• Title/Summary/Keyword: Harmonic currents

Search Result 343, Processing Time 0.03 seconds

Application of Oil Spill Model to the South Sea of Korea (누유확산 모델의 남해안 적용)

  • Hong Keyyong;Lee Moonjin
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.1 no.1
    • /
    • pp.56-65
    • /
    • 1998
  • An oil spill model, Green Sea Ranger(GSR) based on trajectory and fate modeling of spilt oil behavior is introduced. The various physical models on weathering processes are reviewed and those adopted by GSR are described. A database for currents, which is necessary for the real-time simulation of oil spill, is generated on the south sea of Korea. The real-time prediction of tidal currents in the South Sea of Korea is carried out. Four major constituents (M₂, S₂, K₁, O₁ tide) are employed in the prediction, and those angular speeds and phases are determined from the astronomical arguments. The harmonic constants of the constituents are computed by solving shallow-water tide equations. The GSR has user-freiendly GUI and flexible framework which makes it easy to expand the database for sea environments in Korean coastal waters. The GSR is validated by the simulation of O-Sung oil spill caused by a grounded oil tanker in coastal sea near Maemol-do. The simulated trajectory is compared with observed one and it is shown that the GSR gives reasonable estimation on spilt oil bahavior.

  • PDF

Oil Spill Behavior forecasting Model in South-eastern Coastal Area Of Korea (한국 동남해역에서의 유출유 확산예측모델)

  • Ryu Cheong Ro;Kim Jong Kyu;Seol Dong Guan;Kang Dong Uk
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.1 no.2
    • /
    • pp.52-59
    • /
    • 1998
  • Many concerns are placed on preservation of coastal environment from the spilled oil contaminant in the coastal area. And the use of computer simulation model to combat with oil spill has come to play mote important role in forecasting the oil spill trajectory so as to protect coastal area and minimize the damage from oil contaminants. The main concerns of this study is how the movements of spilled oil are affected by currents including tidal, oceanic, and wind-driven currents. Especially, in the present paper, the oil spill trajectory can be predicted by a real-time system that allows prediction of circulation and wind field. The harmonic methods are adopted to simulate the tidal currents as well as it can be possible to achieve the wind-field data and oceanic current data from the established database. System performance is illustrated by the simulation of oil spill in the south-eastern coastal area of Korea. Simulation results are compared with the observed one.

  • PDF

Tidal Current Characteristics around the Geomoondo Marine Afforestation (거문도 바다숲 조성해역의 해수유동 특성)

  • Jung, Jong-Ahm;Shin, Chun-Su;Kim, Jong-Kyu
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.18 no.1
    • /
    • pp.25-32
    • /
    • 2012
  • To arrange effectively artificial reefs for marine afforestation, tidal currents were analyzed by numerical experiments. The numerical experiments were carried out by EFDC(Environmental Fluid Dynamics Code), and water column was vertically divided 5 layers. Tidal current patterns showed to be affected by main current at outside of study area, and circle currents of two were observed from analysis of residual currents. The calculated harmonic constants of tide and tidal current agreed well with those of observations at two stations for tide and two stations for tidal current. The model successfully reproduced the tidal current around the Geomoondo marine afforestation. It suggest that artificial reefs for marine afforestation should be installed belt zone at study area.

A novel energy-efficient bridgeless boost AC to DC converter (효율을 고려한 새로운 AC/DC 컨버터)

  • Yoon, Kyoung-Kuk;Kim, Seong-Hwan;Kim, Deok-Ki
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.3
    • /
    • pp.223-227
    • /
    • 2016
  • Power supplies make the load compatible with its power source. DC power supplies are extensively used with most electrical and electronic appliances such as computers, television, and audio sets. The presence of non-linear loads results in a low power factor and higher harmonics in the power system. Several techniques for power-factor correction and harmonic reduction have been reported in the literature. This paper proposes a bridgeless boost converter that improves the power factor and reduces the harmonic content in input line currents as compared to full-bridge rectifiers. This bridgeless boost converter eliminates the need of a line-voltage bridge rectifier in conventional boost converter and thereby reduces conduction losses. The effectiveness of the proposed scheme is verified by computer simulations by using the PSIM software.

Harmonic Frequency Analysis of Interlocking System for Rolling Stock Operation in Electrical Railroads (전기철도 구간에서의 철도차량 운행에 따른 연동장치 고조파 분석)

  • Baek, Jong-Hyen;Kim, Yong-Kyu;Oh, Seh-Chan;Lee, Kang-Mi;Jo, Hyun-Jeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.8
    • /
    • pp.3610-3616
    • /
    • 2011
  • Electrical Railroads provide electric power, which can operate vehicles, via feeder wires. And the supplied current returns to the transformer substation through lines and ground net. The used load current depending on the operation of rail vehicles in the electric railway sections returns to the substation through a track which is a return circuit. The load current contains harmonics because of the power conversion equipment used in rolling stocks and such harmonic currents should not affect train control system. In this paper we present the test result in order to verify that the harmonics produced by the operation of rail vehicles in the newly built electric railway sections can affect interlocking systems. The test in question was performed in a linking section that trackside equipment under railway operating conditions and interlocking are linked in order to identify whether or not the interlocking fitted in a signal machine room can be affected by harmonics according to railway operation.

Hormonic Evaluation of An Imported IAT(Intra Airport Transit) System in Incheon International Airport (인천 국제공항청사 경전철 도입에 따른 고조파 영향 분석)

  • Kim, Jin-O;Song, Hak-Seon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.1
    • /
    • pp.41-47
    • /
    • 2006
  • This paper presents harmonic evaluation of an IAT(Intra Airport Transit) system in Incheon International Airport. It will be used for electric vehicles with 80[kW] per car produced by Mitsubishi Heavy Industries Ltd, and which is constructed with SIV(Static Inverter), VVVF controller and two induction motor. The vehicles operated in the IAT system can be treated as rapidly changing DC loat and at a feeding substation, 3-phase electric power is transferred to DC 750[V] by rectifier. Since vehicles are changing continuously, the voltages for the load fluctuate in the IAT system, and moreover, the voltage fluctuation generates high-order harmonics. It results the difficulty in maintaining power quality in KEPCO systems' side. The power quality of the IAT system in Incheon International Airport is evaluated using PSCAD/EMTDC simulator in the paper. The THD(Total Harmonic Distortion) of voltages and TDD(Total Demand Distortion) of currents, indices are calculated for the IAT system using the results of PSCAD/EMTDC dynamic simulation.

A Study on Series Active Power Filter Compensating Unbalanced Source Voltage in 3phase-3wire system (불평형 전원전압을 보상하는 3상3선식 직렬형 능동전력필터에 관한 연구)

  • 오재훈;한윤석;김영석;원충연;최세완
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.5
    • /
    • pp.386-393
    • /
    • 2001
  • A series active power filter compensating current harmonics and unbalanced source voltages in a 3phase-3wire power system is presented. The system is composed of series active power filter and shunt passive filters that are tuned at 5th and 7th harmonics. The proposed series active power filter improves harmonic compensation characteristics of the shunt passive filters, reduces source side harmonic currents and compensates the unbalanced source voltages. In the proposed algorithm, compensation voltage for harmonic reduction is calculated by a performance function, and compensation voltage for the unbalanced source voltage is calculated based on the synchronous reference frame. Some results obtained from the experimental model using the proposed method are Presented to demonstrate and confirm its validity.

  • PDF

A Five-Phase Induction Motor Speed Control System Excluding Effects of 3rd Current Harmonics Component

  • Kim, Min-Huei;Kim, Nam-Hun;Baik, Won-Sik
    • Journal of Power Electronics
    • /
    • v.11 no.3
    • /
    • pp.294-303
    • /
    • 2011
  • In this paper an effective five-phase induction motor (IM) and its drive methods are proposed. Due to the additional degrees of freedom, the five-phase IM drive presents unique characteristics for enhancing the torque producing capability of the motor. Also the five-phase motor drives possess many other advantages when compared to traditional three-phase motor drives. Some of these advantages include, reducing the amplitude and increasing the frequency of the torque pulsation, reducing the amplitude of the current without increasing the voltage per phase and increasing the reliability. In order to maximize the torque per ampere, the proposed motor has concentrated winding, the produced back electromotive force (EMF) is almost trapezoidal, and the motor is supplied with the combined sinusoidal plus the third harmonic of the currents. For demonstrating the superior performance of the proposed five-phase IM, the motors are also analyzed on the synchronously rotating reference frame. To supply trapezoidal current waveform and to exclude the effect of the $3^{rd}$ harmonic current, a new control stratagem is proposed. The proposed control method is based on direct torque control (DTC) and rotor flux oriented control (RFOC) of the five-phase IM drives. It is able to reduce the acoustical noise, the torque, the flux, the current, and the speed pulsations during the steady state. The DTC transient merits are preserved, while a better quality steady-state performance is produced in the five phase motor drive for a wide speed range. Experimental results clearly demonstrated a more dynamic steady state performance with the proposed control system.

Analysis of continuous conduction mode boost power-factor-correction circuit (부스트 방식 역률개선회로의 설계와 특성분석)

  • Kim, Cherl-Jin;Jang, Jun-Young;Kim, Sang-Duck;Song, Yo-Chang;Yoon, Shin-Yang
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1120-1122
    • /
    • 2002
  • Switching power supply are widely used in many industrial field. Power factor improvement and harmonic reduction technique is very important in switching power supply. The power factor correction (PFC) circuit using boost converter used in input of power source is studied in this paper. It is analyzed distortional situations and harmonics of input currents that presented at continuous conduction mode(CCM) of boost PFC circuit. It is done simulations of harmonics distribution according to load variation by using PSPICE and MATLAB. From the actual experiment of boost PFC circuit the validity of the analysis is confirmed.

  • PDF

Load Disturbance Compensation for Stand-alone Inverters Using an Inductor Current Observer

  • Choe, Jung-Muk;Moon, Seungryul;Byen, Byeng-Joo;Lai, Jih-Sheng;Lim, Young-Bae;Choe, Gyu-Ha
    • Journal of Power Electronics
    • /
    • v.17 no.2
    • /
    • pp.389-397
    • /
    • 2017
  • A control scheme for stand-alone inverters that utilizes an inductor current observer (ICO) is proposed. The proposed method measures disturbance load currents using a current sensor and it estimates the inductor current using the ICO. The filter parameter mismatch effect is analyzed to confirm the ICO's controllability. The ICO and controllers are designed in a continuous-time domain and transferred to a discrete-time domain with a digital delay. Experimental results demonstrate the effectiveness of the ICO using a 5-kVA single-phase stand-alone inverter prototype. The experimental results demonstrate that the observed current matches the actual current and that the proposed method can archive a less than 2.4% total harmonic distortion (THD) sinusoidal output waveform under nonlinear load conditions.