• Title/Summary/Keyword: Hard Smooth Surface

Search Result 35, Processing Time 0.029 seconds

Conservation treatment of the sword with round pommel with a tri-ring excavated at Duckcheon-ri Tomb in Gyeongju (경주 덕천리 유적 수습 유물 보존처리-삼두환두대도를 중심으로)

  • Kim, Ji-Young;Seo, Jung-Eun;Ryu, Dong-Wan
    • 보존과학연구
    • /
    • s.26
    • /
    • pp.127-139
    • /
    • 2005
  • We have conserved the sword with round pommel with a tri-ring which was excavated from No. 1 tomb of the Duckcheon-ri at the Gyeongju and requested from Jungang Research Center of the Cultural Heritage. When this artifact excavated, it was pressed flat state because of the influence of earth pressure and stuck to a gravel and soil laid scattered on the wooden coffin. If the artifacts is handled without plan, it can be damaged, therefore that sword was collected together with soil using the Polyurethane foam. After the artifact which had a weak specific and was collected using a this method can be safetly collected as below; First, we made the supporter of article ordered using a silicon and gypsum. The silicon can conserve the weak point of the artifact because it has a flexible and smooth properties and the gypsum can adhere closely to the artifact because it has a little expansion and shrinking but a hard and fluid characters. Consequently, gypsum is a good complement to the weak point of the silicon. Second, During a remove gauze and a reinforcing agent from the surface of a artifact which was reinforced using a acetone steam method. The acetone steam method can be supplement to a dangerous problem of acetonedircet method because this can be damaged in a surface of the artifact.

  • PDF

Microstructure and Wear Properties of Oxide Dispersion Strengthened Steel Powder Added Steel-Based Composite Material for Automotive Part (산화물 분산 강화 강 분말이 첨가된 자동차 부품용 철계 복합 소재의 미세조직 및 마모 특성)

  • Kim, Young-Kyun;Park, Jong-Kwan;Lee, Kee-Ahn
    • Journal of Powder Materials
    • /
    • v.25 no.1
    • /
    • pp.36-42
    • /
    • 2018
  • In order to expand the application of oxide dispersion-strengthened (ODS) steel, a composite material is manufactured by adding mechanically alloyed ODS steel powder to conventional steel and investigated in terms of microstructure and wear properties. For comparison, a commercial automobile part material is also tested. Initial microstructural observations confirm that the composite material with added ODS steel contains i) a pearlitic Fe matrix area and ii) an area with Cr-based carbides and ODS steel particles in the form of a $Fe-Fe_3C$ structure. In the commercial material, various hard Co-, Fe-Mo-, and Cr-based particles are present in a pearlitic Fe matrix. Wear testing using the VSR engine simulation wear test confirms that the seatface widths of the composite material with added ODS steel and the commercial material are increased by 24% and 47%, respectively, with wear depths of 0.05 mm and 0.1 mm, respectively. The ODS steel-added composite material shows better wear resistance. Post-wear-testing surface and cross-sectional observations show that particles in the commercial material easily fall off, while the ODS steel-added material has an even, smooth wear surface.

Solitary mastocytoma presenting at birth

  • Ha, Non Hyeon;Lee, Yoo Jung;Park, Myong Chul;Lee, Il Jae;Kim, Sue Min;Park, Dong Ha
    • Archives of Craniofacial Surgery
    • /
    • v.19 no.2
    • /
    • pp.127-130
    • /
    • 2018
  • Mastocytosis is a rare disease which occurs in both children and adults, and it can manifest as a solitary or multiple skin lesions. Both can cause cutaneous or systemic symptoms. Because of the heterogeneity of clinical presentation of mastocytosis and its rare prevalence, it can be hard to suspect the mastocytosis at the first time. Most solitary mastocytomas are about 1-5 cm in diameter and have features of brownish-yellow, minimally elevated plaques with a smooth shiny surface. This article presents a case of solitary mastocytoma which occurred in neonate and that we treated through surgical excision. In histopathological examination, it consisted of c-kit-positive mast cells. Although pediatric cutaneous mastocytosis might regress spontaneously, clinicians should keep in mind that it could be associated with systemic mastocytosis which involves hematopoietic system.

Electrospun Calcium Metaphosphate Nanofibers: I. Fabrication

  • Kim, Ye-Na;Lee, Deuk-Yong;Lee, Myung-Hyun;Lee, Se-Jong
    • Journal of the Korean Ceramic Society
    • /
    • v.44 no.5 s.300
    • /
    • pp.144-147
    • /
    • 2007
  • Calcium metaphosphate (CMP) nanofibers with a diameter of ${\sim}600nm$ were prepared using electrospun CMP/polyvinylpyrrolidone (PVP) fibers through a process of drying for 5 h in air followed by annealing for 1 h at $650^{\circ}C$ in a vacuum. The viscosity of the CMP/PVP precursor containing 0.15 g/ml of PVP was 76 cP. Thermal analysis results revealed that the fibers were crystallized at $569^{\circ}C$. The crystal phase of the as-annealed fiber was determined to be ${\delta}-CMP\;({\delta}-Ca(PO_3)_2)$. However, the morphology of the fibers changed from smooth and uniform (as-spun fibers) to linked-particle characteristics with a tubular form most likely due to the decomposition of the inner PVP matrix. It is expected that this large amount of available surface area has the potential to provide unusually high bioactivity and fast responses in clinical hard tissue applications.

Task-Oriented Effects of Various Exercise Learning (Dart Throwing) on Proprioception (과제지향적 다양한 운동학습(다트던지기)이 고유감각에 미치는 영향)

  • Yang, Byung-Il;Park, Hyeong-Ki
    • The Journal of Korean Society for Neurotherapy
    • /
    • v.22 no.3
    • /
    • pp.25-29
    • /
    • 2018
  • Purpose In this study, 45 students were divided into task - oriented group, task - oriented intermittent group, and continuous group, and the effect of each variable on learning was changed to angle of the arms' we checked. Methods This study was conducted for 45 days from March 13 to 18, 2017 for five days in the 20 generals living in Changwon city. Dart and goniometer were used for the measurement. In the exercise program, darts were placed on a smooth, hard surface of 1.5M height and the distance to the subject was set 1.5m away. In the dart throw practice, all three groups were marked with an elbow flexion $30^{\circ}$ on the wall, and the subjects were instructed to throw the dart at that point. Results Comparisons between groups showed significant differences between the continuous task-oriented training group and the intermittent task-oriented training group and the control group at the end of training (*** P <0.001). Conclusion This study showed that the intermittent task-oriented training method showed the highest effect (*** P <0.001), which proved that the intermittent method is the most effective exercise method among the three groups.

HISTOMORPHOMETRIC STUDY OF DENTAL IMPLANTS WITH RBM AND SLA SURFACE IN THE RABBIT TIBIA (토끼 경골에서 치과용 임프란트의 RBM 및 SLA 표면처리에 따른 조직계측학적 연구)

  • Song, Kook-Hyeon;Kim, Il-Kyu;Jang, Kum-Soo;Kim, Kyu-Nam;Choi, Jin-Ung
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.32 no.6
    • /
    • pp.514-523
    • /
    • 2006
  • The purpose of the present study was to evaluate the effects of several implant surface treatments to the bone formation, by placing Machined implants, 75${\mu}m$ Calcium phosphate-blasted implants and $Al_2O_3$-blasted and acid-etched implants in rabbit tibia through histomorphometric study. Two animals of each group were sacrificed at 2, 4, 8 weeks. The specimens containing the implants were dehydrated and embedded into hard methylmethacrylate plastic. Thereafter, the sections were ground to 50${\mu}m$. The specimens were stained with Villanueva bone stain for a light microscopic study. The results were as follows; 1. When the surface roughness of three different implants was measured by Surfcorder, the Ra of the Machined group, the RBM group and the SLA group was 0.16${\mu}m$, 0.44${\mu}m$, and 1.08${\mu}m$. 2. When examining the surfaces of the implants in the scanning microscope, Machined implant has the smooth surface with a few scratches, RBM implant has the rough surface with curled ridges and valleys, and SLA implant has the rough surface structures such as sharp protruding parts and micropits measuring 1-2${\mu}m$ in diameter. 3. After 2 weeks of implantation, the percentage of bone-to-implant contact of the Machined group, the RBM group and the SLA group was 26.86%, 35.40% and 45.99%. However, its differences between each group decreased during the healing periods. 4. After 2 weeks of implantation, the percentage of bone area inside the threads of the Machined group, the RBM group and the SLA group were 21.55%, 30.43% and 41.18%. However, its difference of bone area between machined group and surface treatment groups was maintained but the difference within the surface treatment groups decreased during the healing periods. In summary, the amount of bone formation in RBM and SLA group was greater than Machined group in early healing stage. These results suggest that RBM and SLA implants can reduce the healing period for osseointegration and may be suitable for early function.

A STUDY ON THE REMOVAL TORQUE OF TITANIUM IMPLANTS (Titanium Implant의 Removal Torque에 관한 연구)

  • Lee, June-Seok;Kim, Yung-Soo;Kim, Chang-Whe
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.32 no.1
    • /
    • pp.148-169
    • /
    • 1994
  • The concept of biologic attachment of load-bearing implants has developed over the past decades as an alternative to the difficulties associated with long term implantation using mechanical fixation and bone cement. The choice of implant material is also as critical an element as site preparation or insertion procedure. The properties of implants that affect host tissue responses are not limited to chemical composition alone, but also include shape, surface characteristics, site of implantation, and mechanical interaction with host tissues. Initial mechanical interlocking prevents micromotion and may be a prerequisite for direct bone apposition. A hard tightening of screws does not necessarily mean a stronger fixation and final tightening of the fixtures is dependent on the experience of the operator. Removal torque is lower than insertion torque. The purpose of this study was to investigate differences in the removal torques at the bone-implant interface of polished and sandblasted Titanium. This experiment will give insight into important factors that must be considered when interpreting in vivo screwing forces on implants during the connection of the transmucosal abutments. We evaluated the significance of different surface textures by comparison of the withdrawal forces necessary for removal of otherwise identical rough and polished implants of Titanium and also evaluated interfacial response on the light microscopic level to implant surface. And the priority of the area of insertion on osseointegration were evaluated. 9 Titanium implants - among them, 3 were for the developmental - of either a smooth or rough surface finish were inserted in the dog mandible in the right side. 3 months later Kanon Torque Gauge was used to unscrew the implants. The results were as follows : 1. No significant difference was seen in the removal torque due to variation in surface treatment, 23 Ncm for the sandblasted and 23.33 Ncm for the polished surface (p>0.05). 2. Implants in the anterior (25 Ncm) mandible showed better resistance to unscrewing in comparison to ones in the posterior (18 Ncm) region (p<0.05). 3. Developmental fixtures (22 Ncm) had similar pullout strength to the control group (p>0.05).

  • PDF

EFFECT OF VARIOUS MECHANICAL TREATMENTS ON TITANIUM PLASMA SPRAYED IMPLANT SURFACES (Titanium plasma sprayed implant에 관한 여러가지 기계적 표면처리방법이 implant표면조도에 미치는 영향)

  • Yu, Hyeon-Seok;Park, Jae-Wan;Suh, Jo-Young
    • Journal of Periodontal and Implant Science
    • /
    • v.23 no.3
    • /
    • pp.493-506
    • /
    • 1993
  • For maintenance of an ailing or failed implant it is essential to treat the implant fixture surface so as to remove bacterial endotoxin and make a surface tolerated by surrounding soft and hard tissue. Thus in this study the method that makes the smoothest surface treated with a high speed diamond bur, a low speed diamond bur, a stone, a rubber point or Jetpolisher was studied. With the profilomenter a mean value of $R_{max}$ was measured. The hight speed diamond, the rubber point and the Jetpolisher showed a mean $R_{max}\;7.77{\mu}m$. The low speed diamond bur, the rubber, point and the Jetolisher made a mean value of $R_{max}\;8.44{\mu}m$. The stone, the rubber point and the Jetolisher showed the smoothest surfaces with a mean value of $R_{max}\;6.24{\mu}m$. TPS (titanium plasma sprayed) areas showed a mean vlaue of $R_{max}\;24.42{\mu}m$, and the smooth surfaced titanium disc manufactured by the company (IMZ, Germany) shows a mean value of $R_{max}\;3.00{\mu}m$. Under the SEM examination the disc treated with a high speed diamond bur, a rubber point and a Jetpolisher showed partially remaining TPS particles, but the height of these particles were reduced remarkably compared with those of the original TPS. The disc treated with a low speed diamond bur, a rubber point and a Jetpolisher showed a rough topography with remaining TPS on the entire surface. A stone, a rubber point and a Jetpolisher removed almost TPS and the bulk titanium metal was exposed and some scratches were made by the stone. All treated discs were revealed as rougher than the smooth surface disc manufactured by the company. An untreated TPS disc shows a very irregular surface and a $40{\mu}m$ height of the plasma sprayed areas.

  • PDF

Effect of load on the wear and friction characteristics of a carbon fiber composites (탄소 섬유 복합재의 마찰 및 마모 특성에 미치는 하중 효과)

  • Koh, Sung-Wi;Yang, Byeong-Chun;Kim, Hyung-Jin;Kim, Jae-Dong
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.40 no.4
    • /
    • pp.344-350
    • /
    • 2004
  • This is the study on dry sliding wear behavior of unidirectional carbon fiber reinforced epoxy matrix composite at ambient temperature. The wear rates and friction coefficients against the stainless steel counterpart specularly processed were experimentally determined and the resulting wear mechanisms were microscopically observed. Three principal sliding directions relative to the dominant fiber orientation in the composite wear selected. When sliding took place against smooth and hard counterpart, the highest were resistance and the lowest friction coefficient were observed in the antiparallel direction. When the velocity between the composite and the counterpart went up, the wear rate increased. The fiber destruction and cracking caused fiber bending on the contact surface, which was discovered to be dominant wear mechanism.