• 제목/요약/키워드: Harmonic current contents

검색결과 38건 처리시간 0.032초

환경조건에 따른 EPDM 고분자 애자의 누설전류파형과 스펙트럼 분석 (Leakage Current Waveforms and Spectrum Analysis of EPDM Polymer Insulator according to Environment Condition)

  • 박재준;김정부;송영철
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 춘계학술대회 논문집 방전 플라즈마 유기절연재료 초전도 자성체연구회
    • /
    • pp.82-86
    • /
    • 2004
  • This research is about the result of leakage current waveform about the situation of surface leakage current and environmental changes(Salt fog, clean fog and rain) by EPDM polymer insulators' amount of salt. The researcher presents the result of changing about fundamental harmonic, 3rd harmonic and 5th harmonic from starting point of supplying power to flashover. In this study, researched environmental affects (clean fog, salt fog and rain) about surface aging of polymer insulators and used frequency spectrum of leakage current waveform to develop the diagnostic technique of surface aging. When amount of salt contents changed, surface aging stage and the degree of aging (distortion factor) about 3rd and 5th harmonic waveform on low frequency harmonic wave. The distortion factor which is harmonic percentage about basic harmonic is important pointer to evaluate the surface condition of polymer insulators.

  • PDF

Novel Third Harmonic Current Injection Technique for Harmonic Reduction of Controlled Converters

  • Eltamaly, Ali M.
    • Journal of Power Electronics
    • /
    • 제12권6호
    • /
    • pp.925-934
    • /
    • 2012
  • Three-phase controlled converters have many applications in the utility interfacing of renewable energy sources and adjustable speed drives as a rectifier or inverter. The utility line currents of these converters have a high harmonic distortion, which is more than the harmonic standards. This paper introduces a new technique for circulating the third harmonic currents from the dc-link to the line currents to reduce their harmonic contents. The proposed system uses a single-phase PWM converter to control the angle and amplitude of the injection current for each of the firing angle of a three-phase converter. A detailed analysis is introduced to achieve a relationship between the firing angle of the three-phase controlled converter and the power angle of the PWM converter. In addition, a detailed design for the other injection path components is introduced. A simulation and experimental work is introduced to prove the mathematical derivations. Analysis, simulation and experimental results prove the superiority of the proposed technique.

A Study on High Current Rectifier Systems with Mitigated Time-Varying Magnetic Field Generation

  • 김창우;서용석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 하계학술대회 논문집
    • /
    • pp.232-233
    • /
    • 2010
  • This paper investigates occupational exposure to time-varying magnetic field generation in high power rectifier systems. Two different kinds of high power rectifier systems of 25kA are modeled and analyzed. The performance is compared and evaluated on the basis of exposure guidelines from ICNIRP. In order to focus on the qualitative effect of rectifier operation, the mechanical structure of current carrying conductors is simplified as infinite long bus-bar model and low frequency harmonic contents up to 65kHz are considered. Thyristor rectifier generates a significant amount of low frequency magnetic field harmonic contents both at ac and dc side of rectifier infringing the limit from ICNIRP. The multilevel rectifier-IGCT type has almost negligible field generation from ac input side and smaller harmonic contents in dc load side complying with ICNIRP guideline. This remarkable advantage of multilevel rectifier-IGCT type can lead to very simple site layout design for installation and cost-effective compliance to guideline of occupational exposure against magnetic field.

  • PDF

SALT FOG시 EPDM고분자애자의 누설전류파형과 스펙트럼분석 (Leakage Current Waveforms and Spectrum Analysis on Polymer Insulator of EPDM under Salt fog)

  • 박재준;양태규
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2004년도 춘계종합학술대회
    • /
    • pp.500-504
    • /
    • 2004
  • 본 연구에서는 EPDM 고분자애자의 염무량 변화(salt:l0g, 25g, 50g, deionized water: 1000g)에 따른 표면방전과 환경적인 변화(salt fog 및 clean fog 그리고 raim)에 대한 누설전류 파형의 결과를 알아보았다. 기본파 및 3고조파 그리고 5고조파의 변화양상을 과전초기로부터 섬락시에 이르기까지 나타내었다. 표면열화의 진단기법을 개발하기위해서 누설전류파형의 주파수 스펙트럼을 이용하였고, 고분자애자의 표면열화에대한 환경적인 영향(clean fog, salt fog, rain)을 연구 하였다. 염분량의 변화시 기본파에 대한 저주파 고조파인 3고조파 및 5고조파에 대한 백분율(왜곡도)의 변화를 이용하여 표면 열화상태 및 정도를 정량화(a standard capacity)하여 나타내었다. 기본파에 대한 고조파 백분율인 왜곡율은 고분자 애자의 표면조건을 평가하는데 필요한 지시자라는 사실을 알 수 있었다.

  • PDF

배전계통 PQM 시스템 구축 및 고조파전압 분석사례 (A Case of the Distribution Power System PQMS Construction & Harmonic Voltage Analysis)

  • 박용업;이건행
    • 조명전기설비학회논문지
    • /
    • 제24권9호
    • /
    • pp.108-117
    • /
    • 2010
  • The main contents of this paper are the PQM system construction case and distribution system harmonic voltage analysis. The PQM system has constructed by KEPCO in order to investigate power quality of distribution power system for new power quality standard of KEPCO. In result, we have confirmed that voltage harmonic measurement value of the high voltage contract customer 8 households is suitable the KEPCO harmonic standard tentative plan. And the voltage harmonic value of distribution line end side is not always more high than source side by harmonic current offset effect. In the future, acquired data by season, region, load from the PQMS will be used on the resonable harmonic standard enactment in KEPCO.

단상 AC/DC 승압형 컨버터를 이용한 피복 아크 용접기 역률 개선에 관한 연구 (A Study On Power Factor Correction of SMAW(shielded metal-arc welding) Using Single Phase AC/DC Boost Converter)

  • 유영진;김이훈;김준호;원충연;김영렬;이상용
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.556-559
    • /
    • 2001
  • In this paper, we proposed AC/DC boost converter to improve input current harmonic reduction in SMAW(shielded metal-arc welding). The proposed harmonic reduction with the boost converter design and the UC2854 integrated circuit which controls the converter, The topology of welding power supply is made of a pair of boost converter and welder half-bridge IGBT inverter. The voltage arc is modeled by a variable resistance in series with a voltage source. The results has been confirmed by PSIM simulation tool. The simulation results show that input at current is nearly sinusoidal with low harmonic contents and sinusoidal input current waveform at high power factor.

  • PDF

다단 H-브릿지 인버터의 입력전류특성(II) - 다중 변압기 결선에 의한 고조파 저감 (Line Current Characteristics of Multilevel H-Bridge Inverters: Part II - Harmonic Reduction with Multiple Transformer Windings)

  • 정승기
    • 전력전자학회논문지
    • /
    • 제13권3호
    • /
    • pp.237-245
    • /
    • 2008
  • 최근 중대용량의 교류전동기 구동에 다단 H-브릿지 인버터의 적용이 늘어나고 있다. 이 인버터의 주된 장점 중의 하나는 입력전류에 고조파성분이 적다는 것으로 이는 2차측이 다중의 위상이동 권선으로 이루어진 변압기를 사용함으로써 이루어진다. 본 논문은 다단 H-브릿지 인버터에 적용되는 위상이동 변압기의 권선 설계의 기본 방안과 입력전류 고조파의 이론적인 해석을 제시하고 있다. 위상이동 변압기를 다룬 I부에 이어 II부에서는 입력 선전류의 고조파 특성을 해석함으로써 고조파 제거를 위한 등간격 위상차 설정방식의 이론적 근거를 규명하였다.

An Investigation on Input Filter Design for Matrix Converters

  • Nguyen, Huu-Nhan;Dam, Duy-Hung;Lee, Hong-Hee
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.178-179
    • /
    • 2017
  • Input filter is an essential component in a practical matrix converter (MC) system to generate the sinusoidal input currents. However, the input filter causes a displacement angle between the input current of MC and the source current. In this paper, we investigate the input filter design for MCs by considering the displacement angles of the input current and the input voltage to guarantee high input power factor (IPF) operation as well as low input current harmonic contents. Simulation results are provided to validate the input filter design with near unity input power factor and low total harmonic distortion (THD) of the input current.

  • PDF

R-L 부하에 대한 교류전류 제어방식 (A.C. current control scheme for R-L load)

  • 박민호;최규하
    • 전기의세계
    • /
    • 제29권12호
    • /
    • pp.791-797
    • /
    • 1980
  • This paper is concerned with the study of improving the faults of phase control scheme and suggesting a new approach to the control of load circuit with AC source. AC current control can restrict the magnitude of current within the given upper and lower current and make current continuous during every cycle. Also the harmonic contents of current can be greatly reduced using this control scheme. Analog computer and digital computer simulations reveal that the current control scheme is superior to the phase control scheme in controlling the power supply to the load R-L. Experimintal results demonstrate the feasibility and verify the operation of current controlled system.

  • PDF

Harmonic Winding Factors and MMF Analysis for Five-phase Fractional-slot Concentrated Winding PMSM

  • Kang, Huilin;Zhou, Libing;Wang, Jin
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제3권1호
    • /
    • pp.20-26
    • /
    • 2014
  • To enhance torque density by harmonic current injection, optimal slot/pole combinations for five-phase permanent magnet synchronous motors (PMSM) with fractional-slot concentrated windings (FSCW) are chosen. The synchronous and the third harmonic winding factors are calculated for a series of slot/pole combinations. Two five-phase PMSM, with general FSCW (GFSCW) and modular stator FSCW (MFSCW), are analyzed and compared in detail, including the stator structures, star of slots diagrams, and MMF harmonic analysis based on the winding function theory. The analytical results are verified by finite element method, the torque characteristics and phase back-EMF are also taken into considerations. Results show that the MFSCW PMSM can produce higher average torque, while characterized by more MMF harmonic contents and larger ripple torque.