• Title/Summary/Keyword: Handrail

Search Result 37, Processing Time 0.03 seconds

Improvement of Handrail Slippage Characteristics Using Multi-Body Dynamic Analysis Technique (다물체 동역학 해석기술을 이용한 핸드레일의 슬립특성 개선)

  • Park, Chan-Jong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.9
    • /
    • pp.1422-1428
    • /
    • 2004
  • In this paper, computer simulation model of handrail band including pulley-driving system is developed to calculate handrail slippage. This handrail simulation model is validated with test result within operating range and used to predict its slippage behavior with respect to variation of 4 different design parameters considering the applicability into the real handrail system. Based upon this parameter study, optimal condition for handrail slippage improvement is proposed without time-consuming and costly experiments of the real handrail system. And then performance improvement of handrail slippage complied with safety code is achieved after applying the optimal condition into the real handrail band system.

A Study on the Decorating Design of the Handrail in the Korean Traditional Dwelling Houses (한국전통주택 난간의 의장성에 관한 연구)

  • 김태연;윤재웅
    • Journal of the Korean housing association
    • /
    • v.10 no.4
    • /
    • pp.83-90
    • /
    • 1999
  • This study is concerned on the decorating design and method of handrail of the old residential houses. The method of studying is proceeding to select and survey the houses identified as the cultural properties that have the value of heritage in the handrail design. The conclusion as following ; Handrail play not only functional part but embellished part. The wood Handrails can be classified in two styles ; One "pyung"(평) style, another "keja"(계자) style. The former is composed of straight lines which looks simple. On the other hand, the latter contains the elavorated decoration which gives solid beauty. In conclusion, the characteristic of the handrail in Korean structure is found in the changing the sense of the lineal and curve beauty into the symmetrical line, and is fund in the variety of the high qualified details. Over its esthetic senses, the residents'hope and need for the goodness such as good omen, rich longevity and getting boys and formed as passive symbolic world, and the auspicious signed letters and the geometric and natural forms of plants, are expressed upon the decorating design of handrail. design of handrail.

  • PDF

Method for determining the design load of an aluminium handrail on an offshore platform

  • Kim, Yeon Ho;Park, Joo Shin;Lee, Dong Hun;Seo, Jung Kwan
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.13 no.1
    • /
    • pp.511-525
    • /
    • 2021
  • Aluminium outfitting is widely used in offshore platforms owing to its anti-corrosion ability and its light weight. However, various standards exist (ISO, NORSOK and EN) for the design of handrails used in offshore platforms, and different suppliers have different criteria. This causes great confusion for designers. Moreover, the design load required by the standards is not clearly defined or is uncertain. Thus, many offshore projects reference previous project details or are conservatively designed without additional clarification. In this study, all of the codes and standards were reviewed and analysed through prior studies, and data on variable factors that directly and indirectly affect the handrails applied to offshore platforms were analysed. A total of 50 handrail design load scenarios were proposed through deterministic and probabilistic approaches. To verify the proposed new handrail design load selection scenario, structural analysis was performed using SACS (offshore structural analysis software). This new proposal through deterministic and probabilistic approaches is expected to improve safety by clarifying the purpose of the handrails. Furthermore, the acceptance criteria for probabilistic scenarios for handrails suggest considering the frequency of handrail use and the design life of offshore platforms to prevent excessive design. This study is expected to prevent trial and error in handrail design while maintaining overall worker safety by applying a loading scenario suitable for the project environment to enable optimal handrail design.

The features of the cab mask's appearance & telescopic handrail arms for New Zealand EMU (뉴질랜드 전동차 전두형상 특성 및 Telescopic Handrail Arms)

  • Park, Jae-Hong;Son, Dong-Jin;Park, Chun-Jong
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1774-1778
    • /
    • 2010
  • This paper introduced the appearance characteristics of the cab mask & telescopic handrail arms for the New Zealand EMU to be applied with inter-city transportation in 2010. The appearance characteristics are improvements of driver's sightline, implementation of safety zone of gangway plate by using the telescopic handrail arms, improvements of staff & female crew & ground crew's convenience. and also, during have looking the New Zealand EMU(Electric Multiple Unit), I hope that people who having the interesting of the cab mask design would be gotten help with basic knowledge.

  • PDF

The Effects of Handrails during Treadmill Gait Training in Stroke Patients (뇌졸중 환자의 트레드밀 훈련 시 손잡이 유무 및 위치가 보행 및 균형에 미치는 영향)

  • Nam, Seok-Hyun;Kang, Kyung-Woo;Kwon, Jung-Won;Choi, Yong-Won;Kim, Chung-Sun
    • The Journal of Korean Physical Therapy
    • /
    • v.25 no.1
    • /
    • pp.23-28
    • /
    • 2013
  • Purpose: The purpose of this study was to examine the influence of a handrail (presence and position) on treadmill gait and balance in stroke patients during gait training. Methods: 39 patients with stroke (male 31, female 8) participated in this study. The training groups were classified into a no-handrail group (NHG), front handrail group (FHG), and bilateral handrail group (BHG). Each group comprised 13 subjects. The subjects were trained to walk in a straight path 30 minutes per day for 8 weeks. The Good Balance System was used to measure static balance and dynamic balance. To measure walking ability, timed up and go (TUG) was also assessed. Results: The NHG showed no significant differences in static balance, dynamic balance, and TUG. The FHG was significantly different in their medial-lateral speed of static balance, dynamic balance, and TUG. The BHG was significantly different in their static balance, dynamic balance, and TUG. Conclusion: These findings consider the effects of holding handrails concomitantly with changes in postural stability. We conclude that for training stroke patients, treadmill walking while holding handrails improves balance and gait more than treadmill walking without holding handrails. The resulting changes in muscle activity patterns may facilitate the transfer to a gait pattern. The results of this study suggest methods for training treadmill walking in stroke patients.

Analysis of Spinal Stability Affected by Working Height, Safety Handrail and Work Experience in Using Movable Scaffold (이동식 틀비계 사용 작업 시 작업대 높이, 안전난간 유무, 숙련도에 따른 척추 안정성 분석)

  • Kim, Jung-Yong;Min, Seung-Nam;Sung, Si-Hoon
    • Journal of the Ergonomics Society of Korea
    • /
    • v.29 no.3
    • /
    • pp.347-356
    • /
    • 2010
  • The purpose of this study is to analyze the spine stability by comparing muscle activation in various scaffold working conditions. The independent working conditions were designed by two levels of working height, existence and absence of safety handrail, and the two levels of expertise. The corresponding activities of the agonist and antagonist muscles of spine were simultaneously recorded by using EMG. As results, novice worker showed increased muscle activity while doing the task on the 2nd floor, absence of handrail. And expert showed the increase of co-contraction while working on the 2nd floor without handrail. Such co-contraction was found to increase the spine stability when the working condition become risky. On the other hand, the co-contraction was prolonged, the spine muscle fatique and disc pressure could be increased, which would increase the risk of musculo-skeletal disorder. The results of co-contraction in this study indicates that the motor control system responds to maintain the stability of the spine particularly when workers cognitively recognize the danger of falling or imbalance. This study also quantitatively accounted for the biomechanical cause of LBP among workers who has to prevent themselves from falling. Therefore, if can be said that safe environment preventing falling can also prevent workers from MSDs as well. Such knowledge can be applied to design ergonomic workplace environment as well as movable scaffold.

The practical analysis of the gap of ledger scaffolding - focus on Pipe scaffolding - (강관비계 띠장 간격의 실무적 해석 - 단관비계 중심으로 -)

  • Bae, Jun-Tae;Kim, Chi-Gyeong
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2012.04a
    • /
    • pp.301-311
    • /
    • 2012
  • The law(construction standard specification, construction, standard-work regulation, Industry safety standard related regulation) related to the installation of scaffolding being used commonly on the construction site is regulated that the gap of ledger is within 1.5m and first ledger is within 2m. The gap of ledger here is essential for the stability of scaffolding structure. But it is determined that it is possible for the gap of ledger is applied by explaining safety handrail as ledger, because of the fact that in current, on the construction site, safety handrail is installed with the material of scaffolding ledger as a steel tube pipe. On this study, it is aimed to guarantee the safety by analyzing the ledger of scaffolding practically and prevent the accident of manager and laborer through the actualization.

  • PDF

Methodology of Strength Analysis of Socket for AL Handrail in Offshore Platform (해양플랫폼 알루미늄 핸드레일 적용을 위한 소켓 구조강도 평가법)

  • Kim, Yeon-Ho;Park, Joo-Shin;Seo, Jung-Kwan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.2
    • /
    • pp.354-360
    • /
    • 2022
  • The aluminum handrails used for promoting structural strength and weight reduction of the topside in an offshore platform are designed according to international standards (ISO, NORSOK, and Austria Standard), and consider the most conservative load combinations. Existing aluminum handrails are bolted to a socket when installed on the topside of a platform, and the amount of deflection of the handrail is largely influenced by the socket design. However, the importance of socket design has been overlooked, and furthermore, separate evaluation procedures or guidance for socket design are ambiguous. Therefore, a series analysis was performed for estimating the structural strength of aluminum handrails to obtain the governing parameters that minimize their deflection against loads. Experimental verification was performed to validate the structural safety of the new model, and we confirmed that all were satisfied within allowable deflection according to international standards. The developed model could be used in several areas in the future as it is lighter and more productive compared to existing models from overseas makers.

Bactericidal Effect of a 275-nm UV-C LED Sterilizer for Escalator Handrails: Optimization of Optical Structure and Evaluation of Sterilization of Six Bacterial Strains

  • Kim, Jong-Oh;Jeong, Geum-Jae;Son, Eun-Ik;Jo, Du-Min;Kim, Myung-Sub;Chun, Dong-Hae;Kim, Young-Mog;Ryu, Uh-Chan
    • Current Optics and Photonics
    • /
    • v.6 no.2
    • /
    • pp.202-211
    • /
    • 2022
  • In the pasteurization of escalator handrails using ultraviolet (UV) sterilizers, a combination of light distribution and escalator speed has priority over other important factors. Furthermore, since part of the escalator handrail has a curved structure, proper design is needed to improve the sterilization rate on the surfaces touched by users. In this paper, two types of sterilizers satisfying these conditions are manufactured with 275-nm UV-C LEDs, after modeling the three-dimensional (3D) structure of an escalator handrail and simulating optical distributions of UV-C irradiation on the handrail's surface according to light-emitting diode (LED) positions and reflector variations in the sterilizers. Pasteurization experiments with the UV-C LED sterilizers are conducted on six types of gram-positive and gram-negative bacteria, with exposure times of 0.2, 5, and 15 s at an actual installation distance of 20 mm. The sterilization rates for the gram-positive bacteria are 10.63% to 27.94% at 0.2 s, 89.44% to 96.30% at 5 s, and 99.64% to 99.88% at 15 s. Those for the gram-negative bacteria are 57.70% to 77.63% at 0.2 s, 98.90% to 99.49% at 5 s, and 99.88% to 99.99% at 15 s. The power consumption of the UV-C LED sterilizer is about 8 W, which can be supplied by a self-generation module instead of an external power supply.