DOI QR코드

DOI QR Code

Improved Phase and Harmonic Detection Scheme using Fast Fourier Transform with Minimum Sampling Data under Distorted Grid Voltage

최소 샘플링의 고속푸리에 변환을 이용한 비정상 계통의 향상된 위상추종 및 고조파 검출 기법

  • Kim, Hyun-Sou (Dept. of Electrical and Information Engineering, Seoul National University of Science and Technology) ;
  • Kim, Kyeong-Hwa (Dept. of Electrical and Information Engineering, Seoul National University of Science and Technology)
  • Received : 2014.10.13
  • Accepted : 2014.12.22
  • Published : 2015.02.20

Abstract

In distributed generation systems, a grid-connected inverter should operate with synchronization to grid voltage. Considering that synchronization requires the phase angle of grid voltage, a phase locked loop (PLL) scheme is often used. The synchronous reference frame phase locked loop (SRF-PLL) is generally known to provide reasonable performance under ideal grid voltage. However, this scheme indicates performance degradation under the harmonic distorted or unbalanced grid voltage condition. To overcome this limitation, this paper proposes a phase and harmonic detection method of grid voltage using fast Fourier transform (FFT). To reduce the calculation time of FFT algorithm, minimum sampling data is taken from the voltage measurement to determine the phase angle and the magnitude of harmonic components. An experimental test setup for a grid-connected inverter system has been constructed. By comparative simulations and experiments under various abnormal grid voltage conditions, the proposed scheme has been proven to effectively track the phase angle of the grid voltage.

Keywords

References

  1. F. Peng, Y. W. Li, and L. Tolbert, "Control and protection of power electronics interfaced distributed generation systems in a customer-driven microgrid," in Conf. Rec. IEEE Power & Energy Society General Meeting, pp. 1-8, 2009.
  2. R. Teodorescu, F. Blaabjerg, "Flexible control of small wind turbines with grid failure detection operating in stand-alone and grid-connected mode," IEEE Transactions on Power Electronics, Vol. 19, No. 5, pp. 1323-1332, Sep. 2004. https://doi.org/10.1109/TPEL.2004.833452
  3. M. Cichowlas, M. Malinowski, M. P. Kazmierkowski, D. L. Sobczuk, P. Rodriguez, and J. Pou, "Active filtering fuction of three-phase PWM boost rectifier under different line voltage conditions," IEEE Transactions on Industrial Electronics, Vol. 52, No. 2, pp. 410-419, Apr. 2005. https://doi.org/10.1109/TIE.2005.843915
  4. M. Karimi-Ghartemani and M. R. Iravani, "A method for synchronization of power electronic converters in polluted and variable-frequency environments," IEEE Transactions on Power System., Vol. 19, No. 3, pp. 1263-1270, Aug. 2004.
  5. C. H. da Silva, R. R. Pereira, L. E. B. da Silva, G. Lambert-Torres, B. K. Bose, and S. U. Ahn, "A digital PLL scheme for three-phase system using modified synchronous reference frame," IEEE Transactions on Industrial Electronics, Vol. 57, No. 11, pp. 3814-3821, Nov. 2010. https://doi.org/10.1109/TIE.2010.2040554
  6. S. Lerdudomsak, M. Kadota, S. Doki, and S. Okum, "Harmonic currents estimation and compensation method for current control system of IPMSM in overmodulation range," in Conf. Rec. IEEE Power Conversion Conference-Nagoya, pp. 1320-1326, 2007.
  7. C. Lascu, L. Asiminoaei, I. Boldea, and F. Blaabjerg, "Frequency response analysis of current controllers for selective harmonic compensation in active power filters," IEEE Transactions on Industrial Electronics, Vol. 56, No. 2, pp. 337-347, Feb. 2009. https://doi.org/10.1109/TIE.2008.2006953
  8. M. Liserre, R. Teodorescu, and F. Blaabjerg, "Multiple harmonics control for three-phase grid converter systems with the use of PI-RES current controller in a rotating frame," IEEE Transactions on Power Electronics, Vol. 21, No. 3, pp. 836-841, May 2006. https://doi.org/10.1109/TPEL.2006.875566
  9. P. Rodriguez, J. Pou, J. Bergas, J. I. Candela, R. P. Burgos, and D. Boroyevich, "Decoupled double synchronous reference frame PLL for power converters control," IEEE Transactions on Power Electronics, Vol. 22, No. 5, pp. 584-592, Mar. 2007.
  10. K. J. Lee, D. Shin, H. J. Kim, J. P. Lee, T. J. Kim, and D. W. Yoo, "Phase-locked loop algorithm using FFT concept for grid synchronization under unbalanced voltage sags," in Conf. Rec. IEEE APEC2013, pp. 2231-2234, 2013.
  11. K. J. Lee, J. P. Lee, D. Shin, D. W. Yoo, and H. J. Kim, "A novel grid synchronization PLL method based on adaptive low-pass notch filter for grid-connected PCS," IEEE Transactions on Industrial Electronics, Vol. 61, No. 1, pp. 292-301, Jan. 2014. https://doi.org/10.1109/TIE.2013.2245622
  12. S. H. Lee, F. S. Kang, S. H. Lee, S. E. Cho, T. W. Lee, and S. J. Park, "High precise measurement of grid-connected inverter using DFT," Transactions of Korean Institute of Power Electronics, Vol. 17, No. 2, pp. 93-98, Apr. 2012. https://doi.org/10.6113/TKPE.2012.17.2.93
  13. C. Lascu, L. Asiminoaei, I. Boldea, and F. Blaabjerg, "High performance current controller for selective harmonic compensation in active power filter," IEEE Transactions on Power Electronics, Vol. 22, No. 5, pp. 1826-1835, Sep. 2007. https://doi.org/10.1109/TPEL.2007.904060
  14. S. Haykin and M. Moher, Introduction to Analog & Digital Communications: Second Edition, John Wiley&Sons, Inc., pp. 83-88, 2007.
  15. R. Teodorescu, M. Liserre, and P. Rodriguez, Grid Converters for Photovoltaic and Wind Power Systems, John Wiley&Sons, Inc., pp. 58-63, 2011.