence Current Injection (새로운 영상전류 주입법에 한 다이오드 정류기의 고조파 저감)

  • Kim, Hyun-Jung;Jang, Min-Soo;Choi, Se-Wan;Won, Chung-Yeun;Kim, Gyu-Sik
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.546-550
    • /
    • 2002
  • 본 논문에서는 다이오드 정류기에 단상인버터와 변압기를 이용하여 영상고조파 전류를 주입함으로서 순수한 정현파 입력전류를 얻을 수 있는 새로운 방식의 고조파 저감기술을 제안한다. 본 방식은 주 전력의 흐름에 직렬로 스위칭소자가 연결되지 않아 전력손실이 적으며 보조회로로서 사용된 변압기의 턴비를 조정하면 인버터 스위치의 전류정격을 작게 구현할 수 있다. 본 방식의 타당성을 실험을 통하여 입증하였다.

  • PDF

Harmonic Injection Method for Increasing DC-link Voltage in Drive Systems with Single-Phase Diode Rectifier and Small DC-link Capacitor (단상 다이오드 정류기와 소용량 직류단 캐패시터를 가지는 전동기 구동 시스템에서 직류단 전압을 높이기 위한 고조파 주입법)

  • Chae, Young-Ho;Ha, Jung-Ik
    • Proceedings of the KIPE Conference
    • /
    • 2015.11a
    • /
    • pp.65-66
    • /
    • 2015
  • 본 논문에서는 단상 다이오드 정류기와 소용량 직류단 캐패시터를 가지는 전동기 구동 시스템에서 계통 전류에 최소 고조파 전류 주입을 통하여 직류단 전압을 높이는 방법을 제안한다. 소용량 직류단 캐패시터를 가지는 전동기 구동 시스템은 직류단전압이 맥동하게 되는데 직류단 전압이 낮은 부분에서는 과도한 약자속 전류가 필요하게 된다. 기존의 연구에서는 직류단 전압을 확보하기 위해 직류단 최소 전압을 설정하는 방법이 제안되었다. 하지만 계통 전류의 고조파 규정 때문에 직류단 최소 전압을 높이는 것은 한계가 있다. 제안된 방법에서는 계통 전류에 고조파를 주입함으로써 기존의 한계보다 더 높은 직류단 최소 전압을 가지면서도 계통 전류의 고조파 규정을 만족시킬 수 있도록 한다. 제안된 방법은 시뮬레이션을 통해 그 타당성을 검증한다.

  • PDF

The Efficacy of Percutaneous Steroid Injection via Cricothyroid Membrane for Reinke's Edema (라인케씨 부종 환자에서 경윤상 갑상막 접근을 통한 성대 내 스테로이드 주입술의 효용)

  • Nam, Woojoo;Kim, Sun Woo;Jin, Sung Min;Lee, Sang Hyuk
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.30 no.2
    • /
    • pp.101-106
    • /
    • 2019
  • Background and Objectives Reinke's edema is a benign vocal fold disease caused by an edematous laryngeal superficial layer of lamina propria. The first line treatment is cessation of smoking and laryngeal microsurgery. The aim of the study is to evaluate the feasibility and efficacy of percutaneous steroid injection via cricothyroid membrane in patients with Reinke's edema. Materials and Method From Jan 2010 to July 2018, 33 Patients with Reinke's edema managed by vocal fold steroid injection via the cricothyroid membrane were included in this study. We compared medical records of laryngoscopy, stroboscopy and Multi-Dimensional Voice Program analysis at pre-treatment and post-treatment. Subjective voice improvement was evaluated using Voice Handicap Index-30 (VHI-30). Results 75.7% of the patients showed partial response and 6.06% showed complete response. 93.94% were present smokers and only 4 patients ceased smoking after the treatment. In acoustic analysis, the pre-treatment mean value of jitter, shimmer, and noise to harmonic ratio was 2.30±3.21, 9.34±10.37, 1.11±2.90 each. The post-treatment value was 2.20±1.89, 6.96±5.30, 0.20±0.09 respectively and none of the parameters were statistically significant. For subjective symptom improvement, 25 (75.8%) patients showed a better score on post-treatment VHI-30 compared to pre-treatment. Conclusion According to our study, steroid injection is a relatively safe and effective procedure for patients with Reinke's edema. A vocal fold steroid injection via the cricothyroid membrane can be an alternative treatment option for those who are not able to undergo conventional laryngeal microscopic surgery, however cessation of smoking is necessary for effective treatment.

Line-Interactive DVR Using Multi-Level H-Bridge Inverter (멀티-레벨 H-Bridge 인버터를 이용한 Line-Interactive DVR)

  • Kang Dae-Wook;Woo Sung-Min;Kim Tae-Jin;Choi Chang-Ho;Hyun Dong-Seok
    • Proceedings of the KIPE Conference
    • /
    • 2001.12a
    • /
    • pp.139-143
    • /
    • 2001
  • Recently, the interest on power quality has been hot issue. The equipments cause voltage disturbance and has become more sensitive to the voltage disturbance. This paper deals with 5-Level H-Bridge Line-Inter active Dynamic Voltage Restorer(LIDVR) system. The LIDVR has following advantages in comparison with the DVR with series injection transformer It has the power factor near to unity under normal source voltage, can compensate the harmonic current of the load and the instant interruption, and has the fast response. First, the construction, the operation mode and algebraic modeling of LIDVR are reviewed. And then a voltage controller is proposed to get sinusoidal load voltage with constant amplitude. To find PWM method suitable for H-Bridge converter, two PWM methods are compared and analyzed. Finally, simulation results verify the proposed 5-level H-Bridge LIDVR system.

  • PDF