• Title/Summary/Keyword: Harmful air

Search Result 418, Processing Time 0.027 seconds

Design of the air purification system with On/Off fan control to reduce harmful air in nail shop

  • Minwoo Cheon
    • Journal of Platform Technology
    • /
    • v.11 no.6
    • /
    • pp.28-33
    • /
    • 2023
  • With the development of the beauty industry, the nail art industry is expanding, and through this, nail culture is becoming more popular. However, some products used in the nail art field may produce harmful substances, so great caution is required. In this paper, an air purification system was designed to reduce harmful air. The air purification system uses a harmful gas sensor to measure the level of pollution in the surrounding air and then turns the fan on/off to remove harmful gases and fine dust. Two types of filters and two fans can be driven and controlled respectively so that harmful gases are absorbed into the charcoal filter and fine dust is absorbed into the HEPA filter. In addition, filters, fans, and piping were appropriately placed to remove contaminated surrounding air as quickly as possible during nail procedures.

  • PDF

An Investigation of Citizen's Attitude on the Harmful Insects in House (주택에서의 유해생물에 대한 시민 인식도 조사)

  • 김영환;손종렬;문경환;변상훈
    • Journal of environmental and Sanitary engineering
    • /
    • v.17 no.1
    • /
    • pp.36-40
    • /
    • 2002
  • The purpose of study was to suggest an investigation of citizen's attitude on harmful insects in house. This study was consisted of four parts, such as basic investigation (housing shape, housing material, the period of house constructed, a cleaning condition), condition of kitchen, condition of living room condition of bathroom. The environmental pollution was increased by the development of industry and urbanization in modern. And also the clean of house has related with air quality such as pollutants and harmful insects etc. Because dwelling shape of urban come to be crowded, shut tightly and high buildings, the air quality of indoor was gradually polluted by several irregular cause. In one of housing pollution, the harmful insects was important any other than indoor air pollution. The problems of kitchen were the odor of food waste, discharge system of sewage and harmful insects. The important issues of living room were mold and construction materials, then important them of bathroom were easing nature and discharge system of sewage. A kind of the harmful insects in house investigated cockroach> mosquito> ant>fly. Finally, it appeared that the control of harmful insects can be applied to the improvement of indoor air pollutant which are difficult to be controlled in house.

Evaluation of Indoor Air Quality Performance of Paste According to Carbon Black Replacement Ratio (카본블랙 치환율에 따른 페이스트의 실내 공기질 성능 평가)

  • Kim, Yeon-Ho;Lee, Snag-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.135-136
    • /
    • 2020
  • Recently, there is a problem that is most important in constructing buildings and building materials. It is a harmful substance generated in buildings. These harmful substances are CO2, radon and formaldehyde, volatile organic compounds generated from building materials. These are bad for the human body, may have a negative effect and cause large illnesses such as cancer. Recently built apartments have a high density, so there is a problem that harmful substances do not escape well. As a result, people's interest in indoor air quality is growing and in order to solve this problem and various researches are being conducted on the materials used for concrete pouring to find out how much the materials used adsorb harmful substances. this study uses carbon black as a material that can adsorb these harmful substances. The purpose of this study is to measure the bending strength, compressive strength, and to determine whether the paste containing carbon black can improve indoor air quality.

  • PDF

Development of a remote monitoring system for gas detection at the subway station (지하철 역내 가스 검출 원격 모니터링 시스템 구현)

  • Park, Yong-Man;Kim, Hei-Sik;Kim, Gyu-Sik;Lee, Moon-Gyu
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.439-441
    • /
    • 2007
  • The seoul metropolitan subway has installed 8 lines and about 500 stations to transport 5 million passengers everyday. The underground air pollution level in the subway stations is very severe status, which is very harmful to the commutators and its personals. Although subway roles as such a massive and huge transportation system, the subway doesn't adapt yet any real-time air monitoring system. They have only some hand-held type detector equipments for monitoring air pollution. Therefore subway passengers are exposed to the harmful air pollution environment. The most harmful environmental parameters among the air pollution are known as the dust and sound noise dB level in the subway station. Because the dust is consisted of very small particles, we can't see them easily in dark condition on the platform, but it is very harmful. The monitoring system for air pollution is developed using embedded system attached with 6 different environmental sensors. This system monitors air pollution of dust sound noise, gas, temperature, humidity, inflammable gas, toxic gas in the subway ?station. The sensor unit of the ARM-CPU board and sensor transmits real time environmental data to the main server using Zigbee wireless communication module and TCP/IP network. The main control server receives and displays the real-time environmental data, and it send alarms to the personals when high level value.

  • PDF

A Study on the Measurement and Investigation of Air Quality in a University Library (대학도서관 실내 공기질 측정 및 조사 연구)

  • Lee, Jae-Won
    • Journal of Korean Library and Information Science Society
    • /
    • v.50 no.4
    • /
    • pp.635-658
    • /
    • 2019
  • In this study, the harmful factors measured in S university's central library were divided into ① air harmful substance ② biological harmful factors ③ carbon monoxide, carbon dioxide, and nitrogen dioxide concentration, measured and analyzed compared to the relevant criteria. The analysis showed that the harmful substances in the air - fine dust, asbestos, volatile organic compounds and formaldehyde - were all lower than the relevant standards, and that biological harmful factors such as fungi in the air, gramophageal bacteria, and endotoxin were also found to have no particular problems. The concentration of carbon monoxide, carbon dioxide, and nitrogen dioxide in the air was also maintained without any unusual factors compared to the concentration in the ordinary atmosphere. However, the library is a multi-use facility that needs regular cleaning and ventilation to manage the environment.

Harmful Environments (유해환경)

  • Doh, Hyun-Sim;Lee, Sa-Rah;Song, Seung-Min
    • Korean Journal of Child Studies
    • /
    • v.30 no.6
    • /
    • pp.125-137
    • /
    • 2009
  • This study reviews facts and trends of harmful environments in the last decade that negatively affected children's development. Younger children have been exposed to harmful media, drugs, facilities, and objects. A matter of chemical substances contaminating in-door air has become quite controversial, recently. In order to provide a better understanding of harmful environments against children, there are great needs for a survey covering all ages based on the clear definition of the term harmful environments, research identifying its causal effects on child development in the context of both parent-child and peer relationships, and a longitudinal study processing its effects in a life-span perspective. It is suggested that by providing parent education and a plenty of cultural facilities as social efforts to create sound family culture, psycho-social and physical environments of children are improved. Furthermore, legal regulations and supervision on harmful environments are needed to be strengthened.

  • PDF

Review of Internet of Things-Based Artificial Intelligence Analysis Method through Real-Time Indoor Air Quality and Health Effect Monitoring: Focusing on Indoor Air Pollution That Are Harmful to the Respiratory Organ

  • Eunmi Mun;Jaehyuk Cho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.86 no.1
    • /
    • pp.23-32
    • /
    • 2023
  • Everyone is aware that air and environmental pollutants are harmful to health. Among them, indoor air quality directly affects physical health, such as respiratory rather than outdoor air. However, studies that have examined the correlation between environmental and health information have been conducted with public data targeting large cohorts, and studies with real-time data analysis are insufficient. Therefore, this research explores the research with an indoor air quality monitoring (AQM) system based on developing environmental detection sensors and the internet of things to collect, monitor, and analyze environmental and health data from various data sources in real-time. It explores the usage of wearable devices for health monitoring systems. In addition, the availability of big data and artificial intelligence analysis and prediction has increased, investigating algorithmic studies for accurate prediction of hazardous environments and health impacts. Regarding health effects, techniques to prevent respiratory and related diseases were reviewed.

Ambient air pollution and allergic diseases in children

  • Kim, Byoung-Ju;Hong, Soo-Jong
    • Clinical and Experimental Pediatrics
    • /
    • v.55 no.6
    • /
    • pp.185-192
    • /
    • 2012
  • The prevalence of allergic diseases has increased worldwide, a phenomenon that can be largely attributed to environmental effects. Among environmental factors, air pollution due to traffic is thought to be a major threat to childhood health. Residing near busy roadways is associated with increased asthma hospitalization, decreased lung function, and increased prevalence and severity of wheezing and allergic rhinitis. Recently, prospective cohort studies using more accurate measurements of individual exposure to air pollution have been conducted and have provided definitive evidence of the impact of air pollution on allergic diseases. Particulate matter and ground-level ozone are the most frequent air pollutants that cause harmful effects, and the mechanisms underlying these effects may be related to oxidative stress. The reactive oxidative species produced in response to air pollutants can overwhelm the redox system and damage the cell wall, lipids, proteins, and DNA, leading to airway inflammation and hyper-reactivity. Pollutants may also cause harmful effects via epigenetic mechanisms, which control the expression of genes without changing the DNA sequence itself. These mechanisms are likely to be a target for the prevention of allergies. Further studies are necessary to identify children at risk and understand how these mechanisms regulate gene-environment interactions. This review provides an update of the current understanding on the impact of air pollution on allergic diseases in children and facilitates the integration of issues regarding air pollution and allergies into pediatric practices, with the goal of improving pediatric health.

The Effect on Indoor Air Quality Improvement by Ventilation Rate in Newly Built Apartment (환기량 변화에 따른 신축공동주택의 실내공기질 개선효과 검토)

  • Choi Seok-Yong;Kim Sang-Hee;Yee Jung-Jae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.8
    • /
    • pp.649-655
    • /
    • 2006
  • The recent indoor air quality problem in a newly-built apartment house is resulted from the improvement of airtightness performance and the use of the building material contained harmful chemical substances. As a result, these cause indoor air quality gradually to become worse and the harmful effect on occupant health called Sick House Syndrome. The most effective solution to improve the indoor air quality is to encourage the use of green building material. However, if the house is built with general building material, ventilation with outdoor air is alternative to dilute the pollutant concentration. The purpose of this re-search is to find optimum ventilation time in a newly-built apartment house at which the ventilatoris installed. It is found that the HCHO and toluene concentrations are remarkably decreased with the elapse of ventilation time and the concentration reduction rate is increased with increment of air change rate after one hour after operating the ventilator.