• Title/Summary/Keyword: Harmonic Measurement

Search Result 328, Processing Time 0.028 seconds

Evaluation of Ultrasonic Nonlinear Characteristics in Heat-Treated Aluminum Alloy (열처리된 알루미늄 합금의 초음파 비선형 특성 평가)

  • Kim, JongBeom;Cheon, Chung;Jhang, Kyung-Young;Kim, Chung-Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.2
    • /
    • pp.193-197
    • /
    • 2013
  • In this study, ultrasonic nonlinear characteristics in the heat-treated aluminum alloy have been evaluated. The nonlinearity of ultrasonic wave has been measured as the acoustic nonlinear parameter ${\beta}$, depending upon the amplitude ratio of the second-order harmonic and the fundamental frequency component of ultrasonic wave propagating through the materials. The parameter ${\beta}$ measurement has been carried out with the reflected signals from the back-wall of specimens at the same plane using the contact-type transducers. The heat-treatment, aging, has been achieved at $300^{\circ}C$ for various durations in the range of 1 to 50 hours. The tensile strength and elongation are obtained by the tensile test and then compared with the parameter ${\beta}$. There is a peak of the acoustic nonlinear parameter ${\beta}$ on 5 hours aging and the ${\beta}$ decreases thereafter, exhibiting closed relations with tensile strength and elongation. Also, the heat-treatment time showing peak in the parameter ${\beta}$ was identical to that showing severe change in the ${\sigma}-{\varepsilon}$ curve. These results suggest that the acoustic nonlinear parameter ${\beta}$ can be used for monitoring the strength variations with aging of aluminum alloys.

Design of 2nd-harmonic Quadrature Mixer for Ultra Wideband(UWB) Systems (2차 고조파를 이용한 UWB 시스템용 쿼드러쳐 혼합기 설계)

  • Jung, Goo-Young;Lim, Jong-Hyuk;Choi, Byung-Hyun;Yun, Tae-Yeoul
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.12 s.115
    • /
    • pp.1156-1163
    • /
    • 2006
  • This paper presents an ultra wideband(UWB) direct conversion mixer for IEEE 802.15.3a applications with simulation and measurement results. Since the direct conversion mixing causes dc-offset and even-order distortion, the proposed mixer adopts an anti-parallel diode pairs(APDPs) to solve these problems. The proposed mixer consists of an in-phase wilkinson power divider over $3.1{\sim}4.8GHz$, a wideband $45^{\circ}$ power divider over $1.5{\sim}2.4GHz$, and miniatured band pass filters(BPFs) for RF-LO isolations. The conversion loss is optimized with impedance matchings between APDPs and wideband components. The measured mixer shows the conversion loss of 13.5 dB, input third-order intercept-point($IIP_3$) of 7 dBm, and 1-dB gam compression point($P_{1dB}$) of -4 dBm. Quadrature(I/Q) outputs have the magnitude difference of about 1 dB and phase difference of ${\pm}3^{\circ}$.

A Compact 20 W Block Up-Converter for C-Band Satellite Communication (C-대역 위성 통신용 20 W급 주파수 상향 변환기의 소형화)

  • Jang, Byung-Jun;Moon, Jun-Ho;Jang, Jin-Man
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.4
    • /
    • pp.352-361
    • /
    • 2010
  • In this paper, a compact 20 W block-up-converter for C-band satellite communication is designed and implemented. The designed block up-converter consists of an intermediate frequency circuit, a mixer and local oscillator, a driver amplifier, a solid-state power amplifier, waveguide circuits, and a power supply module. To reduce the size of the block-up-converter, all circuits are assembled within an housing, so its dimension is just $21{\times}14{\times}11cm^3$. Especially, the waveguide filter and microstirp-to-waveguide transition are easily implemented using an housing. Also, to meet spurious and harmonics specification, various compact microstrip filters including an elliptic filter are integrated. Measurement results show that the developed block up-converter has good electrical performances: the output power of 43.7 dBm, the minimum gain of 65 dB, the gain flatness of ${\pm}1.84$, the IMD3 of -35 dBc, and the harmonic level of -105 dBc.

Analysis and Measurement of the Magnetic Fields Cause by Operation of Electromotive Installations (전동력설비의 운전에 의해 발생되는 자계의 측정과 해석)

  • 이복희;길경석
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.9 no.2
    • /
    • pp.58-67
    • /
    • 1995
  • The paper describes the variation of magnetic fields caused by the operation of induction motors. The measuring system consists of the self-integrating magnetic field sensor, amplifier, and active integrator. From the calibration experiments, the frequency bandwidth of the magnetic field measuring system ranges from 20[Hz] to 300[kHz] and sensitivity is 0.234(mV/$\mu\textrm{T}$]. The magnetic fields generated under steady state and starting operations of duction motor are recorded by the proposed measuring system, and the fast Fourier transformation(FFT) of the measured data is performed to analyze the harmonic components. A single pulsed magnetic field is strongly caused by direct starting the induction motor, and its peak value is greater than 5 times as compared with the steady state value. The long transient duration and high intensity originates from the large inductance and dynamic characteristic of the induction motor, During the steady state operation of induction motor, subharmonics of magnetic field components, which depend on the pole number of induction motor, are observed. The lower order power-line harmonics can be inferred from the voltage flicker and current ripple which are derived from the torque fluctuation of induction motor. In the case of the induction motor drived by inverter, the harmonics of magnetic field are much more than those caused by direct starting method and are found generally to increase with decreasing the driving frequency.

  • PDF

Fabrication and Characterization of Wavelength Conversion Device with Periodically Poled Ridge-type Waveguide in MgO:LiNbO3 (주기적으로 분극 반전된 MgO:LiNbO3를 이용한 리지형 광도파로 파장가변 소자 제작 및 특성)

  • Lee, H.M.;Yang, W.S.;Kim, W.K.;Lee, H.Y.;Jeong, W.J.;Kwon, S.W.;Koo, K.H.;Song, M.G.
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.3
    • /
    • pp.199-207
    • /
    • 2008
  • Wavelength converting devices with a ridge-type waveguide in periodically poled $MgO:LiNbO_3$ are made and characterized. The experimental results are compared with theoretical analysis on the effects of waveguide dimension and duty ratio of the periodically poled structure. To show the relationship of the conversion efficiency to those factors, a new measurement system is configured. That experimental results show that the center wavelength, normalized conversion efficiency and full width half maximum of the conversion efficiency curve are 1067.45 nm, 90.7%/$Wcm^2$ and 0.17 nm, respectively. Also, the estimated results of the duty period and full width half maximum of the conversion efficiency from theoretical calculations agreed well with experimental results with the errors of 0.016 ${\mu}m$ and 0.01 nm.

Design of RF Coil for Low Magnetic-Field Osteoblast Reformation System (저 자기장 조골세포 재형성 시스템용 RF 코일 설계)

  • Mun, Sung Hyuk;Cho, Choon Sik;Kim, Young-Jin
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.11
    • /
    • pp.821-827
    • /
    • 2018
  • In devices used for re-forming osteoblasts to treat osteoporosis, a magnetic field is applied from the outside of the bone, and the minerals contained in the bone are aligned in a certain direction and undergo precessional motion. When a $90^{\circ}$ RF pulse is applied by using an RF coil, protons of minerals are brought to an excited state, and phosphorus activity promoting the deposition of osteoblasts in the bone is increased, thereby reshaping the bone. Miniaturizing the RF coil that generates a signal corresponding to the harmonic of the precessional motional frequency by means of the $90^{\circ}$ RF pulse can drastically reduce the overall size of the bone reshaping system. In this study, we propose a methodology for the miniaturization of the RF coil that can be used for osteoblast re-formation using a bone reshaping system. The capacitance of the designed RF coil is 25 pF, the inductance is approximately 100 nH, and the resonance frequency is 96 MHz. The radius of the end ring of the designed RF coil is 18 cm, and the total length of the leg is $2{\times}11.6cm$. The performance of the coil is verified through post-design measurement.

A method for localization of multiple drones using the acoustic characteristic of the quadcopter (쿼드콥터의 음향 특성을 활용한 다수의 드론 위치 추정법)

  • In-Jee Jung;Wan-Ho Cho;Jeong-Guon Ih
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.3
    • /
    • pp.351-360
    • /
    • 2024
  • With the increasing use of drone technology, the Unmanned Aerial Vehicle (UAV) is now being utilized in various fields. However, this increased use of drones has resulted in various issues. Due to its small size, the drone is difficult to detect with radar or optical equipment, so acoustical tracking methods have been recently applied. In this paper, a method of localization of multiple drones using the acoustic characteristics of the quadcopter drone is suggested. Because the acoustic characteristics induced by each rotor are differentiated depending on the type of drone and its movement state, the sound source of the drone can be reconstructed by spatially clustering the results of the estimated positions of the blade passing frequency and its harmonic sound source. The reconstructed sound sources are utilized to finally determine the location of multiple-drone sound sources by applying the source localization algorithm. An experiment is conducted to analyze the acoustic characteristics of the test quadcopter drones, and the simulations for three different types of drones are conducted to localize the multiple drones based on the measured acoustic signals. The test result shows that the location of multiple drones can be estimated by utilizing the acoustic characteristics of the drone. Also, one can see that the clarity of the separated drone sound source and the source localization algorithm affect the accuracy of the localization for multiple-drone sound sources.

Development of Evaluation Method of Regional Contractility of Left Ventricle Using Gated Myocardial SPECT and Assessment of Reproducibility (게이트 심근 SPECT를 이용한 좌심실의 국소탄성률 평가방법 개발 및 재현성 평가)

  • Lee, Byeong-Il;Lee, Dong-Soo;Lee, Jae-Sung;Kang, Won-Jun;Chung, June-Key;Lee, Myung-Chul;Choi, Heung-Kook
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.6
    • /
    • pp.355-363
    • /
    • 2003
  • Purpose: Regional contractility can be calculated using the regional volume change of left ventricle measured by gated myocardial SPECT image and curve of central artery pressure obtained from radial artery pressure data. In this study, a program to obtain the regional contractility was developed, and reproducibility of regional contractility measurement was assessed. Materials and Methods: Seven patients(male:female=5:2, $58{\pm}11.9$ years) with coronary artery diseases underwent gated Tc-99m MIBI myocardial SPECT twice without delay between two scans. Regional volume change of left ventricle was estimated using CSA (Cardiac SPECT Analyzer) software developed in this study. Regional contractility was iteratively estimated from the time-elastance curve obtained using the time-pressure curve and regional time-volume curve. Reproducibility of regional contractility measurement assessed by comparing the contractility values measured twice from the same SPECT data and by comparing those measured from the pair of SPECT data obtained from a same patient. Results: Measured regional contractility was $3.36{\pm}3.38{mm}Hg/mL$ using 15-segment model, $3.16{\pm}2.25{mm}Hg/mL$ using 7-segment model, and $3.11{\pm}2.57{mm}Hg/mL$ using 5-segment model. The harmonic average of regional contractility value was almost identical to the global contractility. Correlation coefficient of regional contractility values measured twice from the same data was greater than 0.97 for all models, and two standard deviations of contractility difference on Bland Altman plot were 1.5%, 1.0%, and 0.9% for 15-, 7-, and 5-segment models, respectively. Correlation coefficient of regional contractility values measured from the pair of SPECT data obtained from a same patient was greater than 0.95 for all models, and two standard deviations on Bland Altman plot were 2.2%, 1.0%, and 1.2%. Conclusion: Regional contractility of left ventricle measured using developed software in this study was reproducible. Regional contractility of left ventricle will be a new useful index for myocardial function after analysis of the clinical data.