• Title/Summary/Keyword: Harmonic Generator

Search Result 150, Processing Time 0.029 seconds

Amplification of Current Harmonics Due to Self-Excitation Capacitors for Wind Induction Generators (자여자 풍력 유도발전기의 캐패시터에 따른 고조파 전류의 증폭)

  • Oh, Yong;Choi, Yong-Sung;Hwang, Jong-Sun;Lee, Kyung-Sup
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.2
    • /
    • pp.192-197
    • /
    • 2008
  • The value of this paper is to use reduced size apparatuses to perform field measurement in order to identify and validate that the harmonic-current effects are due to the presence of self-excitation capacitance connected at stator's terminals of the studied SEIG. This paper has presented the measured electrical quantities of a three-phase $\Delta$-connected wind induction generator (WIG) under sudden connection and disconnection of resistive loads. An intelligent power-system recorder/monitor has been employed to measure three-phase voltages and currents of the studied system at the terminals of the studied WIG and the load. The measured electrical quantities have been analyzed. Total harmonic distortion (THD) of current using cumulative probability density function has been employed to determine the penetration of harmonic distortion at load side. The results show that the harmonic currents generated by the studied WIG can be severely amplified by the connected self-excited capacitance at the stator's terminals.

Eddy Current Loss Analysis of Slotless Double-sided Cored Type Permanent Magnet Generator by using Analytical Method (해석적 방법을 이용한 슬롯리스 양측식 코어드 타입 영구자석 발전기의 와전류 손실 해석)

  • Jang, Gang-Hyeon;Jung, Kyoung-Hun;Hong, Keyyong;Kim, Kyong-Hwan;Choi, Jang-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.10
    • /
    • pp.1639-1647
    • /
    • 2016
  • This paper deals with eddy current loss analysis of Slotless Double sided Cored type permanent magnet linear generator by using analytical method, space harmonic method. In order to calculate eddy current, this paper derives analytical solution by the Maxwell equation, magnetic vector potential, Faraday's law and a two-dimensional(2-D) cartesian coordinate system. First, we derived the armature reaction field distribution produced by armature wingding current. Second, by using derived armature reaction field solution, the analytical solution for eddy current density distribution are also obtained. Finally, the analytical solution for eddy current loss induced in permanent magnets(PMs) are derived by using equivalent, electrical resistance calculated from PMs volume and eddy current density distribution solution. The analytical result from space harmonic method are validated extensively by comparing with finite element method(FEM).

Study for the Design and Measurement of the High Voltage Pulse Generator Using Transformers (트랜스포머를 이용한 고전압 펄스 발생 장치의 설계와 측정평가에 관한 연구)

  • Kim, Young-Ju
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.1
    • /
    • pp.82-86
    • /
    • 2012
  • High-capacity high-voltage pulse generator that can be used for environmental clean-up was developed using transformers. High-voltage pulse is consists of the primary wave and the harmonic wave which are increased as a series circuit using transformers to make pulses. Each transformer has a band-pass characteristics. The output voltage of the pulse width 50[%] was decided. The output voltage of high-voltage pulse generator device was measured as 1.4[kV] (Peak-to-Peak).

Optimal Design of a Distributed Winding Type Axial Flux Permanent Magnet Synchronous Generator

  • You, Yong-Min;Lin, Hai;Kwon, Byung-Il
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.1
    • /
    • pp.69-74
    • /
    • 2012
  • This paper presents a distributed winding type axial flux permanent magnet synchronous generator (AFPMSG) with reduced the total harmonic distortion (THD), suitable for wind turbine generation systems. Although the THD of the proposed distributed winding type is more reduced than the concentrated winding type, the unbalance of the phase back EMF occurs. To improve the unbalance of the phase back EMF and the output power of the distributed winding type AFPMSG, the Kriging based on the latin hypercube sampling (LHS) is utilized. Finally, these optimization results are confirmed by experimental results. As a result, the unbalance of the phase back EMF and the output power of the distributed winding type AFPMSG were improved while maintaining the total harmonic distortion (THD) and the average phase back EMF.

Eliminating the Third Harmonic Effect for Six Phase Permanent Magnet Synchronous Generators in One Phase Open Mode

  • Liu, Jian;Yang, Gui-Jie;Li, Yong;Gao, Hong-Wei;Su, Jian-Yong
    • Journal of Power Electronics
    • /
    • v.14 no.1
    • /
    • pp.92-104
    • /
    • 2014
  • To insure stable operation and eliminate twice torque ripple, a topology for a six phase permanent magnet synchronous generator (SP-PMSG) with a neutral point connected together was analyzed in this paper. By adopting an extended transformation matrix, the mathematic model of the space vector control was established. The voltage and torque equations were deduced while considering the third harmonic flux and inductance. In addition, the suppression third harmonic method and the closed loop control strategy were proposed. A comparison analysis indicates that the cooper loss minimum method and the current magnitude minimum method can meet different application requirements. The voltage compensation amount for each of the methods was deduced which also takes into account the third harmonic effect. A simulation and experimental result comparison validates the consistency through theoretical derivation. It can be seen that all of the two control strategies can meet the requirements of post-fault.

A Design of Predistortion Linearizer Using Second Harmonic Signals (2차 고조파 신호를 이용한 전치 왜곡 선형화기 설계)

  • Kim Sung-Yong;Kim Young
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.12 s.103
    • /
    • pp.1239-1245
    • /
    • 2005
  • In this paper, a new predistortion linearizer using second harmonic components feedforwarding is proposed. The harmonic generator of the proposed predistorter that consists of a small signal amplifier extracts second harmonic signals. A vector modulator that modulate fundamental signal with second harmonic signals, generates the inverse third order intermodulation distortion signals and controls amplitude/phase of them with modulation factors. As a result, this linearizer is suppressed IMD3 signals of power amplifier effectively. The test results show that the third order IMD of power amplifier is suppressed more than 20 dB for CW two-tone signals. Also, it's improved the adjacent channel power ratio(ACPR) more than 5 dB for CDMA(IS-95) 4FA signals.

Study on Generation of Harmonic Voltage using Synchronous Machine with d- and q-axis Harmonic Field Windings - Part 2

  • Mukai, Eiichi;Fukai, Sumio;Kakinoki, Toshio;Yamaguchi, Hitoshi;Kimura, Yoshimasa
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.3 no.2
    • /
    • pp.132-138
    • /
    • 2014
  • We investigated the harmonic voltages generated by a synchronous machine adding d-axis and q-axis harmonic field windings to reduce the harmonics in a power line. First, electronic circuits such as a frequency multiplier, band-pass filter, and phase shifter were newly designed and made to carry out the experiment. Next, an experimental circuit, for which an AC voltage of frequency 6f synchronized to the power line voltage of frequency f could be obtained, was constructed to examine the generation of harmonic voltage in more detail. Finally, an experiment involving the generation of harmonic voltage was performed using an experimental synchronous generator with harmonic windings in the d-axis and q-axis. In this paper, the power spectrum and the waveforms of the harmonic voltages in the armature winding are presented. Moreover, the values calculated from theoretical expressions of harmonic voltages in armature winding are compared with the values obtained by the experiment.

3D electromagnetic design and electrical characteristics analysis of a 10-MW-class high-temperature superconducting synchronous generator for wind power

  • Kim, J.H.;Park, S.I.;Le, T.D.;Kim, H.M.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.16 no.2
    • /
    • pp.47-53
    • /
    • 2014
  • In this paper, the general electromagnetic design process of a 10-MW-class high-temperature superconducting (HTS) synchronous generator that is intended to be utilized for large scale offshore wind generator is discussed. This paper presents three-dimensional (3D) electromagnetic design proposal and electrical characteristic analysis results of a 10-MW-class HTS synchronous generator for wind power. For more detailed design by reducing the errors of a two-dimensional (2D) design owing to leakage flux in air-gap, we redesign and analyze the 2D conceptual electromagnetic design model of the HTS synchronous generator using 3D finite element analysis (FEA) software. Then electrical characteristics which include the no-load and full-load voltage of generator, harmonic contents of these two load conditions, voltage regulation and losses of generator are analyzed by commercial 3D FEA software.

Source Model for Harmonic Interaction Analysis between Renewable Energy Generators and Power Distribution System (계통 고조파와 분산형 전원의 상호작용 평가를 위한 고조파 모델에 관한 연구)

  • Cho, Sung-Min;Shin, Hee-Sang;Moon, Won-Sik;Kim, Jae-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.4
    • /
    • pp.733-738
    • /
    • 2011
  • As increase of nonlinear loads and renewable energy generators (REGs) being connected to power distribution system via inverters, the concern on harmonic problems have increased. Recently, the harmonics evaluation method considering TDD (Total Demand Distortion) is used to analyze the effect of harmonics from inverters on power distribution quality. Harmonic current sources are typically used for simulation of nonlinear load. Most inverter type for REGs is voltage source inverter (VSI). So, harmonic voltage sources are more suitable to analyze impact of renewable energy generator on harmonics problem in power distribution system. In this paper, we presented the circuit model to analyze interaction between harmonics from nonlinear load and REGs. We verified that the harmonic analysis using the proposed circuit model is more appropriate than the harmonics evaluation method considering TDD through case study using PSCAD/EMTDC.

A Study on the Harmonic Resonance during Restoration of Primary Restorative Transmission System (부하투입이 고조파 공진에 미치는 영향에 대한 고찰)

  • Lee, H.J.;Lee, K.S.;Park, S.M.;Yu, W.K
    • Proceedings of the KIEE Conference
    • /
    • 2004.11b
    • /
    • pp.249-251
    • /
    • 2004
  • Harmonic resonant overvoltage during restoration of primary restorative transmission system originates in switching operations and nonlinear characteristics of equipments. Actually it is difficult to predict the occurrence of harmonic overvoltage, since they result from nonlinear characteristics of transformers and other equipments. This paper describes the analysis of domestic primary restorative transmission system using PSCAD/EMTDC. The harmonic resonance is verified and showed the relation with equipments which have nonlinear characteristics such as generator and transformer in this paper. And the solution to prevent harmonic resonance is proposed too. As a result, the PSCAD/EMTDC simulation showed slightly conflictive results that had been presented by IEEE Power System Restoration Working Group report.

  • PDF