• 제목/요약/키워드: Harmonic contamination

검색결과 8건 처리시간 0.033초

환경조건의 변화에 따른 EPDM 애자의 표면 오손정도의 진단기술 (Diagnosis Technique of Surface Contamination Degree for EPDM Insulator according to Variation of Environment Condition)

  • 박재준;최인혁;김정부
    • 한국전기전자재료학회논문지
    • /
    • 제17권10호
    • /
    • pp.1132-1141
    • /
    • 2004
  • The waveforms of the leakage currents for the surface discharge according to the degree of salt contamination and the variation of environmental condition on the EPDM polymer insulators, were shown in this paper. The variation phenomena of fundamental wave, 3rd and 5th harmonic waveforms were also shown from the beginning of the applied voltage and to the flashover voltage. To develop the technique of percentage contamination degree of EPDM polymer insulator according to the variation of environmental condition, the distortion degree of 3rd and 5th harmonic wave to the fundamental wave was utilized through the spectrum analysis for the waveforms of leakage current in the simulation of salt and fog test. The fact that distortion degree % of 3rd and 5th harmonics for fundamental wave is a necessary indicator for the assessment of contamination degree for the polymer insulators, was known.

Design and Implementation of a Robust Predictive Control Scheme for Active Power Filters

  • Han, Yang;Xu, Lin
    • Journal of Power Electronics
    • /
    • 제11권5호
    • /
    • pp.751-758
    • /
    • 2011
  • This paper presents an effective robust predictive control scheme for the active power filter (APF) using a smith-predictor based current regulator, which show superior features when compared to proportional-integral (PI) controllers in terms of an enhanced closed-loop bandwidth and an improved current tracking accuracy. A moving average filter (MAF) is implemented using a field programmable gate array (FPGA) for signal pre-processing to eliminate the switching ripple contamination. An adaptive linear neural network (ADALINE) is used for individual harmonic estimation to achieve selective compensation purpose. The effectiveness and validity of the devised control algorithm are confirmed by extensive simulation and experimental results.

열화된 고분자애자의 카올린 오손에따른 표면방전특성 (Characteristics Leakage Current of Surface Discharge according to Kaolin Contamination by Deteriorated Polymer Insulators)

  • 박재준;가평현;서의원;정명연;김희동;송일근
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.2
    • /
    • pp.1100-1103
    • /
    • 2004
  • The paper presents the results of using the fundamental and the low frequency harmonic components of leakage current to study aging of EPDM insulator for contaminated condition by kaolin. The largeer the leakage current during 200ms, the higher harmonic component at 60hz. The harmonic component at 60hz and the odd order harmonics is increase relation without Kaolin Conent. Arcing on the surface was always associated with distortion in the leakage current; hence the low frequency components of the leakage currnent can be used as a means to evaluate the surface degration. Both the fundamental and 3rd & 5th harmonics increase dry-band activity.

  • PDF

옥외용 고분자 절연물의 표면 열화진단을 위한 아크파형 분석 (The Analysis of Arc Waveform for determing Surface Ageing of Polymeric Insulator for Out Door)

  • 문중섭;서광석;김정호;이재형;송우창;박용관
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2405-2407
    • /
    • 1999
  • In recent, the application of polymeric insulators for outdoor is significantly increasing. These materials have shown good performance in service, but had disadvantages under long-term exposure to contamination and moisture, resulting in some problems. Thus, this study concentrated on the development of technique evaluating the insulating status. Experiment was referred to lEC publ. 587, with data aquisition system to monitor leakage current. The components of leakage current investigated were waveform and 3rd harmonic. FFT was conducted for the analysis of harmonic components. The distortion of waveform with application time of voltage was evident, and so the 3rd harmonic component.

  • PDF

여러 환경조건에 대한 고분자애자의 누설전류 특성 변화 (Variation in Leakage Current Characteristics of Polymer Insulator for Various Environmental Condition)

  • 박재준;최인혁;이동일
    • 한국전기전자재료학회논문지
    • /
    • 제19권2호
    • /
    • pp.169-175
    • /
    • 2006
  • This study investigated variation leakage current maximum value and waveform considering applied voltage phase angel by simulating three environmental conditions, such as fog, salt fog, and kaolin contamination .As the result of applied voltage phase angel characteristics, leakage currents presented almost in phases in the early stage regardless of environmental conditions just after applying the voltage, and the phase of leakage currents certain phase lags for the discharge of the applied voltage when surface discharges occurred due to the continuous environmental contamination. In addition, the difference in phase significantly increased according to the intensity of discharges. The change in distortion rates according to the environmental contamination presented a nearly same level just after applying the voltage. The distortion rate of third harmonic for the fundamental wave presented by the order of fog>salt fog>kaolin when surface discharges occurred due to the applied voltage for certain continued periods. In the case of the fog and salt fog, the scale of spectrums decreased according to the increase in frequencies from the results of the analysis of high frequencies. In addition, the even number frequency presented a relatively large level compared to the odd number frequency under the kaolin contamination.

고속전자밸브를 사용한 유압시스템의 안정성 해석에 관한 연구 (A Study on Stability Analysis of Hydraulic System Using High Speed On-Off Valves)

  • 유태재
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제27권3호
    • /
    • pp.412-420
    • /
    • 2003
  • This study describes the merits of PWM control of hydraulic system using high speed on-off valves. Generally, Electro-hydraulic valves can be classified into two classification: valves which are controlled by analog signal and which are controlled by digital. The former includes hydraulic servo valves and proportional valves which require A/D converters as interface to digital computer and too costly and sensitive to oil contamination because of complexity in structures. The latter includes high speed on-off valves which do not require A/D converters because they are normally operated in a pulse width modulation(PWM) method, and are low in price and robust to oil contamination because of their simple structures. The objectives of this study is to analyze the limit cycle which regularly appear in the position control system using 2/2way high speed on-off valves and to give a criterion for the stability of this system. The nonlinear characteristics of PWM and cylinder friction of this system are described by harmonic linearization and the effects of parameter variations to the system stability are simulated.

EPDM 고분자 애자에 대한 표면방전 및 누설전류파형의 고조파분석 (Harmonics Analysis of Leakage Current Waveforms and Surface Discharge for EPDM Polymer Insulator)

  • 박재준;양태규
    • 한국전기전자재료학회논문지
    • /
    • 제17권9호
    • /
    • pp.1013-1021
    • /
    • 2004
  • This paper presents the results of spectrum analysis of leakage current waveforms on contaminated polymer insulators under fog conditions. This is a basic study on development of a monitoring for aging degree and surface pollution state using distortion rate(%) of 3rd and 5th harmonics according fundamental frequency[60Hz] under environment conditions. Arcing on the surface was always associated with distortion in the leakage current ; hence the low frequency components of the leakage current can be used as a means to evaluate the surface degradation. The results indicate that the distortion rate by spectrum analysis is available for the monitoring of contamination condition of EPDM Polymer insulators.

Plasma Impedance Monitoring with Real-time Cluster Analysis for RF Plasma Etching Endpoint Detection of Dielectric Layers

  • 장해규;채희엽
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제45회 하계 정기학술대회 초록집
    • /
    • pp.123.2-123.2
    • /
    • 2013
  • Etching endpoint detection with plasma impedance monitoring (PIM) is demonstrated for small area dielectric layers inductive coupled plasma etching. The endpoint is determined by the impedance harmonic signals variation from the I-V monitoring system. Measuring plasma impedance has been examined as a relatively simple method of detecting variations in plasma and surface conditions without contamination at low cost. Cluster analysis algorithm is modified and applied to real-time endpoint detection for sensitivity enhancement in this work. For verification, the detected endpoint by PIM and real-time cluster analysis is compared with widely used optical emission spectroscopy (OES) signals. The proposed technique shows clear improvement of sensitivity with significant noise reduction when it is compared with OES signals. This technique is expected to be applied to various plasma monitoring applications including fault detections as well as end point detection.

  • PDF