• Title/Summary/Keyword: Harmonic estimation

Search Result 160, Processing Time 0.027 seconds

A New Assessment for the Total Harmonic Contributions at the Point of Common Coupling

  • Han, Jong-Hoon;Lee, Kyebyung;Song, Chong Suk;Jang, Gilsoo;Byeon, Gilsung;Park, Chang-Hyun
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.6-14
    • /
    • 2014
  • A new method to determine the total harmonic contributions of several customers and the utility at the point of common coupling is presented. The proposed method can quantify the individual harmonic impact of each suspicious harmonic source at the point of common coupling. The individual harmonic impact index is then used to assess the total harmonic contribution of each harmonic source. This index can be calculated by the results processed from instantaneous harmonic voltage and current phasor values. The results demonstrate the performance of the proposed method in terms of steady-state accuracy and response to time-varying operating conditions. The proposed index can be used for billing purposes to control harmonic distortion levels in power systems.

Efficient Harmonic-CELP Based Low Bit Rate Speech Coder (효율적인 하모닉-CELP 구조를 갖는 저 전송률 음성 부호화기)

  • 최용수;김경민;윤대희
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.5
    • /
    • pp.35-47
    • /
    • 2001
  • This paper describes an efficient harmonic-CELP speech coder by taking advantages of harmonic and CELP coders into account. According to frame voicing decision, the proposed harmonic-CELP coder adopts the RP-VSELP coder as a fast CELP in case of an unvoiced frame, or an improved harmonic coder in case of a voiced frame. The proposed coder has main features as follows: simple pitch detection, fast harmonic estimation, variable dimension harmonic vector quantization, perceptual weighting reflecting frequency resolution, fast harmonic synthesis, naturalness control using band voicing, and multi-mode. These features make the proposed coder require very low complexity, compared with HVXC coder To demonstrate the performance of the proposed coder, a 2.4 kbps coder has been implemented and compared with reference coders. From results of informal listening tests, the proposed coder showed good quality while requiring low delay and complexity.

  • PDF

Optimal Placement of Measurements using Genetic Algorithms for Harmonic State Estimation (고조파 상태 추정에 있어서 유전 알고리즘을 이용한 최적 측정위치 선정)

  • Chung, H.H.;Wang, Y.P.;Lee, J.P.;Park, H.C.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.298-300
    • /
    • 2002
  • The design of a measurement system to perform Harmonic State Estimation (HSE) is a very complex problem. In particular, the number of available harmonic instruments(Continuous Harmonic Analysis in Real Time : CHART) is always limited. Therefore, a systematic procedure is needed to design the optimal placement of measurement points. This paper presents a new HSE algorithm which is based on an optimal placement of measurement points using Genetic Algorithms (GAs). This HSE has been applied to the New Zealand AC Power System for the validation of the new HSE algorithm. The study results have indicated an economical and effective method for optimal placement of measurement points using GAs in the HSE.

  • PDF

An Optimal Algorithm of Harmonic State Estimation using Immune Algorithm on Power System (IA를 이용한 전력시스템 고조파 상태 추정 최적 알고리즘)

  • Park, I.P.;Wang, Y.P.;Chung, H.H.;Park, H.C.;Ahn, B.C.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.92-94
    • /
    • 2003
  • The design of a measurement system to perform Harmonic State Estimation(HSE) is a very complex problem. In particular, the number of available harmonic instruments (Continuous Harmonic Analysis in Real Time : CHART) is always limited. Therefore, a systematic procedure is needed to design the optimal placement of measurement points. This paper presents an optimal algorithm of HSE which is based on an optimal placement of measurement points using Immune Algorithm (IAs). This HSE has been applied to power system for the validation of an optimal algorithm of HSE. The study results have indicated an economical and effective method for optimal placement of measurement points using IAs in the HSE.

  • PDF

Harmonic Estimation of Power Signal Based on Time-varying Optimal Finite Impulse Response Filter (시변 최적 유한 임펄스 응답 필터 기반 전력 신호 고조파 검출)

  • Kwon, Bo-Kyu
    • The Journal of Korean Institute of Information Technology
    • /
    • v.16 no.11
    • /
    • pp.97-103
    • /
    • 2018
  • In this paper, the estimation method for the power signal harmonics is proposed by using the time-varying optimal finite impulse response (FIR) filter. To estimate the magnitude and phase-angle of the harmonic components, the time-varying optimal FIR filter is designed for the state space representation of the noisy power signal which the magnitude and phase is considered as a stochastic process. Since the time-varying optimal FIR filter used in the proposed method does not use any priori information of the initial condition and has FIR structure, the proposed method could overcome the demerits of Kalman filter based method such as poor estimation and divergence problem. Due to the FIR structure, the proposed method is more robust against to the model uncertainty than the Kalman filter. Moreover, the proposed method gives more general solution than the time-invariant optimal FIR filter based harmonic estimation method. To verify the performance and robustness of the proposed method, the proposed method is compared with time-varying Kalman filter based method through simulation.

Improved Harmonic-CELP Speech Coder with Dual Bit-Rates(2.4/4.0 kbps) (이중 전송률(2.4/4.0 kbps)을 갖는 개선된 하모닉-CELP 음성부호화기)

  • 김경민;윤성완;최용수;박영철;윤대희;강태익
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.3C
    • /
    • pp.239-247
    • /
    • 2003
  • This paper presents a dual-rate (2.4/4.0 kbps) Improved Harmonic-CELP(IHC) speech coder based on the EHC(Efficient Harmonic-CELP) which was presented by the authors. The proposed IHC employs the harmonic coding for voiced and the CELP for unvoiced segments. In the IHC, an initial voiced/unvoiced estimate is obtained by the pitch gain and energy. Then, the final V/UV mode is decided by using the frame energy contour. A new harmonic estimation combining peak picking and delta adjustment provides a more reliable harmonic estimation than that in the EHC. In addition, a noise mixing scheme in conjunction with an improved band voicing measurement provides the naturalness of the synthesized speech. To demonstrate the performance of the proposed IHC coder, the coder has been implemented and compared with the 2.0/4.0 kbps HVXC(Harmonic excitation Vector Coding) standardized by MPEG-4. Results of subjective evaluation showed that the proposed IHC coder and produce better speech quality than the HVXC, with only 40% complexity of the HVXC.

FFT-Based Position Estimation in Switched Reluctance Motor Drives

  • Ha, Keunsoo;Kim, Jaehyuck;Choi, Jang Young
    • Journal of Magnetics
    • /
    • v.19 no.1
    • /
    • pp.90-100
    • /
    • 2014
  • Position estimation that uses only active phase voltage and current is presented, to perform high accuracy position sensorless control of a SRM drive. By extracting the amplitude of the first switching harmonic terms of phase voltage and current for a PWM period through Fast Fourier Transform (FFT), the flux-linkage and position are estimated without external hardware circuitry, such as a modulator and demodulator, which result in increased cost, as well as large position estimation error, produced when the motional back EMF is ignored near zero speed. A two-phase SRM drive system, consisting of an asymmetrical converter and a conventional closed-loop PI current controller, is utilized to validate the performance of the proposed position estimation scheme in comprehensive operating conditions. It is shown that the estimated values very closely track the actual values, in dynamic simulations and experiments.

Harmonic Current Compensation Method Using Inverter-Interfaced Distributed Generators (인버터 연계형 분산전원을 이용한 배전계통 고조파 전류 보상원리)

  • Chung, Il-Yop;Kang, Hyun-Koo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.2
    • /
    • pp.279-284
    • /
    • 2011
  • Harmonic distortions in current waveform may cause significant problems in electric power system facility and operation. This paper presents an adaptive parameter estimation method to detect harmonic current components caused by nonlinear loads. In addition, a coordination strategy for multiple inverter-interfaced distributed generators to compensate the harmonic currents is discussed. The coordination strategy is realized by distributing the harmonic compensation participation index to individual distributed generators. The harmonic compensation participation index can be determined by the amount of remaining power generation capacity of each distributed generator. Simulation results based on switching-level inverter models show that the proposed harmonic detection method has good performance and the coordination strategy can improve harmonic problems efficiently.

Speed Estimation of Induction Motor in Steady State Using the RSH (RSH를 이용한 정상상태 운전 유도전동기의 회전속도 추정)

  • Yang, Chul-Oh;Park, Kyu-Nam;Song, Myung-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.9
    • /
    • pp.1783-1787
    • /
    • 2011
  • The slip frequency is included in feature frequency for fault diagnosis of rotor bar, so rotating rotor speed is needed. In this study, rotor slot harmonic(RSH) method is suggested for speed estimation of induction motor. When the rotor is rotating, motor current signal include the harmonic signal of back-emf voltage related with number of rotor slot. So from the power spectrum of current signal, the rotor speed can be founded. This method of rotor speed estimation gives the slip frequency, and the feature frequency of rotor bar fault can be calculated. Comparing with stroboscope speed meter, the error rate of suggested method is less than 0.1[%].

PFC Dual Boost Converter Based on Input Voltage Estimation for DC Inverter Air Conditioner

  • Park, Gwi-Geun;Kwon, Kee-Yong;Kim, Tae-Woong
    • Journal of Power Electronics
    • /
    • v.10 no.3
    • /
    • pp.293-299
    • /
    • 2010
  • In this paper, a single-phase PFC (Power Factor Correction) dual boost converter based on input voltage estimation is studied for DC inverter air conditioner. It is focused on improving input power factor and power quality to satisfy the recent harmonic current regulation standards. Furthermore the input voltage estimation is introduced for price competitive products. A low cost and reasonable control system is implemented using a specified high-speed 32-bit microprocessor. Their effectiveness are verified through theoretical analysis and experiments.