• 제목/요약/키워드: Harmonic injection

검색결과 97건 처리시간 0.021초

배전계통의 고조파 분포 계산 프로그램 (A Program for Calculation of Harmonic Distribution in Distribution Systems)

  • 김성수;강용철;남순열;박종근;명성호;강영석;최효열
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 B
    • /
    • pp.817-819
    • /
    • 1996
  • This paper presents an algorithm for calculation of harmonic distribution in distribution systems. In distribution systems, most state variables are not given explicitly. To calculate the harmonic distribution in distribution systems, state estimation is necessary. In this paper, power usage and harmonic current injection is estimated for each node from practically available data. The estimating procedure is illustrated by examples.

  • PDF

Single stage PFC flyback 컨버터의 전해커패시터용량저감기법 (The Method of Reducing the Output Electrolytic Capacitance in Single Stage PFC flyback Converter)

  • 김진구;박종연
    • 조명전기설비학회논문지
    • /
    • 제29권9호
    • /
    • pp.81-88
    • /
    • 2015
  • LED has been great attentions in lighting industry because of its long life-time, high efficiency, excellent light output characteristics. However, the life-time of the LED driving system is decreased because of the electrolytic capacitor which is used in the power conversion system for driving LED lighting. Therefore the capacitance reduction methods have been studied to replace an electrolytic capacitor with film or tantalum capacitor. This paper presents the Single stage PFC flyback converter with the simplified third harmonic current injection circuit to reduce output capacitance and the proposed system is theoretically analyzed and verified through the experiment.

단위 역률을 갖는 3상 강압형 다이오드 정류기에서 고조파 주입에 의한 DC 리플전압 저감 기법 (A DC Ripple Voltage Suppression Scheme by Harmonic Injection in Three Phase Buck Diode Rectifiers with Unity Power Factor)

  • 고종진
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.305-308
    • /
    • 2000
  • A technique to suppress the low frequency ripple voltage of the DC output in three phase buck diode rectifiers is presented in this paper. The proposed pulse frequency modulation methods and duty ratio modulation methods are employed to regulate the output voltage of the buck diode rectifiers and guarantee zero-current -switching(ZCS) of the switch over the wide load range The proposed control methods used in this paper provide generally good performance such as low THD of the input line current and unity power factor. IN addition control methods can be effectively used to suppress the low frequency ripple voltage appeared in the dc output voltage. The harmonic injection technique illustrates its validity and effectiveness through the simulations.

  • PDF

고조파 주입에 의한 계통연계형 태양광발전시스템의 고립운전 검출 (Islanding Detection by Harmonic Current Injection Method for Utility Interactive Photovoltaic System)

  • 고재석;채영민;강병희;최규하
    • 전력전자학회논문지
    • /
    • 제8권2호
    • /
    • pp.199-210
    • /
    • 2003
  • 본 논문에서는 계통연계형 태양광발전시스템의 고립운전방지를 위한 새로운 고리운전 검출기법을 연구한다. 이를 위하여 계통연계형 태양광발전시스템 및 고립운전시의 특성에 대하여 기술하였다. 또한 고립운전의 검출특성을 향상시키기 위한 새로운 검출기법을 제시하고 해석하였으며 검출시험을 위한 부하조건 선정을 위한 부하임피던스 곡선을 해석적으로 유포하였다 ACSL 시뮬레이션 및 실험을 통하여 제시한 고립운전 검출기법 및 해석결과를 검증하였다.

플랜트 설계 시 배관진동을 유발하는 가진 함수의 수학적 모델링 (A Study on Mathematical Modeling of Forcing Function for the Piping Vibration of Petrochemical Plant Design)

  • 민선규;최명진
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 추계학술대회 논문집
    • /
    • pp.591-595
    • /
    • 1997
  • In analysis of piping vibration of petrochemical plant, the forcing functions mainly depend upon the equipment working mechanism and vibration resources in the piping systems. In general, harmonic function is used for the system with rotary equipments. Mechanical driving frequencies, wave functions, and response spectrum are used for reciprocating compressors, surge vibration of long transfer piping, and seismic/wind vibration, respectively. In this study, for the spray injection case inside the pipe, forcing function was modeled, in which two different fluids are distributed uniformly. To confirm the results, the scheme used for the forcing function was applied for real piping system. The vibration mode of the real system was consistent with the 4th mode obtained by simulation using the forcing function formulated in this study.

  • PDF

LED 구동전류의 피크값이 저감된 전해 커패시터 없는 AC-DC 컨버터 (AC-DC Converter for Electrolytic Capacitor-less LED Driver with Reduced LED Peak Current)

  • 강경숙;박권식;서병준;노의철
    • 전력전자학회논문지
    • /
    • 제23권1호
    • /
    • pp.59-65
    • /
    • 2018
  • A new single-stage flyback power converter with PFC for electrolytic capacitor-less LED driver is proposed in this study. This method minimizes the peak-to-average ratio of the LED driving pulsating current by adding the LED driving current near the LED current valley area, as well as the third harmonic component injection into the input current. The reduced peak current value of the LED drive current minimizes the thermal stress of the LED itself, thereby increasing the reliability of the LED, as well as achieving a long lifetime. Simulation and experimental results show the usefulness of the proposed topology.

석유화학 플랜트에서 배관 가진 함수의 시뮬레이션에 관한 연구 (A Simulation of Forcing Function for the Piping Vibration in Petrochemical Plants)

  • 민선규;최명진;김경훈
    • 한국시뮬레이션학회논문지
    • /
    • 제10권4호
    • /
    • pp.1-10
    • /
    • 2001
  • For the simulation of piping vibrations in petrochemical plants, forcing functions mainly depend upon the equipment working mechanism and vibration resources in the piping systems. In general, harmonic function is used to simulate rotary equipment. Mechanical driving frequencies, wave functions, and response spectrum are used to simulate reciprocating compressors, surge vibration of long transfer piping, and seismic/wind vibration, respectively. In this study, the general suggestions for forcing functions were reviewed and proposed the forcing function to simulate the spray injection system inside the pipe in which two different fluids are distributed uniformly. To confirm the results, the scheme was applied for a real piping system. The vibration mode of the real system was consistent with the 4th mode (26.725 Hz) obtained by simulation using the forcing function presented in this study.

  • PDF

전류주입에 의한 전기추진시스템의 고조파 저감 (Harmonic Reduction of Electric Propulsion System by Current Injection)

  • 김종수;한원희;서동환
    • 해양환경안전학회지
    • /
    • 제18권4호
    • /
    • pp.360-364
    • /
    • 2012
  • 전기추진시스템 분야에서 AC/DC 컨버터는 상대적으로 간단한 다이오드 소자를 이용하는 정류기가 가장 널리 사용되고 있으며 이 정류기는 입력 전류에 큰 고조파를 포함하고 있어서 고조파 저감을 위한 많은 연구가 진행되고 있다. 본 연구에서 제안된 방식은 다이오드 정류기의 출력 전류를 정류기와 추진전동기 입력측에 주입하여 정류기와 추진전동기 입력 전류에 포함되는 고조파 성분을 줄이고 또한, 와이-델타 변압기를 정류기 및 추진전동기 입력회로에 설치되는 전류주입장치의 분배회로에 사용하여 주입전류와 전원 및 부하를 서로 절연함으로써 전류파형 개선과 전기적 안전성을 확보하였다. 제안한 방법을 현재 사용 중인 전기추진선박에서 적용하여 시뮬레이션 하였으며 기존의 전력변환장치와 비교하여 그 타당성을 입증하였다.

Shunt Active Filter for Multi-Level Inverters Using DDSRF with State Delay Controller

  • Rajesh, C.R.;Umayal, S.P.
    • Journal of Power Electronics
    • /
    • 제18권3호
    • /
    • pp.863-870
    • /
    • 2018
  • The traditional power control theories for the harmonic reduction methods in multilevel inverters are found to be unreliable under unbalanced load conditions. The unreliability in harmonic mitigation is caused by voltage fluctuations, non-linear loads, the use of power switches, etc. In general, the harmonics are reduced by filters. However, such devices are an expensive way to provide a smooth and fast response to secure power systems during dynamic conditions. Hence, the Decoupled Double Synchronous Reference Frame (DDSRF) theory combined with a State Delay Controller (SDC) is proposed to achieve a harmonic reduction in power systems. The DDSRF produces a sinusoidal harmonic that is the opposite of the load harmonic. Then, it injects this harmonic into power systems, which reduces the effect of harmonics. The SDC is used to reduce the delay between the compensation time for power injection and the generation of a reference signal. The proposed technique has been simulated using MATLAB and its reliability has been verified experimentally under unbalanced conditions.