• Title/Summary/Keyword: Harmonic field

Search Result 452, Processing Time 0.024 seconds

Finite Element Method using Complex Harmonics for analyzing saturation characteristics (포화 특성 해석을 위한 복소 고조파 유한 요소해석법)

  • Chung, Yong-Seek;Park, Gwan-Soo;Hahn, Song-Yop
    • Proceedings of the KIEE Conference
    • /
    • 1990.07a
    • /
    • pp.11-14
    • /
    • 1990
  • The Complex Harmonic Balance Finite Element Method CHBFEM ) is dicussed for the time - periodic magnetic field with saturation characteristics. And Jw - method which is used for analyzing liner system with sinusoidal voltage input can be generalized in nonlinear time-periodic magnetio field system. The CHBFEM enables us to calculate the each harmonic magnetic flux ditribution and the distortion of currents resulting from material at an AC voltage source and to save calculating time, the number of calculation and computer memory.

  • PDF

Simultaneous Unwrapping Phase and Error Recovery from Inhomogeneity (SUPER) for Quantitative Susceptibility Mapping of the Human Brain

  • Yang, Young-Joong;Yoon, Jong-Hyun;Baek, Hyun-Man;Ahn, Chang-Beom
    • Investigative Magnetic Resonance Imaging
    • /
    • v.22 no.1
    • /
    • pp.37-49
    • /
    • 2018
  • Purpose: The effect of global inhomogeneity on quantitative susceptibility mapping (QSM) was investigated. A technique referred to as Simultaneous Unwrapping Phase with Error Recovery from inhomogeneity (SUPER) is suggested as a preprocessing to QSM to remove global field inhomogeneity-induced phase by polynomial fitting. Materials and Methods: The effect of global inhomogeneity on QSM was investigated by numerical simulations. Three types of global inhomogeneity were added to the tissue susceptibility phase, and the root mean square error (RMSE) in the susceptibility map was evaluated. In-vivo QSM imaging with volunteers was carried out for 3.0T and 7.0T MRI systems to demonstrate the efficacy of the proposed method. Results: The SUPER technique removed harmonic and non-harmonic global phases. Previously only the harmonic phase was removed by the background phase removal method. The global phase contained a non-harmonic phase due to various experimental and physiological causes, which degraded a susceptibility map. The RMSE in the susceptibility map increased under the influence of global inhomogeneity; while the error was consistent, irrespective of the global inhomogeneity, if the inhomogeneity was corrected by the SUPER technique. In-vivo QSM imaging with volunteers at 3.0T and 7.0T MRI systems showed better definition in small vascular structures and reduced fluctuation and non-uniformity in the frontal lobes, where field inhomogeneity was more severe. Conclusion: Correcting global inhomogeneity using the SUPER technique is an effective way to obtain an accurate susceptibility map on QSM method. Since the susceptibility variations are small quantities in the brain tissue, correction of the inhomogeneity is an essential element for obtaining an accurate QSM.

Vital Sign Sensor Based on Second Harmonic Frequency Drift of Oscillator (발진기의 2채배 고조파 주파수 천이를 이용한 생체신호 측정센서)

  • Ku, Ki-Young;Hong, Yunseog;Lee, Hee-Jo;Yun, Gi-Ho;Yook, Jong-Gwan;Kim, Kang-Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.3
    • /
    • pp.299-306
    • /
    • 2016
  • In this paper, a vital sign sensor based on impedance variation of resonator is proposed to detect the respiration and heartbeat signals within near-field range as a function of the separation distance between resonator and subject. The sensor consists of an oscillator with a built-in planar type patch resonator, a diplexer for only pass the second harmonic frequency, amplifier, SAW filter, and RF detector. The cardiac activity of a subject such as respiration and heartbeat causes the variation of the oscillation frequency corresponding impedance variation of the resonator within near-field range. The combination of the second harmonic oscillation frequency deviation and the superior skirt frequency of the SAW filter enables the proposed sensor to extend twice detection range. The experimental results reveal that the proposed sensor placed 40 mm away from a subject can reliably detect respiration and heartbeat signals.

Loss characteristics analysis of HTS DC cable using FEM (FEM을 이용한 초전도 직류 케이블의 손실 특성 분석)

  • Kim, Sung-Kyu;Kim, Seok-Ho;Kim, Jin-Geun;Park, Min-Won;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.822-823
    • /
    • 2011
  • The authors analyzed harmonic current based loss of a high temperature superconducting (HTS) DC model cable. The loss in HTS DC cable is generated due to the variation of magnetic field caused by harmonic current in a HVDC transmission system. The authors designed and fabricated two meters of HTS DC model cable for verification of real loss characteristic. In this paper, the loss characteristics caused by harmonic current in the HTS DC model cable are analyzed using commercial finite element method software package. The loss of the HTS DC cable is much less than the loss of the HTS AC cable but the loss should be considered to decide a proper capacity of cooling system.

  • PDF

Reconfigurable Selective Harmonic Elimination Technique for Wide Range Operations in Asymmetric Cascaded Multilevel Inverter

  • Kavitha, R;Rani, Thottungal
    • Journal of Power Electronics
    • /
    • v.18 no.4
    • /
    • pp.1037-1050
    • /
    • 2018
  • This paper presents a novel reconfigurable selective harmonic elimination technique to control harmonics over a wide range of Modulation Indexes (MI) in Multi-Level Inverter (MLI). In the proposed method, the region of the MI is divided into various sectors and expressions are formulated with different switching patterns for each of the sectors. A memetic BBO-MAS (Biogeography Based Optimization - Mesh Adaptive direct Search) optimization algorithm is proposed for solving the Selective Harmonic Elimination - Pulse Width Modulation (SHE-PWM) technique. An experimental prototype is developed using a Field Programmable Gate Array (FPGA) and their FFT spectrums are analyzed over a wide range of MI using a fluke power logger. Simulation and experimental results have validated the performance of the proposed optimization algorithms and the reconfigurable SHE-PWM technique. Further, the sensitivity of the harmonics has been analyzed considering non-integer variations in the magnitude of the input DC sources.

Real time Implementation of SHE PWM in Single Phase Matrix Converter using Linearization Method

  • Karuvelam, P. Subha;Rajaram, M.
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.4
    • /
    • pp.1682-1691
    • /
    • 2015
  • In this paper, a real time implementation of selective harmonic elimination pulse width modulation (SHEPWM) using Real Coded Genetic Algorithm (RGA), Particle Swarm Optimization technique (PSO) and a new technique known as Linearization Method (LM) for Single Phase Matrix Converter (SPMC) is designed and discussed. In the proposed technique, the switching frequency is fixed and the optimum switching angles are obtained using simple mathematical calculations. A MATLAB simulation was carried out, and FFT analysis of the simulated output voltage waveform confirms the effectiveness of the proposed method. An experimental setup was also developed, and the switching angles and firing pulses are generated using Field Programmable Gate Array (FPGA) processor. The proposed method proves that it is much applicable in the industrial applications by virtue of its suitability in real time applications.

Analysis of Magnetic Field and Thrust in Slotless Permanent Magnet Linear Synchronous Motor using 3D Space Harmonic Analysis Method (3차원 공간고조파법을 이용한 슬롯리스형 영구자석 선형 동기전동기의 자계 및 추력특성 해석)

  • Lee, Ju-Min;Kang, Gyu-Hong;Hong, Jung-Pyo;Kim, Gyu-Tak
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.6
    • /
    • pp.255-262
    • /
    • 2001
  • This paper deals with characteristic analysis method of the slotless type Permanent Magnet Linear Synchronous Motor(PMLSM) using the space harmonic method. Analysis models of the PM and the armature current are described by the magnetization configurations taking into account the 2D and 3D distribution. In 3D analysis, the thrust and normal force can be calculated more accurately, because it can consider the z component flux density which is impossible in 2D analysis. In order to verify the validity of the proposed method, the results of the analytic method are compared with not only the experimental ones but ones of Finite Element Method(FEM).

  • PDF

Analysis and simulation of Cascaded H-bridge 7 level inverter for eliminating typical harmonic waveforms (특정 고조파 제거를 위한 Cascaded H-bridge 7레벨 인버터의 특성해석 및 시뮬레이션)

  • Jin, Sun-Ho;Oh, Jin-Suk;Jo, Kwan-Jun;Kwak, Jun-Ho;Lim, Myoung-Kyu;Kim, Jang-Mok
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.06a
    • /
    • pp.1022-1028
    • /
    • 2005
  • This paper is presented the analysis results and simulation results of cascaded H-bridge 7 level inverter with various modulation index. Stepped waveform having number of switching was used to eliminate harmonic components. Switching angles according to modulation index are calculated numerically. Therefore, 3 times of switching with 7 level topology and QWS(Quarter Wave Symmetry) could eliminate 5th and 7th harmonics. The harmonic characteristics are compared to those of space vector modulation method which known as common modulation method in industrial field. Stepped waveform method showed higher ability to reduce, especially lower order of harmonics.

  • PDF

Efficient Second Harmonic Generation of Pulsed Nd-YAG Laser Radiation with Noncritically Phase-Matchable $LiNbO_3$ in Room-Temperature

  • Jong-Soo Lee;Bong-Hoon Kang;Bum Ku Rhee;Chong-Don Kim;Gi-Tae Joo
    • The Korean Journal of Ceramics
    • /
    • v.6 no.3
    • /
    • pp.206-208
    • /
    • 2000
  • 0.65 mol% MgO-doped LiNbO$_3$single crystals were grown by CZ method. The obtained single crystals were colorless and transparent. Noncritically phase-matched second harmonic generation (SHG) of 532-nm radiation from 1064-nm in MgO-doped LiNbO$_3$has been investigated by using pulsed Nd:YAG laser. The phase-matching temperature was room temperature. SHG conversion efficiencies were typically achieved higher than 50% at the phase-matching temperature with no photorefractive damage in the region of fundamental power density which was used in this experiment. The thermo-birefringence coefficient and the electro-birefringence coefficient of SHG were calculated from the temperature phase-matching profile with the electric field.

  • PDF

Third-Harmonic Generation Microscopy for Material Characterization

  • Royon, Arnaud;Bousquet, Bruno;Canioni, Lionel;Treguer, Mona;Cardinal, Thierry;Fargin, Evelyne;Kim, Dae-Geun;Park, Seung-Han
    • Journal of the Optical Society of Korea
    • /
    • v.10 no.4
    • /
    • pp.188-195
    • /
    • 2006
  • Third harmonic generation microscopy is described in the frame work of the theory of harmonic generation with Gaussian focused beams inside a bulk material as well as at the vicinity of an interface. This model is then applied to characterize different types of materials in terms of electronic third-order susceptibility. Examples of bulk glasses, poled glasses, laser-induced modifications in glasses and nanoparticles in solution are given in order to give a survey of the broad application field of THG microscopy in material characterization.