• Title/Summary/Keyword: Harmonic Measurement

Search Result 328, Processing Time 0.033 seconds

The THD measurement of HEP equipment power installed on 8200 series Electric locomotive (8200대 신형 전기기관차 HEP 장치 고조파 왜율 측정)

  • Kim, Dae-Sung;Lee, Kyung-Rac;Ahn, Hong-Goan;Park, Jong-Chun
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.488-497
    • /
    • 2010
  • 8100 series Electric locomotive was imported from SIEMENS of Germany on 2001. 8100 series model is modified from BR152 model to be complied with national environment. After 8100 series Electric locomotive carried out main line test for long time, 8200 series Electric locomotive produced in 10 locomotives with improvement and supplement on some parts. the one of supplement is to install the HEP equipment. In paper, about total harmonic distortion of HEP equipment power, it compares the result of combination with the result of actual measurement. It checks whether the measurement meets the specification of design or not. And it describes international standard about total harmonic distortion of supply system.

  • PDF

Effect of System Dependent Harmonics in the Measurement of Ultrasonic Nonlinear Parameter by Using Contact Transducers (접촉식 탐촉자를 이용한 초음파 비선형 파라미터의 측정에서 시스템에 의존하는 고조파 성분의 영향)

  • Choi, Ik-Hwang;Lee, Jae-Ik;Kwon, Goo-Do;Jhang, Kyung-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.4
    • /
    • pp.358-363
    • /
    • 2008
  • Ultrasonic nonlinearity has been considered as a promising method to evaluate the micro damage of material; however, its magnitude is so small that its measurement is not easy. Thus, in this study, we investigate the effects of such experimental system dependent factors in the measurement of ultrasonic nonlinear parameter by using contact PZT transducer. Experimental results showed that the effect of system dependent nonlinearity is reduced when the contact pressure and transducer input voltage are sufficiently large. These results will be very useful to find out the proper experiment condition to measure rather accurate nonlinear parameter.

Effect of Window Function for Measurement of Ultrasonic Nonlinear Parameter Using Fast Fourier Transform of Tone-Burst Signal (톤버스트 신호의 퓨리에 변환을 이용한 초음파 비선형 파라미터 측정에서 창함수가 미치는 영향)

  • Lee, Kyoung-Jun;Kim, Jongbeom;Song, Dong-Gi;Jhang, Kyung-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.4
    • /
    • pp.251-257
    • /
    • 2015
  • In ultrasonic nonlinear parameter measurement using the fast Fourier transform(FFT) of tone-burst signals, the side lobe and leakage on spectrum because of finite time and non-periodicity of signals makes it difficult to measure the harmonic magnitudes accurately. The window function made it possible to resolve this problem. In this study, the effect of the Hanning and Turkey window functions on the experimental measurement of nonlinear parameters was analyzed. In addition, the effect of changes in tone burst signal number with changes in the window function on the experimental measurement was analyzed. The result for both window functions were similar and showed that they enabled reliable nonlinear parameter measurement. However, in order to restore original signal amplitude, the amplitude compensation coefficient should be considered for each window function. On a separate note, the larger number of tone bursts was advantageous for stable nonlinear parameter measurement, but this effect was more advantageous in the case of the Hanning window than the Tukey window.

Improved Phase and Harmonic Detection Scheme using Fast Fourier Transform with Minimum Sampling Data under Distorted Grid Voltage (최소 샘플링의 고속푸리에 변환을 이용한 비정상 계통의 향상된 위상추종 및 고조파 검출 기법)

  • Kim, Hyun-Sou;Kim, Kyeong-Hwa
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.1
    • /
    • pp.72-80
    • /
    • 2015
  • In distributed generation systems, a grid-connected inverter should operate with synchronization to grid voltage. Considering that synchronization requires the phase angle of grid voltage, a phase locked loop (PLL) scheme is often used. The synchronous reference frame phase locked loop (SRF-PLL) is generally known to provide reasonable performance under ideal grid voltage. However, this scheme indicates performance degradation under the harmonic distorted or unbalanced grid voltage condition. To overcome this limitation, this paper proposes a phase and harmonic detection method of grid voltage using fast Fourier transform (FFT). To reduce the calculation time of FFT algorithm, minimum sampling data is taken from the voltage measurement to determine the phase angle and the magnitude of harmonic components. An experimental test setup for a grid-connected inverter system has been constructed. By comparative simulations and experiments under various abnormal grid voltage conditions, the proposed scheme has been proven to effectively track the phase angle of the grid voltage.

Analysis of Surface Tracking of Micro and Nano Size Alumina Filled Silicone Rubber for High Voltage AC Transmission

  • Loganathan, N.;Chandrasekar, S.
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.2
    • /
    • pp.345-353
    • /
    • 2013
  • This paper discusses the experimental results in an effort to understand the tracking and erosion resistance of the micro and nano size $Al_2O_3$ filled silicone rubber (SIR) material which has been studied under the AC voltages, with ammonium chloride as a contaminant, as per IEC 60587 test procedures. The characteristic changes in the tracking resistance of the micro and nano size filled specimens were analyzed through leakage current measurement and the eroded masses were used to evaluate the relative erosion and tracking resistance of the composites. The fundamental, third and fifth harmonic of the leakage current during the tracking study were analyzed using moving average current technique. It was observed that the harmonic components of leakage current show good correlation with the tracking and erosion resistance of the material. The thermogravimetry-derivative thermo gravimetric (TG-DTG) studies were performed to understand the thermal degradation of the composites. The physical and chemical studies were carried out by using scanning electron microscope (SEM), Energy Dispersive X-ray analysis (EDAX) and Fourier Transform Infra-red (FTIR) Spectroscopy. The obtained result indicated that the performance of nano filled SIR was better than the micro filled SIR material when the % wt. of filler increased.

A Study on the Harmonic Characteristics of SMPS Load in LED Display Board (LED 전광판용 SMPS의 고조파 특성에 관한 연구)

  • Park, Joon-Yeol;Ko, Man-Suk;Jang, Rae-Chang;Choi, Hong-Kyoo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.9
    • /
    • pp.36-43
    • /
    • 2013
  • The prevalence of electronic devices in our modern life is accompanied with the generation of harmonics caused by the nonlinear characteristic load. Especially, the employment of LED have brought the rapid use of SMPS. SMPS is used for supplying the constant DC electric power to the LED display board, but it has a big problem which gives birth of harmonics causing by its high-speed switching. measurement HIOKI 3196 equipment to solve these harmonics were measured. In this study, we are LED Display Board Load Measuring the impedance response with $X_L$ changes for removing harmonics in the measured. And we adopted the suitable passive filter by the impedance response characteristic obtained in the $X_L$ variation experiments. We are trying to deeply the application of passive harmonic filter characteristics that generation in the LED Display Board through EDSA LED simulation.

Analysis of Reduction Effect of Three Harmonic Currents by Zigzag Wiring of Single Phase Transformer (단상 변압기 지그재그 결선에 의한 3고조파 전류 저감 효과 분석)

  • Kim, Jong-Gyeum;Kim, Ji-Myeong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.3
    • /
    • pp.99-104
    • /
    • 2017
  • The three-phase four-wire power distribution system can be used to supply power to single-phase and three-phase loads at the same time. There are linear loads and nonlinear loads as single-phase loads connected to each phase. The nonlinear load generates a harmonic current during the power energy conversion process. In particular, the single-phase nonlinear load has a higher proportion of generation of the third harmonic current than the harmonics of the other orders. In a three-phase four-wire system, the third harmonic current flows through the neutral wire to the power supply side, affecting the power supply side and the line. Furthermore, the magnitude of the current flowing in the neutral line can be higher than the current flowing in the individual phase. If the neutral current is higher than the phase current, the breaker may be blocked. Therefore, it is necessary to reduce the amount of current flowing in the neutral line by harmonics. There is a method of zigzag connecting a single phase transformer by a method of reducing 3 harmonic current. In this study, the method of reducing the magnitude of the three harmonic currents flowing through the zigzag wire by comparing the polarity and the negative polarity characteristics of the single phase transformer was compared through measurement and simulation.

A Research into a Device for Measuring the Electric Power Quality and the Harmonic Frequency (전력 품질 및 전력 고조파 측정 장치에 관한 연구)

  • Oh, Kyutae;Yoo, Youngkil
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.10
    • /
    • pp.233-239
    • /
    • 2012
  • The harmonic frequency occurred in a power system causes errors and failures of equipments such as motors, and an unnecessary power consumption. The fundamental countermeasure for the harmonic frequency is to eliminate the cause of the harmonic frequency. This paper describes about making the device to figure out the cause in real time, verifying the operation of the device, and utilizing it to various power quality measurements. The power usually has the line frequency between 45Hz and 66Hz. In this research, the number of the harmonic frequencies which can be analysed inside the 2.8kHz bandwidth, the filter bandwidth of ADE7880, is 2800/f, and the maximum is 2800/45 = 63. The maximum order of the harmonic frequency in Korea, which has the line frequency of 60Hz, was measured as 2800/60 = 46th. Also, the accuracy of the voltage, current, and power measurement had the error within 0.1%, confirming that it is very precise.

A New Measurement Method of the Ground Resistance Using a Low-pass Filter in Energized Substations (지역필터를 이용한 수변전실 접지저항의 새로운 측정방법)

  • Lee, Bok-Hui;Eom, Ju-Hong;Lee, Seung-Chil;Kim, Seong-Won;An, Chang-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.8
    • /
    • pp.387-393
    • /
    • 2001
  • This paper describes an advanced measuring method and precise evaluation of the ground resistance for the grounding system of energized substations and power equipments. A grounding system of substations consists of all interconnected grounding connections of grounded conductors, neutral ground wires, underground conductors of distribution lines, cable shields, grounding terminals of equipments, and etc. It is very difficult to measure the accurate ground resistance of the grounding terminals of equipments, and etc. It is very difficult to measure the accurate ground resistance of the grounding system of high voltage energized substations because of harmonic components caused by switched power supplies or overloads. The conventional fall-of-potential method may be subject to big error if stray ground currents and potentials are present. In this work, to improve the precision in measurements of the ground resistance by eliminating the effects of harmonic components and stray currents and potentials, the investigations of the ground resistance measurement by using a low pass filter in a model energized grounding system were conducted. The accuracy of ground resistance mesurements was evaluated as a function of the ratio of the test signal to noise (S/N). The errors due to the proposed ground resistance measurement method were decreased with increasing S/N and were less than 5[%] as S/N is 10. The proposed ground resistance measurement method appears to be considerably more accurate than the conventional fall-of -potential method. It is allows cancellation of the parasitic resistance of energized grounding systems, to employ the measurement method that allows cancellation of the parasitic effects due to other circulating ground currents and ground potential rises in practical situations.

  • PDF

Measurement of Rotor Blade Deformation and Motions using Stereo Pattern Recognition Method (SPR 기법을 이용한 회전 블레이드의 변형 및 모션 측정)

  • Park, Jae-Won;Kim, Hong-Il;Han, Jae-Hung;Kim, Do-Hyung;Song, Keun-Woong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.39 no.5
    • /
    • pp.442-450
    • /
    • 2011
  • A measurement system using stereo pattern recognition (SPR) method was configured to measure the rotor blade deformations and motions. An SPR-based measurement system was prepared using six stereo cameras. Through a series of experiments to evaluate the system measurement uncertainty, it was verified that the SPR system had less than 0.2mm standard uncertainty. The combined standard uncertainties for the lead-lag, flapping, and pitching motions were estimated as 0.296mm, 0.209mm, and $0.238^{\circ}$, respectively. The SPR system was installed at a general small-scaled rotor test system at Korea Aerospace Research Institute. The blade motions and elastic deformation were successfully measured under the conditions with rotating speeds of 360rpm or 589rpm, and collective pitch angles of $0^{\circ}$, $4^{\circ}$, or $6^{\circ}$. The advantages of the SPR system was analyzed in comparison with the measurement system used in Higher Harmonic Control Aeroacoustic Rotor Test -II.