• 제목/요약/키워드: Hard Water

검색결과 617건 처리시간 0.035초

경(硬)캅셀제(劑)의 흡습(吸濕)에 관(關)한 연구(硏究) (Studies on Water Vapor Sorption through Hard Gelatin Capsules)

  • 박종훈
    • Journal of Pharmaceutical Investigation
    • /
    • 제2권1호
    • /
    • pp.40-51
    • /
    • 1972
  • Water vapor sorption of corn starch in various protective film coated capsules in 100% RH chamber for 14 days were as follows: The percent of water vapor sorption were 28.63% in uncoated capsule, 25.16% in hydroxy propylcellulose(HPC) coated capsule, 15.59% in 2-methyl-5-vinyl pyridine-methyl acrylated-methacrylic acid (MPM) coated capsule and 15.50% in polyvinyl acetal diethyl amino acetate(AEA) coated capsule. 2. Water vapor sorotion of magnesium trisilicate in various protective film coated capsules in 100% RH chamber for 14 days were as follows. The percent of water vapor sorption were 13.91% in uncoated capsule, 13.30% in HPC-coated capsule, 10.87% in MPM-caated capsule and 9.9% in AEA-coated capsule. 3. Water vapor sorption of magnesium carbonate in various protective film coated capsules in 100% RH chamber for 14 days were as follows: The percent of water vapor sorption were 12.48% in uncoated capsule, 10.72% in HPC-coated capsule, 8.10% in MPM coated capsule and 7.8% in AEA-coated capsule. 4. MPM-coated capsules and AEA-canted capsules were mere effective to protect water vapor sorption than HPC-coated capsules.

  • PDF

상수관로의 노후도 영향인자 및 가중치 산정에 관한 연구 (Estimation of Deterioration and Weighting Factors in Pipes of Water Supply Systems)

  • 김응석;김중훈;이현동
    • 상하수도학회지
    • /
    • 제16권6호
    • /
    • pp.686-699
    • /
    • 2002
  • The purpose of this study is to estimate deterioration factors and weighting factors in pipe network which each local self-governments takes rehabilitation and replacement work present time. Deterioration factors in pipe network are able to effected of specific province or location related with water supply. Most of water supply pipes are laid under the ground, it is hard to quantify deterioration degree of water system. Moreover, the timing and economic limitation and insufficient information on the spot survey gives a difficulty to look over how old water supply system is. Accordingly, this study collects and analyses five data as the laying environment, visual analysis, analysis of soil contents, analysis of pipe material, and questionary survey data in water pipe of A city. The deterioration factor estimates 14 factors with excavation and experimental analysis and 9 factors without excavation and experimental analysis. Also, the weighting factors are estimated by using the multiple linear regressions and the linear programming. The estimated deterioration factor and weighting results are compared the analysis result of visual, pipe material, and soil contents with the Probabilistic Neural Network Model. Consequently, the model results of estimated 9 factors in this study and 14 factors show the 1-2% difference. The result show that the proposed model could be used to decide the deterioration condition of pipe line with real excavation and experimental analysis.

물의 경도가 흰쥐의 신장, 간에서 중금속 축적에 미치는 영향 (Influence of Water Hardness on Accumulation of Heavy Metals in Kidneys and Livers of Rats)

  • 한돈희
    • 한국환경보건학회지
    • /
    • 제14권2호
    • /
    • pp.51-64
    • /
    • 1988
  • It has been suggested that calcium is only one of many metals that compete with toxic metals in the body. Therefore, this study was carried out to determine the influence of water hardness on accumulation of heavy metals in rats. The seventy-five rats were divided into control and case groups. Case group was subdivided into four subgroups in proportion to the concentration of water hardness respectively, such as, 0, 250, 500, 1000ppm. Control group was fed on only deionized water, but case groups were fed on hard water with ionized heavy metals (Cd 150mg + Pb 300mg + Cu 300mg/l) for 20, 40, 60 days. The concentrations of cadmium, lead and copper were measured by atomic absorption spectrophotometry (Perkin Elmer 2380) in livers and kidneys. The results of the study are summarized as following 1. The concentration of cadmium accumulation showed the tendency of decrease in proportion to water hardness in both livers and kidneys of rats having been fed for only 60 days, respectively. 2. In only livers of rats having been fed for 60 days, essential metal, copper had the tendency of decrease according as hardness in water. 3. It was impossible to compare case with control about the tendency of lead accumulation because there was no difference between the two in livers and kidneys respectively.

  • PDF

열교환기 모델내 하천수와 시수의 Fouling 특성 비교 (A Comparative Study on the Fouling Characteristics of River and Tap Water in a Heat Exchanging Model)

  • 성순경;서상호;노형운
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.49-54
    • /
    • 2003
  • Scale is formed when hard water is heated or cooled in heat transfer equipments such as heat exchangers, condensers, evaporators, cooling towers, boilers, and pipe walls. When scale deposits in a heat exchanging surface, it is traditionally called fouling. The objective of the present study was to compare the fouling characteristics of river and tap water in a heat exchanging model. FromtheSEM analyses for tap water the $calciteformofCaCO3_{3}$ was formed. For river water, however, the $aragoniteCaCO_{3}$ wasformed.In order to investigate velocity effects on the fouling characteristics in the heat exchanging model, the inlet velocity was varied with 0.5, 1.0 and 1.5 m/s, respectively. The fouling characteristics of river water were quite different from those of tap water. For the case of the 'velocity of 1.5m/s', the overall heat transfer coefficient was reduced up to 26% than that of the 'velocity of 0.5m/s'

  • PDF

개방형 지열 히트펌프 시스템의 운전 특성 (Operation Characteristics of Open Type Geothermal Heat Pump)

  • 임효재;공형진;송윤석;박성구
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.701-706
    • /
    • 2006
  • Groundwater heat pump systems are the oldest of the ground-souce systems and it has various type. Standing column well type are must be located in hard rock geology site and produce sufficient water for the conventional open loop system. These system are indirect type(the building circulating loop and ground water are intercept). Existence of the exchanger the foundation protect water quality to use of open loop. The design of open loop system are concern on the power requirements. An experimental study was analysis the extremely heating operation COP of ground water heat pump system. Operation efficiency of the 50RT systems shows that, COP $2.9{\sim}5.0$ in heating operation. And generally it shows 3.4.

  • PDF

낙동강에서 유기오염 및 SS 농도 변화에 따른 DOC 농도 변화의 특성 (Characteristics of Changes in DOC Concentration according to Concentrations of Organic Matter and Suspended Solids in the Nakdong River)

  • 이규열;김주언;이권철;이경락;이인정;임태효
    • 한국물환경학회지
    • /
    • 제29권4호
    • /
    • pp.540-550
    • /
    • 2013
  • Temporal increase of SS induces concentrations in various forms of organic matter including BOD, COD, TOC. Consequently, it causes hard to identify sources of water pollution during or after precipitation. The objective of this study is to investigate variations of DOC concentration caused by increase of flow and changes of external factors in river by comparing to SS concentration. In results, monitoring sites (e.g., Banbyeonchen) consisting of hard riverbed showed high correlation between SS and organic matters, except BOD. On the contrary, other sites (e.g., Naesungcheon) where riverbed consists of sand were found in a wide range of annual fluctuation in SS level, whereas these sites showed a narrow range in annual DOC fluctuation. In Gumhogang and Namgang, a lower correlation between SS and other factors was found most likely because of high concentration in organic matter. However, lower annual fluctuation values of DOC were observed in comparison to those of COD and TOC. Similar results were also confirmed in main river sites, Sangju and Mulgeum. In conclusion, DOC concentration is better indicator for monitoring organic matter which cannot be provided by BOD, COD, TOC in the Nakdong river basin.

고전압 임펄스 기술을 활용한 경도 제거에서 경수의 초기부피와 인가시간이 칼슘이온 농도에 미치는 영향 (Effect of Initial Volume of Hard Water and Contact Time on the Reduction of Calcium Ion Concentration using High Voltage Impulse Technique)

  • 조승연;김태희;장인성;홍웅기;이준호
    • 전기학회논문지
    • /
    • 제66권7호
    • /
    • pp.1066-1071
    • /
    • 2017
  • Recently high voltage impulse (HVI) technique has been extensively studied for desalting processes to control the $CaCO_3$ scale formation in industrial water practices such as power plant, boiler, and heat exchange operations. Investigation of the operational parameters for the HVI is important, however, those had not been reported yet. In this study, the effect of initial feed volume and contact time on reduction of calcium ion concentration by the HVI technique was investigated. Initial feed volumes of artificial hard water which contained 100 mg/L of $Ca^{2+}$, were set to 1, 2, and 3 L respectively. After 24hr of HVI contact with 12kV, $Ca^{2+}$ ion was reduced to 50, 29 and 19 % of their initial concentration, indicating that calcium removal increased as initial feed volume decreased. This implies the applied HVI pulse energy per unit mass of calcium is important parameter determining overall desalting efficiency. A series of extended operations of HVI up to 30 days verified the long term stability of the HVI system. The calcium ion declined to 40 mg/L after 2~3 days, and further reduction of calcium was not achieved, indicating that optimum operation time could be 2~3 days under these experimental conditions. Consequently, it was confirmed that the important operational parameter of HVI technique is initial feed volume and contact time as well as the applied voltage that was already proven in the previous study.

만대천 유역의 강우량에 의한 비점오염물질 유출특성에 관한 연구 (A Study on Runoff Characteristics of Non-Point Source Pollution with Rainfall in Mandae-cheon Watershed)

  • 최한규;이진태;박수진
    • 산업기술연구
    • /
    • 제25권B호
    • /
    • pp.27-35
    • /
    • 2005
  • Non-point source pollution, which is found in soil, urban area, and agricultural area, is difficult to have its amount to be estimated. Moreover, it is hard to come up with a counterplan to cope with this pollutant. Hence, the watershed of Mandae-cheon located at the upstream of Soyang Lake was chosen as our site of study. We analyzed the relationship between precipitation level of each month and pollution load in the watershed by using statistical methods: measuring BOD, T-N and T-P - which are the causes of eutrophication - in the water; and analyzing the changes in water quality caused by precipitation level of nth.

  • PDF

선박 유수분리기용 유분검출기의 개발 (Development of Oil Content Meter for Oily Water Separator in Ship)

  • 황정웅;정병건;김창화
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제25권2호
    • /
    • pp.338-344
    • /
    • 2001
  • According to the MARPOL 73/78 of Convention, all ships should have oil filtering equipment and 15 ppm bilge which satisfy Requirements of MARPOL 73/78. This study is concerned with designing and manufacturing a prototype Oil content Meter(OCM) used in machinery area of ship. The prototype OCM is composed of two parts which are oil content sensing module and data processing unit. The oil content sensing module consists of infra-red light source, photo-diode light receivers, and a glass tube for bilge water sample. The data processing unit has a micro-processor as hard core and peripheral devices. The experimental results of prototype OCM and analysis of collected data reveal linear property between transmitted light and scattered light as long as the bilge water has low level content of oil. And this linear property leads to a oil content detecting method which is programmed and loaded into the data processing unit. The performance of the prototype OCM is compared with that of the commercial OCM in the market.

  • PDF

회류수조에서의 ABS에 의한 활주선 후류 기포항적계측 (Bubble Wake Measurement by Acoustic Bubble Spectrometer Generated by Planing Hull at Circulating Water Channel)

  • 신명수;문일성;나영인;박종천
    • 한국군사과학기술학회지
    • /
    • 제14권1호
    • /
    • pp.55-61
    • /
    • 2011
  • This paper presents bubble wake measurement results generated by the planing hull. The bubble was generated by SNAME TMB model(No. 4876) with hard chine at the CWC(Circulating Water Channel). ABS(Acoustic Bubble Spectrometer) was used to measure bubble wake measurement. The manufactured model is one meter in length and uniform velocity to generate the bubble at CWC is 3m/s, relatively higher speed than conventional hull form. Measurements were performed successfully and measured results show well the general characteristics of bubble wake generated by planing hull. Furthermore, experimental equations are proposed for the practical use.