• Title/Summary/Keyword: Harmonic Resonance

Search Result 258, Processing Time 0.035 seconds

A Development of Simulator to Assessment for Loss Saving of Harmonic Electric Power Energy (고조파 전력에너지의 손실절감량 산정 시뮬레이터 개발)

  • Kim, Yong-Ha;Jo, Hyun-Mi;Heo, Dong-Ryeol;Park, Jong-Min;Park, Hwa-Yong;Yoo, Jeong-Hui
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1272-1273
    • /
    • 2011
  • A study on demonstration to development of simulator to assessment for loss saving of harmonic electric power energy. harmonic occurs to electric equipment like increase of terminal voltage, resonance phenomena occurrence and noise. To circulate of loss saving of harmonic electric power energy, we assessment electric power loss saving by harmonic and estimate loss saving of far-infrared radiation panel heating system.

  • PDF

Harmonic Analysis of Reactor and Capacitor in Single-tuned Harmonic Filter Application

  • Kim, Jong-Gyeum;Park, Young-Jeen;Lee, Dong-Ju
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.2
    • /
    • pp.239-244
    • /
    • 2011
  • Industrial power distribution system includes many kinds of non-linear loads, which produce the harmonics during energy conversion transition. The single-tuned passive filter is widely used to absorb the harmonics and attenuate its undesirable effect in the distribution system. However, the passive filter might be severely stressed, and sometimes even damaged, due to the absorption of harmonics. There is voltage rise on the capacitor when the single-turned harmonic filter is applied. When the capacitor voltage rose above the allowable limit, the expected life of the capacitor will considerably deteriorate. On the other hand, the reactor can experience the spike voltage even if the voltage and current of the capacitor are within the allowable limit, and this accumulated voltage stress of the reactor causes its premature fault. In this paper, we analyzed and compared the harmonic voltage and current of the reactor and capacitor in a single-tuned harmonic filter through the EMTP software and verified them with the experimental results.

New Control Strategy for Conventional VSI in Islanded Microgrid to Enhance Voltage Quality under Nonlinear Loads

  • Dam, Duy-Hung;Lee, Hong-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.351-352
    • /
    • 2015
  • This paper proposed a new control strategy for voltage source inverter (VSI) of effective fifth and seventh harmonic reduction in the point of common coupling (PCC) in islanded microgrid under nonlinear load without any additional hardware devices. The non-linear load regularly causes such harmonic distortion, which harmfully affect the performance of other loads or other distributed generation (DG) sources connect to the PCC. In order to improve the quality of delivered output voltage, these harmonic must be rejected. The proposed control strategy is developed based on the current controller formed by resonant controller parallel with a proportional integral controller, which perform on the fundamental reference frame. The reference current is estimated based on the voltage harmonic and the injecting power. The simulation and experimental results are shown to verify the effectiveness of proposed control method.

  • PDF

Design and Application of Harmonic Passive Filter (고조파 수동필터의 설계 및 적용)

  • Jeon, Jeong-Chay;Kim, Jae-Hyun;Yoo, Jae-Geun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.11
    • /
    • pp.5397-5402
    • /
    • 2012
  • Accidents involving electric equipment and economical loss by power quality deterioration related to harmonics show a rising tendency A passive filter is economic and efficient in suppressing harmonics but many engineers and designers are reluctant to install a passive filter to defect harmonics at their power system because of problems such as harmonic amplification and the probability of generating series or parallel resonance with the power system. This work introduces that passive filters will be very available to defeat harmonic problems of the power system if passive filters are well designed. We describe method and process of harmonic passive filter design. And the passive filter for the power system having harmonic problems due to use of nonlinear loads like as 100HP DC motor system, an extruding machine, an air blower and other loads are designed. Experimental results verify the performance of the passive filter designed by the described method and procedure.

A Case Study of Harmonic Resonance & Black Start in Weak Feed Power System (Weak Feed 전력계통의 블랙스타트와 고조파 공진 사례연구)

  • Park, Young-Chul;Lee, Eun-Seob;Son, Hyo-Soo;Lee, Seok-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.1
    • /
    • pp.40-50
    • /
    • 2016
  • In order to recover the power system during the wide power outage or power failure in the power plant, black start system should be properly operated without any problem. Especially power for black start in the geographically isolated areas of electric island is supplied from small emergency start-up generator, and loads are aux systems of gas turbines such as SFC(Static frequency converter). This paper introduces the international practices to overcome the voltage drop problem with harmonics of the system having the DC output such as SFC during black start in weak feed system and analyzes the relationship between house load inputs and harmonics. By varying the house load and input of power supply, this paper identified boundaries between weak feed and strong feed power. In order to verify the theory of stable condition in weak feed power system with DC output, house load is simulated using ETAP. Additionally MATLAB was used for harmonic analysis between the load inertia moment and non load inertia moment.

Static and Dynamic Instability Characteristics of Thin Plate like Beam with Internal Flaw Subjected to In-plane Harmonic Load

  • R, Rahul.;Datta, P.K.
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.14 no.1
    • /
    • pp.19-29
    • /
    • 2013
  • This paper deals with the study of buckling, vibration, and parametric instability characteristics in a damaged cross-ply and angle-ply laminated plate like beam under in-plane harmonic loading, using the finite element approach. Damage is modelled using an anisotropic damage formulation, based on the concept of reduction in stiffness. The effect of damage on free vibration and buckling characteristics of a thin plate like beam has been studied. It has been observed that damage shows a strong orthogonality and in general deteriorates the static and dynamic characteristics. For the harmonic type of loading, analysis was carried out on a thin plate like beam by solving the governing differential equation which is of Mathieu-Hill type, using the method of multiple scales (MMS). The effects of damage and its location on dynamic stability characteristics have been presented. The results indicate that, compared to the undamaged plate like beam, heavily damaged beams show steeper deviations in simple and combination resonance characteristics.

Characteristics Analysis of Induction Motor by Operation of Non-lineal Loads (비선형 부하의 운전시 유도전동기의 특성 해석)

  • Kim, Jong-Gyeum;Park, Young-Jeen;Lee, Eun-Woong
    • Proceedings of the KIEE Conference
    • /
    • 2006.10b
    • /
    • pp.147-153
    • /
    • 2006
  • Voltage unbalance will be generated by the load unbalance operation such as combination operation of single & three phase load and current unbalance will be more severe by the deteriorated voltage quality. Under the these unbalance conditions, all power electronic converters used in different types of electronic systems can increase harmonic disturbances by injecting harmonic currents directly into the feeder grid of three phase 4-wire. Harmonic current may cause torque to decrease. it may also overheat or become noisy and torque oscillation in the rotor can lead to mechanical resonance and vibration. This paper presents a scheme on the characteristics of induction motor under the combination of linear & non-linear loads at the three phase 4-wire power distribution system by the unbalance and harmonic components. It was able to confirm that the number of torque pulsation decreased and torque ripple values increased by the harmonics that reduction was difficult by five harmonics filters at additional driving time of single-phase non-linear load.

  • PDF

A Novel Oscillator Utilizing Corrugated CPW EBG Structure with Reduced Phase Noise and Improved Harmonic Characteristics (Corrugated CPW EBG 구조를 이용한 낮은 위상잡음과 향상된 고조파 특성을 갖는 새로운 형태의 발진기)

  • Hwang, Cheol-Gyu;Myung, Noh-Hoon
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2005.11a
    • /
    • pp.101-106
    • /
    • 2005
  • This paper presents a new microwave oscillator incorporating a corrugated coplanar waveguide (CCPW) electromagnetic bandgap (EBG) structure as its terminating resonance component. The use of a compact CCPW EBG structure was effective in reducing the phase noise and improving the harmonic characteristics of the microwave oscillator circuit without additional backside processing and drastic size increment. The fully planar CCPW oscillator oscillating at the frequency of 5.41 GHz showed a phase noise characteristic of -90.7 dBc/Hz at 100kHz offset and a second harmonic suppression of 42.67 dB.

  • PDF

Elemination of Low Order Harmonics from STATCOM using SHE-PWM (SHE-PWM을 적용한 STATCOM에 의한 저차고조파 제거 방법)

  • Choi, Soon-Ho;Kim, Chan-Ki;Lee, Seong-Doo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.5
    • /
    • pp.450-456
    • /
    • 2014
  • In HVDC converters that employ a line-commutated control, reactive power is absorbed by the rectifier and inverter terminals during AC/DC conversion. An AC filter usually consists of filters and large shunt capacitors to supply reactive power to the HVDC station. When STATCOM is used to supply reactive power to the HVDC system with AC filter, the low-order harmonics generated from STATCOM can result in a resonance between the shunt capacitor and AC network. Therefore, a control strategy based on selective harmonic elimination is adopted to minimize the low-order harmonics from STATCOM. The cancellation of harmonic instabilities is verified through simulations in PSCAD/EMTDC.

Analysis of the Harmonic Resonance of Primary Restorative Transmission System Using PSCAD/EMTDC (PSCAD/EMTDC를 이용한 시송전계통의 고조파 공진현상 분석)

  • Lee, H.J.;Cho, B.K.;Lee, K.S.;Park, S.M.;Bae, J.C.;Hwang, B.H.;Lee, N.H.;Song, I.J.
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.31-33
    • /
    • 2003
  • Power system restoration following a partial or complete blackout starts with energizing of primary transmission lines. Because system changed rapidly during early restoration process, transformer energization and load pickup is executed to maintain the power system stability. However unexpected problem such as harmonic overvoltage may be arisen during energizing transformer. The reason of harmonic overvoltage is known as transformer saturation and magnetizing in-rush current and so on, but it is difficult to estimate the condition of occurrence. This paper describes the analysis of the harmonic overvoltage while unloaded transformer is energized using PSCAD/EMTDC.

  • PDF