Abstract

Recently, multilevel H-bridge inverters have become popular in medium to high power ac drive applications. One of significant advantages of them is low harmonic contents in their input line currents thanks to the transformer with multiple phase-shifted secondary windings. This paper attempts to provide basic guidelines for the design of the phase shifting transformer windings and theoretical analysis of input line current harmonics of H-bridge inverters. The part II is devoted to the analysis of the harmonic characteristics of the input line current, providing mathematical background for the equidistant phase-shifting angle distribution policy for harmonic elimination.

최근 중대용량의 교류전동기 구동에 다단 H-브릿지 인버터의 적용이 늘어나고 있다. 이 인버터의 주된 장점 중의 하나는 입력전류에 고조파성분이 적다는 것으로 이는 2차측이 다중의 위상이동 권선으로 이루어진 변압기를 사용함으로써 이루어진다. 본 논문은 다단 H-브릿지 인버터에 적용되는 위상이동 변압기의 권선 설계의 기본 방안과 입력전류 고조파의 이론적인 해석을 제시하고 있다. 위상이동 변압기를 다룬 I부에 이어 II부에서는 입력 선전류의 고조파 특성을 해석함으로써 고조파 제거를 위한 등간격 위상차 설정방식의 이론적 근거를 규명하였다.

Keywords

References

  1. Peter W. Hammond, US Patent 5,625,545, 1997
  2. Murray R. Spiegel, Mathematical Handbook of Formulas and Tables, Schaum's Outline Series